V-2901 UNIVERSAL DOOR ANSWERING SYSTEM



Similar documents
PagePac PAGEPAL V

V-9970 SINGLE ZONE ONE-WAY STATION LEVEL PAGE CONTROL

VALCOM HANDSFREE TALKBACK PAGING SYSTEM DESIGN/INFORMATION

V-2901A UNIVERSAL DOOR ANSWERING SYSTEM

Messager USB Digital Messaging System

V-119RTVA VOICE ANNOUNCE V-119RTHF HANDSFREE TALKBACK 19 ZONE INTERCOM/PAGE CONTROL UNITS

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

CHAPTER 1. GETTING STARTED... 1

Automatic Phone-Out Home Monitoring Systems

the promoh OPERATING MANUAL

Universal Host. Desktop Digital Hybrid. User Guide. JK Audio

Add Door Phones to Your Phone System

Advantium 2 Plus Alarm

TCB-2 Auto Answer Coupler Product Manual

Auto Dialer. Manual E-921APQ E-921GPQ

Operation and Installation Manual

PCM2000 Configuration Guide

PBXport. Rackmount PBX Digital Hybrid. User Guide. JK Audio

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

TECHNICAL. Add Paging and Multiple Line Loud Ringing to Any Phone System. PA-2A Paging Amplifier Loud Ringer

Model SRMD Setra Remote Monitoring Display

PagePac Door Phone Controller V Installation and Operation Manual

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

Unattended Answering Device Instruction Manual

11/16/92 AT&T. AT&T Door Phone Controller. Installation and Operation Manual

Security Auto Dialer. Owner s Manual. Please read before using this equipment.

Water Leak Detection System

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

TECHNICAL. Smart Touch Tone Dialer with Redialing. K Touch Tone Dialer with Redialing

VPP T1250 Emergency Telephones Installation & Operation Manual

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

Installation and Operation Guide for PD4000 Series Power Control Center

User's Guide. Integrating Sound Level Datalogger. Model Introduction

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

Automatic AES Change-Over

Industrial Ringdown/Autodialer Telephone SCR Series

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Warranty

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

TOA 900 SERIES II MIXER POWER AMPLIFIER

How To Connect A Music Source To A Cartridge

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Warranty

Installation and Operation Guide PD4600 Series Converter Replacement

User manual Rev 1.3 Contents

INSTALLATION. Omega 8000 Series Controller For Use With Omega 90 Siren/P.A. Amplifier

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

Single Station Remote Alarm

VK-250 WARRANTY REGISTRATION FORM

Zetron Desktop Microphone Manual F

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Installation and Operation Guide for PD4100 Series Power Control Centers

Installation & Operation Manual for EC-8 Phone Line Consolidator

Nest Learning Thermostat Installation Guide. Installation step-by-step

Back-UPS Pro 1300/1500 Installation and Operation

PEDAL POWER. User s Manual

How To Use A 1232 On A 1236 On A Computer Or A Cell Phone

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY METRIC SPECIFICATIONS FOR RS232 LEASED LINE MODEMS (LOW SPEED MODEL 400)

Remote Alarm Monitoring System

Wireless Home Security System Product Manual (Model #80355)

Tone Hammer 500. Owners Manual. Manual Version 1.0

Contents. Safety Warnings... 1

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

INSTRUCTION MANUAL MODEL PCD-88

Installation and Operation Back-UPS 1250, 1300, 1500

F2400 FOM II Series Fiber Optic Modem Technical Manual

INSTALLATION GUIDE. Doorbell Interface DBI-2

User guide Conference phone Konftel 100

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

Configuration Instructions

Contents. 2 NP560-NP562 Installation Guide YML821 Rev1

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Installation and Operation Guide for PD5100 Automatic Transfer Switch

6002TA Analog Port Terminal Adapter User Manual

Operation Manual. Made in the U.S.A. For questions or concerns with this unit, please call DO NOT return this antenna to your dealer.

LCD5500Z / PKP-LCD v3.x Installation Instructions

AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power

Contents i. CNX MIDI Interface Expansion Card: CNXMIDI 0

How To Use A Power Supply Unit (Upu)

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

MICROMAPPER. Users Manual. LAN Wiremap Checker

Signal Manager Installation and Operation Manual

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Voice Dialer System & Power Monitor VD-5100-SM

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

Installation Guide Smart-UPS X External Battery Pack SMX120BP

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Load Cell Amplifier Module. Instruction Manual LCA

User guide. MD PBX Light MD MD PBX Light AV MD PBX Light ES MD PBX Light BG

VALCOM ONE-WAY PAGING SYSTEM DESIGN/INFORMATION

Transcription:

VSP-V-2901 Issue 6 V-2901 UNIVERSAL DOOR ANSWERING SYSTEM INTRODUCTI The V-2901 is a Universal Door Answering System for use with any single line telephone, electronic or 1A2 key system, or PABX. These instructions contain the specifications and information necessary to install, operate, and maintain the Universal Door Answering System. SPECIFICATIS Purpose Provides remote door answering from a telephone or telephone system. Applications Electronic Key Systems PABXs 1A2 Key Systems Stand Alone Systems Refer to Figure 1 for a block diagram of a typical installation. Features Line key access from Electronic or 1A2 key systems Loop trunk port access from PABX Dedicated single line telephone access Built in handsfree amplifier RJ11 modular connector for Tip and Ring connections Power on LED Provides contact for electric strike plate Programmable door unlock codes (use with tone dial telephones) Input for manual door unlock (push-button) Removable screw terminal blocks for all connections Built in (30 Hz) ringing generator (with on/off switch) Ringback tone for speaker Works with the Valcom V-1070A or V-1071 door plate speakers AC line powered Compatible with VPB-260 Battery Back-up Capacity The V-2901 is a single talkpath unit Each V-2901 will drive up to 2 Valcom 45 Ohm Talkback Speakers Dimensions/Weight 8.6" H x 11.0" W x 2.3" D (21.6cm H x 27.9cm W x 5.8cm D) 3 lbs. (1.36 kg) Specifications Input Impedance: 600 Ohms Input Level: -10 dbm Nominal Output Impedance: 45 Ohms Ring Supply: 90VAC, 30 Hz Interrupted 1 sec. on 4 sec. off 1 947301

Door Plate Speaker Assembly E-Key C. O. Line Position V-2901 UNIVERSAL DOOR ANSWER UNIT Speaker Pushbutton FIGURE 1 - TYPICAL E-KEY INSTALLATI Power Requirements Voltage: 115VAC or 24VDC Battery Backup Power: 25 watts Environment Temperature: 0 to 50 Degrees C Humidity: 0-85% non-precipitating DESIGN General The V-2901 Remote Door Answering System when used with the V-1070A Door Plate Speaker provides voice paging with handsfree reply to a door. When the push-button on the door plate speaker is pressed, the phone system will ring. By answering the call, the system user can converse with the person at the door. If the door is equipped with an electric strike plate, the system user may allow access by dialing a code or pressing a button. Electronic Key, 1A2 Key or PABX Access When using the V-2901 with an electronic key system or PABX, the following equipment will be required: 1) 1 V-2901 Universal Door Answering Unit 2) 1 Single Line Tone Dial Telephone dedicated for door answer 3) 1 Valcom Door Plate Speaker (V-1070A or V-1071)) NOTE: A single line telephone cannot be connected to both the V-2901 and an incoming central office line. INSTALLATI Connecting Arrangement If a modular cord is used for Tip and Ring connections, start at step E. For screw terminal connections start at step TWO. 2. 3. Connect one end of a modular cord to the V-2901 RJ11 and the other end to the appropriate line position of the phone system. Go to step 4. Connect Tip of the key system line position (loop trunk) to Tip terminal of the V-2901. Connect Ring of the key system (loop trunk) to the Ring terminal of the V-2901. 1) 1 V-2901 Universal Door Answering Unit 2) 1 C.O. Line Position (Electronic Key System or 1 Loop Trunk Position (PABX) 1 400 type line card (1A2 key) 3) 1 Valcom V-1070A or V-1071 Door Plate Speaker Dedicated Single Line Phone Access When using the V-2901 with a single line telephone, the following equipment will be required: 4. 5. 6. Connect Tip and Ring of the V-1070A Door Plate Speaker to V-2901 screw terminals marked SPKR. Connect Door Button terminals of V-1070A to V-2901 screw terminals marked DPB. Turn slide switch SW1 if the telephone system is to ring when the door plate button is pressed. 2 947301

7. 8. Plug the V-2901 AC Line Cord into appropriate 115VAC receptacle. Adjust volume (See "Volume Adjustments"). Remote Door Unlock with Tone Dial Telephone 2. Refer to Table 1 for dip switch settings to program single digit door unlock code. Figure 3 shows the V-2901 contact arrangement available for electric strike plate operation. Before connecting an electric lock to the V-2901, consult the manufacturers instructions for the proper connecting arrangement. Remote Door Unlock with Push-button Connect single pole push-button to V-2901 screw terminals marked Remote Control Unlock. Remote Signaling The V-2901 contains an auxiliary set of make/break contacts. These contacts follow the ringing cycle after the door plate push-button has been pressed. They can be used to operate a remote signaling device; i.e., bell, buzzer, or light. Figure 4 shows a typical connection using these contacts. Volume Adjustments There are three volume controls on the V-2901. Two are used to adjust the page level to the door and the handsfree reply. The third control adjusts the ringback tone to the door plate speaker. See Figure 5 for location. 2. 3. Phone to Speaker: Adjust this control to give the desired listening level at the speakers. Speaker to Phone: Adjust this control so the reply from the speaker is clear. IMPORTANT: This is the most critical adjustment. Set the volume at the lowest practical level. Setting this control too high will increase background noise without giving greater talkback volume. Ringback Tone: Adjust this control to produce the desired level of ringback tone at the door plate speaker when the door plate push-button is pressed. Battery Back-Up A Valcom VPB-260 Battery Back-up may be added to the system to provide power in case of power failure. Figure 6 shows the appropriate connections. The VPB-260 should be allowed to charge for approximately 9 hours before operating the V-2901. OPERATI General When the door plate button is pressed, interrupted ring voltage from the V-2901 is applied to a C.O. line position of the telephone system and a ringback tone is sent to the door plate speaker for the duration that the call button is pressed. When the line is answered the ringing is removed and the handsfree amplifier is connected. If the door is equipped with an electric strike plate, a preset number can be dialed from the tone dial telephone, operating a relay for 2.2 seconds. The relay provides make/break contacts that may be used to operate the strike plate. A single pole push-button switch connected to the V-2901 can also be used to manually operate the door unlock relay. The V-2901 provides make/break contacts that follow the ringing cycle. These contacts can be used to operate external signaling devices. NOTE: Operation is the same when used with all telephone systems. TECHNICAL ASSISTANCE Table 2 identifies symptoms of some possible problems with solutions. Assistance in troubleshooting is available from the factory. When calling, you should have a VOM and a test set available and be calling from the job site. Call (540) 427-3900 and ask for Technical Support, or call (540) 427-6000 Valcom 24-hour Automated Support or visit our website at http://www.valcom.com. Valcom equipment is not field repairable. Valcom, Inc. maintains service facilities in Roanoke, VA. Should repairs be necessary, attach a tag to the unit clearly stating your company name, address, phone number, contact person, and the nature of the problem. Send the unit to: Valcom, Inc. Repair and Return Dept. 5614 Hollins Road Roanoke, VA 24019-5056 3 947301

TABLE 1 - DIPSWITCH SETTINGS FOR DOOR UNLOCK CODES DIGIT SW1 SW2 SW3 SW4 1 2 3 4 5 6 7 8 9 0 * # A B C D TABLE 2: TROUBLESHOOTING CHART PROBLEM 1. No system operation - Power LED not lit. 2. No system operation - Power LED is lit. 3. No paging at speaker. 4. Paging at speaker but no reply from speaker. 5. No system ringing when the doorplate button is pressed. 6. Door unlock relay does not operate. 7. No ringback tone to speaker when door button is pressed. ACTI 1a. Verify AC voltage is present at the receptacle. 1b. Check the fuse located on the bottom of the unit. If blown, replace with a 1 amp 250 VAC fuse. 2a. Verify that screw terminal connectors are completely plugged into circuit board headers. 2b. Refer to Figure 2 and verify all connections. 3a. Check door plate speaker connections. 3b. Refer to Figure 5 and adjust Phone to Speaker volume. 4a. Refer to Figure 5 and adjust Speaker to Phone volume. 5a. Refer to Figure 5 and check Ring / switch. 6a. Refer to Table 1 and verify dip switch settings. 7a. Refer to Figure 5 and adjust ringback tone volume control. 4 947301

1 2 3 4 DPB 5 FIGURE 2 ELECTRIC KEY SYSTEM, 1A2 LINE BUTT ACCESS OR PABX LOOP TRUNK ACCESS V-1070A Pushbutton V-2901 TERMINAL BLOCKS 6 7 8 9 Speaker 10 11 T 12 R SPKR 13 14 RJ11 CNECTOR T R E-KEY, 1A2 LINE POSITI OR PABX LOOP TRUNK PORT OR SINGLE LINE TELEPHE E-KEY, 1A2 LINE POSITI, PABX LOOP TRUNK PORT OR SINGLE LINE TELEPHE WITH MODULAR LINE JACK (1a) (1b) NOTE 1: Tip and Ring connections can be made by using cross connect wire (1a) or by using a modular cable (1b). MODULAR CNECTING CABLE DOOR UNLOCK RELAY CUSTOMER PROVIDED EQUIPMENT DOOR UNLOCK RELAY STATIARY ELECTRIC STRIKE PLATE STATIARY DOOR PUSHBUTT DOOR PUSHBUTT REMOTE CTROL UNLOCK AUX RELAY Pushbutton for Manual Door Release (if required) REMOTE CTROL UNLOCK AUX RELAY CUSTOMER PROVIDED EQUIPMENT STATIARY STATIARY RING SUPPLY TIP TIP RING RING RETURN RETURN FIGURE 3 - ELECTRIC LOCK CTACT ARRANGEMENT FIGURE 4 - REMOTE SIGNALLING 5 947301

VALCOM LIMITED WARRANTY Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal use and service for a period of one year from the date of shipment. The obligation under this warranty shall be limited to the replacement, repair or refund of any such defective device within the warranty period, provided that: 1. inspection by Valcom, Inc. indicates the validity of the claim, 2. the defect is not the result of damage, misuse, or negligence after the original shipment. 3. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (A service charge plus parts and labor will be applied to units defaced or physically damaged), 4. freight charges for the return of products to Valcom are prepaid, 5. all units out of warranty are subject to a service charge. The service charge will cover minor repairs (Major repairs will be subject to additional charges for parts and labor). This warranty is in lieu of and excludes all other warranties, expressed or implied, and in no event shall Valcom, Inc. be liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation, or use of the product. This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the carrier should be notified immediately. Claims for such damage should be filed with the carrier involved in accordance with the F.O.B. point. Headquarters: In Canada Valcom, Inc. CMX Corporation 1111 Industry Avenue 35 Van Kirk Drive #11 and 12 Roanoke, VA 24013 Brampton, Ontario L7A1A5 Phone: (540) 437-3900 Phone: (905) 456-1072 FAX: (540) 427-3517 FAX: (905) 456-2269 6 947301