HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED



Similar documents
Desiccant Air Dryers Heatless, Heated and Heated Blower

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

BID SPECIFICATION QHD SERIES HEATLESS REGENERATIVE AIR DRYER

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Kompressoren. Adsorption Dryer AD

Medical Air Systems: Scroll

SELECT SERIES DHA/CDA HEAT-LES DESICCANT COMPRESSED AIR & GAS PURIFICATION SYSTEMS. Value and Performance Through Advanced Technology

Ingersoll Rand. Heat-Of-Compression Air Dryers

REFRIGERATED COMPRESSED AIR DRYERS

Compressed Air and Gas Drying

Meeting Your Compressed Air Treatment Needs

Adsorption air dryers ADS 1 215

HeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance ( scfm models)

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

Pro Dry Heatless dessiccant compressed air dryers

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Atlas Copco Compressed air dryers. CD series Heatless adsorption dryer series HIGH QUALITY DRY AIR

DHA & DBA Series. Heat Reactivated Desiccant Dryers

Refrigerated Compressed Air Dryers

Concept WVM Brief description. Effi cient compressed-air adsorption dryer with vacuum regeneration. NEW! Now with improved ZDMC2

Nirvana. Cycling Refrigerated Dryers

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

Element D Services Plumbing

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Owners Manual. Refrigerated Air Dryer. HX75 thru HX2400

Compressed Air Filters

ultrafilter VARIOBLO Heat Regenerated Adsorption Dryer

Kompressoren. Oil Water Separators OWS

CONTINUOUS FLOW BREATHING AIR PURIFIERS

ultrafilter HEATLESS HL Adsorption Dryer

Description of Thermal Oxidizers

Nitrogen Generator System Manual

Refrigerated Air Dryers. Catalogue

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

High Pressure Dryer HLP-MSD 0055 to 0870, PN 100 to PN 400

Refrigeration Air Dryers. Catalogue

Ultra-Filter. Compressed Air Filter. DF Series

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Air Treatment Solutions

Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators

HELPFUL HINTS ON PREPARING COMPRESSED AIR

Rotary screw compressors kw 5,5 7, , bar MODULO

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

Refrigerated. Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

Cryogenic Vacuum Pumps

How To Clean Water From An Ammonia Refrigeration System

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:

Screw Compressors ESM Fixed Speed & VS Variable Speed

Refrigeration Air Dryers ADQ. Capacity: m 3 /h

Air Dryer Application Guidelines

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Dryaire Desiccant System

Refrigeration Compressed Air Dryer Buran Ultrapulse

Compressor Service & Maintenance Manual

Quiz On Information Learned From Chapter 1

High Pressure Adsorption Dryer HLP PN 25, 0040 to 0125 HLP PN 40, 0050 to 0155

Why and How we Use Capacity Control

Owners Manual 2009 PRICE LIST DRYMAXTM. Compressed Air Treatment Products. Refrigerated Air Dryers

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

300 Series PA Pump and Cooler Assemblies

Mechanical Seal Piping Plans

COMPRESSED AIR DRYER

REGULATORS 175/153 Series

Dry-out Design Considerations and Practices for Cryogenic Gas Plants

FLASH TANK ECONOMIZER PRODUCT GUIDE

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

ThermoSorb Desiccant Dryers

Installing a Probe. Typical Installation

Atlas Copco Quality Air Solutions. Compressed Air Filters

ETC -SV. Class 0 oil-free compressed air through catalysis

Example. Fluid Power. Circuits

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

High Vacuum Transformer Oil Purification Systems (HVTOPS) & Dielectric Oil Purification Systems (DOPS)

Air Eliminators and Combination Air Eliminators Strainers

Hydraulic control unit series

ECOCIAT. Domestic hot water heat recovery unit

Filtering Samples to On-Line Process Analyzers. Guidelines for Proper Filtration and Delivery of Samples to On-Line Process Analyzers

2A.1 Features of Chiller Control Components A.3 Chilled-Water Supply Temperature Control A.4 Cooling-Water Supply Control...

Open Cycle Refrigeration System

Threaded Inline Air Heaters

PC1130 Electric Air Compressor

Refrigeration Basics 101. By: Eric Nelson

USER S MANUAL HSC-24A

CONDENSATE MANAGEMENT

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

Rotary Screw Compressors UP-Series 4 & 5.5 kw

Quality air solutions. Refrigerant Dryers Adsorption Dryers Filters Oil-Water Separators Accessories

PC1131 Electric Air Compressor

ThermoStar Refrigeration Air Dryers

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Basic Hydraulics and Pneumatics

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

In-Line Air Separators

Transcription:

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

General Air Type P Hydryer Heat Regenerative Systems Introduction General Air Type P Hydryers are electric heat regenerative dryers, designed primarily for general plant and instrument air service. They economically provide clean, dry compressed air or gas, with pressure dew points of -40 F or lower. Type P dryers are dual-tower units operating on a standard 8-hour NEMA cycle (4 hours drying and 4 hours regenerating). Optional cycle times are available for custom applications. One tower drys the wet compressed air or gas; the drying function then switches automatically to the other tower while the first tower is regenerated. Principles of Operation Adsorption (Drying) The wet fluid stream (air or gas) enters the on-stream tower through the 4-way valve and passes downward through the desiccant bed, where the water vapor is adsorbed. The clean, dry air or gas then exits the dryer. Regeneration Heating Regeneration begins with the slow depressurization of the off-stream tower. A small portion of dried air or gas (expanded to near-atmospheric pressure to increase its ability to carry water vapor) is heated and passed across the adsorbent bed, countercurrent to the adsorption flow. The liberated moisture is carried out of the bed. Regeneration Cooling When regeneration heating is complete, the cooling cycle begins. The desiccant bed is cooled by purging a small volume of dried air or gas across the bed, with the heater turned off. Demand Drying Energy Management System (Optional) Dryers are sized for maximum design flow rate and maximum design moisture load (based on minimum pressure and maximum temperature). In other words, dryers are sized for worst case operating conditions. The dryers, however, are rarely operated under this set of conditions. Operating the dryers on a fixed cycle wastes energy since the actual moisture load is less than design and the need for regeneration is reduced. The Demand Drying Energy Management System is designed to enhance the overall operating efficiency of Type P dryers by consuming only as much energy as is necessary to maintain the required outlet dew point throughout the entire operating range of the dryers. An air or gas sample is continuously monitored from the on-stream (drying) desiccant bed. If the humistat s* set point has been reached by the end of the 4-hour drying cycle, tower switchover will occur. If not, the demand cycle controller will put the solid-state timer on hold. The timer stays on hold until the humistat reaches its set point. Then, the timer resumes operation, and tower switchover occurs. The timer now resumes another 4-hour drying cycle. The optional General Air Demand Drying control system will control the cycle time to get full adsorption capacity from the desiccant bed during every cycle. Equipment wear-and-tear is also minimized with Demand Drying since moving parts (4-way switching valve, actuator, regeneration valves) cycle less frequently. *An optional digital hygrometer can be used for moisture monitoring. Page 2

Features and Benefits Standard Removable Electric Heater The flanged electric heater is not in direct contact with the desiccant. This protects the desiccant from extreme temperatures which result in premature desiccant failure due to attrition. Heater Protection Heater element skin temperature is limited to 1,100 F by a thermocouple and solid-state board. This safety feature virtually eliminates heater burnout. Automatic Heating/Cooling Termination The heating/cooling termination thermocouple automatically terminates regeneration heating and cooling, prior to the fixed cycle time, during periods of low moisture loading. This feature saves energy and reduces equipment wear. Automatic Depressurization and Repressurization These occur slowly, at the start and completion of regeneration respectively, to prevent excessive desiccant abrasion and/or fluidization. Fully Automatic Operation The General Air Model 48 solid-state control board provides a reset button and status LEDs for Board Failure, Tower On Stream Status and Heater Failure. Other Standard Features: ASME Code-stamped 150 PSIG MWP carbon steel vessels. Standard -40 F pressure dew point. Stainless-steel inlet diffusers and desiccant support screens. Desiccant fill and removal ports. Initial fill of activated alumina desiccant. Non-lubricated 4-way switching valve. NEMA 4 electrical enclosure. Pressure and temperature gauge (per tower). Relief valve. Purge flow muffler. Preset purge flow orifice. Control transformer (120/1/60). Standard User Panel featuring on/off switch, malfunction alarm and power-on lights. High temperature-resistant paint. Incoloy-clad heating elements. 460/3/60 electrics. Auxiliary purge cooldown circuit on 243P - 363P. Optional Demand Drying See page 2. Cycle Failure Alarm With Light (via pressure switches) If cycle failure occurs, the Model 48 Controller will stop timing. The Hydryer will not advance in the sequence of operation until the cause of the alarm has been corrected. High Humidity Alarm and Light A lithium chloride sensor is used to measure the moisture content of the outlet gas from the Hydryer. An alarm indicates when the gas moisture content is greater than the sensor set point. Other Optional Features: Purge flow meter with throttle valve. Color-change moisture indicator (installed). Dryer status lights: tower on stream, heater on, tower regeneration. Switching failure alarm with light (via limit switch). NEMA 7 and NEMA 4-purged enclosures. Moisture analyzer and alarm. Digital readout of outlet pressure dew points down to -110 F. Semi-automatic operation. Higher working pressure available. 12-hour, 16-hour and longer NEMA cycles available. Heat guards on towers for personnel protection. Programmable controllers available. Special package for drying cylinder gases. Desiccants other than activated alumina (molecular sieve, etc.) are available for special applications. Oversize piping, if required. Other voltages available. Auxiliary purge cooldown on 83P - 203P. For custom applications, materials, or design criteria, contact General Air. Atmospheric blower purge. Closed-loop regeneration. Page 3

Flow Diagram Standard (Under 150 PSIG MWP) 1. Electric Heater 2. Desiccant Bed Support 3. Desiccant 4. 4-Way Transfer Valve 5. Outlet Check Valve 6. Purge Orifice 7. Purge Outlet Valve (Depressurization Valve) 8. Purge Muffler 9. Thermocouple - Control 10. Thermocouple - Limit 11. Thermocouple - Auto Heat/Cool Termination 12. Desiccant Removal Port 13. Desiccant Fill Port 14. Wet Air Inlet 15. Dry Air Outlet 16. (Optional) Demand Drying Humistat and Filter 17. (Optional) Demand Drying Sample Port and Valving 18. Auxiliary Cooling Purge Line (243P thru 363P standard) NOTE: Relief Valve and some options not shown. Prefilters and Afterfilters for Maximum Protection Every regenerative compressed air dryer must be equipped with a coalescing prefilter to protect the desiccant beds from oil and/or free water contamination from the compressed air supply. This ensures top efficiency and the longest possible desiccant life. A particulate afterfilter is a must for collecting desiccant dust inherent to regenerative type dryers. The General Air coalescing prefilters and particulate afterfilters listed on page 5 are available as installed assemblies, complete with all piping and valves, or as singular components for customer installation on any regenerative dryer not so equipped. A recommended flow diagram is also shown on page 5. Page 4

TYPICAL AIR FLOW THRU DRYER AND FILTERS The filters depicted are in-line as installed on Models 203P and smaller. PREFILTER and AFTERFILTER ASSEMBLIES Installed complete with all piping and bypass valves: Coalescing Automatic Particulate Dryer Model Prefilter Float Drain Afterfilter 83P C15 71034-39 P15 103P C30 71034-39 P30 123P C50 71034-39 P30 143P CX100 71034-39 P50 163P CX160 71034-39 PX100 183P + 203P CX200 71034-38 PX160 243P CX300 71034-38 PX200 253P CX400 71034-38 PX200 303P CX600 71034-38 PX400 363P CX800 71034-38 PX400 Type P Hydryer General Specifications Model 83P 103P 123P 143P 163P 183P 203P 243P 253P 303P 363P A Height (In.) 78 87 89 104 115 116 114 119 129 128 134 B Width (In.) 51 56 62 64 68 72 77 88 88 98 107 C Depth (In.) 19 21 24 25 23 25 26 29 29 39 44 D Overhead Clearance 57 55 55 75 77 77 87 75 95 95 95 Recommended (In.) E Inlet & Outlet 1 1-1/2 1-1/2 1-1/2 2 2 2 3 3 3 4 Pipe Size (In.) NPT NPT NPT NPT FLG FLG FLG FLG FLG FLG FLG Total Est. Shipping Weight (Lbs.) 810 1,160 1,440 1,745 2,320 2,640 2,960 3,520 4,360 6,400 8,800 *Capacity SCFM @ 100 PSIG 100 200 300 425 600 800 1,000 1,200 1,550 2,200 3,200 and 100 F Heater KW 1.3 2.5 3.7 5.4 8.0 9.8 12.0 14.3 19.2 28.8 39.3 MWP 150 PSIG. For non-standard conditions, contact General Air. * Capacity is SCFM based on 14.7 PSIA @ 68 F at compressor suction when the dryer inlet is at 100 F maximum and 100 PSIG minimum. Verify system operating conditions prior to selecting a dryer. Page 5

Atmospheric Blower Purge Option Dryer Operation: Adsorption (Drying) Compressed air enters the dryer and flows downward through the desiccant bed where the water vapor is adsorbed onto the desiccant. The dry air exits the dryer. Figure 1 Heating Regeneration Heating (Figure 1) While one tower is on stream, drying, the other tower is off stream, regenerating. Regeneration is accomplished using ambient air for the heating portion, which reduces purge loss and saves energy. The off-stream tower is slowly depressurized. Ambient Blower Purge air is then passed downward through the internal heater can, where it is heated to 550 F. The hot air then flows upward through the desiccant bed, countercurrent to the adsorption flow. The desorbed water vapor exits through the purge valve and muffler to the atmosphere. Regeneration Cooling (Figure 2) Once regeneration heating is complete, the blower stops, and approximately 5% of the dry outlet air is diverted through an orifice to the regenerating tower for reactivation cooling. The very dry cooling air is expanded to atmospheric pressure and passes across the desiccant where it desorbs the remaining moisture while cooling the desiccant. The purge air used for this portion of regeneration averages 1-2% of the total inlet capacity. Figure 2 Cooling Page 6

Feature/Benefit Analysis of Blower Option: Less Purge Required Less purge means lower energy costs. The blower option will pay for itself in less than one year under normal operating conditions. Oil-Free, Pulsation-Free Blower Air (via a Vortex Blower) Minimizes desiccant abrasion or contamination. Low Noise Less than 85 dba operation. Blower Intake Filter Protects blower and desiccant from contaminants. Dry Purge Cooling Step Assures that the desiccant is cool for proper adsorption. Eliminates any possibility of preloading the desiccant with moisture. Type PC Hydryer General Specifications Model 83PC 103PC 123PC 143PC 163PC 183PC 203PC 243PC 253PC 303PC 363PC A Height (In.) 84 87 89 104 115 116 114 119 128 128 134 B Width (In.) 51 56 62 64 68 72 77 88 88 98 107 C Depth (In.) 22 24 24 27 28 29 29 36 38 52 59 D Overhead Clearance 57 62 62 78 85 85 85 76 95 95 95 Recommended (In.) E Inlet & Outlet 1 1-1/2 1-1/2 1-1/2 2 2 2 3 3 3 4 Pipe Size (In.) NPT NPT NPT NPT FLG FLG FLG FLG FLG FLG FLG Total Est. Shipping Weight (Lbs.) 850 1,200 1,500 1,850 2,450 2,800 3,150 3,800 4,600 6,800 9,300 *Capacity - Inlet SCFM @ 100 PSIG 100 200 300 425 600 800 1,000 1,200 1,550 2,200 3,200 and 100 F Heater KW 1.3 2.5 3.7 5.4 8.0 9.8 12.0 14.3 19.2 28.8 39.3 Blower KW 0.25 0.38 0.60 0.90 1.0 2.0 2.2 3.0 4.0 7.8 10.0 MWP 150 PSIG. For non-standard conditions, contact General Air. * Capacity is SCFM based on 14.7 PSIA @ 68 F at compressor suction when the dryer inlet is at 100 F maximum and 100 PSIG minimum. Verify system operating conditions prior to selecting a dryer. Page 7

Manufacturers of quality products since 1945 PSB INDUSTRIES INC. General Air Division 1202 West 12th Street Erie, PA 16501 USA Phone: 814-453-3651 Toll Free: 800-829-1119 Fax: 814-454-3492 E-mail: psb@genair.net www.psbindustries.com Printed in U.S.A. Form No. GHP, PDF-7/02 Your Contact Is: