Reliable PCR Components for Molecular Diagnostic Assays



Similar documents
360 Master Mix. , and a supplementary 360 GC Enhancer.

Genomic DNA Clean & Concentrator Catalog Nos. D4010 & D4011

PyroPhage 3173 DNA Polymerase, Exonuclease Minus (Exo-)

ab Hi-Fi cdna Synthesis Kit

Thermo Scientific DyNAmo cdna Synthesis Kit for qrt-pcr Technical Manual

biotechrabbit Product Catalog

PrimeSTAR HS DNA Polymerase

RevertAid Premium First Strand cdna Synthesis Kit

QUANTITATIVE RT-PCR. A = B (1+e) n. A=amplified products, B=input templates, n=cycle number, and e=amplification efficiency.

Taq98 Hot Start 2X Master Mix

Mir-X mirna First-Strand Synthesis Kit User Manual

Essentials of Real Time PCR. About Sequence Detection Chemistries

DNA Integrity Number (DIN) For the Assessment of Genomic DNA Samples in Real-Time Quantitative PCR (qpcr) Experiments

AffinityScript QPCR cdna Synthesis Kit

BacReady TM Multiplex PCR System

PicoMaxx High Fidelity PCR System

Real-Time PCR Vs. Traditional PCR

Reverse Transcription System

DNA Sequence Analysis

PCR Instruments and Consumables

Application Guide... 2

Introduction To Real Time Quantitative PCR (qpcr)

TaqMan Fast Advanced Master Mix. Protocol

Identification of the VTEC serogroups mainly associated with human infections by conventional PCR amplification of O-associated genes

Herculase Hotstart DNA Polymerase

Highly specific and sensitive quantitation

Protocols. Internal transcribed spacer region (ITS) region. Niklaus J. Grünwald, Frank N. Martin, and Meg M. Larsen (2013)

CompleteⅡ 1st strand cdna Synthesis Kit

DyNAmo cdna Synthesis Kit for qrt-pcr

Whole genome Bisulfite Sequencing for Methylation Analysis Preparing Samples for the Illumina Sequencing Platform

Creating Standard Curves with Genomic DNA or Plasmid DNA Templates for Use in Quantitative PCR

RT-PCR: Two-Step Protocol

Speed Matters - Fast ways from template to result

Analysis of the DNA Methylation Patterns at the BRCA1 CpG Island

Mir-X mirna First-Strand Synthesis and SYBR qrt-pcr

GenScript BloodReady TM Multiplex PCR System

Cloning Blunt-End Pfu DNA Polymerase- Generated PCR Fragments into pgem -T Vector Systems

SNP genotyping. Gene expression. And now Solexa sequencing.

How many of you have checked out the web site on protein-dna interactions?

Real-time quantitative RT -PCR (Taqman)

Recombinant DNA & Genetic Engineering. Tools for Genetic Manipulation

RT rxns. RT rxns TRANSCRIPTME Enzyme Mix (1) 40 µl 2 x 50 µl 5 x 40 µl

restriction enzymes 350 Home R. Ward: Spring 2001

IIID 14. Biotechnology in Fish Disease Diagnostics: Application of the Polymerase Chain Reaction (PCR)

Terra PCR Direct Polymerase Mix User Manual

HiPer RT-PCR Teaching Kit

HBV Quantitative Real Time PCR Kit

ChIP TROUBLESHOOTING TIPS

All-in-One mirna qrt-pcr Reagent Kits For quantitative detection of mature mirna

Troubleshooting for PCR and multiplex PCR

Nucleic Acid Techniques in Bacterial Systematics

Quantification of Mycobacterium Tuberculosis. 150 tests

Welcome to Pacific Biosciences' Introduction to SMRTbell Template Preparation.

Assembly of Restriction Enzyme Digestions

Intended Use: The kit is designed to detect the 5 different mutations found in Asian population using seven different primers.

Lyme Disease. genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere... RecA gene. 150 tests. Primerdesign Ltd.

Hepatitis B Virus. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere... Core Protein Region. 150 tests.

Forensic DNA Testing Terminology

ZR DNA Sequencing Clean-up Kit

QPCR Applications using Stratagene s Mx Real-Time PCR Platform

SOP Title: Multiplex-PCR check of genomic DNA isolated from FFPE tissue for its usability in array CGH analysis

Genomic DNA Extraction Kit INSTRUCTION MANUAL

4. DNA replication Pages: Difficulty: 2 Ans: C Which one of the following statements about enzymes that interact with DNA is true?

MMLV High Performance Reverse Transcriptase

Troubleshooting the Single-step PCR Site-directed Mutagenesis Procedure Intended to Create a Non-functional rop Gene in the pbr322 Plasmid

Řekněte si o vzorky zdarma!

Human Herpes Virus 4 (Epstein Barr)

Reduced Representation Bisulfite Sequencing for Methylation Analysis Preparing Samples for the Illumina Sequencing Platform

Lyme Disease. RecA gene. 150 tests. Quantification of Lyme Disease genomes. Advanced kit handbook HB

POLYMERASES & AMPLIFICATION. OneTaq RT-PCR Kit. Instruction Manual. NEB #E5310S 30 reactions

How To Write An Ipa

Epstein Barr Virus (Human Herpes virus 4) nonglycosylated membrane protein (BNRF1) gene. genesig Advanced Kit. DNA testing

QIAGEN OneStep RT-PCR Handbook

The fastest spin-column based procedure for purifying up to 10 mg of ultra-pure endotoxin-free transfection-grade plasmid DNA.

Epstein Barr Virus (Human Herpes virus 4) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

Table of Contents. I. Description II. Kit Components III. Storage IV. 1st Strand cdna Synthesis Reaction... 3

Especially developed for the transfection of mammalian cells with sirna or mirna

Hepatitis B Virus Genemer Mix

Wizard DNA Clean-Up System INSTRUCTIONS FOR USE OF PRODUCT A7280.

Lyme Disease RecA gene. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere tests. Primerdesign Ltd.

Quantification of Hepatitis B Virus. Core Protein Region. 150 tests

Wide range of high-quality enzymes and proteins for molecular biology

ZR-96 DNA Sequencing Clean-up Kit Catalog Nos. D4052 & D4053

Methods and Application Guide. Introduction to Quantitative PCR

Troubleshooting Sequencing Data

User Manual. CelluLyser Lysis and cdna Synthesis Kit. Version 1.4 Oct 2012 From cells to cdna in one tube

Technical Manual No Update Date

Wizard SV Gel and PCR Clean-Up System

In vitro analysis of pri-mirna processing. by Drosha-DGCR8 complex. (Narry Kim s lab)

Genomics GENterprise

IMBB Genomic DNA purifica8on

Global MicroRNA Amplification Kit

Gene Expression Assays

UltraClean Forensic DNA Isolation Kit (Single Prep Format)

TECHNOLOGIES, PRODUCTS & SERVICES for MOLECULAR DIAGNOSTICS, MDx ABA 298

All-in-One First-Strand cdna Synthesis Kit

First Strand cdna Synthesis

Dengue Virus subtypes 1,2 3 and 4. genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere... 3 Untranslated Region (3 UTR) 150 tests

Human Herpes Virus 1 (Herpes simplex type 1) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

MystiCq microrna cdna Synthesis Mix Catalog Number MIRRT Storage Temperature 20 C

Transcription:

Reliable PCR Components for Molecular Diagnostic Assays Terri McDonnell, MBA, PMP Senior Program Manager, Molecular Diagnostics March 2014

In this webinar we will: Discuss requirements for amplification components used in PCR-based MDx assays Introduce new family of GoTaq MDx DNA Polymerases Describe Promega MDx PCR component product portfolio Discuss customization options for MDx PCR components The products discussed in this presentation are intended for general laboratory use and are suitable for use as components of molecular diagnostic assays, where applicable country laws allow. The products themselves do not provide any diagnostic result. 2

PCR in Molecular Diagnostic Applications Wide-spread Use Across Multiple Test Applications Key Molecular Test Applications and Technologies PCR is a common technology used across MDx segments Robust & Reliable MDx IVD PCR Assay Segment Microbiology/ Virology Histology Blood Screening Prenatal Inherited Diseases Tissue Typing Oncology Pharmacodiagnostics Most widely used technology PCR, bdna, TMA, sequencing FISH, PCR, microarray, sequencing PCR, TMA PCR, FISH, sequencing, cfdna Bead array, microarray, PCR, sequencing Bead array, PCR Bead array, microarray, PCR, sequencing, cfdna Bead array, PCR, sequencing Source: Kalorama Information. World Market for Molecular Diagnostics, January 2013 3

PCR in Molecular Diagnostic Assays Consistency Depends on Quality Components dntps PCR Components Buffers MgCl 2 Enzymes Consistent Performance Utilize PCR components manufactured with: Production/Process Controls Equipment/Facilities Controls Material/Purchasing Controls Robust & Reliable MDx IVD PCR Assay 4

Quality Systems All Promega products are manufactured under our Quality System. Detailed manufacture and QC documentation Production and process controls Product Certificate of Analysis Traceable product batch records Product stability programs Product change control and notification procedures Supplier evaluation and qualification program Equipment maintenance and calibration program Non-conforming product procedures Qualified and trained personnel Design controls Scope of Quality System Controls Risk 5

Key Attributes for MDx PCR components Enzymes are a Critical Component dntps PCR Components Buffers MgCl 2 Enzymes Robust & Reliable Components MDx IVD PCR Assay PCR Engine Critical component Consistent unit activity Low contaminants Flexible formats 6

Introducing GMP-manufactured Taq DNA polymerases and hot start polymerases suitable for use in molecular in vitro diagnostic amplification assays. 7

Specifications High Quality and Consistent Performance GMP-manufactured Low DNA Contamination (bacterial, fungal, mammalian DNA) Undetectable Nuclease Contamination (exonuclease, endonuclease, nicking) Functionally Tested Multiple Formats Lot-specific Certificate of Analysis Customization Options Intended for Clinical Use- No License or royalties 8

Specifications Low DNA Contamination Low DNA Contamination (bacterial, fungal, mammalian DNA) Bacterial DNA Fungal DNA Mammalian DNA 1 unit contains < 10 copies bacterial gdna QC assay targets a conserved region of the 16S rrna gene 1 unit contains < 1 genome equivalent fungal gdna QC assay targets a conserved region of the 18S rrna gene 1 unit contains < 1 genome equivalent mammalian gdna QC assay targets a conserved region of mitochondrial DNA 9

Specifications Undetectable Nuclease Contamination Undetectable Nuclease Contamination Exonuclease No observable degradation of 1mg of Lambda DNA/Hind III Markers after incubation for 8hrs @ 22 o C, followed by 8hr @ 45 o C in the presence of 15u Taq polymerase. Endonuclease Nicking No observable nicking of 0.5mg of supercoiled DNA after incubation for 8hrs @ 22 o C, followed by 8hr @ 45 o C in the presence of 15u Taq polymerase. 10

Specifications Functionally Tested by Real-Time PCR Functionally Tested GoTaq MDx DNA Polymerase 1 unit of Taq polymerase quantitatively amplifies genomic DNA target meeting slope, y-intercept, and R 2 specifications. GoTaq MDx Hot Start Polymerase Amplify a hot-start model template to produce a single 1.5kb product, eliminating extraneous amplification products. In a non hot-start PCR, this template produces an additional 410bp amplification product. 11

Flexibility Stock and Custom Versions Available GoTaq MDx DNA Polymerase Multiple Product Formats GoTaq MDx Hot Start Polymerase 5 units/ml 5 units/ml 50 units/ml Lyophilization-ready, glycerol-free, formats Customizable 12

Flexibility Customization to Match Your Specific Requirements Customization Options Concentration Formulation Bulk Custom Dispensed Packaging / Labeling Not listed? Ask Us 13

GoTaq MDx DNA Polymerases Intended Use GMP-manufactured Taq DNA polymerases and hot start polymerases suitable for use in molecular in vitro diagnostic amplification assays. 14

Key Attributes for MDx PCR components dntps are a Required Component dntps PCR Components Buffers MgCl 2 Enzymes PCR Building Blocks Consistent concentration & purity Low contaminants Flexible formats Robust & Reliable Components MDx IVD PCR Assay 15

Specifications High Purity and Functionally Tested dntps Consistent Concentration Functionally Tested Purity Customization Options Catalog products: 100mM +/- 5mM Functionally tested in PCR HPLC: 99% 31 P NMR: 97% Triphosphate Tested for contaminating DNase and RNase activity Concentration Formulation Bulk Custom Dispensed Not listed? Ask Us Packaging / Labeling 16

Key attributes for MDx PCR components Buffer Systems are Key to Performance Optimization dntps PCR Components Buffers MgCl 2 Enzymes PCR Functional Environment Consistent formulations Low contaminants Flexible formats Robust & Reliable Components MDx IVD PCR Assay 17

Specifications MgCl 2 MgCl 2 Solution Consistent Concentration Functionally Tested Undetectable Contaminants Customization Options Endonuclease Activity Exonuclease Activity RNase Activity Concentration Custom Dispensed 25mM +/- 5mM Functionally tested in PCR No observable degradation or nicking after incubation with 1mg of plasmid DNA No observable degradation after incubation with 1mg of lambda DNA. No observable degradation after incubation with RNA. Not listed? Ask Us Bulk Packaging / Labeling 18

Specifications - Buffers PCR Buffers Catalog Standard end-point PCR Flexible Formulations Undetectable Contaminants Functionally Tested Customization Options Custom Endonuclease Activity Exonuclease Activity Custom Dispensed Real-time PCR Multiplex PCR GC-Rich Direct Sample Customer specified No observable degradation or nicking after incubation with 1mg of plasmid DNA No observable degradation after incubation with 1mg of lambda DNA Functionally tested in PCR Bulk Not listed? Ask Us Packaging / Labeling 19

Summary - Reduce Risk and Improve Performance with Quality Components dntps PCR Components Buffers MgCl 2 Enzymes Consistent Performance Utilize PCR components manufactured with: Production/Process Controls Equipment/Facilities Controls Material/Purchasing Controls Robust & Reliable Components MDx IVD PCR Assay 20

Product References: Please visit www.promega.com for more information. www.promega.com/gotaqmdx http://www.promega.com/products/molecular-diagnostics www.promega.com/custom 21