The Basics of Natural Gas



Similar documents
Natural Gas Emergencies

Natural Gas Safety. What You Need to Know

Nonrenewable Natural Gas. Natural Gas Basics. How Was Natural Gas Formed?

Propane Gas Underground Systems: Residential Infrastructure Requirements and Energy Benefits

Proposed Amendment: Revisions to Chapter 8 Sections Proponent: RESNET Technical Committee

Utilities (Natural Gas & Electricity)

How To Stop A Gas Leak

Kennebec Valley Expansion. 442 Civic Center Dr., Suite 100 * Augusta, Maine

Fuel and Energy Conversion and Equivalence Chart

Propane and Natural Gas Safety

Air Conditioning Systems DOE, DOE ARRA, LIHEAP WX, RMP. Heating Systems DOE, DOE ARRA, LIHEAP WX, LIHEAP Crisis, Questar

Service Bulletin SA-008. DATE: June 18, 2008 TO: All Service and Parts Managers SUBJECT: Flood Damaged Appliances

General Confined Space Awareness

SL280UHV SERIES GAS FURNACE WARNING

Amendment: Combustion Appliance Testing Standards Removal. Proponent: Brett Dillon, Chair Standards Development Committee

Crux TM. Canister mounted stove for outdoor use SWE OPTIMUS CLEVER COOKING SINCE 1899

At Your Service Handbook. Your guide to natural gas service from Peoples Gas

Natural Gas Appliance Testing Action Guidelines (Non ESA/Low Income 5 )

INSTALLATION, OPERATION, AND SERVICE MANUAL RESIDENTIAL STORAGE TYPE GAS WATER HEATER

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

How To Get Natural Gas From Miller Gas Company

USER S INFORMATION MANUAL

Natural Gas Information Contents

NATURAL GAS SAFETY AT HOME

USING NATURAL GAS AT HOME Energy-Saving Tips and Safety Information

Diagnostics for Mobile Homes: HVAC

Standardized Terminology for Combustion Appliances and. Combustion Safety Testing

Calculate Available Heat for Natural Gas Fuel For Industrial Heating Equipment and Boilers

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

PIPELINE EMERGENCIES. Chapter 5 Gas Pipeline Operations. Michael Callan

Stay Safe Around Electricity and Natural Gas Teacher s Guide

Need Gas Service? Gas Service

Certain specific properties of compressed gases make them highly useful in various research activities.

CARING FOR YOUR WATER HEATER

Questar Safety Data Sheet

INSTALLATION, OPERATION, AND SERVICE MANUAL POWER VENT STORAGE TYPE GAS WATER HEATER MODELS PVG/PVCG

White Paper. Best Practices for Gas Monitoring in the Commercial Kitchen

! WARNING: RECREATIONAL VEHICLE (RV) Combination Carbon Monoxide and Gas Alarm USER S MANUAL Model ABOUT THIS ALARM

Air-Free Measurement of Carbon Monoxide Emissions from Gas Ranges: Analysis and Suggested Field Procedure

When Should Examination Preparation Begin?

CANADIAN WESTERN NATURAL GAS COMPANY LIMITED EXECUTIVE SUMMARY

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL


Nitrogen Blanketing for Methanol Storage and Transportation

Subpart XX Standards of Performance. Terminals. Environmental Protection Agency

MATERIAL SAFETY DATA SHEET. PRODUCT IDENTIFIER Carbon Dioxide, Refrigerated Liquid

Fuels Safety Program FS DIRECTOR S PUBLIC SAFETY ORDER

Tankless Water Heater

Instruction Manual for Residential Gas Water Heaters

Vehicle Maintenance Facilities Requirements for CNG and LNG Vehicles

Presented by: Rich Perry Marsh Risk Consulting

Gas-Fired, Residential Storage Type Water Heaters

EzFlex Combustible Gas Leak Detector Model EZ40

Natural Gas Safety What You Need To Know

ANSI/BPI-1200-S-2015:

orlando OWNER S MANUAL

G SPECIFICATION: GAS METER AND REGULATOR INSTALLATION REQUIREMENTS. 3 and Gas Yellow Book. REVISIONS: (See ) 1/15/14 5 Years

NATURAL GAS SAFETY. Your safety. Our priority Update

PIPELINE FUNDAMENTALS. texaspipelines.com

Residential Gas Water Heaters. Residential 30, 38, 40 and 50 Gallon

2010 Residential Water Heater Replacement Check List

Water Heaters. Residential 30, 40 and 50 Gallon

COMBUSTION. In order to operate a heat engine we need a hot source together with a cold sink

TWO BURNER PROPANE CAMPING STOVE

Fuel Gas Fitter. Legislation. Licensure Requirements. Regulatory Agency. Licensed, Certified, and Registered Occupations in New Hampshire 2015

Alarms. State of Wisconsin Rules ss (2) and (3) Comm Comm

Facility Operations Physical Safety Guidance Document

Safe Operating Procedure

TWO BURNER PROPANE CAMPING STOVE

How to Contact Us. By Telephone. Table of Contents. Billing Inquiries Welcome Letter Connect/Disconnect Service...

GAS LEAKAGE DETECTION & AUTO ON-OFF GAS SYSTEM

ENVIRONMENTAL STANDARDS FOR PETROLEUM OIL REFINERIES EMISSIONS. Standards for emissions from furnaces, boilers and Power Plant

GEORGIA DEPARTMENT OF COMMUNITY AFFAIRS (DCA) STATE CODES ADVISORY COMMITTEE (SCAC) CARBON MONOXIDE DETECTORS FOR SCHOOLS TASK FORCE

What to Expect From the Examination. How to Study the Plumbing Codes

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.

COMMERCIAL GAS WATER HEATER Glass-Lined Tank-Type Water Heater

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

William A. Lotz, PE, Direct Fired Heaters Can. Result in Excessive Moisture and Condensation. By William A. Lotz, PE Consulting Engineer Acton, ME

GAS SAFETY PRECAUTIONS

Water Heaters. Residential 30, 40 and 50 Gallon

Installation Instructions and Use & Care Guide

Hot Water Heating: Technologies and Use

Some Criteria for Choosing a Steam Boiler for a Microbrewery

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Ohio Gas Association 2011 Technical Seminar Lessons Learned From Liability Insurance Claims Paid

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service

natural gas Control control of of Natural Gas in Emergency Situations

Section Ambulance Service Charge. Effective July 1, 2014, the following bundled ambulance service charges shall apply:

Residential 30, 38, 40, 50 and 60 Gallon

E-gas Instant Gas Water Heaters

Upstate NY Recovery assistance information

Safe Method: Gas Safety in Catering Establishments

Material Safety Data Sheet

Factory owners must ensure the boiler is:

San josé OWNER S MANUAL

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

Instruction Manual for Residential Manufactured Home Gas Water Heaters

Transcription:

264 Natural Gas: What You Should Know Don MacBride Click to insert presenters Thursday, March 29, 1:15 to 2:15 p.m. Click to insert session day, date and time The Basics of Natural Gas Presented by: Don MacBride Safety and Technical Training Instructor Dominion East Ohio Gas Natural Gas Explosion Damage Natural Gas Explosion Damage Myths About Natural Gas 1. It s easy to burn! 2. Produces carbon monoxide when burned! 3. CO is an odorless, colorless, silent killer! What is Natural Gas? 95% Methane eat content of 850 BTU/CF Not hot enough to meet federal fuel gas guidelines Remaining 5% = Butane ~ 3200 BTU/CF Propane ~ 2500 BTU/CF Ethane ~ 1600 BTU/CF Fingerprint of natural gas 1

What is Natural Gas? (cont.) Methane + Ethane + Propane + Butane = Natural Gas eat value of 1000+ BTU/CF Dominion s average heat value ~ 1040 BTU/CF 1. Natural Gas is a compound of carbon and hydrogen. C 4 = C The Combustion Process Required for combustion: C O O O O 100% Flammable Range Natural Gas Concentration In Air Flammable Range 0% 15% 4% Upper Explosive Limit (UEL) Lower Explosive Limit (LEL) Odorant Natural gas is odorless An odorant is added to the gas stream as a primary safety measure in the industry The odorant aids in Leak Detection ti by Company personnel Allows customers to smell the gas if leaks develop inside the home Odorant levels are routinely checked by Company personnel Odorant Level vs. Flammable Range The odorant is added at a concentration so that leaks are detectable below 1% gas in air <1% 4% 15% 2

Flammable Range Natural Gas Concentration In Air 100% Let s Prove It Combustion Chamber Demo Depending on the concentration of gas inside a structure, consider the effect venting may have... and the possible risks! 15% 4% 0% The Combustion Process Complete Combustion Yields: C 2 O 2 O 2 O 2 O 2 CO 2 Water Vapor Carbon Dioxide O O O O 1100 0 F CO 2 Carbon Monoxide? Carbon Dioxide vs. Carbon Monoxide CO 2 CO Di = 2 Mono = 1 So, where does CO come from? Lack of oxygen can cause Carbon Monoxide to be produced during combustion Appliances in closet, no vents Plastic on windows / air tight homes Lack of maintenance of gas appliances 3

Not the silent killer 27 of Bird Nest MCF = 1000 Cubic Feet Standard home burns 20 MCF of natural gas per month. 1 MCF yields about 11.2 gallons of water vapor So: 20 MCF x 11.2 gallons 2O per MCF = >220 gallons of water vapor per month! Blocked Chimney s Do Not Kill It is a lack of Maintenance on the Appliances. Air Required for Combustion 30 cubic feet of air is required to burn just one cubic foot of gas. 30 times more air than gas!! Why? Air Required for Combustion (cont.) The Gas Burner... Because air contains only 20.9% oxygen. The balance of the air (79%) is nothing more than inert gasses that has nothing to do with keeping us alive. Natural Gas It has nothing to do with the combustion process. is a Vacuum! 4

Bunsen Burner Demo Why Aren t There More Accidents? It s ard to Burn Natural Gas! Must be present within it s flammable range in order to burn Odorant Added The natural gas industry adds an odorant to natural gas so that customers and the general public can smell gas at concentrations well below the lower explosive limit LP Meter Manifold Inside Our Residential System Meter Stop LP Meter Manifold - Outside MP Meter Manifold Service Regulator Meter Stop Meter Stop 5

The Meter Stop Curb Valve Curb Valve Turn-On Gas What s involved? Steps performed when turning on gas: Visually inspect the entire piping system for any open ends, proper materials and proper support. Inspect for Atmospheric Corrosion Check the entire piping system for gas leaks. Including performing an Interior Service Line Leak Survey. Light the appliances (furnace, water heater, stove clothes dryer, pool heater,gas light) Inspect the appliances for safe operation (check the ignition, flame, pilot safety, Chimney draft). Red tag the unsafe appliance(s). Check the piping system for atmospheric corrosion 6

2/21/2012 The Importance of Stressing Winterizing g a ome in Cold Climates 7

2/21/2012? Questions? 8

o Points of view, ideas, products, demonstrations or devices presented or displayed at the Ohio Safety Congress & Expo do not constitute endorsements by BWC. BWC is not liable for any errors or omissions in event materials. 9