Use of Micropipettes



Similar documents
DNA Electrophoresis Lesson Plan

Using the Spectrophotometer

Archived. Gloves should be changed frequently during the analysis.

Calibration of Volumetric Glassware

THE ACTIVITY OF LACTASE

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY. STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 079 MOD: 1st Issue Page: 1 of 7

Determination of the Mass Percentage of Copper in a Penny. Introduction

Bacterial Transformation with Green Fluorescent Protein. Table of Contents Fall 2012

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40

COMMON LABORATORY APPARATUS

Calibration of Glassware

Lab 5: DNA Fingerprinting

Solubility Product Constants

LAB 11 PLASMID DNA MINIPREP

CHEM 161: Beer s Law and Analysis of a Sports Drink

ph Measurements of Common Substances

2C: One in a Million. Part 1: Making solutions. Name: Section: Date: Materials

Calibration of Volumetric Glassware

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

EFFECT OF SALT ON CELL MEMBRANES

The Determination of an Equilibrium Constant

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

Reaction Stoichiometry and the Formation of a Metal Ion Complex

Lab 2. Spectrophotometric Measurement of Glucose

Factors Affecting Enzyme Activity

Fixed and Adjustable Spacing Electronic Pipettes

Phosphorus Analyzer Procedure Last updated: A. Introduction

For safety information, see the ABI PRISM 310 Genetic Analyzer User s Manual (PN or ).

EFFECT OF ALCOHOL ON CELL MEMBRANES

Coating and Extraction of Honeycomb Denuders

Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1

HARVESTING AND CRYOPRESERVATION OF HUMAN EMBRYONIC STEM CELLS (hescs)

Biology 29 Cell Structure and Function Spring, 2009 Springer LABORATORY 2:CHLOROPLASTS AND PHOTOREDUCTION

Transformation of the bacterium E. coli. using a gene for Green Fluorescent Protein

DNA Analyst Training Laboratory Training Manual Protocol 2.02 Clean Technique

Activity Sheets Enzymes and Their Functions

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #:

ENZYME KINETICS ENZYME-SUBSTRATE PRODUCTS

Quantifying Bacterial Concentration using a Calibrated Growth Curve

Pre-Lab Notebook Content: Your notebook should include the title, date, purpose, procedure; data tables.

PRACTICAL 3: DIGESTIVE ENZYMES, SPECIFICITY AND ph

APPENDIX N BULK MILK TANKER SCREENING TEST FORM

Appendix C. Vernier Tutorial

Agarose Gel Electrophoresis with Food Color- Teacher Guide

Instructions for Use. Components of the GENOTROPIN PEN 12

Olympic B3 Summer Science Camp 2015 Weller, Smith, Putnam L3

A simple guide to using the HumaPen Luxura HD. If you need help with your Pen, call the. HumaPen Luxura HD Help Line:

Transformation Kit BACTERIAL TRANSFORMATION: GREEN FLUORESCENT PROTEIN. Partnership for Biotechnology and Genomics Education

NIH Clinical Center Patient Education Materials Giving a subcutaneous injection

Aseptic Technique. A GMP/GTP Training Module

RESTRICTION ENZYME ANALYSIS OF DNA

Laboratory 5: Properties of Enzymes

Policies. Prep Room Policies

Promoting safer use of injectable medicines

A Beer s Law Experiment

Calibration and Use of a Strain-Gage-Instrumented Beam: Density Determination and Weight-Flow-Rate Measurement

ClikSTAR - Important facts about your new insulin delivery device.

UltraClean Forensic DNA Isolation Kit (Single Prep Format)

Color, True and Apparent

Single Channel Electronic Pipettes MPA. Series

10/5/06 Lab 3. Protein Determination. Lab 3. PROTEIN DETERMINATION

Physical and Chemical Changes

Color, True and Apparent

Quick guide: using CTE security straws for cryopreservation of pronuclear stages, embryos and sperm

Ti-Pure TITANIUM DIOXIDE. DETERMINATION OF BROOKFIELD VISCOSITY, TiO 2 SLURRY METHOD: T WP

UltraClean PCR Clean-Up Kit

PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200

Upon completion of this lab, the student will be able to:

Enzymes: Amylase Activity in Starch-degrading Soil Isolates

HiPer Ion Exchange Chromatography Teaching Kit

KwikPen Insulin delivery device

6 H2O + 6 CO 2 (g) + energy

The volume of a penny will be calculated from its mass and density.

Acid Base Titrations

STANDARDIZATION OF A SODIUM HYDROXIDE SOLUTION EXPERIMENT 14

Procedure for RNA isolation from human muscle or fat

Assessment of Accuracy and Precision

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

CHM 130LL: ph, Buffers, and Indicators

Vitamin C Content of Fruit Juice

Catalytic Activity of Enzymes

Fuel Cell Characterization Lab

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

Your Best Choice For Laboratory Consumables

(1) Hydrochloric acid reacts with sodium hypochlorite to form hypochlorous acid: NaOCl(aq) + HCl(aq) HOCl(aq) + NaCl(aq) hypochlorous acid

Dissolved Oxygen Sensors

HYFLAM D3: Report of Scenarios 08/02/2012

AIRFREE TECHNIQUE AND SENSITIVE REAGENTS S ECTI O N 1: GLASS W ARE A ND E Q UIP M ENT. A. Using a manifold

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA

FUEL CELL EXPERIMENTATION

2 Spectrophotometry and the Analysis of Riboflavin

AU680 Every Other Week or Every 3,000 Samples (ISE) Maintenance. AU680 Weekly (Analyzer and ISE) Maintenance

RAINBOW ELECTROPHORESIS 1 An Introduction to Gel Electrophoresis

Transferring a Broth Culture to Fresh Broth

Volumetric Measurement

Standard Operating Procedure

SYNTHESIS AND ANALYSIS OF A COORDINATION COMPOUND OF COPPER

Transcription:

Use of Micropipettes Prior to lab you should understand: The function of micropipettes in the laboratory Basic parts of micropipette What volumes are measured with P, P and P1 micopipettors How to read the volume indicator on a P, P and P1 How much each micropipettor costs and how they are paid for I. Objective: Learn how to use a micropipettor II. Background: Micropipettors are the standard laboratory equipment used to measure and transfer small volumes of liquids. You will use them throughout this semester and in advanced courses that you take in the future. It is essential that you master their use if you are to be successful in your experiments. A. Parts of a micropipette a. Plunger button b. Tip ejector button c. Volume adjustment dial d. Digital volume indicator e. Shaft f. Attachment point for a disposable tip c d e a b B. Three sizes of micropipettes f The micropipettors in this laboratory come in three different sizes each of which measures a different range of volumes. The three sizes are P, P and P1. These sizes are noted on the top of the plunger button. Size Micropipette P P P1 Range of volumes measured.5-µl -µl 1-1µl

C. Adjusting Volume on micropipettes The black volume adjustment dial near the top of the micropipette allows you to adjust the volume that is measured. It can be dialed to the left or right to increase or decrease the volume. The digital readout shows the volume that will be measured. As you turn the volume adjustment dial, the numbers in the digital readout will change. On each of the three sizes of micropipettes (P, P, P1) the digital readout has three numbers. These three numbers correspond to different volumes on the different size pipettes. See the figure below for instructions on interpreting digital readout. Volume adjustment dial Digital readout shows the volume you have set. Micropipettor: Reading the Volume p 1 p p 1x 1x 1x 1x 1x 1x 1x 1x.1x Volume set: µl Volume set: µl Volume set:. µl In a P1, the top number refers to 1 s of µl, the middle number refers to 1 sµl and the bottom number refers to 1 s of µl s. In a P, the top number refers to 1 s of µl, the middle number refers to 1 s µl and the bottom number refers to µ ls. In a P, the top number refers to 1 s of µl, the middle number refers to µl s and the bottom number refers to 1/1 ths of µl.

Practice In the boxes below, write how many µls the following digital readout correspond to in each of the pipetters? 7 P Digital Readout P P1 Write volume in µl Which micropipettor would be appropriate to measure 5µl? Fill in the numbers that should appear in the digital display if that pipettor were to measure 5µl. D. Pipette Tips Liquids are never drawn directly into the shaft of the pipette. Instead, disposable plastic tips are are attached to the shaft. There are two sizes of tips. The larger blue tips are used for the P1. The smaller clear tips are used for the P and P. The tips are racked in plastic boxes with covers. When you receive a box, it will be sterile. Please be careful when touching box or tips not to contaminate them. The box should be closed when not in use to prevent airborn contamination. Inserting the Tip 1. Select the correct size tips.. Open the box without touching the tips with your hands.. Insert the micropipette shaft into the tip and press down firmly. This will attach the tip to the shaft. 4. Remove the micropipettor with the tip attached. 5. Close the box without touching the tips with your hands. E. Punger Settings The plunger will stop at two different positions when it is depressed. The first of these stopping points is the point of initial resistance and is the level of depression that will result in the desired volume of solution being transferred. The second stopping point is when the plunger is depressed beyond the initial resistance until it is in contact with the body of the pipettor. At this point, the plunger cannot be depressed further. This second stopping point is only used for the complete discharging of solutions from the plastic tip.

F. Measuring and transferring a volume of liquid Before measuring and transferring liquid: Choose the appropriate size micropipettor Adjust to the correct volume Insert tip on the shaft. Measuring and transferring liquid The figure below shows the correct operation of the pipetteman. Important: note the first plunger stop is used in steps 1 through 4. The second plunger stop is only used in step 5. Depress the thumb knob to the first stop. Immerse the tip approximately mm into the sample solution (step 1). Slowly release the thumb knob to the initial position (step ). Watch as the solution is drawn up slowly into the tip. Do not release the plunger too quickly. Rapid release might draw bubbles in the solution and might splash solution on the non-sterile shaft. Withdraw the tip from the sample solution. Place the tip against the side wall of the receiving container (step ). Smoothly depress the thumb knob to the first stop (step 4), pause, then depress the knob to the second stop (step 5). Remove the tip from the receiving container, and return knob to the initial position. Do not let the knob snap back. Remove the disposable tip by firmly depressing the tip ejector knob (step 6). Add as new tip and continue.

F. Micropipette Rules Each micropipette cost $ and is paid for by your technology fee. To keep these pipettors functioning properly it is important that they be handled with care. Please follow these rules to keep from breaking the micropipetters 1. Never adjust the volume beyond the range of the micropipettor. No micropipette should be adjusted below zero µl. The P should never be adjusted above µ, the P over ul and the P1 over 1ml.. Never force the volume adjustor dial. If the knob becomes difficult to adjust it probably means that you are exceeding the limits for the pipette or the pipette is damaged. Please report the problem to the instructor or TA.. Do not drop pipetters. 4. Always use a smooth motion when using the pipetters. This will help give you accurate measurements and also prevent breakage of pipettes. There should be not snapping noises. 5. Always keep pipettes upright. Store the micropipettes on the mounted rack on your bench when not in use. Never lay a pipette on the benchtop. 6. Always choose to appropriate size pipette for the volume you are measuring. 7. Always dispose of tips in appropriate waste containing. Never leave tips in glassware. III. Materials: Each Station should have: P, P, and P1 Small and Large tips Microcentrifuge tubes Disposable Cuvettes Calibrated Spectrophotometer Bottle of blue dye Beaker of water Liquid waste beaker Container for discarded pipette tips Water rinse bottle Kimwipes Note: We will be using a spectrophotometer to measure the amount of blue dye in each sample. We will discuss the how spectrophotometers work in future laboratory exercises. In brief they measure how much light a sample absorbs. The spectrophotometer passes a beam of light through a special sample holder called a cuvette. It then measures how much of this light is absorbed by the sample. The absorbance of light is displayed on the spectrophotometer. The more dye in a sample, the greater the absorbance.

IV. Procedure: A. Preparing a dilution of Blue dye 1. Choose appropriate micropipettor to measure 75µl.. Transfer 75 µl of blue dye to empty microfuge tube.. Use a P1 to transfer 1ml of water to microfuge tube. 4. Mix tube vigorously B. Spectrophotometer reading 1. Pour the blue dye you diluted in the microfuge tube into a cuvette. Insert cuvette into spectrophotometer. Observe absorbance reading from digital display on spectrophotometer 4. Record measurement in data sheet below C. Comparison to instructor value 1. Obtain correct absorbance value for 75 µl dilution from instructor. Divide your value by the instructor s value to determine whether you were within 1% of the instructor s value. If you are outside the 1% range you are making an error in your pipetting. D. Independent trials 1. Repeat 75µl dilution two more times as outline in boxes A-C.. Rinse and tap dry cuvette between each measurement.. Use a new microfuge tube for each dilution 4. Record values in data collection sheet. 5. Compare with instructors value for same dilution Repeating with other dilutions 1. Repeat procedures as outlined in boxes A-D except as outlined below.. Prepare new dilutions using the following quantities of blue dye a. µl b. 15µl c. 5µl. Record your data on the table collection sheet attached. 4. Conduct three trials for each dilution

V. Short Report Name: Due at end of class session Data Collection Sheet Dilutions Trials Student Absorbance Instructor Absorbance Ratio (S/I) 75µl 1 µl 1 15µl 1 5µl 1