Minitrend QX. Specification X SERIES - ADVANCED GRAPHIC RECORDERS. Security Stringent - Total Data integrity. Crystal Clear Display. Plus..



Similar documents
SIREC D Display Recorder

SIREC D Display Recorder

Minitrend GR GR Series Advanced Graphic Recorders Specifications

TREND MANAGER PRO V5 SOFTWARE SUITE and Database Management Tool Software

Multitrend Plus V5 Electronic Data Recorder

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500 Series Stand-Alone, Low-Cost Data Loggers

4-Channel Thermometer / Datalogger

TrendManager Suite. PC Application Software Configuration and Analysis Tool Specifications. 43-TV-03-09, June 2014

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

eztrend GR Advanced Graphic Recorder Specifications

USB-500/600 Series Low-Cost Data Loggers and Accessories

How to Use the PHF Digital Memory System

USB-500 Series Low-Cost Data Loggers and Accessories

Agilent 4339B/4349B High Resistance Meters

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Wahl C50 Calibrator FEATURES

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Noise Monitoring Software, version 7.0 Types 7802 and 7840

Digital multimeters DMG

Agilent 87421A/87422A Power Supply

EASY. SECURE. ADAPTABLE. Foxboro 6000 Series Data Management

1 Serial RS232 to Ethernet Adapter Installation Guide

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

EnerVista TM Viewpoint Monitoring v7.10

1. SAFETY INFORMATION

Duct Humidity Transmitter

Agilent 4338B Milliohm Meter

AXIS 262+ Network Video Recorder

NEW. EVEN MORE data acquisition and test stand automation

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

1.44 kw Programmable DC Power Supplies XLN Series

Accuracy counts! SENSORS WITH ANALOG OUTPUT

Temperature & Humidity SMS Alert Controller

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

CISCO PIX SECURITY APPLIANCE LICENSING

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

TrueAlarm Fire Alarm Systems

QuickSpecs. HP Wireless Keyboard and Mouse. Models

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

F453. TiF453. User guide 10/11-01 PC

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

UniOP epad33 and epad33t

PCS0100en Persy Control Services B.V. Netherlands

SCADAPack 530E 535E. remote Programmable Automation Controller

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Temperature Transmitters ZTT series

NETWORK ENABLED EQUIPMENT MONITOR

Panel Meters and Controllers Modular Panel Meter Type EDM 35

5000V Graphical Megohmmeter Model 5070

Data Loggers for Real Time Temperature Monitoring - WiFi

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Sympodium Interactive Pen Display

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

Hand-held thermometer Model CTH7000

DC Electronic Loads 8500 series

Cisco 2-Port OC-3/STM-1 Packet-over-SONET Port Adapter

X Series Application Note 43:

Pyrotracer Video C.A 650

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Multi-Function Ground

EZ-View Network Communications Guide

Job Aid Pre-Installation Information S8500 Media Server

Agilent P940xA/C Solid State PIN Diode Switches

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Eurotherm Chessell Graphic Data Acquisition Recorders. Ethernet Communication Data Historian, Reports, Real Time Monitor

Installation Qualification/Operational Qualification Protocols and Instructions. Experion Automated Electrophoresis Station and Software

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Agilent 8762/3/4A,B,C Coaxial Switches

Electronic Control Devices The European Product Catalogue 2007

Repeaters and Mimics Data Sheet

AT-S39 Version 1.3 Management Software for the AT-8024 and AT-8024GB Fast Ethernet Switches. Software Release Notes

FREJA 300 Relay Testing System

Power Supplies 3. SDN-P DIN Rail Series

Power Meter Series 700

Recording. Smart recording (depending on the camera models)

SNC-VL10P Video Network Camera

PowerCommand 500/550 Remote Monitoring System

Multifunction devices

SNMP Web Management. User s Manual For SNMP Web Card/Box

Nardalert S3 Non-Ionizing Radiation Monitor

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

For the best in Display Versatility, Analysis and Communications.. choose

Digital input modules

DIGICLIENT 8.0 Remote Agent Software

HWg-STE HWg-STE PoE MANUAL

TS8000. Profibus DP Option 8000/PB/00 HA Issue 1

This datalogger is ideal for the Food Industry where process profiling is crucial to production efficiency and energy use optimisation.

Transcription:

Minitrend QX X SERIES - ADVANCED GRAPHIC RECORDERS Specification 43-TV-03-10 October 2006 Crystal Clear Display 5.5 Digital Colour LCD (TFT) QVGA Resolution (320 x 240 pixels) Clear and intuitive operation Industrial rugged Touch Screen with rapid navigation Custom Screens Comprehensive Connectivity 10/100 Ethernet (DHCP), Web, Email, OPC Server FTP, TCP/IP and RS485 Modbus Protocol USB ports for keyboard and mouse Data Storage On-board non-volatile memory - up to 2GB Removable Compact Flash and USB storage No moving parts - all solid state Flash memory Security Stringent - Total Data integrity Password Protection - 21CFR Part 11 ESS - Extended Security System Plus.. Health Watch for preventative maintenance Remote Access - Advanced Software Data Analysis at your PC Independent Chart and Logging speeds Global Language Support Rapid review and replay of data at recorder Approvals - CE, CSA, UL, FM NEMA 4X / IP66 option Up to 50Hz (20 msec) Logging Up to 16 Analogue Inputs Remote Viewing Tool www.honeywell.com/imc 1

Recorder Function Honeywell s Minitrend QX recorder provides flexible electronic data acquisition and recording in a high functionality DIN standard 144mm format recorder. Up to 16 Analogue inputs with at least 70MB standard of available on-board memory plus additional removable storage media. The Minitrend QX uses a digital colour TFT LCD screen to provide easy to read displays with wide viewing angles for the best all around data viewing. The touch screen operator interface provides fast, easy access to the recorder menus making set up and data analysis quick and efficient. Navigation through the menus and text entry are direct and intuitive. Example of a recorder menu path from the Main Menu to Pen Scale configuration with clear rapid navigation Features Display 5.5 Colour Active TFT - with more than 256,000 colours makes it easy to interpret process data and take action with the intuitive bar charts, digital values, trends or customised displays. A screen saver function can be set from 1 to 720 minutes to extend the life of the backlight. Touch Screen - the heavy duty durable touch screen provides easy data entry and rapid navigation though the menus. Help Files - A complete contextual help system can be accessed and visualised on the screen of the recorder. Communications Ethernet Connectivity - the Ethernet (DHCP standard) connection, with support for various protocols, provides unlimited connectivity to local area networks (LANs). The standard Ethernet interface makes networking of the recorder to a LAN or the world wide web fast and convenient. Dynamic Host Configuration Protocol (DHCP) automatically acquires the settings (IP address) for network communications from a DHCP server. RS485 Modbus - the RS485 connection allows process data to be transferred to other devices, or to record data received in MODBUS RTU protocol (slave mode only). Simple Network Time Protocol (SNTP) - The recorder can be synchronised over the ethernet network via a SNTP client or synchronise other recorders via a Server. 2 www.honeywell.com/imc

Web Server - with the recorder connected to a LAN, all process variables, alarm and messages can be viewed from an internet browser; values are automatically refreshed. Data Storage Internal Data Storage - 70MB to 400MB of expandable internal non-volatile flash memory is available for data storage and chart history. Internal memory / Logging rate = 1 sec Pens 70MB 180MB 400MB 890MB 1850MB 8 24days 61d 137d 301d 622d 16 12d 30.5d 68.5d 150d 311d 32 6d 15d 34d 75d 155d Data Export - Removable compact flash and USB flash storage device provides multiple data storage alternatives. Data is stored in a secure binary encrypted format, with the recorder s configurations, providing added security of the data files. Removable Compact flash and USB flash storage devices External USB Devices The recorder has two USB host ports, one front and one at the rear, for attaching external USB devices such as a keyboard, mouse or a USB data storage key. The keyboard and mouse can be used to navigate the recorder s screen along with text entry. Remote Viewer Extends the user interface of the recorder onto the desktop PC. Providing remote viewing of the unit launched from a web browser. Full remote control is available as an option. Compatible with Microsoft Internet explorer 6 and higher. Security Total Data Integrity - data is stored in secure encrypted files making it easy to retrieve the data dependent on process information. Data is automatically recognised without having to remember file names. Password Protection - Up to 4 levels of password protection with up to 50 different users are available. Multiple levels of password protection and an audit trail of actions enhance the security of the data. Extended Security System (option) - ESS provides extended features including entry of unique User ID s and associated passwords, time-out of password entry, password expiration, and traceability of user actions. ESS is compatible with the requirements of 21CFR part 11. Events Certain conditions or operations can be set up and logged according to the time and date of the occurrence. Subsequently events can be reviewed in a list or represented on a graph. Batch Batch enhances the management of data collected in non-continuous process, known as batch processing, used in thermal treatment, sterilisation, food processing and chemical reactions. Other Standard features.. CE Mark - Conformity with 73/23/EEC, Low Voltage Directive and 89/336/EEC EMC Directive. Soft Alarms - 6 "software" alarms per pen are easily set up to display and record selected out-of-limit conditions. These can be tied to the relay or digital outputs to activate the user s external equipment. Common Relay Output - A separate relay alarm output at the rear of the unit can be set up as an alarm output. Communications - the recorder supports FTP, Modbus TCP/IP (slave mode), Web and Email over Ethernet (DHCP standard) communications port and Modbus RTU (slave mode) via an RS485 port. USB ports allow the use of an ASCII barcode reader. Email sent to your network connected PC triggered by an Alarm or an Event. Independent Display Chart Speeds and Logging rates - logging rates can be programmed completely separate from the chart display speed, allowing the data to be displayed and stored at the rates that best suits the application. Language Support - standard language prompts for English UK & US, French, German, Italian, Spanish, Portuguese, Brazilian, Polish, Slovakian, Czech, Turkish, Romanian, Hungarian and Russian. Logarithmic Scales - all displayed scales can be set as linear or logarithmic. Enclosure rating - standard NEMA 3 / IP54 type front face protection. NEMA 4X / IP66 available as an option. Pulse Inputs - The 8 Digital I/O option card has 4 channels that can be set as pulse inputs (first 4 channels). The operating frequency for pulse inputs on the Digital I/O card is 1kHz max. www.honeywell.com/imc 3

Fuzzy Logging - this standard feature provides a unique method to increase the storage capacity of the recorder. The data is monitored to determine changes in process data; if no changes are observed data is logged periodically. If data is changing rapidly, it is recorded normally at the programmed rate. By not logging data that is static, data compression of up to 100:1 or more can be achieved saving valuable memory. Security tag - wire seal provision that provides added security to seal the front door and rear wiring when using optional rear cover to prevent undetected entry to these areas of the recorder. USB Ports - Front and rear USB host ports for data and setup transfers or remote screen through these ports. Use these ports to attach external devices (keyboard or mouse) for direct interfacing with the recorder. Replay with Zoom - Select replay mode and zoom-in on a specific area on the screen. The data can easily be replayed at the recorder with the ability to zoom. The touch screen makes it fast to review and analyse historical data. A "Jump" function allows you to go from any message list directly to the trend showing the occurence of the alarm. QX Standard Screens Up to 20 screens displaying multiple combinations of Charts, Bars and Digitals can be configured, 6 examples below. Chart and Digitals 8 Digitals 8 Horizontal bars Vertical chart, 4 horizontal bars, 4 digitals Horizontal chart, 8 vertical bars, 8 digitals 8 Vertical bars Options - Hardware Alarm Card - 4 or 8 outputs relay contacts SPCO 240V, 8 Digital I/O or 16 Digital I/O - SPNO 24VDC. Programmable alarm set points can be configured to activate up to 16 outputs. Analogue Output - 2 or 4 outputs available per card. Output type: 0-20mA or 4-20mA. Nema 4X / IP66 - Nema 4X / IP66 protection available as an option. Portable Recorders - Portable cases available as an accessory item. Digital Input - Two digital input options are available: 2 inputs on 8 channel Alarm card, 8 inputs on 8 Digital I/O card and 16 inputs on a 16 Digutal I/O card. The digital inputs allow users to initiate, from a remote location via a dry contact closure, selected recorder functions. Pulse Counting - Up to four counting inputs per board, are available to count signals up to 25 khz (max. 2 cards). Approvals - CSA, UL and FM CL1 Div 2 approvals. 24VAC/DC or 48VDC Power Supply - 20 to 50VDC / 20 to 30VAC 24VDC Transmitter Power Supply - can supply up to 200mA to external transmitters. Print Support - Network printing from status, message and replay screens. Plus screen capture facility of process screens instantly using a basic USB standard PCL printer. 4 www.honeywell.com/imc

Firmware Credit System The credits system is a flexible way of adding to the recorder features without having to upgrade the firmware. Simply purchase a number of credits to cover your current and possibly future requirements and the recorder will be delivered with the credits loaded. The credit value in each recorder is displayed in the Factory menu. Select the Options button and by activating and de-activating the options in the credit list, the recorder will change its functionality. Any greyed out options on the list will mean there are not enough credits available for that feature on the recorder. Credits can be applied as desired to the Firmware functions until the total number of credits purchased has been used up. Additional credits can be purchased later if new features are to be activated and not enough credits are available to support these additional functions. On Table V of the Model Selection Guide on page 13 select what firmware credits are required. Details of each firmware option are listed here in Table 1 Firmware Options. Table 1: Firmware Options Firmware option Credit value Description Full Maths 4 Full (Block) Math - this can handle math expressions that can consist of expressions up to 100- characters in length. (Note 1) Full Maths with Scripting 6 A powerful multi-line scripting ability available to solve complex state based applications. Eg.: If.. X happens, then Y will happen, else.. Z will occur. (Note 1) Events 6 Events are certain conditions or operations that can be set up and logged according to the time and date of an occurrence. Subsequently events can be reviewed or displayed on a graph. Events can produce the following actions: Mark on Chart, start/stop Logging, Start/stop/reset Totalisers, Set/clear Relay (Digital), Acknowledge alarm, trigger an Event, Screen change, E-mail a message and Reset max/mins. (Note 3) Fast Scanning mode 5 For fast processes, the scan rate and recording of the data can be set for up to 50 times per second (20ms) for up to 8 inputs. Totalisers/ Sterilisation calculation 4 Each pen can be associated with a totaliser. Using extra pens, the totalised values can be displayed and recorded; multiple totals can be calculated out of the same variable (weekly, monthly, etc.). The totaliser function can handle Fo and Po sterilisation calculation. (Note 1) Custom Screens 4 Import custom built screens that have been created in X Series Screen Designer. (Note 2) Health Watch/ Maintenance 2 The recorder keeps track of important life actions for improved diagnostics and preventative maintenance notification. Including Powered On, Last powered On, Time On since power up, Total On time, Total Off time, Longest Off time, Lithium cell life, Backlight life left at 100% brightness, Compact Flash insertions, Hi/Lo CJC value (Hi & Lo temps), Analogue In last factory/user cal, Relay operations. Print Support 2 Network printing from status, message and replay screens. Pluse screen capture facility of process screens instantly using a basic USB standard PCL printer. Batch 3 The Batch function allows the user to segment portions of data for further analysis. Batch controls include Start, Stop, Pause, for viewing, Resume and Abort. Groups 2 Groups of Pens can be specified and named with a Group number to display on the recorder. Remote Viewer 3 Extends the user interface of the recorder onto the desktop PC. Providing full remote control of the unit launched from a web browser. Email 3 Setup email accounts to send the following: When an Alarm is triggered or an Email can be sent as a part of an Event occurring, such as: Alarms - In/Out/Ack, Totaliser Start, Stop or Reset, Digital Inputs On, Off or State change, TC Burnout on a specific Analogue Input channel, Scheduled Events Once, Interval, Specific days, Month End. OPC Server 8 OPC (OLE for Process Control) - Software application for realtime interfacing between servers and clients. OPC is a software standard that defines common interfaces for data exchange between devices such as recorders, controllers, PLC s and Windows based applications Extra Pens 2 4 extra pens to store and display totalised values, results of calculations, etc. Maximum is up to 16 extra pens for the QX recorder. Notes (1) Additional pens ( Extra Pens ) can be used to display and store the results of calculations, totalisers, variables imported via communications, or to store values. (2) Custom Screens must be built using X Series Screen Designer (.lay). Screens from V5 Screen Designer cannot be imported (.lyt). (3) Event markers are required to automatically reset the totalisers, for example on a periodic basis or on an external condition. (Not necessary if the totalisers are reset manually). www.honeywell.com/imc 5

The TrendManager Pro Software Suite The TrendManager Pro Software Suite complements the capabilities of the X Series recorders by providing the benefits of viewing, configuration, network communications, database management, data analysis and report generation using a personal computer. It ties the process together, providing for real-time communications with the recorders through a Local Area Network (LAN). TrendViewer TrendViewer - is the standard software provided with the recorder that displays and prints data imported from the storage media used by the recorder. TrendManager Pro TrendManager Pro is an advanced data analysis/archiving software package, providing full configuration of the recorders. TrendManager Pro is a stand-alone package that delivers to the user total recorder configuration, allowing the user to archive, graph, print and export data. TrendManager Pro also allows files to be exported using comma separated variables (CSV) format, that can be imported in most computer software. TrendServer Pro TrendServer Pro is a fully network aware software package for real-time viewing and archiving of data with communications to the recorder. It supports all the capabilities of TrendManager Pro plus real-time data acquisition and web browser access. TrendServer Pro provides secure multi-level, multi-user access to the recorder data by various departments with security. Standard features of TrendServer Pro include data archive tools, graphing, print import and export data facilities. TrendServer Pro with OPC Server - provides the same functions as the TrendServer Pro but includes the added function of an integrated OPC Server to allow easy interfacing to third party HMI software packages that support an OPC Client. This provides a real-time interface between servers and clients. Database Management Tool Database Management Tool - this software application works with TrendManger Pro and TrendServer Pro to provide safe administration of data with tools to archive, sort, move, copy and delete the data stored in local and remote databases. The Database Management Tool software is supplied with TrendServer Pro. X Series Screen Designer X Series Screen Designer - is a separate software package that enables the user to design unique display layouts for transfer to the recorder s screen. Screen layouts can be created using any combination of indicators such as Trending Charts, Digital Panel Meters (DPM) and Bar graphs. Flexibility allows each type of indicator to have elements of its appearance changed to create an individual presentation. The X Series Screen Designer software package is compatible with Minitrend QX and Multitrend SX recorders. Layouts can be transferred on to single or multiple recorders of the same type, which contributes to continuity and standardization of process data. For use with X Series recorders only. Minimum System requirements for TrendViewer, TrendManager Pro and X Series Screen Designer: 1GHz Pentium processor or higher CD-ROM drive Monitor screen resolution 1024 x 768 recommended minimum, high colour Windows 2000, XP Minimum System requirements for TrendServer Pro: 1GHz Pentium processor or higher CD-ROM drive Monitor screen resolution 1024 x 768 recommended minimum, high colour Windows 2000, XP 512 Mbyte of RAM (min 512 Mbyte recommended) 512 Mbyte of RAM (min 512 Mbyte recommended) 16 bit colour graphics, 24 bit recommended (Screen Designer only) TCP IP installed 50 Mbyte free hard disk space 2 Gbyte Hard-drive free disk space A mouse Flash card reader or USB port A mouse Flash card reader or USB port 6 www.honeywell.com/imc

Specification Digital indicators and Display Display Update Rate Status Display Communications Mathematics Front and Rear USB Ports Standard Screens and Custom Screens Data Storage Power Requirements Common Relay Output (SPNC) Battery Password Protection Languages Design Attributes Display size and Type: 5.5 diagonal, Digital Colour LCD (TFT) with Touch Screen Industrial grade with brightness adjustment and wide viewing angle Resolution: QVGA (320 x 240 pixels). Screen Saver: Set in minutes from 1 to 720, can be set to dim the screen or to switch off. Brightness adjustment: Adjustable between 10 and 100%, default set to 80% brightness. Backlight life time: 55,000 hours to half brightness when used at 100% (86,000hr if used at 80%). Maximum luminosity 400 cd/m 2. Touch Screen life: 1,000,000 touches Display values updated every second A status bar, at the top of the recorder s screen, displays the real-time icons of the recorder status, such as Recording Time left and alarm active. Ethernet 10/100 base - T with RJ45 connector supporting Modbus/TCP, FTP, Internet, DHCP or fixed IP address. RS485 Modbus RTU (up to 115200 Baud Rate). Basic Maths include Add, Subtract, Multiply, Divide, Modulo and power. Full Maths and Scripting (option) support up to 100 character free form math expression for each pen. For example SINE, COS, TAN, Log, Parenthesis (eg. A1 + A2), comm variables, free memory, and access to any data item variable (A1, P1, D1 etc.). USB host ports front and rear for data and setup transfers through these ports. External devices keyboard or mouse, Barcode reader, or external mass storage device. (USB 1.1 compliant) Fully programmable display values in engineering units. Time & date stamp on every division. Sets of Standard screens are available to display data on a chart, digital reading, bargraphs or numerous combinations thereof. Screen properties can be modified on the recorder and customised to suit. Custom screens created in the Screen Designer software can be imported into the recorder for specialist applications. Custom Screen firmware option is required. Digital values displayed include alarms on bars, engineering units, pen name, tag, time and date, 20 character description and totalised values. Removable Media: Compact Flash card, supports up to 4.0 Giga bytes. Local Mass Storage Options: USB memory key - up to 2Gb, USB hard drive - up to 120Gb, Internal Data Buffer: Non-volatile. 70MB (16 million acquisition values) upwards to 1850MB (up to 400 million points) Setup and screens: Stored internally on non-volatile memory Manual Saving: Data saving by inserting compact flash card or USB memory stick Data Saving Period: Related to log rate, number of pens, totals and alarms. Each pen is capable of its own independent storage rate. (20 ms to 60 h). Data Format: Honeywell binary encoded format Recycling Mode: Internal memory has FIFO (First In First Out) capability where the newest data over-writes the oldest data. Voltage (VRMS): 100VAC to 250VAC (auto select). Frequency: 50/60Hz Power Consumption: <40W. Optional instrument power Voltage: 20 to 55VDC/20 to 30VAC. Power Consumption: < 40 watts NC common alarm relay: Two contacts, normally open when the recorder is powered (no active alarms). Rating 24V, 1 Amp. Battery backed up for clock, Lithium battery Type 6032, 3.0V 10 years life (Recorder powered), 4 years life, typical (Recorder unpowered). Multiple Administrator control of password setup and management with four levels of password protection for Engineer, Supervisor, Technician, and Operator. Up to 50 different users are available. Password protection restricts user entry to the recorder set up and specific screens. Engineer Highest access to all levels, Supervisor, Technician and Operator. Supervisor 2nd highest level including Technician and Operator access Technician 3rd level including Operator access Operator 4th and lowest level of access. English UK & US, French, German, Italian, Spanish, Portuguese, Brazilian, Polish, Slovakian, Romanian, Hungarian, Czech, Turkish and Russian Temperature Units C, F, K www.honeywell.com/imc 7

Specification Recorder Identification Clock Alarm Set Points Data Replay Mode Display Chart Speeds Messages Screen CE Conformity (CE Mark) Immunity Product Classification Enclosure Rating Installation Requirements Design Attributes Status bar: Alternately displays Recorder ID and Recorder Screen Name. Displays Time and Date. Accuracy: ±29ppm (±1 minute/month) @ 25 C. Summer/Winter manual or automatic time adjustment or via communications. SNTP Client and/or Server included for synchronising over Ethernet. 6 per pen integral soft alarm set points easily set by user to announce selected out of limit conditions; user can select if an alarm triggers a change in the screen background colour. Alarm triggers can be set for Hi, Lo, Deviation (latched or unlatched) for alarm acknowledgement. Alarm Damping 1 sec to 24 Hours; Hysteresis - +/- 100% of pen scale Common relay output: 1A 24V, can be activated on any alarm. Data replay facility on chart displays at normal, fast or slow speeds with zoom and cursor. Chart rates: 1 mm/hour, 5 mm/hour, 10 mm/hour, 20 mm/hour, 30 mm/hour, 60 mm/hour, 120 mm/ hour, 600 mm/hour, 1200 mm/hour, 6000 mm/hour. Combinations of rates can be mixed and chart speeds can be set independently for each chart. Display speeds are independent of logging rate The message screen displays system information and records any setup activity that has been changed. It also provides warning and error message updates, lists alarm activity and will display user defined marks on a chart. This product conforms with the protection requirements of the following European Council Directives: 73/23/EEC, the Low Voltage Directive, and 89/336/EEC, the EMC Directive. Conformity of this product with any other CE Mark Directive(s) shall not be assumed. Complies with EN61326 Class I: Cord Connected, Panel Mounted Industrial Control Equipment with protective earthing (grounding). (EN 61010-1) Front panel designed to NEMA3 / IP54 (Optional NEMA 4X / IP66) Category II: Overvoltage (EN 61010-1) Pollution Degree 2 EMC Standards Safety Emissions - EN61326 Class B Immunity - EN61326 Industrial Levels Complies with EN61010-1: 2001. Panel Mounted Equipment, Terminals must be enclosed within the panel. Specification Number of Inputs Input Types Minimum Input Span Burnout (T/C) Cold Junction Compensation Input Resolution Input Impedance Source Impedance Square Root Extraction Sensor Compensation Analogue Inputs 4, 6, 8, 12 or 16 input channels mv, V, ma with external shunt (provided as standard), Thermocouple, RTD and ohms Range is fully configurable with span limitation of the operating range selected with 4% under range to 4% over-range capability (50V Range 2%) Active (High or Low), Passive, and Health watch/maintenance (option). Internal compensation with the ability to manually adjust values, External Input for compensation, External CJC value specified 0.0015% (16 Bit ADC) Current loop resistance: 10 ohms, use ±0.1% external resistor. Volts >1MΩ, all other >10MΩ T/C and RTD: 100 ohms per lead maximum (CU10 = 15 ohms) Available as standard on every input type Single point and Dual point 8 www.honeywell.com/imc

Specification Input Sampling Rate Scales, Linear & Logarithmic Input Isolation Noise Rejection (at 50/60Hz) +/-2% Analogue Inputs Recorder has 2 available slots with up to 8 analog inputs each; the input sampling rate is dependent on actuation type. All Inputs: 100mS (10Hz), 200mS (5Hz), 500mS (2Hz) Fast Sampling: 20mS (50Hz) - ma, mv, Volts and Ohms only Normal and Scientific notation Decimal Point automatic or programmable Engineering units, user definable (10 characters) Logarithmic Decade limits: -38 min, to +38 max, (recommend up to 20 decades on one screen to ensure clarity) 300VAC channel-to-channel, channel-to-ground Common mode: 2Hz = -120dB, 5Hz = -120dB, 10Hz = -120dB Normal Mode: 2Hz = -85dB, 5Hz = -80dB, 10Hz = -48dB Specification Logging Method Logging Types Logging Rate Fuzzy Logging Logging Sample, Average, Min/Max - can be set independently per pen Continuous, Fuzzy From 20 msec. to 60 hours per pen A secure data storage technique which delivers data compression ratio of 100:1 or more; self teaching, storing the data at a variable rate to match the process Specification Enclosure/Bezel Mounting Panel Dimensions Weight Colour Wiring Connections Physical Parameters Zinc plated steel case with high impact resistant polycarbonate bezel; scratch resistant lens. NEMA 3 / IP54 protection rating standard. Optional NEMA 4X / IP66 (Front face only) Unlimited mounting angle. For the best view of the display the viewing angle should not exceed 55 from the left or right, 40 looking down and 50 looking up at the recorder display. Mounting adjustable for panel thickness of 2mm to 20mm. Adapter kits available for covering existing panel cutouts. W: 144mm (5.67 ), H: 144mm (5.67 ), D: 200mm (7.87 ). Additional 80mm (3.15 ) clearance recommended for a straight type power cable and signal connectors. Cutout 138 x 138mm (5.43 x 5.43 ) 2.7 Kg (6lb) max. Bezel: Black IEC Power Plug. Removable terminal strip for input and alarm connections www.honeywell.com/imc 9

Input Range Performance and Accuracy Input Actuation (Linear) Range Accuracy Temp. Stability +/- Input Impedance Millivolts DC -5 to 5, -10 to 10, -25 to 25, -50 to 50, -100 to 100, -250 to 250, -500 to 500, -1000 to 1000 +/- 0.2% F.S. +/- 0.1% F.S. +/- 0.1% F.S. >10M ohms >10M ohms >10M ohms Volts DC -0.3 to 0.3, -0.6 to 0.6, -1.5 to 1.5, -3 to 3, -6 to 6, -12 to 12, -25 to 25, -50 to 50 +/- 0.1% F.S. +/- 0.1% F.S. +/- 0.1% F.S. >1M ohms >1M ohms >1M ohms Milliamps ** 4 to 20, 0 to 20 +/- 0.2% F.S. Ohms, 200 0 to 200 +/- 0.1% F.S. Ohms, 500 0 to 500 +/- 0.1% F.S. Ohms, 1000 0 to 1000 +/- 0.1% F.S. Ohms, 4000 0 to 4000 +/- 0.1% F.S. Input Actuation (Thermocouples) Range Reference Accuracy Temp. Stability +/- F C +/- F +/- C B* 500 to 1000 1000 to 3300 260 to 538 538 to 1816 8.1 4.0 4.5 2.2 E* -454 to -328-328 to -94-94 to 1832-270 to -200-200 to -70-70 to 1000 21.6 3.1 1.3 12 1.7 0.7 J* -346 to 32 32 to 2192-210 to 0 0 to 1200 3.1 1.2 1.7 0.7 K* -454 to -94-94 to 2502-270 to -70-70 to 1372 36 1.8 20 1 R* -58 to 500 500 to 1202 1202 to 3214-50 to 260 260 to 650 650 to 1768 6.7 2.7 2.0 3.7 1.5 1.1 S* -58 to 500 500 to 1832 1832 to 3110 3110 to 3214-50 to 260 260 to 1000 1000 to 1710 1710 to 1768 5.9 2.7 2.0 2.5 3.3 1.5 1.1 1.4 T* -454 to -346-346 to 752-270 to -210-210 to 400 9.7 1.8 5.4 1 L* -328 to 32 32 to 1652-200 to 0 0 to 900 2.2 1.3 1.2 0.7 G* (W_W26) 32 to 212 212 to 600 600 to 1526 1526 to 2759 2759 to 4199 0 to 100 100 to 316 316 to 830 830 to 1515 1515 to 2315 45 11.2 5.0 3.1 5.0 25 6.2 2.8 1.7 2.8 C* (W5, W26) 32 to 356 356 to 2228 2228 to 4199 0 to 180 180 to 1220 1220 to 2315 4.5 3.6 6.7 2.5 2 3.7 M* (NiMo-NiCo) (NNM90) -58 to 698 698 to 2570-50 to 370 370 to 1410 2.0 1.4 1.1 0.8 N* (Nicosil Nisil) -328 to 212 212 to 2372-200 to 100 100 to 1300 5.8 2.0 3.2 1.1 Chromel/Copel* -58 to 1112-50 to 600 1.1 0.6 P* (Platinel) 32 to 2534 0 to 1390 2.5 1.4 D* 32 to 356 356 to 3344 3344 to 4515 0 to 180 180 to 1840 1840 to 2490 6.3 4 11.7 3.5 2.2 6.5 10 www.honeywell.com/imc

Input Actuation (Linear) Range Accuracy Temp. Stability +/- Input Impedance PT100 α = 0.00385-328 to 1562-200 to 850 1.1 0.6 PT200 α = 0.00385-328 to 1562-200 to 850 1.1 0.6 PT500 α = 0.00385-328 to 1562-200 to 850 1.1 0.6 PT1000 α = 0.00385-328 to 1562-200 to 850 1.1 0.6 100 ohm Nickel -76 to 356-60 to 180 0.9 0.5 120 ohm Nickel -112 to 500-80 to 260 0.5 0.3 Cu10-328 to 500-200 to 260 5.5*** 3*** Cu53 32 to 302 0 to 150 0.5 0.3 Reference Temperature: 22 C Reference Sample Rate: 2Hz (500msec) Reference Humidity: 65% RH +/-15% Long term stability: 0.2%/year * Does not includes reference junction calibration of ±1.0 ºC using the standard ice bath method of calibration. Factory accuracy can be improved by performing a field calibration. Also does not include any error on the sensor. ** Tolerance for these input types includes that of the external shunt resistors (0.1% tolerance) *** Reference Accuracy can be improved to +/- 0.4ºC/0.7ºF using the single point compensation calibration. Specification Pulse Input (optional) Alarm Outputs (optional) Digital Input/Output Custom Screens (optional) Event Marker (optional) Email (optional) OPC Server (optional) Analogue Outputs (Re-transmission Outputs) (optional) Health Watch/Maintenance Capability (optional) Transmitter Power (optional) Options 4 isolated inputs per board, frequency 1Hz to 25kHz, updated once per sec. Input: Low < 1V, High >4V to <50V or Volt free input: Low = short circuit, High = open circuit. Programmable alarm set points (6 per pen) can be configured to activate up to 16 outputs. Update rate: 200 ms for all alarms. Number/Type: 4 or 8 relay contacts SPDT, 3A 240VAC, 3A 24VAC/DC, 0.2A 240VDC (non-inductive, internally suppressed) 8 I/O or 16 I/O - SPNO 1A 24VDC (non-inductive, internally suppressed) Activation: Fully programmable internal alarm levels. Assignable to any relay output. 8 I/O or 16 I/O: all channels may be selected freely as either digital inputs or outputs. The Digital I/O card also has 4 channels that can be set as pulse inputs (channels 1 to 4). The operating frequency for pulse inputs on the Digital I/O card is 1kHz max. 4 relay outputs: all four channels are relay outputs only. 8 relays/ 2 DI card: two outputs can be configured for use as digital inputs: A digital input is provided by a volt free contact between the normally open (NO), and the common (C), terminals of an output relay. If the 2 Digital inputs are used only 6 relay outputs are available. Closed <500 ohms, Open >300 kohms. Provides the capability in the recorder to accept custom screen designs from the Screen Designer. User defined process events are recorded and can be set to cause particular recorder actions. Events can consist of recording start/stop, digital inputs, alarms, totalising actions, timers, barcode, etc. Once an event has been caused it can produce a definable set of effects on the recorder which can include, mark on chart, relay outputs, recording control, acknowledge alarm, trigger an Event, set/clear Relay, Screen change, E-mail a message and Reset max/mins. Each event marker can be recorded for analysis using the TrendManager Software Suite. Setup email accounts to send the following: When an Alarm is triggered or an Email can be sent as a part of an Event occurring, such as: Alarms - In/Out/Ack, Totaliser Start, Stop or Reset, Digital Inputs On, Off or State change, TC Burnout on a specific Analogue Input channel, Scheduled Events Once, Interval, Specific days, Month End. OPC 3.0 DA & AE compliant. Totalisers and up to 96 pens can be transmitted via OPC server, max poll rate 1/s. 2 or 4 re-transmission outputs available; a pen drives each output. Analog inputs, totalised values or any mathematical result can be re-transmitted. Update Rate: 250 msec all channels Accuracy: ±0.1% 0-500Ω load, +/-0.25% 500Ω 1KΩ load Type: 0 to 20 / 4 to 20 ma Maximum Load Resistance: 1000 Ohms Resolution: 0.002% Isolation: 300VAC The recorder keeps track of important life actions for improved diagnostics and preventative maintenance notification. Including Powered On, Last powered On, Time On since power up, Total On time, Total Off time, Longest Off time, Lithium cell life, Backlight life left at 100% brightness, Compact Flash insertions, Hi/Lo CJC value (Hi & Lo temps), Analogue In last factory/user cal, Relay operations. 200mA @ 24VDC ± 3VDC. www.honeywell.com/imc 11

Specification Agency Approval (optional) Extended Security System (ESS) (optional) Totaliser/Sterilisation* (optional) Batch (optional) Print Support (optional) Math Algorithms (optional) Vutronik Recorder Connection (optional) Miscellaneous CSA (Optional) CSA22.2-No.1010.1-2004 Certificate Number L211230. UL (Optional) ANSI/UL61010-1- 2004 File # 201698. FM Class 1 Division 2 (optional) Provides full support for 21 CFR Part 11. Includes features for entry of unique User ID s and associated passwords, timeout on inactivity (1 to 10 min.), password expiration (1 to 365 days), up to 50 users, password re-entry lock out for incorrect entry of password more than 3 times, no re-use of passwords (programmable 4 to 12 times), traceability by user name One totaliser per pen. Totaliser value must be assigned to a pen for display and storage. Multiple totalisations (Maths option) are possible with the use of extra pens (option). Reset may be manual or programmed (Event option). Totalisation values are ten digits plus exponent. Each pen can be totalised according to the Fo or Po sterilisation* function at 250 F (121.11 C). The Standard Reference Temperature and Thermal Resistance (Z Value) are fully adjustable values of X, Y, W and V. Start temp, Reference temp and Z factor are all user defined, allowing support for many different types of sterilisation applications. The Batch function allows the user to segment portions of data for further analysis. Batch controls include Start, Stop, Pause, for viewing, Resume and Abort. Network printing from status, message and replay screens. Pluse screen capture facility of process screens instantly using a basic USB standard PCL printer. All analog input channels have a math expression text block. This is a fully user programmable 100 character free form math expression for each pen. Math calculations are available on all pens, one per input plus 16 extra pens for the QX recorder. Scripting maths includes conditions and multi-line scripting in pen maths expressions. Allow functions, permanent variables and constants, timers. 500 characters maximum per pen. Optional rear cover with 50-pin connector for direct connection to the recorder. TDC2000/3000 system using Vutronik Trend Recorder, 24VDC instrument power only. Optional customer ID Tagging (3 lines of up to 22 characters each line). *Specification table for Sterilisation: The definition of Fo/Po is the sterilisation/pasteurisation time in minutes required to destroy a stated number of organisms with a known z at temperature T. For example, "F18/250" represents the time in minutes required to destroy a stated number of organisms at a temperature of 250 F (121.11 C) with a z = 18 degrees F. F values are used to compare the sterilizing values of different processes, however, F values cannot be compared unless the z values are the same. When temperature is not specified (for example, F = 8.6) it is understood that the temperature is 250 F (121.11 C); the subscript O (as in the term Fo = 7.4) is used to indicate that the z = 18 degrees F and the temperature is 250 F (121.11 C). Specification Environmental and Operating Conditions Parameter Reference Rated Extreme Transport & Storage Ambient Temperature 67 F to 77 F 19 C to 25 C 32 F to 122 F 0 C to 50 C 32 F to 122 F 0 C to 50 C Relative Humidity (%RH) 50 to 65* 10 to 90* 5 to 90* 5 to 95* Vibration Frequency (Hz) Acceleration (g) Mechanical Shock Acceleration (g) Duration (ms) Mounting Position from Vertical Tilted Forward Tilted Backward Tilted to Side (+/-) Power Requirements Mains Voltage (Vrms) Low Voltage AC (Vrms) DC Voltages Frequency (Hz) Power Consumption Warm Up Seismic Qualification 0 0 0 0 5 5 5 220 to 240 24 +/- 2 24 +/- 2 49.8 to 50.2 0 to 70 0.1 1 30 40 65 65 100 to 250 20 to 30 20 to 55 47 to 63 AC: <40W (max), DC: <40W (max). Typical 20W 30 minutes minimum Options 0 to 100 0.2 14 F to 140 F 10 C to 60 C 0 to 100 0.5 * The maximum rating only applies up to 104 F (40 C). For higher temperatures, the RH spec is de-rated to maintain constant moisture content. 5 30 40 65 65 90 to 264 20 to 30 20 to 55 47 to 63 20 30 Any Any Any N/A N/A N/A N/A Complies with IEEE 323-1974 and/or 1983 and IEEE 344-1975 and/or 1987 (optional) 12 www.honeywell.com/imc

Model Selection Guide TVMIQX - - _ - - _ - _ - - _ Factory Use KEY NUMBER Minitrend QX Recorder TABLE V - FIRMWARE CREDITS / OPTIONS TABLE I - ANALOGUE INPUTS/OUTPUTS Slot A None Four Analogue Inputs Six Analogue Inputs Eight Analogue Inputs Four Pulse Inputs 0 _ 4 _ 6 _ 8 _ P _ None Extended System Security None Ten Credit Twenty Credits Thirty Credits Fifty Credits Seventy Credits 0 S _ 0 1 2 3 5 7 _ Slot B None _ 0 Four Analogue Inputs _ 4 Six Analogue Inputs _ 6 Eight Analogue Inputs _ 8 Four Additional Pulse Inputs _ P Two Analogue Outputs _ A Four Analogue Outputs _ B TABLE II - DIGITAL INPUTS/OUTPUTS None 0 Two Credits 2 Five Credits 5 Eight Credits 8 TABLE Vl - OPTIONS Standard Panel Mounting Standard Panel Mounting with Rear Cover Vutronik Replacement Cover 0 _ R _ V _ Slot G None (one discrete output supplied std) 0 4 Relay Alarm Outputs 1 8 Relay Alarm / 2 Digital Inputs (6 fixed 2 (Outputs / 2 Configurable DI or DO) 8 Digital Inputs / Outputs 3 (24 VDC rated relay) 16 Digital Inputs / Outputs 4 (24 VDC rated relay) TABLE III - POWER 100-250VAC with IEC Power Plug 1 _ 100-250VAC with US Power Cord 2 _ 100-250VAC with IEC Power Plug/TX Power 3 _ 100-250VAC with US Power Cord/TX Power 4 _ 24/48VDC Instrument Power 5 _ Input Frequency Filter Value - 50Hz _ 1 Input Frequency Filter Value - 60Hz _ 2 TABLE IV - INTERNAL MEMORY EXPANSION None - (70MB standard) 0 Memory Expansion 180MB 1 Memory Expansion 400MB 2 Memory Expansion 890MB 3 Memory Expansion 1850MB 4 All product information on TrendViewer CD _ 0 English manual & language prompts with TV _ U French manual & language prompts with TV _ F German manual & language prompts with TV _ G No Tagging Linen Tag Stainless Steel Tag 0 _ L _ S _ CE Mark / NEMA 3 / IP54 _ 0 CE Mark / NEMA 4X / IP66 _ 1 CE Mark, UL Listed & CSA / NEMA 3/IP54 _ 2 CE Mark, UL Listed & CSA / NEMA 4X/IP66 _ 3 CE Mark, FM CL1 DIV2 _ 5 CE Mark, UL & CSA/FM CL1 DIV2/NEMA 4X/IP66 _ 7 No Certificate Certificate of Compliance (F3391) Custom Calibration Test Report (F3399) Certificate of Conformance & Calib. Test report 0 _ B _ C _ E _ TrendViewer _ 0 Trend Manager Pro _ P Trend Server Pro _ S Trend Server Pro with OPC capability (single) _ T Screen Designer with TrendViewer _ E Screen Designer with TrendManager Pro (single) _ F Screen Designer with TrendServer Pro (single) _ G www.honeywell.com/imc 13

Up to 16 Analogue Inputs ma (external shunt) ohms Volts mv Thermocouple RTD Data Storage media: Compact Flash - up to 4Gb USB ports for keyboard, mouse and storage Up to 192 soft alarms - 6 per pen Up to 32 Totalisers (1 per pen) Up to 4 Analogue Outputs Up to 4 Pulse Inputs Up to 8 Relay Alarm Outputs Up to 16 Digital Inputs / 24V Outputs Key: Standard Option Communications: TCP/IP, FTP, RS485 Modbus (slave) 10/100 Ethernet, Email and Web USB ports for keyboard and mouse OPC Server Fast Scanning Mode (8 Inputs) 24V Power Supply 24V Transmitter Power Supply Common Relay Output Connections Slot A Slot B Slot G Analogue Output - Slot B only 1 2 3 4 5 6 7 8 9 10 11 12 - NU Loop + Loop + Loop - NU Loop - Loop NU + Loop + - Loop Loop NU CJC Connector position 24V TX Power Supply 2-way connector Analogue Input - Slots A & B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 CJC - + * - + * - + * - + * - + * - + * - + * - + * 4 and 8 Relay Alarm - Slot G 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO (Last 2 channels can be Digital Inputs on 8 Alarm Relay card) 8 and 16 Digital Input/Output - Slot G 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Pulse Input - Slots A & B (Connector position on right hand side) 13 14 15 16 17 18 19 20 21 22 23 24 NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C NO C 24V Transmitter Power Supply This is already fitted to the power supply card within the recorder. Connection is made via a 2-way connector at rear of unit - + NU - + NU - + NU - + NU Key: NO = Normally Open, C = Common, NC = Normally Closed, NU = Not Used 14 www.honeywell.com/imc

Earth screw (ground) Wire seal 20 to 55VDC/ 20 to 30VAC Input 24/48V Instrument power (option) Analogue Input / Analogue Output / or Pulse Input Slot A Slot B AC supply 100-250VAC Common Relay Output (SPNC) 24V TX Power Supply Output Alarm or Digital I/O Slot G USB Host Ethernet RS485 100-250VAC Rear Panel AC power is connected via the standard configuration IEC chassis plug on the rear panel Installation Two mounting brackets are supplied as standard 138.00 (5.43 ) +1-0 >6.00 (0.237 ) Panel Cut-out >7.00 (0.28 ) Panel Cut-out 138.00 (5.43 ) +1-0 Panel Cut-out Minitrend QX Recorder panel cut-out www.honeywell.com/imc 15

Sales and Service For application assistance, current specifications, pricing, or name of the nearest Authorized Distributor, contact one of the offices below. ASIA PACIFIC Control Products Asia Pacific Headquarters Phone: +(65) 6355-2828 Fax: +(65) 6445-3033 Australia Honeywell Limited Phone: +(61) 7-3846 1255 FAX: +(61) 7-3840 6481 Toll Free 1300-36-39-36 Toll Free Fax: 1300-36-04-70 China PRC - Beijing Honeywell China Inc. Phone: +(86-10) 8458-3280 Fax: +(86-10) 8458-4650 China PRC - Shanghai Honeywell China Inc. Phone: (86-21) 5257-4568 Fax: (86-21) 6237-2826 China - Hong Kong S.A.R. Honeywell Ltd. Phone: +(852) 2953-6412 Fax: +(852) 2953-6767 China PRC - Chengdu Honeywell China Inc. Phone: +(86-28) 8678-6348 Fax: +(86-28) 8678-7061 China PRC - Guangzhou Honeywell China Inc. Phone: +(86-20) 3879-1169 Fax: +(86-20) 3879-1269 China PRC - Xi an Honeywell China Ltd - Xi an. Phone: +(86-29) 8833-7490 Fax: +(86-29) 8833-7489 China PRC - Shenzhen- Honeywell China Inc. Phone: +(86) 755-2518-1226 Fax: +(86) 755-2518-1221 Indonesia Honeywell Indonesia Pte Ltd. Phone: +(62) 21-535-8833 FAX: +(62) 21-5367 1008 IndiaTATA Honeywell Ltd. Phone:+(91) 5603-9400 Fax: +(91) 5603-9600 Japan Honeywell Inc. Phone: +(81) 3 6730 7150 Fax: +(81) 3 6730 7228 South Korea Honeywell Korea Co Ltd Phone: +(822) 799 6315 Fax: +(822) 792 9015 Malaysia Honeywell Engineering Sdn Bhd Phone: +(60-3) 7950-4776 Fax: +(60-3) 7958-8922 New Zealand Honeywell Limited Phone: +(64-9) 623-5052 Fax: +(64-9) 623-5060 Toll Free (0800) 202-088 Philippines Honeywell Systems (Philippines) Inc. Phone: +(63-2) 633-2830-31/ 636 1661-62 Fax: +(63-2) 638-4013 Singapore Honeywell South East Asia Phone: +(65) 6580 3278 Fax: +(65) 6445-3033 Thailand Honeywell Systems (Thailand) Ltd. Phone: +(662) 693-3099 FAX: +(662) 693-3089 Taiwan R.O.C. Honeywell Taiwan Ltd. Phone: +(886-2) 2245-1000 FAX: +(886-2) 2245-3241 EUROPE Austria Honeywell Austria GmbH Phone: +43 (316)400123 FAX: +43 (316)40017 Belgium Honeywell SA/NV Phone: +32 (0) 2 728 24 07 FAX: +32 (0) 2 728 22 45 Bulgaria Honeywell EOOD Phone: +(359) 2 40 20 900 FAX: +(359) 2 40 20 990 Czech Republic Honeywell spol. s.r.o. Phone: +420 242 442 232 FAX: +420 242 442 131 Denmark Honeywell A/S Phone: +(45) 39 55 55 55 FAX: +(45) 39 55 55 58 Finland Honeywell OY Phone: +358 (0) 20752 2753 FAX: +358 (0) 20752 2751 France Honeywell SA Phone: +33 (0)1 60198075 FAX: +33 (0)1 60198201 Germany Honeywell AG Phone: +49 (69)8064336 FAX: +49 (69)806497336 Hungary Honeywell Kft. Phone: +36-1-451 4300 FAX: +36-1-451 4343 Italy Honeywell S.p.A. Phone: +39 02 92146 307/ 395 FAX: +39 0292146377 The Netherlands Honeywell B.V. Phone: +31 (0) 20 5656200 FAX: +31 (0) 20 5656210 Norway Honeywell A/S Phone: (45) 39 55 55 55 Poland Honeywell Sp. zo.o Phone: +48-22-6060900 FAX: +48-22-6060901 Portugal Honeywell Portugal Lda Phone: +351 21 424 5000 FAX: +351 21 424 50 99 Romania Honeywell Bucharest Phone: +40 (0) 21 2316437 FAX: +40 (0) 21 2316439 Russian Federation (RF), ZAO "Honeywell" Phone: +7 (095) 796 98 00 FAX: +7 (495) 797 99 64 Slovak Republic Honeywell s.r.o. Phone: +421-2-58247 410 FAX: +421-2-58247 415 Spain Honeywell S.A. Phone: +34 (0)91313 61 00 FAX: +34 (0)91313 61 30 Sweden Honeywell AB Phone: +(46) 8 775 55 00 FAX: +(46) 8 775 56 00 Switzerland Honeywell AG Phone: +41 18552448 FAX: +(41) 1 855 24 45 Turkey Honeywell Turkey A.S. Phone: +90 216 575 6600 FAX: +90 216 575 6637 Ukraine Honeywell Tel: +380-44-201 44 74 Fax: +380-44-201-44-75 United Kingdom Honeywell Control Systems Ltd. Phone: +44 (0)1344 655251 FAX: +44 (0) 1344 655554 MIDDLE EAST Abu Dhabi U A E Middle East Headquarters Honeywell Middle East Ltd. Phone: +971 2 4041246 FAX: +971 2 4432536 Sultanate of Oman Honeywell & Co Oman LLC Phone: +968 24701153/ Ext.33 FAX +968 787351 Saudia Arabia Honeywell Turki Arabia Limited Phone: +966-3-341-0140 Fax: +966-3-341-0216 Kuwait Honeywell Kuwait KSC Phone: +965 2421327 AFRICA Mediterranean & African Distributors Honeywell SpA Phone: +39 (02) 250 10 604 FAX: +39 (02) 250 10 659 South Africa (Republic of) Honeywell Southern Africa Honeywell S.A. Pty. Ltd. Phone: +27 11 6958000 FAX +27 118051504 NORTH AMERICA Canada Honeywell LTD Phone: 1-800-737-3360 FAX: 1-800-565-4130 USA Honeywell Process Solutions, Phone: 1-800-343-0228 FAX: 1-717-771-8251 Email:sc-cp-appssales@honeywell.com LATIN AMERICA Argentina Honeywell S.A.I.C. Phone: +(54-11) 4383-3637 FAX: +(54-11) 4325-6470 Brazil Honeywell do Brasil & Cia Phone: +(55-11) 7266-1900 FAX: +(55-11) 7266-1905 Chile Honeywell Chile, S.A. Phone: +(56-2) 233-0688 FAX: +(56-2) 231-6679 Mexico Honeywell S.A. de C.V. Phone: +(52) 55 5259-1966 FAX: +(52) 55 5570-2985 Puerto Rico Honeywell Inc. Phone: +(809) 792-7075 FAX: +(809) 792-0053 Trinidad Honeywell Inc. Phone: +(868) 624-3964 FAX: +(868) 624-3969 Venezuela Honeywell CA Phone: +(58-2) 238-0211 FAX: +(58-2) 238-3391 Trademarks Minitrend QX is a registered trademark of Honeywell International Inc. Honeywell Process Solutions Honeywell 2500 W.Union Hills Drive 43-TV-03-10 Phoenix, Arizona 85027 October 2006 www.honeywell.com/imc/pi 2006 Honeywell International Inc.