OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS



Similar documents
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

Cooktop Low-Profile Ventilation Hoods

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Line to Refrigerator Ice/Water Dispenser

Advantium 2 Plus Alarm

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

12-Volt Negative Ground Installation Instructions

Instructions & Safety Information Models A220-20D and A220-20L Version 2

B-AIR BLOWER CUB POWER MODEL # CP-1

Owner s Manual Phoenix Solution. LGR Performance Amplifier

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Compressor Service & Maintenance Manual

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

SELECTION, APPLICATION AND MAINTENANCE

Installation and Operating Instructions (for chargers shown below)

Owner s Manual Phoenix D385

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

Leak Detection System

INSTALLER S & OWNER S MANUAL

INSTALLATION INSTRUCTIONS

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

Oil and Coolant Circulating Heating System. Model - OCSM

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

BroadBand PowerShield. User Manual

DUST COLLECTOR 70 GALLON, 2 HP

MODEL NO. QWIK JON 100/101/102 SYSTEMS DATE CODE: INSTALLATION INSTRUCTIONS DATE INSTALLED: PREINSTALLATION CHECKLIST

FOXAIR 60/50 ALL MODELS

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

LOBOY 16 AIR CONDITIONERS

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

MODEL INSTALLATION INSTRUCTIONS

Installation and Operation Guide for PD4000 Series Power Control Center

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

, User s Manual

INSTANT HOT WATER RECIRCULATING SYSTEM

ELECTRIC KNIFE SHARPENER

About this Manual. Support for Your Product

Ceiling Mount Air Handler Manual

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

How To Use A Cdm250 Digital Multimeter

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Innerduct Pressure Test Kit

STEALTH I DC MANUAL TECH SUPPORT WEB BLACK UNIT IS 24/36 ONLY

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Installation Instructions

Threaded Inline Air Heaters

Owner s Manual. ULTRA-POWER II ACCU-POWER & ACCU-POWER ONBOARD Solid State Fully Automatic Chargers. Manual Number Edition Code 0493B0101A

4 in 1 Air Compressor

Contractors Guide Central Inverter System Installation

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

MINI-BRUTE II HOT WATER POWER WASHER MODEL# MBII

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

Table of Contents TO OPERATE THE 12.0 VOLT POWER PACK: THIS OPERATES ONLY OFF THE UNIT S RECHARGEABLE BATTERY, NOT OFF YOUR VEHICLE S BATTERY.

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

Installation, Operation, Repair and Parts Manual

Installation and Operation Guide PD4600 Series Converter Replacement

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

CEILING CASSETTE FAN COIL UNIT

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

i410/i1010 AC/DC Current Clamp

Wolflite Safety Handlamp H-251E

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N

3 WATT LED SPOTLIGHT Model No. SLM

Portable Air Conditioner

Universal Vehicle Power Supply 9007AX01. Installation Instructions

12-Volt 10-Amp Regulated Power Supply

Manual. Solar Fountain Mobile Phone Charger

Installation and Operating Instructions (for chargers shown below)

MCR1900 Media Converter 19-Slot Chassis

Model 1210C Battery Powered Pump Shown. Description

Cambridge Electric Infared Fireplace User Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Transcription:

Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN CVF-8D15KIT CVF-8D25KIT Air Systems International, Inc. 829 Juniper Crescent, Chesapeake, Va, 23320 Telephone (757) 424-3967 Toll Free 1-800-866-8100 Fax No. (757) 424-5348 http://www.airsystems.com e-mail: sales@airsystems.com C US

2 The Saddle Vent Ventilation System Typical Saddle Vent Setup Procedure Place fan or blower a minimum of 5 ft. from manhole opening Blower or Fan Manhole Lid 90 Elbow Manhole opening Select a blower or fan based on environmental conditions and the size of the confined space. For information or guidance in selecting the proper set-up, please contact Customer Service. Universal Mount Saddle Vent STEP 1) Install 6 ft. duct on blower or fan STEP 2) Install 90 elbow on top of Saddle Vent STEP 3) Install duct on bottom of Saddle Vent STEP 4) Install universal mount on Saddle Vent and set in place with manhole lid for support STEP 5) Install duct from blower to 90 elbow STEP 6) Turn on blower or fan Warning: For explosive environments, follow ANSI/API 2015 and 2016 procedures WARNING: HAZARDOUS LOCATION OPERATIONS Use an explosion-proof or intrinsically safe blower or fan, conductive ducting, and the conductive Saddle Vent system. Attach all grounding wires and assure a complete circuit to the blower or fan in order to remove static charges. The Saddle Vent is a registered trademark of Air Systems International, Inc. The Conductive Saddle Vent is covered by U.S. and Foreign Patents

3 SAFETY PRECAUTIONS READ AND FOLLOW ALL INSTRUCTIONS BELOW All ventilation procedures should comply with federal, state, and local regulations. Air quality should be tested prior to ventilating a confined space. A purge chart is provided in this manual help assist in estimating the approximate time needed to ventilate confined spaces. Air quality should be tested continuously during confined space occupancy to ensure a stable atmosphere and worker safety as atmospheric conditions can change rapidly. Additional procedures and recommendations are available from federal, state, and local agencies. DO NOT operate these fan units in a vertical position or with the flange or guards removed. WARNING Fan and blower models with the EX or X designation are the only models approved for use in hazardous locations. If volatile or explosive vapors are suspected, use Air Systems explosion proof electric blower, Model SVB-E8EXP, explosion proof in-line fan, Model SVF-10EXP, explosion proof contractors fan, Model CVF-8EXP or Air Systems intrinsically safe pneumatic blower, Model SVB-A8. Note: For confined space ventilation in non-hazardous locations, use Air Systems confined space ventilation kit, Model SV-CUP. For hazardous locations use ventilation kit, Model SV- CUPCND along with one of the above explosion proof blowers or fans.

4 GENERAL SET-UP AND OPERATION FOR CVF-8AC, CVF-8AC50, AND CVF-8DC MODELS 1) Place fan in a clean fresh air environment. 2) Air quality of the confined space should be tested prior to ventilation. If air quality of the confined space is unacceptable, consult a trained professional. 3) Inspect fan for damaged or worn parts and ducting for air leaks prior to fan operation. 4) Install duct cuff to exhaust flange and secure. Keep bends and kinks in ducting to a minimum to maximimize air flow. If canister model is used, secure canister with connect straps, open lid and pull out ducting. Inspect for air leaks. 5) Set fan upwind from the work location and a minimum of 5 ft. from the manhole opening. 6) Connect fan to power source. AC versions require 115 VAC/60Hz, 15 amp service or 220 VAC/50Hz. Note: If an extension cord is required, the minimum recommended size is 14 AWG up to 25 ft. For further information refer to the National Electric Code Tables, Article 400. 7) Push on/off switch to I position on CVF-8AC and CVF-8DC models. PROBLEM POSSIBLE CAUSE SOLUTION Air intake blocked Turn fan off and clear debris from intake. Turn off and inspect fan blades, shaft, and housing for debris, damage, and loose screws. Possible internal damage Excessive vibration Note: Never run fan for extended periods without installing duct on the exhaust flange. Possible external damage Turn fan off and inspect for loose guards, broken welds, etc. Circuit breaker trips Voltage output insufficient Test outlet with volt meter. CVF-8AC series only Extension cord improperly sized Use 14 AWG extension cord up to 25 ft. Fan will not run CVF-8DC only TROUBLESHOOTING Blown fuse (DC version only) Battery connection Check and replace. Use only a 20A/32 VDC slow blow fuse. Ensure proper connection from battery clips to battery terminal posts. on battery pack units, recharge battery.

5 REPLACEMENT PARTS - AC VOLTAGE CONTRACTOR FANS MODEL CVF-8AC SERIES C US ITEM # DESCRIPTION PART # 1 DISCHARGE GUARD CVF-FG 2 INTAKE GUARD CVF-RG 3 DUCT CANISTER LATCHING POST CVF-POST 4 ON/OFF SWITCH CVF-SWITCH 5 POWER CORD ELCB012 6 DUCT CANISTER WITH 6 OF DUCT CVF-CAN6 7 DUCT CANISTER WITH 15 OF DUCT CVF-CAN15 8 DUCT CANISTER WITH 25 OF DUCT CVF-CAN25 9 115 VAC/60Hz MOTOR MTR043CN An optional GFI (Ground Fault Interrupter) plug can be supplied to comply with the 1996 NEC code requirement: Section 305-6. Order P/N ELCB013. This part number includes both the GFI plug and a 7 power cord. SPECIFICATIONS 1/3 HP (2.47 kw) electric, 115 VAC/60Hz, 2.6 amps, Single Speed, 3450 RPM, Thermally MOTOR TYPE Protected, Max. Ambient Temperature: 104 Fahrenheit OUTLET SIZE 8 Diameter (203mm) Free Air: 974 cfm FLOW RATES 15 ft. duct with one 90 bend: 786 cfm 15 ft. duct with two 90 bends: 661 cfm

6 REPLACEMENT PARTS - AC VOLTAGE CONTRACTOR FANS MODEL CVF-8AC50 SERIES ITEM # DESCRIPTION PART # 1 DISCHARGE GUARD CVF-FG 2 INTAKE GUARD CVF-RG 3 DUCT CANISTER LATCHING POST CVF-POST 4 ON/OFF SWITCH CVF-SWITCH 5 POWER CORD ELCB012 6 DUCT CANISTER WITH 6 OF DUCT CVF-CAN6 7 DUCT CANISTER WITH 15 OF DUCT CVF-CAN15 8 DUCT CANISTER WITH 25 OF DUCT CVF-CAN25 9 115 VAC/60Hz MOTOR MTR043CN50 MOTOR TYPE OUTLET SIZE FLOW RATES SPECIFICATIONS 1/3 HP (2.47 kw) electric, 220 VAC/50Hz, 1.2 amps, Single Speed, 3450 RPM, Thermally Protected, Max. Ambient Temperature: 104 Fahrenheit 8 Diameter (203mm) Free Air: 974 cfm 15 ft. duct with one 90 bend: 786 cfm 15 ft. duct with two 90 bends: 661 cfm

7 REPLACEMENT PARTS - DC VOLTAGE CONTRACTOR FANS MODEL CVF-8DC SERIES ITEM # DESCRIPTION PART # 1 DISCHARGE GUARD CVF-FG 2 12 VDC ELECTRIC MOTOR MTR044CN 3 FAN BLADE ASSEMBLY CVF-FAN 4 INTAKE GUARD CVF-RG 5 20 AMP SLOW BLOW FUSE ELF022 6 DUCT CANISTER LATCHING POST CVF-POST 7 ON/OFF SWITCH CVF-SWITCH 8 RED BATTERY CLAMP ELA083R 9 BLACK BATTERY CLAMP ELA083B 10 DUCT CANISTER WITH 6 OF DUCT CVF-CAN6 11 DUCT CANISTER WITH 15 OF DUCT CVF-CAN15 12 DUCT CANISTER WITH 25 OF DUCT CVF-CAN25 SPECIFICATIONS MOTOR TYPE OUTLET SIZE FLOW RATES 12 VDC, 1/4 HP, Thermally Protected, 3450 RPM, 20 amp/32 VDC Slow Blow Fuse 8 Diameter (203mm) Free Air: 848 cfm 15 ft. duct with one 90 bend: 702 cfm 15 ft. duct with two 90 bends: 590 cfm

8 REPLACEMENT PARTS - NON-CONDUCTIVE DUCT CANISTER MODEL CVF-CAN SERIES ITEM # DESCRIPTION PART # 1 RUBBER LATCH CVF-RHOOK 2 RUBBER LATCH SECURING HOOK CVF-UPOST 3 10-32 X 1 SCREW FS1032X100 4 10-32 X 1/2 SCREW FS1032X050 5 RED DUCT CANISTER, NON-CONDUCTIVE CVF-CAN-ND 6 RED DUCT ADAPTER, NON-CONDUCTIVE CVF-CANA 7 8 HOSE CLAMP SV-HC8 8 6 NON-CONDUCTIVE DUCT SVH-6 9 15 NON-CONDUCTIVE DUCT SVH-15 10 25 NON-CONDUCTIVE DUCT SVH-25 11 #10 STAINLESS STEEL FLATWASHER FW#10SS 12 RED DUCT CANISTER LID, NON-CONDUCTIVE CVFCANL 13 3/16 POP RIVET FR3/16XMAL 14 DUCT CANISTER LID STRAP CVF-BELT 15 10-32 NUT WITH NYLON INSERT FN1032ESN 16 PLASTIC LATCHING POST CVF-POST

9 WARRANTY DISCLAIMER Air Systems manufactured equipment is warranted to the original user against defects in workmanship or materials under normal use for one year from the date of purchase. Any part which is determined by Air Systems to be defective in material or workmanship will be, as the exclusive remedy, repaired or replaced at Air Systems option. This warranty does not apply to electrical systems or electronic components. Electrical parts are warranted, to the original user, for 90 days from the date of sale. During the warranty period, electrical components will be repaired or replaced at Air Systems option. NO OTHER WARRANTY, EXPRESSED OR IMPLIED, AS TO DESCRIPTION, QUALITY, MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR ANY OTHER MATTER IS GIVEN BY AIR SYSTEMS IN CONNECTION HERE- WITH. UNDER NO CIRCUMSTANCES SHALL THE SELLER BE LIABLE FOR LOSS OF PROFITS, ANY OTHER DIRECT OR INDIRECT COSTS, EXPENSES, LOSSES, OR DAMAGES ARISING OUT OF DEFECTS IN, OR FAILURE OF THE PRODUCT OR ANY PART THEREOF. The purchaser shall be solely responsible for compliance with all applicable Federal, State and Local osha and/ or MSHA requirements. Although Air Systems International believes that its products, if operated and maintained as shipped from the factory and in accordance with our operations manual, conform to osha and/or MSHA requirements, there are no implied or expressed warranties of such compliance extending beyond the limited warranty described herein. Product designs and specifications are subject to change without notice. Rev. 2, 12/98 Air leaks are not covered under warranty except when they result from a defective system component, i.e. an on/off valve or regulator or upon initial delivery due to poor workmanship. Air leaks due to poor delivery or damage will be covered under delivery claims. Minor air leaks are part of routine service and maintenance and are the responsibility of the customer just as are filters and oil changes.

10 NOTES:

11 NOTES:

Air Systems International, Inc. 829 Juniper Crescent, Chesapeake, Va, 23320 Telephone (757) 424-3967 Toll Free 1-800-866-8100 Fax No. (757) 424-5348 http://www.airsystems.com e-mail: sales@airsystems.com Printed in the U.S.A. Copyright Air Systems International, Inc. 2012 All Rights Reserved