Evaluation copy. Case File 9. A Killer Cup of Coffee? GlobalTech manager dies

Similar documents
GlobalTech manager dies

The Determination of an Equilibrium Constant

Determining the Free Chlorine Content of Swimming Pool Water. HOCl H + + OCl. Evaluation copy

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Phosphates (ortho- and total)

The Determination of an Equilibrium Constant

To determine the mass of iron in one adult dose of either a ferrous sulfate or. ferrous gluconate iron supplement using a colorimetric technique.

Neutralization Reactions. Evaluation copy

Evaluation copy. Titration of a Diprotic Acid: Identifying an Unknown. Computer

Evaluation copy. Enzyme Action: Testing Catalase Activity (Method 1 O 2 Gas Sensor) Computer 2

Case File 10. Dropped at the Scene: Blood spatter analysis

Household Acids and Bases

Beer's Law: Colorimetry of Copper(II) Solutions

Experiment 2 Kinetics II Concentration-Time Relationships and Activation Energy

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40

Endothermic and Exothermic Reactions. Evaluation copy. Mg(s) + 2 HCl(aq) H 2 (g) + MgCl 2 (aq)

Lab #11: Determination of a Chemical Equilibrium Constant

Evaluation copy. Energy Content of Foods. computer OBJECTIVES MATERIALS

Pressure -Temperature Relationship in Gases. Evaluation copy. Figure ml Erlenmeyer flask. Vernier computer interface

Osmosis. Evaluation copy

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

Enzyme Action: Testing Catalase Activity 50 Points

ph units constitute a scale which allows scientists to determine the acid or base content of a substance or solution. The ph 0

Colorimetric Determination of Iron in Vitamin Tablets

Appendix C. Vernier Tutorial

15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1

18 Conductometric Titration

Reaction Stoichiometry and the Formation of a Metal Ion Complex

CHEM 161: Beer s Law and Analysis of a Sports Drink

INTRODUCTION TO SPECTROMETRY

Enzyme Action: Testing Catalase Activity

Find the Relationship: An Exercise in Graphing Analysis

Chem 1B Saddleback College Dr. White 1. Experiment 8 Titration Curve for a Monoprotic Acid

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

To see how this data can be used, follow the titration of hydrofluoric acid against sodium hydroxide below. HF (aq) + NaOH (aq) H2O (l) + NaF (aq)

Upon completion of this lab, the student will be able to:

2 Spectrophotometry and the Analysis of Riboflavin

Water Hardness. Evaluation copy

EFFECT OF SALT ON CELL MEMBRANES

Household Acids and Bases

Maximum value. resistance. 1. Connect the Current Probe to Channel 1 and the Differential Voltage Probe to Channel 2 of the interface.

Using the Spectrophotometer

Chem 131A: Absorbance of Riboflavin

STANDARDIZATION OF A SODIUM HYDROXIDE SOLUTION EXPERIMENT 14

Solubility Product Constants

COLORIMETER. Description 0358BT. Figure 1. The Colorimeter

Colorimetric Determination of Iron in Vitamin Tablets

Enzyme Action: Testing Catalase Activity

Enzyme Action: Testing Catalase Activity

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

EXPERIMENT 7 Reaction Stoichiometry and Percent Yield

DETERMINATION OF PHOSPHORIC ACID CONTENT IN SOFT DRINKS

THE ACTIVITY OF LACTASE

Lab 5: Quantitative Analysis- Phosphates in Water By: A Generous Student. LBS 171L Section 9 TA: Dana October 27, 2005

EXPERIMENT 7 Electrochemical Cells: A Discovery Exercise 1. Introduction. Discussion

Enzyme Pre-Lab. Using the Enzyme worksheet and Enzyme lab handout answer the Pre-Lab questions the pre-lab must be complete before beginning the lab.

Acid Base Titrations

Reaction of Blue Food Dye with Bleach

Determination of the Mass Percentage of Copper in a Penny. Introduction

Chemistry 111 Laboratory Experiment 7: Determination of Reaction Stoichiometry and Chemical Equilibrium

Experiment 6 Coffee-cup Calorimetry

A Beer s Law Experiment

EFFECT OF ALCOHOL ON CELL MEMBRANES

6 H2O + 6 CO 2 (g) + energy

Table of Content. Enzymes and Their Functions Teacher Version 1

Vapor Pressure of Liquids

Coordination Compounds with Copper (II) Prelab (Week 2)

Mixing Warm and Cold Water

GENERAL SCIENCE LABORATORY 1110L Lab Experiment 6: Ohm s Law

Activity Sheets Enzymes and Their Functions

Understanding Analytical Chemistry (Weighing, Mixing, Measuring and Evaluating)

Acid Dissociation Constants and the Titration of a Weak Acid

DETERMINING THE MASS OF A COPPER ATOM

TITRATION CURVES, INDICATORS, AND ACID DISSOCIATION CONSTANTS

Chloride and Salinity

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

ENZYME ACTION: TESTING CATALASE ACTIVITY

Net ionic equation: 2I (aq) + 2H (aq) + H O (aq) I (s) + 2H O(l)

Heart Rate and Exercise

Properties of Acids and Bases

Measuring Protein Concentration through Absorption Spectrophotometry

10/5/06 Lab 3. Protein Determination. Lab 3. PROTEIN DETERMINATION

Lab 2. Spectrophotometric Measurement of Glucose

Determination of Citric Acid in Powdered Drink Mixes

Monitoring EKG. Evaluation copy

Experiment 8 - Double Displacement Reactions

ENZYME KINETICS ENZYME-SUBSTRATE PRODUCTS

Measuring Manganese Concentration Using Spectrophotometry

Energy Content of Fuels

III. Chemical Kinetics

To determine the equivalence points of two titrations from plots of ph versus ml of titrant added.

Recovery of Elemental Copper from Copper (II) Nitrate

Effect of Coughing on Heart Rate. Evaluation copy

The Determination of Acid Content in Vinegar

Lab 25. Acid-Base Titration and Neutralization Reactions: What Is the Concentration of Acetic Acid in Each Sample of Vinegar?

ph: Measurement and Uses

Chemistry 2351: Inorganic Chemistry I Laboratory Manual

DNA Electrophoresis Lesson Plan

Transcription:

Case File 9 Killer Cup of Coffee: Using colorimetry to determine concentration of a poison Determine the concentration of cyanide in the solution. A Killer Cup of Coffee? SOUTH PAINTER, Tuesday: It was a normal Monday morning at GlobalTech Industries until the mail boy discovered project manager Patrick Marchand dead in his cubicle, head on his desk. Mr. Marchand had died while writing an email, in a room full of people hard at work. An early examination of the crime scene yielded no clues. Mr. Marchand was known to have a serious heart condition, and many signs pointed to cardiac arrest as the cause of his death. However, as police canvassed the office space, the distinct odor of bitter almonds was detected, and a vial containing a small amount of an unknown chemical was found discarded in a communal trash can. Based on the bitter almond odor, police have tentatively identified the substance as cyanide. The existence of this possible LAB NOTES Technician: Beverly Chin GlobalTech manager dies poison has lead police to suspect foul play in Mr. Marchand s death. The police have no leads. continued on p. D2 This vial, wrapped in a piece of tissue, was discovered in the bottom of a communal trash can near the GlobalTech office bathroom. It once contained an unspecified amount of cyanide. Evaluation copy -received vial containing 20 ml cyanide solution concentration unknown -reacted cyanide (CN ) solution with potassium polysulfide (K 2 S x ) to produce potassium thiocyanate (KSCN) -reacted KSCN solution with iron(iii)chloride (FeCl 3 ) to produce iron(iii)thiocyanate ion (FeSCN 2+ ) -determination of amount of FeSCN 2+ in reacted solution will allow estimation of concentration of CN in original solution -included in package: FeSCN 2+ solution of unknown concentration

Killer Cup of Coffee Case 9 OBJECTIVES Use Beer s law to determine the concentration of simulated iron(iii) thiocyanate (FeSCN 2+ ) in an unknown solution. Use colorimetry to determine the concentration of a colored species in a solution. Use a linear relationship to model the data (Beer s law). Learn the importance of carefully prepared standards. MATERIALS computer goggles Vernier computer interface 5 ml of simulated FeSCN 2+ solution of unknown Logger Pro concentration in the suspicious vial Vernier Colorimeter two 10 ml pipettes or graduated cylinders 7 cuvettes 50 ml of 0.15 M stock simulated FeSCN 2+ colored wax pencil solution distilled water 2 droppers waste beaker 6 test tubes two 5 ml beakers test tube rack stirring rod lint-free tissues PROCEDURE CAUTION: Obtain and wear goggles during this experiment. Be careful not to ingest any solution or spill any on your skin. Inform your teacher immediately in the event of an accident. Part I Preparing the Solutions 1. Obtain and label the following with a wax pencil: a. Pour 50 ml of stock simulated 0.15 M FeSCN 2+ solution into a 50 ml beaker. Label the beaker Simulated 0.15 M FeSCN 2+. b. Pour 30 ml of distilled water into a 50 ml beaker. Label the beaker H 2 O. 2. Prepare the unknown and standard solutions. a. Label five clean, dry test tubes with numbers 1 through 5. b. The following table shows how much water and stock simulated FeSCN 2+ solution to add to each test tube. Use a pipette or a dropper and graduated cylinder to measure the correct amount of simulated FeSCN 2+ solution into each test tube. Note: Use a separate pipette or graduated cylinder and dropper for the water and the simulated FeSCN 2+. c. Carefully stir the contents of each test tube with a clean stirring rod. (Carefully clean the stirring rod with distilled water and dry it with a tissue before using it in the next test tube.) d. Label a sixth test tube with a U for unknown. Use a pipette or a dropper and graduated cylinder to measure 5 ml of simulated FeSCN 2+ solution of unknown concentration into the test tube. Evaluation copy Forensics with Vernier 9-1

Case 9 Test Tube FeSCN 2+ Solution (ml) Distilled Water (ml) Final Concentration of FeSCN 2+ (mol/l) 1 10 0 0.15 2 8 2 0.12 3 6 4 0.09 4 4 6 0.06 5 2 8 0.03 3. Prepare the blank, the five standard solutions, and the unknown for colorimetry. a. For each standard solution, rinse an empty cuvette twice with about 1 ml of the sample. b. Fill each cuvette 3/4 full with the sample, and seal it with a lid. c. Label the lid with the sample number. d. Wipe the outside of each cuvette with a tissue. e. Repeat Steps 3a 3d for the unknown sample. Label the lid with a U. f. Repeat Steps 3a 3d using distilled water for the blank. Label the lid with a B. Remember the following: All cuvettes should be clean and dry on the outside. Handle cuvettes only by the top edge or the ribbed sides. All solutions should be free of bubbles. Part II Collecting Data 4. In your Evidence Record, enter the volume of the suspicious vial. 5. Connect the Colorimeter to the computer interface. Prepare the computer for data collection by opening the file 09 Killer Coffee from the Forensics with Vernier folder of Logger Pro. 6. Calibrate the Colorimeter. a. Open the Colorimeter lid. Place the blank cuvette, containing distilled water, in the cuvette slot of the Colorimeter. Make sure that one of the transparent faces of the cuvette is pointing toward the white reference mark. Close the lid of the Colorimeter. b. Press the < or > button on the Colorimeter to select a wavelength of 470 nm (Blue). c. Press the CAL button until the red LED begins to flash. Then release the CAL button. When the LED stops flashing, the calibration is complete. 9-2 Forensics with Vernier

Killer Cup of Coffee 7. You are now ready to collect absorbance-concentration data at 470 nm for the solutions. a. Click to begin data collection. b. Place cuvette 1 in the Colorimeter, with the cuvette clean, dry, and with a transparent face pointing toward the reference mark. c. After closing the lid, wait for the absorbance value displayed on the monitor to stabilize, then click. d. Enter the concentration of the solution (from the table in Step 2) and press the ENTER key. The data pair you just collected should now be plotted on the graph. e. Remove the cuvette from the Colorimeter. f. Repeat Steps 7b e for the remaining standards in cuvettes 2 through 5. 8. Click when you have collected data for all the samples. 9. In your Evidence Record, write down the absorbance values displayed in the Data Table (round to the nearest 0.001). Part III: Analyzing the Data 10. Place the cuvette with the unknown solution in the Colorimeter. Monitor the absorbance value displayed on the screen. When this value has stabilized, round it to the nearest 0.001 and write it in your Evidence Record. 11. To determine the concentration of FeSCN 2+ in the unknown solution, fit a straight line to the graph of absorbance vs. concentration. Use the interpolation calculator in Logger Pro to estimate the concentration of FeSCN 2+ in the unknown solution. a. Click the Linear Fit button,. A best-fit linear regression line will be shown for your five data points. This line should pass near or through the data points and the origin of the graph. The equation for a straight line is y = mx + b, where y is absorbance, x is concentration, m is the slope, and b is the y-intercept. b. A floating box on the graph will display the values of m and b that give the best fitting line to your data points. The correlation coefficient indicates how well the data points match the linear fit. A value of 1.00 indicates a perfect fit. Record the values of m, b, and the correlation in the Evidence Record. The linear relationship between absorbance and concentration is known as Beer s law. c. With the linear regression curve still displayed on your graph, choose Interpolation Calculator from the Analyze menu. Click in the Interpolation Calculator Options box that appears. The calculated concentration of the unknown solution will appear on the graph in a floating box. The corresponding concentration value is the concentration of the unknown FeSCN 2+ solution, in mol/l. Write this value in the Evidence Record. Forensics with Vernier 9-3

Case 9 EVIDENCE RECORD Volume of the suspicious vial Solution Number Concentration of Simulated FeSCN2+ in Solution (mol/l) Absorbance 1 0.15 2 0.12 3 0.09 4 0.06 5 0.03 U Unknown Concentration of FeSCN 2+ in the unknown solution y mx + b m b correlation CASE ANALYSIS 1. Write the equation for the line in the form y = mx + b, using the values for m and b that you recorded in the Evidence Record. For example, if m = 3 and b = 6, then the equation for the line is y = 3x + 6. 2. Use the equation to calculate the concentration of FeSCN 2+ in the unknown solution. How does the value you calculate compare with the value you read from the graph? 3. The volume of the cyanide solution that was found at the scene was 20 ml. Based on the calculated concentration of FeSCN 2+ in the unknown solution, determine the concentration of potassium cyanide, KCN, in the original poison. Show all your work. Give your answer in milligrams of KCN per milliliter of solution. Hint: One mole of KCN will produce one mole of FeSCN 2+. Assume that all of the KCN in the poisoned solution reacted to form FeSCN 2+. Assume that the 20 ml of original solution was not diluted during the reaction to form FeSCN 2+ and that the sample you received was also undiluted. The molecular weight of FeSCN 2+ is 114 g/mol. The molecular weight of KCN is 65 g/mol. 4. For most people, swallowing 300 mg of KCN is fatal. Based on the concentration of KCN in the poison that you calculated in Question 3, determine the approximate volume of poison that the victim would have to have swallowed for it to have killed him. Show all your work. 9-4 Forensics with Vernier

Killer Cup of Coffee 5. Is it likely that the poison was the direct cause of death? Explain your answer. Hint: Remember that the vial was mostly empty and may, at one time, have held more than 20 ml. 6. Suppose you found out that the concentration of FeSCN 2+ in the unknown was actually very different from the value you calculated in Question 2 and the value you read off the graph. What factors could have caused that to happen? Forensics with Vernier 9-5

Vernier Lab Safety Instructions Disclaimer THIS IS AN EVALUATION COPY OF THE VERNIER STUDENT LAB. This copy does not include: Safety information Essential instructor background information Directions for preparing solutions Important tips for successfully doing these labs The complete Forensics with Vernier lab manual includes 14 labs and essential teacher information. The full lab book is available for purchase at: http://www.vernier.com/cmat/fwv.html Vernier Software & Technology 13979 S.W. Millikan Way Beaverton, OR 97005-2886 Toll Free (888) 837-6437 (503) 277-2299 FAX (503) 277-2440 info@vernier.com www.vernier.com