How Ground/Water Source Heat Pumps Work



Similar documents
How To Use A Water Source Heat Pump

GEOTHERMAL HEATING AND COOLING INTRODUCTION

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

GEOTHERMAL HEAT PUMPS - TRENDS AND COMPARISONS - John W. Lund Geo-Heat Center

WaterFurnace Explains GEOTHERMAL HEATING & COOLING

Refrigeration Basics 101. By: Eric Nelson

Heating & Cooling Efficiency

Glossary of Heating, Ventilation and Air Conditioning Terms

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

AE-1483 Ground-source Heat Pumps. Carl Pedersen Energy Educator

How to choose a heat pump and use it wisely

How a Ground Source Heat Pump Works for Commercial Buildings

HEAT RECOVERY FROM CHILLED WATER SYSTEMS. Applications for Heat Reclaim Chillers

Nordic Heat Pump Product Guide

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

HVAC Systems: Overview

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

UNIT 2 REFRIGERATION CYCLE

RESEARCH HIGHLIGHT. Performance Assessment of a Cold-Climate Air Source Heat Pump

CONCEPTUALIZATION OF UTILIZING WATER SOURCE HEAT PUMPS WITH COOL STORAGE ROOFS

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

Air Conditioning 101. STN Presentation AC101

The efficient heat pump

Creating Efficient HVAC Systems

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

newsletter engineers energy-saving strategies for Water-Source Heat Pump Systems volume 36 2 providing insights for today s hvac system designer

USER S GUIDE For all Packaged Systems (Air Conditioners and Heat Pumps)

HEATING, VENTILATION & AIR CONDITIONING

Dehumidification Frequently Asked Questions

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

How does solar air conditioning work?

Energy Efficiency Technologies Air Source Heat Pump vs. Ground Source Heat Pump

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

Air-Conditioning Buying Guide

WHITE PAPER #: CLIMATEMASTER KNOWLEDGE SERIES: HEAT PUMP DESIGN FOR 100% OUTSIDE AIR SYSTEMS THE SMART SOLUTION FOR ENERGY EFFICIENCY

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

Automobile Air Conditioning Primer

The ASHRAE HQ Building Can the energy efficiency of the different mechanical systems really be compared? RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL

imagine SOLAR AIR CONDITIONING MADE EASY

RESEARCH HIGHLIGHT. The Impact of Heat Pump Water Heaters on Whole-House Energy Consumption

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

air conditioners how to choose a cooling system

Commercial Earth Energy Systems:

Renewable Heat Pumps. A guide for the technically minded

Yijun Gao, Wei Wu, Zongwei Han, Xianting Li *

Characteristics of Evaporators

CHILLER PLANT CONTROL MULTIPLE CHILLER CONTROLS

Hybrid (Dual Fuel) - Gas Heat and Air Source Heat Pump

How a Ground Source Heat Pump Works for a School or College

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

HVAC Basic Science - System Capacity

The Different Types of Air Conditioning Equipment for IT Environments

National Grid Small Business Energy Efficiency Program Overview. Central New York Energy Expo March 30, 2010

How To Design A Refrigeration System

GEOTHERMAL HEATING APPLICATIONS FOR RESIDENTIAL HOMES

Heat Recovery In Retail Refrigeration

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

Rittal White Paper 508: Economized Data Center Cooling Defining Methods & Implementation Practices By: Daniel Kennedy

Thermal Coupling Of Cooling and Heating Systems

Basic Design Considerations for Geothermal Heat Pump Systems

Forty-one miles of submerged coils that heat and cool a high school of 2,400 students.

Building Energy Systems. - HVAC: Heating, Distribution -

Energy Efficiency. Energy Efficient Home Cooling:

EVALUATION OF UNDERGROUND RAILWAY NETWORKS OPERATING SUSTAINABLE COOLING SYSTEMS. J.A. Thompson*, G.G. Maidment, J.F. Missenden and F.

Fundamentals of Hydronic Design

Evaporative Cooling for Residential and Light-Commercial

Customized Assessment Blueprint

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

The Second Law of Thermodynamics

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

The Second Law of Thermodynamics

A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

ECOCIAT. Domestic hot water heat recovery unit

LG Electronics AE Company, Commercial Air Conditioning

GROUND SOURCE HEAT PUMPS. An Overview

Lesson 36 Selection Of Air Conditioning Systems

How To Understand Evaporator

SECTION HEAT PUMPS

Drives and motors. A guide to using variable-speed drives and motors in retail environments

Research on the Air Conditioning Water Heater System

CGC s Hybrid System Loop Control

With colder weather approaching and heating costs continuing to skyrocket, ASHRAE is offering some simple ways to save energy and keep you and your

How to choose a heat pump and use it wisely

Air Conditioning Clinic

Refrigeration & HVAC

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

Proposed Design for a Coupled Ground-Source Heat Pump/Energy Recovery Ventilator System to Reduce Building Energy Demand. Matthew L.

Geothermal Heat Pump Systems

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

Greenhouse and Energy Minimum Standards (Air Conditioners and Heat Pumps) Determination

HVAC-02, Air Conditioning Troubleshooting and Repair

DOWFROST GEO 20: Propylene Glycol-Based Heat Transfer Fluid for Geothermal Heat Pump Systems

Geothermal Comfort Systems

Transcription:

How Ground/Water Source s Work Steve Kavanaugh, Professor Emeritus of Mechanical Engineering, University of Alabama Ground Source s (a.k.a. Geothermal s) are becoming more common as the costs of energy and equipment maintenance rise. When properly designed and installed they not only reduce energy use but lower maintenance costs and extend equipment life since they have no exposed outdoor equipment. They are very simple devices and have only a slight difference from traditional heat pumps. While the added cost of a ground loop, lake loop, or water well is significant, the simple water/ground source heat pump itself should cost no more than a standard heat pump and much less than the interior components of larger building HVAC systems. Figure 1 is a diagram of a closed-loop ground source heat pump (GSHP), which is also known as a ground-coupled heat pump (GCHP). A piping loop is buried in the ground, which is considerably warmer than the outdoor air in the winter. Water is circulated through the loops and into the building where the heat pump removes the heat from the water and delivers it to the air (details of how this is done are provided later). Since the water entering the heat pump is relatively warm (it is in contact with warm ground), the coefficient of performance (COP) of a GSHP is much higher than a heat pump that uses cold outside air as a heat source. GSHPs can have COPs above 4.0 when there is an efficient connection between the ground and piping loop. The process is reversed in cooling. Heat is removed from the inside air and delivered it to the water loop which rejects this heat to the ground. GSHPs also provide high cooling efficiency since the ground is much cooler than the air during the summer. Electricity Powers Cool Air Delivered Delivers Heat Removed from Air to Water Loop Water Summer Hot Air Delivered Electricity Powers Removes Heat from Water Loop and Delivers it to Air Winter Heat in Ground Extracted by Water Loop Heat in Water Loop Transferred to Ground (Closed Loop - No Water Movement to/from Ground) Heat Added in Summer is Balanced by Heat Removal in Winter Figure 1. Ground-Coupled (Closed-Loop GSHP) Figure 2 depicts a surface heat pump system (SWHP) that uses a coil submerged in a lake to replace the ground loop. SWHPs can be even more efficient in cooling than GCHPs if the lake is more than 30 feet deep. However, even deep lakes are colder in the winter than the ground, so the ground coil system performs slightly better in heating. SWHPs are typically less expensive than GCHPs if a suitable body of water is nearby. Some buildings that require water retention ponds have been able to incorporate a slightly deeper and larger reservoir.

Electricity Powers Cool Air Delivered Delivers Heat Removed from Air to Water Loop Summer Electricity Powers Heat in Water Loop Transferred to Lake Hot Air Delivered Removes Heat from Water Loop and Delivers it to Air Winter Heat in Water Loop Removed from Lake Heat Added in Summer is Balanced by Heat Removed in Winter Figure 2. Lake Source (Closed Loop Type) Figure 3 depicts a ground water heat pump (GWHP) system a third common type of GSHP. Water is pumped from a well through an isolation heat exchanger and is returned to the aquifer through an injection well. The heat pumps reject (cooling) and absorb (heating) heat from the groundwater through the heat exchanger and a closed piping loop in the building. This arrangement protects the heat pumps from the groundwater if the quality is suspect. Any required cleaning can be easily done at the stainless-steel heat exchanger. Use of injection well disposal ensures the water table level is not adversely affected. GWHPs are typically less expensive than GCHPs and SWHPs in medium-sized and large buildings. Efficiency is comparable to GCHPs and SWHPs since the added pumping requirement is usually offset by favorable ground water temperatures. Figure 3 Ground Water System (Open-Loop)

How an Air-Conditioner Works A water source air-conditioner or heat pump is a variation of a traditional air source heat pump. The explanation that follows first describes how a cooling-only water source air-conditioner works. A description of a heat pump (heating and cooling) will follow. A similar document, How Air-conditioners and s Work, is also available. The cooling-only unit consists of several primary components as shown in Figure 4: A compressor that is driven by an electric motor (typically located indoors) A condenser coil with tubing for water flow and tubing for refrigerant flow. A circulation pump that moves water through the condenser coil and outdoor water loop. An expansion device (usually located indoors) that lowers system pressure. An evaporator (or indoor) coil with tubing and many fins that cools and dehumidifies air. An indoor fan to circulate air over the cold evaporator tubing and fins A refrigerant fluid to operate at the needed pressures and temperatures Outdoor water loop (ground loop, lake loop or water well). Cool Water from Loop Warm Water to Loop Warm Liquid Expansion Device Evaporating Liquid (Cold Refrigerant) T ube-inside-t ube Water Coil (Condenser) 3 4 Room Air Cool Gas 1 (Evaporator) Hot Gas (Refrigerant) 2 Indoor Fan and Motor Cold Air Figure 4. Cooling Only Refrigeration Cycle These components function in the following manner. The compressor sucks the refrigerant from point 4 through tubing in the evaporator coil. This action causes the liquid refrigerant to evaporate and become cold ( 45ºF). The evaporating refrigerant inside the tubes cools the air being circulated over the outside of the tubes and fins by the indoor fan. In order to move the refrigerant from point 1 to point 2, it must be raised to a higher pressure by the compressor. The compressing causes the refrigerant to become hot (a similar effect occurs with an air compressor and this can be verified by quickly and carefully touching the discharge line).

The hot refrigerant is sent through the outside tubing of a tub-inside-tube water coil condenser. Water is circulated by the pump through the inside tube and cools the refrigerant and causes it to return to a liquid (condense). The water is typically 50ºF to 90ºF and is cooler than the hot refrigerant (90ºF to140ºf). The liquid refrigerant leaving the condenser (point 3) passes through an expansion device which lowers the refrigerant pressure before it returns to point 4 to repeat the cycle. How a is Different A heat pump is merely an air-conditioner with one extra valve that allows the condenser (hot coil) and evaporator (cold coil) to reverse places in the winter. Figure 5 shows close-ups of this reversing valve and where it is located in the heat pump system. In the cooling mode, the valve slides to a position that permits the hot gas from the compressor to flow through the top port to the left bottom port to the water coil. Thus, the heat pump will act like the air-conditioner described in the previous page. The valve also permits the refrigerant to travel from the indoor air coil to the compressor in cooling and from the water coil to the compressor in heating. From Discharge From Water Loop To Water Loop Tube-in-Tube Water Coil Reversing Valve Cooling Heating From Discharge From Water Coil To Suction To Indoor Bi-Flow Thermostatic Expansion Valve (TXV) Heating Mode Heating Cooling FAN Indoor To Water Coil Cooling Mode To Suction From Indoor Figure 5. Reversing Valve that Enables an Air-Conditioner to be a In the heating mode the reversing valve slides to a position that routes the hot refrigerant from the compressor through the top port to the indoor air coil (which is now the condenser) through the right bottom port of the reversing valve. Thus the air circulated by the indoor fan will be heated. After passing through the expansion device, the refrigerant enters the outdoor coil at a low temperature. Because the temperature of the refrigerant is low, heat can be transferred from the water to the refrigerant inside the evaporator. The advantage of using water from a ground or lake loop is that backup heat is often unnecessary. If the water loop is connected to a properly size ground or lake coil, the heating efficiency is exceptionally high compared to conventional systems. Figure 6 is a more anatomically correct diagram of a water-to-air heat pump. Note an additional heat recovery coil can also be added to heat domestic water with waste heat in the summer and with excess heating capacity in the winter.

Supply Duct Supply Air Auxiliary Heat (Electric Furnace) Condenser in Heating Evaporator in Cooling Indoor Fan Return Air Reversing Valve Bi-Flow TXV Filter Condensate To Hot Water From Tank Heat Recovery Coil To Ground Heat Exchanger Primary Water Coil Condenser in Cooling Evaporator in Heating (replaces outdoor coil) Figure 6. Ground Source Geothermal Unit Reference: Kavanaugh, S. P., HVAC Simplified, American Society of Heating, Refrigerating, and Air- Conditioning and Engineers (ASHRAE), Atlanta. www.ashrae.org