Small stem Exeter total hip replacement: clinical and radiological follow-up over a minimum of 2.5 years



Similar documents
The Right Choice. Exeter. total hip system

Exeter. Surgical Technique. V40 Stem Cement-in-Cement. Orthopaedics

Clinical performance of endoprosthetic and total hip replacement systems

Revision of total hip arthroplasty using an anterior cortical window, extensive strut allografts, and an impaction graft: follow-up study

BONE PRESERVATION STEM

Metallurgical analysis of five failed cast cobalt-chromium-molybdenum alloy hip prostheses

Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology

VERSYS HERITAGE CDH HIP PROSTHESIS. Surgical Technique for CDH Hip Arthroplasty

Total Hip Joint Replacement. A Patient s Guide

From Department of Orthopaedics, Conquest Hospital, The Ridge, East Sussex. n N.A. Sandiford, FRCS (Tr/Orth), MFSEM, Specialist. Registrar.

Why an Exactech Hip is Right for You

Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y

An Alternative Conservative Approach to Hip Reconstruction

FEMORAL NECK FRACTURE FOLLOWING TOTAL KNEE REPLACEMENT

SCIENTIFIC PAPER Anterior Dislocation Following Primary Total Hip Replacement by the Posterior Approach Aetiology and Treatment

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

High-Flex Solutions for the MIS Era. Zimmer Unicompartmental High Flex Knee System

Metal-On-Metal Hip Resurfacing for Young Active Adults with Degenerative Hip Disease

on-metal Hips: Device Mechanics and Failure Modes

Anterior Hip Replacement

Prognosis of Total Hip Replacement

Total Hip Replacement

Analysis of Functional and Radiological Outcome of Total Hip Replacements in Rheumatoid and Osteoarthritis Patients *

femoral component. RESULTS AT A MINIMUM FOLLOW-UP OF 20 YEARS

The Journal of Arthroplasty

An Investigation of the Performance of the 3M Capital Hip System. July

Metal-on-Metal Hip Systems

Cormet Hip Resurfacing System

frequently asked questions Knee and Hip Joint Replacement Technology

CPT 12/14 Hip System. Primary Hip Athroplasty Surgical Technique

BIRMINGHAM HIP Resurfacing (BHR ) System PATIENT INFORMATION

CuttingEdge Hip Instrumentation Femoral Surgical Technique for Primary Press-Fit and Cemented Hip Implants.

Modular Dual Mobility Acetabular Components: An Important Extension of a Proven Approach to Hip Instability

A 15-year follow-up study of 4606 primary total knee replacements

Robotic-Arm Assisted Surgery

Imagine being an orthopedic surgeon and knowing that your patient s

Oxford Partial Knee. A Definitive Implant. Tibial Component. Anatomical shape for optimal bone coverage

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE. Health Technology Appraisal

Total Knee Replacement Specifications 2014 (01/01/2012 to 12/31/2012 Dates of Procedure)

P REPLACEMENT SURGERY

Your Practice Online

YOUR GUIDE TO TOTAL HIP REPLACEMENT

CPT 12/14 HIP SYSTEM LONG STEMS. Surgical Technique for Femoral Revision

Zimmer Gender Solutions NexGen High-Flex Implants

PUBLISHED VERSION PERMISSIONS. This document has been archived with permission from the editor of the Medical Journal of Australia, 26 April 2007.

Exeter X3 RimFit. Acetabular Cup Surgical Protocol

Primary V40 Surgical Protocol. Exeter. total hip system

Mid-term results for hip resurfacing in patients under 30 years old with childhood hip disorders

Minimally Invasive Hip Replacement through the Direct Lateral Approach

The Unhappy total knee replacement patient whose X rays look fine. Can we predict, prevent and treat. Myles RJ Coolican and Kunal Dhurve

Clinically Proven Fiber Metal Material. Power to choose advanced bearing technologies to match patient demands

Legg-Calve'-Perthes Disease The National Osteonecrosis Foundation

DEC V,(9/azO (c 0 j

TOTAL HIP REPLACEMENT: MODERN SURGERY FOR SEVERE ARTHRITIS OF THE HIP

Total Hip Replacement

Introduction to the Bertram Hip Spacer

Dr NG FU YUEN Associate Consultant Department of Orthopaedics and Traumatology Queen Mary Hospital

HIP RESURFACING ARTHROPLASTY

INSTRUCTIONS FOR USING THE KNEE SOCIETY RADIOGRAPHIC EVALUATION FORM

AN AUTOMATED SIZE RECOGNITION TECHNIQUE FOR ACETABULAR IMPLANT IN TOTAL HIP REPLACEMENT

Cementless total hip arthroplasty with a double chevron subtrochanteric shortening osteotomy in patients with Crowe type-iv hip dysplasia

TOTAL HIP REPLACEMENT

ACCOLADE II. Orthopaedics. Femoral Hip System. Surgical Technique

Semi-constrained total elbow arthroplasty for the treatment of rheumatoid arthritis of the elbow

TOTAL HIP REPLACEMENT FOR A LIFETIME: THE CEMENTLESS METAL ON METAL RECONSTRUCTION

Restoration Modular Cone Body/Conical Distal Stem Femoral Components Using the Restoration Modular Instrument System Surgical Technique

What factors determine poor functional outcome following Total Knee Replacement (TKR)?

Hip Resurfacing 2011 ORIGINAL ARTICLE. James W. Pritchett MD. Introduction. Abstract

PMA P Cormet 2000 Hip Resurfacing System

THE MEASUREMENT AND ANALYSIS OF AXIAL DEFORMITY AT THE KNEE

Hip Replacement Surgery Understanding the Risks

Uncemented total hip arthroplasty in patients less than twenty-years

Failure Mechanisms and Closed Reduction of a Constrained Tripolar Acetabular Liner

Computer Aided Engineering (CAE) Techniques Applied To Hip Implant


We compared the long-term outcome in 61

ULTRASONOGRAPHIC EVALUATION OF HIP DYSPLASIA: review. L. Breysem, MD DEPARTMENT OF RADIOLOGY

Radiologic Assessment of Total Hip Arthroplasty: Loosening

Hip Resurfacing (Re-Review)

Femoral Acetabular Impingement And Labral Tears of the Hip James Genuario, MD MS

Hip and Knee Revisions

Surgical Treatment of Bone Metastases in Patients With Breast Cancer

Joint Revision Surgery - When Do I Need It?

Kaiser Permanente. National Total Joint Replacement Registry. Liz Paxton Director of Surgical Outcomes & Analysis

HIP JOINT REPLACEMENT

COMPARISON OF DIFFERENT DIAGNOSTIC MODALITIES IN EVALUATION OF INFECTION OF TOTAL HIP ARTHROPLASTY. Summary

Patient Labeling Information System Description

Simplified surgery. Personalized performance.

Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology. Surgical Technique

Answers to commonly asked questions from patients with metal-on-metal hip replacements / resurfacings. Contents

Optimizing the cementation of femoral component in hip arthroplasty. PhD dissertation. Juozas Petruskevicius

Metal-on-metal (MoM) total hip arthroplasty

Bipolar Hemiarthroplasty in Juvenile Arthritis

Total hip arthroplasty (THA) through the anterior approach

Performance evaluation of CLS Brevius Stem with Kinectiv Technology

Valgus deformity and proximal subluxation of the rheumatoid elbow: a radiographic 15 year follow up study of 148 elbows

PERIPROSTHETIC IMPLANTS

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE

Malrotation Causing Patellofemoral Complications After Total Knee Arthroplasty

Hip Replacement. Department of Orthopaedic Surgery Tel:

Transcription:

Journal of Orthopaedic Surgery 2003: 11(2): 148 153 Small stem Exeter total hip replacement: clinical and radiological follow-up over a minimum of 2.5 years S Sivananthan, M Arif, DSK Choon Department of Orthopaedic Surgery, University of Malaya Medical Centre, Kuala Lumpur, Malaysia ABSTRACT Purpose. To evaluate the clinical and radiological outcome in patients undergoing small stem Exeter total hip replacement. Methods. A total of 46 small stem Exeter total hip replacements were performed on 44 consecutive patients (18 men and 26 women) attending the University of Malaya Medical Centre. The mean age at the time of operation was 58 years (range, 24 81 years). Of the 46 procedures performed, 35 were primary total hip replacements and 11 were revision operations, with aseptic loosening of the original implant being the main indication for revision. The main indications for surgery in primary cases were avascular necrosis and rheumatoid arthritis. Clinical and radiographic outcomes were assessed at 6 weeks, 12 weeks, 6 months follow-up, and annually thereafter. Postoperative cementing technique was also assessed. Results. The mean follow-up period was 4 years. The mean Oxford Hip Score improved from 46 points preoperatively to 17 points at the final follow-up examination. There were no revision operations, no implant breakages, and no excessive migration of the implants. The potential complications of implant failure due to smaller implant size and increased patient activity were not observed. Conclusion. Due to the smaller size of Asian femora, the small stem Exeter implant is a very useful development. This study suggests that it will perform as well as its larger counterparts. Key words: prosthesis implantation; total hip replacement; treatment outcome INTRODUCTION The Exeter total hip replacement prosthesis was first implanted in the autumn of 1970. In 1976, design modifications were made whereby the anteroposterior (AP) section of the stem was increased slightly, and 5 sizes were introduced with a 44 mm offset, together with 4 having a 37.5 mm offset. Three sizes were made with a 22 mm head for cases of congenital dislocation of the hip (CDH). At the same time, the original polished surface was changed to a matt finish, a step later found to be retrograde and this was reversed at the beginning of 1986. 1,2 Until 1986, all stems were made of 316L stainless steel. At the beginning of 1986, Address correspondence and reprint requests to: Dr Sureshan Sivananthan, Department of Orthopaedic Surgery, University of Malaya Medical Centre, Lembah Pantai 59100, Kuala Lumpur, Malaysia. E-mail: sureshansivananthan@yahoo.com

Vol. 11 No. 2, December 2003 Small stem Exeter total hip replacement 149 Orthinox, a high strength, low corrosion stainless steel was introduced. 3 Throughout these design modifications, the fundamental stem geometry remained unchanged. The double-tapered, collarless design allows distal subsidence of the stem within the cement mantle and therefore, more uniform transmission of load into the cement, and dynamic ongoing pressurisation. The Exeter implant has had 30-year follow-up with good results. We report our experience with the small stem Exeter total hip implant, which has been used in Malaysia since 1995. These smaller implants were introduced to the East Asian market in the mid-90 s to cater for the smaller build of the Asian population. Initially, the small CDH stem with a 35.5 mm offset was used. For some patients, this was still too large. Later the newly manufactured small stem Exeter total hip replacement implant was used. This implant is shorter and therefore, the angle of taper is altered. It is available with offsets of 30 mm, 33 mm and 35.5 mm (Fig. 1). Table 1 Distribution of small stem Exeter implant sizes used Offset size (mm) 30 33 35.5 Diagnosis Revision Avascular necrosis Rheumatoid arthritis Osteoarthritis Post-trauma Ankylosing spondylitis Developmental dysplasia of hip Number 24 14 8 Table 2 Indications for total hip arthroplasty * Number of THA in parentheses Number of patients 11.. 16. (17)* 7 6 2 1 1. (2)* PATIENTS AND METHODS From 1995 through 1999, 46 consecutive total hip arthroplasty (THA) procedures were performed on 44 consecutive patients at the University of Malaya Medical Centre, using the small stem Exeter total hip replacement implant (Stryker Inc, Warsaw, US). Stems with offsets of 30 mm, 33 mm and 35.5 mm were used (Table 1). The head size was 26 mm in all cases. Preoperative templating was performed in all cases. 30 37.5(1).. 2cm Figure 1 Small stem implant with 30 mm offset, compared to size-1 implant with 37.5 mm offset. The last author carried out all the procedures, using the anterolateral approach to the hip in all cases. Second generation cementing techniques were used, including cement restrictor, pressurised lavage, retrograde introduction of cement with a cement gun, and a proximal femoral cement pressuriser. Simplex P radiopaque bone cement (Stryker Inc, Warsaw, US) was used in all cases. Patients were mobilised and fully weightbearing as soon after the operation as possible. There were 18 male and 26 female patients. The mean age at surgery was 58 years (range, 24 81 years). The mean weight was 58 kg (range, 38 82 kg) and the mean height was 157 cm (range, 143 175 cm). There was a range of indications for surgery (Table 2), with a broad spread across the 3 Charnley categories 4 (Table 3). Clinical outcomes were assessed using the Oxford Hip Score 5 and radiological outcomes were assessed from AP radiographs of the pelvis, and lateral views of the affected hips. Stem failure was classified according to the criteria described by Gruen et al., 6 and the classification of cup failure by DeLee and Charnley 7 was used for the acetabular component. Cementing technique was assessed using the criteria described by Barrack et al. 8 Subsidence was meas -ured using a modification of the method described by Fowler et al. 3 All immediate postoperative and latest follow-up radiographs were digitised in black and white and stored in jpeg (DSC-F55V; Sony

150 S Sivananthan et al. Journal of Orthopaedic Surgery Table 3 Distribution of Charnley category 4 Category A B C Description Unilateral hip disease, no additional limitations Bilateral hip disease, no additional limitations Multiple joint disease, other disease limiting mobility Number of patients 12 24 8 Corporation, Tokyo, Japan), using a 3.3-megapixel Sony Cybershot camera. Osiris Imaging Software (version 4; University Hospital of Geneva, Geneva, Switzerland) was then used to measure alignment and subsidence of the implant. 9 RESULTS At a mean follow-up of 4 years, 2 patients had died. The cause of death in both cases was not related to the THA. One patient was lost to follow-up. All the remaining patients had a surviving THA. Clinical results The mean preoperative Oxford Hip Score was 46 (range, 36 51). The mean Oxford Hip Score at review was 17 (range, 12 24). The Oxford Hip Scores did not correlate with the radiological appearance or the age of the patient. There was some correlation with the preoperative diagnosis, however. Patients in Charnley category C had higher Oxford Hip Scores at followup than patients in Charnley categories A and B. There were no cases of deep infection. There were 2 dislocations. One patient dislocated twice, within one month of surgery. The other patient sustained dislocation of her left revision total hip replacement Figure 2 Barrack grade A. Figure 3 Barrack grade B.

Vol. 11 No. 2, December 2003 Small stem Exeter total hip replacement 151 Figure 4 Cup migration. and a crack fracture of the left femoral shaft while undergoing a total hip replacement, on the right side. She was treated with traction for 6 weeks and made a good recovery. Cementing technique Radiological assessment of the cement mantle in the postoperative radiographs showed that in 38 (83%) hips there was complete filling of the medullary cavity with cement (grade A) [Fig. 2]. In 8 hips there was slight radiolucency at the cement bone interface (grade B) [Fig. 3]. Alignment At the last follow-up visit, 25 stems were 1 Ο to 3 Ο in valgus and 5 stems were 3 Ο to 6 Ο in valgus. A further 15 stems were in neutral alignment, and one stem was 3 Ο in varus. Subsidence and radiolucent lines There was no migration at the cement-bone interface, measured from the greater trochanter to the proximal cement mantle. At the stem-cement interface there were 3 (7%) cases of vertical subsidence of the femoral stems of more than 2 mm but less than 5 mm. In the remaining cases (93%) the femoral stem had subsided by less than 2 mm. There were 7 (15%) cases in which radiolucent lines were present at the cement bone interface in Gruen zones 1, 2, 3, 6 and 7 on the AP radiograph. On the lateral radiographs, there were 3 (4.6%) cases of radiolucency at zone 8, at the level of the lesser trochanter. One case had a continuous radiolucent line at the cement-bone interface on the AP radiograph. The cases with radiolucent lines were revision cases and in the case with the continuous radiolucent line at the cement-bone interface, this was seen on the immediate postoperative radiograph as well. Thus it appeared that the radiolucent line was non-progressive in nature.

152 S Sivananthan et al. Journal of Orthopaedic Surgery There were 2 cases with radiolucency in zones 2 and 3 of the acetabulum. Both were revision cases. There was one case of cup migration (tilting). This patient had no clinical symptoms and was a case of primary THA (Fig. 4). There were no other radiolucent lines and no cement fractures seen in the acetabular component at follow-up. DISCUSSION Table 4 Distribution of acetabular cup sizes C up size (mm) Number (%) 44 48 52 24 (52) 19 (41) 3 (7) To the authors knowledge, this is the first report of early outcomes following THA with the small stem Exeter implant. Prior to the introduction of this implant in 1995, there had been a size mismatch between the standard Exeter stem and the majority of femora operated on in our institution. This finding was supported by morphometric studies in Hong Kong 10 and Singapore. 11 Data from these studies were used to design implants for the Asia Pacific region. Cemented THA has been extremely successful in restoring hip function and eliminating hip pain. This study corroborates the excellent early results seen with standard-sized cemented Exeter THA. 3,12 Finite element analyses, in vitro studies, and in vivo radiostereometric analyses of the Exeter stem have shown that it is a force-closed fixation design, utilising the taper slip principle, which is reliant on subsidence under load to obtain and maintain a tight fit. 2,13,14 Loading causes the taper to fit more snugly and when the load is reduced, during sleep for example, stress relaxation can take place, while the taper maintains the strain. It is expected that for satisfactory Exeter implants, the migration at the stem cement interface is initially rapid and then slows. 2,15,16 Early subsidence in this context is not synonymous with loosening, and this must be taken into account when interpreting the subsidence of the stems and the lucent zones reported in this series. 16,17 Therefore, previously published conclusions predicting femoral stem failure on the basis of subsidence of the stem relative to the femur cannot be used to predict failure in polished doubletapered designs such as the Exeter. 14,19 Moreover, the patients with stems that have subsided are functioning well and clinical studies have shown that distal migration of the Exeter stem does not cause poor longterm results. 3 It has also been shown that the distal migration of the Exeter stem occurs at the stem-cement interface and not at the bone-cement interface, thus protecting the bone-cement interface from osteolysis and aseptic loosening. In addition, distal migration of the stem, and cement creep expand the cement mantle and reinforce the cement-bone interface. In the authors view, a factor contributing to the favourable outcome seen over this follow-up period, is the smaller size of the implant, both in length and coronal width, that allows for a uniform cement mantle in the smaller femur. 20 22 The initial concerns regarding a smaller, shorter-stemmed implant, such as angulation, aseptic loosening and implant breakage have not occurred at a mean follow-up of 4 years. Therefore, the implant is clinically safe and can be used in the target population. The acetabular cup size was also smaller in this series (Table 4) and one case of cup migration was observed in this series, with tilting of the socket occurring after a period of 4 years. The initial operation in this case was for avascular necrosis and this patient is currently able to work as a nurse at our institution and is asymptomatic. Measurements of patient activity are important for proper understanding and evaluation of the results of any long-term study of THA. 23 However, patient activity was not objectively evaluated over time in this series. A significant percentage of the patients in this series were young and very active, and this would undoubtedly impact on the survivorship of the prosthesis in this group. 20,24 Osteoarthritis of the hip is relatively rare in Asia. 25 In this series, the 3 most common indications for THA were avascular necrosis, rheumatoid arthritis, and revision surgery. This will also influence the long-term outcome in this series as these indications inherently have a higher prevalence of morbidity compared to primary osteoarthritis, which is the principal indication for THA in Europe and North America. CONCLUSION Early results of THA with the small stem Exeter prosthesis appear promising. The potential complications of implant failure due to smaller implant size and increased patient activity have not materialised. The current evidence suggests that the small stem Exeter THA implant will perform as well as its larger counterparts.

Vol. 11 No. 2, December 2003 Small stem Exeter total hip replacement 153 REFERENCES 1. Middleton RG, Howie DW, Costi K, Sharpe P. Effects of design changes on cemented tapered femoral stem fixation. Clin Orthop 1998;355:47 56. 2. Crawford RW, Evans M, Ling RS, Murray DW. Fluid flow around model femoral components of differing surface finishes: in vitro investigations. Acta Orthop Scand 1999;70:589 95. 3. Fowler JL, Gie GA, Lee AJ, Ling RS. Experience with the Exeter total hip replacement since 1970. Orthop Clin North Am 1988;19:477 89. 4. Halley DK, Charnley J. Results of low friction arthroplasty in patients thirty years of age or younger. Clin Orthop 1975;112: 180 91. 5. Dawson J, Fitzpatrick R, Carr A, Murray D. Questionnaire on the perceptions of patients about total hip replacement. J Bone Joint Surg Br 1996;78:185 90. 6. Gruen TA, McNeice GM, Amstutz HC. Modes of failure of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 1979;141:17 27. 7. DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop1976;121:20 32. 8. Barrack RL, Mulroy RD Jr, Harris WH. Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review. J Bone Joint Surg Br 1992;74:385 9. 9. Ligier Y, Ratib O, Logean M, Girard C. Osiris: a medical image-manipulation system. MD Comput 1994;11:212 8. 10. Leung KS, Procter P, Robioneck B, Behrens K. Geometric mismatch of the Gamma nail to the Chinese femur. Clin Orthop 1996;323:42 8. 11. Low FH, Khoo LP, Chua CK, Lo NN. Determination of the major dimensions of femoral implants using morphometrical data and principal component analysis. Proc Inst Mech Eng [H] 2000;214:301 9. 12. Williams HD, Browne G, Gie GA, Ling RS, Timperley AJ, Wendover NA. The Exeter universal cemented femoral component at 8 to 12 years. A study of the first 325 hips. J Bone Joint Surg Br 2002;84:324 34. 13. Huiskes R, Verdonschot N, Nivbrant B. Migration, stem shape, and surface finish in cemented total hip arthroplasty. Clin Orthop 1998;355:103 12. 14. Shen, G. Femoral stem fixation. An engineering interpretation of the long-term outcome of Charnley and Exeter stems. J Bone Joint Surg Br 1998;80:754 6. 15. Alfaro-Adrian J, Gill HS, Murray DW. Cement migration after THR. A comparison of charnley elite and exeter femoral stems using RSA. J Bone Joint Surg Br 1999;81:130 4. 16. Alfaro-Adrian J, Gill HS, Murray DW. Should total hip arthroplasty femoral components be designed to subside? A radiostereometric analysis study of the Charnley Elite and Exeter stems. J Arthroplasty 2001;16:598 606. 17. Kwong LM, Jasty M, Mulroy RD, Maloney WJ, Bragdon C, Harris WH. The histology of the radiolucent line. J Bone Joint Surg Br 1992;74:67 73. 18. Iwaki H, Scott G, Freeman MA. The natural history and significance of radiolucent lines at a cemented femoral interface. J Bone Joint Surg Br 2002;84:550 5. 19. Yates P, Gobel D, Bannister G. Collarless polished tapered stem: clinical and radiological follow-up over 5 years. J Arthroplasty 2002;17:189 95. 20. Berry DJ, Harmsen WS, Cabanela ME, Morrey BF. Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components. J Bone Joint Surg Am 2002;84:171 7. 21. Crawford RW, Psychoyios V, Gie G, Ling R, Murray D. Incomplete cement mantles in the sagittal femoral plane: an anatomical explanation. Acta Orthop Scand 1999;70:596 8. 22. Chambers IR, Fender D, McCaskie AW, Reeves BC, Gregg PJ. Radiological features predictive of aseptic loosening in cemented Charnley femoral stems. J Bone Joint Surg Br 2001;83:838 42. 23. Dorey FJ, Amstutz HC. The need to account for patient activity when evaluating the results of total hip arthroplasty with survivorship analysis. J Bone Joint Surg Am 2002;84:709 10. 24. Boeree NR, Bannister GC. Cemented total hip arthroplasty in patients younger than 50 years of age. Ten- to 18-year results. Clin Orthop 1993;287:153 9. 25. Das De S, Bose K, Balasubramaniam P, Goh JC, Teng B. Surface morphology of Asian cadaveric hips. J Bone Joint Surg Br 1985;67:225 8.