Vertical Display and Storage B1350-2. SKOPE Gen2: Three Door Chiller



Similar documents
Portable Air Conditioner

PORTABLE AIR CONDITIONER

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Dehumidifier Users manual. For Models: DH45S DH65S

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

LUCCI AIRFUSION QUEST II CEILING FAN

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Processor Cage Fans, Front and Rear Replacement Instructions

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Meaco 30L and Meaco 40L dehumidifier instruction manual

Operations Manual Blast Chiller

Important Safeguards

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Wine Cooler with Thermo-Electric Cooling & Heating Technology

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

Single Day Alarm Clock with. Bluetooth and USB Play-through

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

- 2 - IMPORTANT SAFETY REMINDERS

V94 BULK TAPE DEGAUSSER

5800 Temperature Sensor Cable Assembly

WINDOW ROOM AIR CONDITIONER

Operating instructions in the back. PD1020L

Air Conditioner. Portable BTU/h 2.9kW INSTRUCTION MANUAL CWAC11 CPIN Important! Please read these instructions carefully.

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

General Purpose Laboratory Freezer with Alarms

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Front Panel Board Cable Replacement Instructions

SANDWICH/SALAD PREP & MEGA TOP UNDERCOUNTER REFRIGERATOR UNDERCOUNTER FREEZER

MAINTENANCE & TROUBLESHOOTING

USER S MANUAL HSC-24A

MFU200 Integrated Under Counter Larder Fridge

User Guide. rev. 08/11. RENTAL SALES SERVICE LOGISTICS Toll free number:

Split Type Room Air Conditioner. KSWM units

INSTALLATION & USER INSTRUCTIONS

STAINLESS STEEL WINE / BEVERAGE COOLER INSTRUCTION MANUAL HVBC31ST

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

MCR1900 Media Converter 19-Slot Chassis

HEAT RECOVERY VENTILATORS MODELS 90H-V ECM HRV, 90H-V+, 60H-V+ AND ENERGY RECOVERY VENTILATOR MODEL 90H-V ECM ERV

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

How To Use A Power Supply Unit (Upu)

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Cooktop Low-Profile Ventilation Hoods

Operating Instructions

Manual for Fire Suppression & Methane Detection System

PREVENTATIVE MAINTENANCE

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

42U/45U 28" Wide Rack Installation & Service Guide

Installation Instructions

OPL BASIC. Dosing System for Professional Laundry machines. Contents

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY

BUILT-IN WINE & BEVERAGE COOLER WITH DUAL TEMPERATURE ZONES INSTRUCTION MANUAL. Model No.: MCWBC77DZC

IMPORTANT SAFETY RULES TO FOLLOW

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Taurus Series YORK Window Air Conditioners

UV100A Ultraviolet Air Treatment System

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Wireless Home Security Alarm System AM 500

Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF

Operating and Installation Instructions

Installation Instructions and Owner's Manual. Double-Hung Windows Room Air Conditioner. This manual must be left with the owner of the equipment.

Troubleshooting Guide for Dispenser Model #900172

DIGITAL WARMING CABINETS

Installation Instructions

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

GenStore Archive Cabinet

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

REFRIGERATOR INSTRUCTION MANUAL. Model No.: MCBR170W/B/S

Record Cleaning Machine

, User s Manual

HEAT PUMP PROGRAMMABLE THERMOSTAT

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Air Conditioning System

PR 50 Frymaster Universal Holding Cabinet (UHC)

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

Operating instructions Cordless K impact wrench

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

EKOS Cart. Instructions for Use

Transcription:

Vertical Display and Storage User Manual MAN1227 Rev. 3.0 March 2008 edition

CONTACT ADDRESSES Designed and Manufactured by New Zealand SKOPE INDUSTRIES LIMITED PO Box 1091, Christchurch New Zealand Freephone: 0800 947 5673 Fax: (03) 983 3896 E-mail: enquiry@skope.co.nz Website: www.skope.co.nz Australia SKOPE AUSTRALIA PTY LTD A.C.N. 000 384 270 PO Box 7543, Baulkham Hills B.C. NSW 2153, Australia Freephone: 1800 121 535 Fax: 1800 121 533 E-mail: enquiry@skope.com.au Website: www.skope.com.au i

User Manual MAN1227 Rev. 3.0 March 2008 edition. Copyright 2004 SKOPE Industries Limited. All rights reserved. SKOPE and CYCLONE are registered trademarks of SKOPE Industries Limited. SKOPE Industries Limited reserve the right to alter specifications without notice. ii

TABLE OF CONTENTS INSTALLATION Safety Information......................................6 Fitting the Kick Panel...................................7 Fitting the Illuminated Sign...............................8 Positioning of Machine..................................9 Mains Flex....................................9 Ventilation.....................................9 Siting the Cabinet...............................9 Isolating Switch.................................9 OPERATION Operation of Machine..................................10 Refrigeration Unit..............................10 Electronic Controller............................10 Cabinet Lighting...............................10 Fitting the Shelves....................................11 Loading Product...............................11 Cleaning............................................12 Condenser Coil................................12 Servicing............................................13 ELECTRONIC CONTROLLER Controller Display.....................................14 Temperature Setpoint.................................16 Troubleshooting......................................17 Controller Alarms.....................................18 iii

INSTALLATION Safety Information When using any electrical appliance, safety precautions should always be observed. Read these instructions carefully and retain for future reference. When used by, or near, young children or infirm persons, close supervision is necessary. Young children should be supervised to ensure that they do not play with the appliance. Do NOT use this appliance for other than its intended use. Do NOT cover the grilles or block the entry or exhaust of airflow by placing objects up against the refrigeration unit. Do NOT probe any opening. Only use this appliance with voltage specified on the rating label. Ensure adequate ventilation of the SKOPE refrigeration unit. Be careful not to touch moving parts and hot surfaces. Regulations require that all electrical work be carried out by authorised persons. For your own safety, and that of others, ensure this is done. If the supply cord becomes damaged, it must be replaced by a SKOPE authorised service agent, or similarly qualified person, in order to avoid a hazard. If the refrigeration unit is required to be installed or removed from the cabinet, ensure all necessary safety precautions are observed. This chiller is not designed to be stable in motion. Exercise caution when moving or transporting this chiller. Warning: Do NOT overload the power supply. See the rating label inside the cabinet for power supply and current draw. Caution: Disconnect the cabinet from the mains power supply before attempting any cleaning or maintenance. 6

INSTALLATION Fitting the Kick Panel For transit purposes the kick panel is packed inside the cabinet, with the electronic controller temporarily attached to the front of the refrigeration unit. Before fitting the kick panel to the cabinet the controller must be attached to the inside of the kick panel. To fit the kick panel: 1. Loosen the two keyhole screws holding the controller box onto the refrigeration unit. Lift the controller box off the keyhole screws and carefully pull out from the unit compartment. 2. Locate the controller box onto the back of the kick panel, so the two screws in the top of the controller box slot into the keyholes in the kick panel. Tighten the keyhole fixing screws through the top set of slots (see Figure 1 below). 3. Open the cabinet doors wide open. This is to allow the fitting of the kick panel. Sit the kick panel over the two corner bottom locating brackets and push on to the two top keyhole fixing screws. Tighten both the screws. Ensure the controller cables are well clear of any sharp objects on the refrigeration unit. Fixing Screws Kick Panel Controller Figure 1: Attaching the Electronic Controller Figure 2: Electronic Controller Relocated 7

INSTALLATION Fitting the Illuminated Sign For transit purposes the illuminated sign is packed inside the cabinet. To fit the illuminated sign unit to the roof of the cabinet: 1. Loosen the four retaining screws on the roof of the cabinet and fit both the sign side panels over the screws. Slide the panels forward, flush with the front of the cabinet, and tighten screws. 2. Clip the sign rear panel into the retaining slots on the rear of the sign sides (see Figure 4 below). 3. Fit the sign unit by engaging the clips into retaining slots on the front of each side panel and pull sign unit firmly down. Ensure the two screws in the back of the sign unit fit into slots in the cabinet top angle bracket and then tighten all the screws. 4. Turn the sign retaining clips on top of each side panel, to hold the sign unit firmly in position (see Figure 3 below). 5. Connect the sign ENSTO 3-pole plug into the power supply socket on the roof of the cabinet. Sign Retaining Clip Sign Side Panel Sign Back Panel Figure 3: Sign Retaining Clip Figure 4: Sign Rear Panel 8

INSTALLATION Positioning of Machine Mains Flex For transit purposes the mains flex and plug are clipped to the roof of the cabinet. For convenience, the flex should be retrieved before the machine is positioned when walls and partitions may make access difficult. Ventilation When positioning the cabinet, ensure adequate ventilation is provided around the refrigeration unit at floor level. The castors must remain fitted as the refrigeration unit draws air from underneath the cabinet. Avoid blocking any air vents or placing objects up against the front of the cabinet. The maximum recommended operating ambient temperature is 40 C. Siting the cabinet When siting the cabinet, avoid direct sunlight and warm draughts etc. Adequate allowance should be made for door opening. The doors have internal torsion bars which are pre-tensioned at the factory. The cabinet must be positioned on a level surface for the doors to shut and seal correctly and to prevent the condensate tray from overflowing. Isolating Switch This cabinet has a mains isolating switch and IEC (appliance) socket, located in the refrigeration unit compartment. This switch and socket can be used to isolate all cabinet and unit electrics, without unplugging the cabinet from the wall. When installing the cabinet, ensure the mains isolating switch is turned on. 9

OPERATION Operation of Machine Plug in the machine and check operation of the refrigeration unit, electronic controller and cabinet lighting. Refrigeration Unit The compressor, and evaporator and condenser fans should all operate initially. This may be verified by listening for compressor switch on, and checking air movement out of the slots in the front kick panel. The internal cabinet air will continue to circulate at all times, as the evaporator fan operates continuously. The compressor should switch off when the cabinet internal temperature reaches approximately +2 C, and switch on again at approximately +4 C. A fan reversing device, reverses the condenser fan motor for a period of time during the compressor off-cycle. This rotation change is to assist with self-cleaning of the condenser coil. Otherwise, the condenser fan operates continuously in a clockwise (LE) direction. Electronic Controller The electronic controller, located in the front kick panel, will either display the internal cabinet temperature or the controller set point. The compressor ON icon will indicate when the compressor is operating (see pages 14-15 for controller display). Cabinet Lighting The lights which illuminate the top sign and cabinet interior will initially come on, when the machine is turned on, and will stay on permanently. The lights will require a period of time to stabilise following initial start up. 10

OPERATION Fitting the Shelves The chiller is supplied with either four or five cabinet shelves which may be positioned at different heights to suit various products. Each shelf is held in place with eight shelf clips which engage in each of the shelf support strips. The support strips are marked with a + for easy location of shelf clips. To fit the cabinet shelves: 1. Unpack the shelves and shelf clips from inside the cabinet. 2. Establish the desired position for the shelves and securely engage a shelf clip in each of the shelf support strips (see Figure 5 below). 3. Sit the shelves onto the shelf support clips. Loading Product For even cooling and efficient operation allow air space around packages etc. Do not allow products to overhang the front of the shelf as this could prevent the door from shutting or cause glass breakage. Leave an airspace of at least 75mm (3") above packages etc. on the top shelf. Shelf Support Strip Shelf Shelf Clip + Mark Figure 5: Shelf Clip 11

OPERATION Cleaning When necessary, wipe the interior and exterior of the cabinet with a damp cloth. Ensure the cabinet is disconnected from the mains power supply before cleaning. Periodic cleaning of the condenser coil is also recommended. Condenser coil The condenser coil MUST be kept clean for efficient and reliable operation. Clean the condenser coil with a brush and vacuum cleaner regularly. The condenser coil is located behind a side baffle, on the right hand side of the refrigeration unit (see Figure 6 on p13). To access the condenser coil: 1. Disconnect the cabinet from the mains power supply. 2. Remove the cabinet kick panel, by loosening the two screws at the top of the kick panel. Access to these screws can be made easier by opening the cabinet doors. Raise the kick panel vertically to clear the keyholes off the screw heads, then tilt the panel forward and lift off the bottom fixing brackets. 3. Remove the cabinet wiring junction box by loosening both the end keyhole fixing screws. 4. Remove the two screws holding the side baffle to the condenser coil and carefully pull the baffle out from the unit. 5. The condenser coil can now be accessed for cleaning. Clean the condenser coil with a brush and vacuum cleaner. 6. Refit the side baffle and cabinet wiring junction box. 7. Refit the cabinet kick panel, and reconnect to the power supply. Caution: The cabinet MUST be disconnected from the mains power supply before cleaning the condenser coil. 12

OPERATION Servicing Servicing should be carried out by an authorised service agent. Detailed service and spares information is available in the SKOPE Operating and Service Manual (Part No. MAN1228). Kick Panel Keyhole Fixing Screw Cabinet Door (open) Condenser Coil Cabinet Kick Panel Cabinet Wiring Junction Box Keyhole Fixing Screw Figure 6: Condenser Coil 13

ELECTRONIC CONTROLLER Controller Display Figure 7: Controller Display Keypad ITEM KEY FUNCTION 1 Prg / mute: To initiate programme sets, press for 5 seconds. Mutes the audible alarm (buzzer) and deactivates the alarm relay. 2 UP / aux: To scroll settings UP (in programme mode). 3 Set: If pressed for more than 2 seconds displays and / or enables changing the temperature setpoint (see page 16). 4 DOWN / def: To scroll settings DOWN (in programme mode). Table 1: Keypad Functions 14

ELECTRONIC CONTROLLER Icons ITEM ICON FUNCTION 5 6 FAN: n.a. COMPRESSOR: ON when the compressor and condenser fan starts. Flashes when activation of the compressor is temporarily delayed. 7 DEFROST: ON when the defrost is activated. Flashes when the activation of the defrost is temporarily delayed due to procedures in progress. 8 AUX: n.a. 9 ALARM: Flashes in the event of alarms. 10 CLOCK: n.a. 11 LIGHT: n.a. 12 SERVICE: Flashes in the event of malfunctions. 13 DISPLAY: Shows the cabinet temperature. 14 HACCP: n.a. 15 CONTINUOUS CYCLE: n.a. Table 2: Icon Functions 15

ELECTRONIC CONTROLLER Temperature Setpoint The chiller temperature setpoint is factory set at 2.0 C. If necessary the standard setting can be adjusted between 1 C and 3.5 C (see Table 3 below). SKOPE do not recommend that the setpoint be changed unless it is absolutely necessary, and then only by small increments at a time. To View and Adjust the Temperature Setpoint: 1. To view the setpoint: press and hold the SET key for 2 seconds, until the setpoint value flashes. 2. To adjust the setpoint: press either the UP or DOWN keys to display the required setpoint value. 3. Press the SET key again to memorise the new setpoint value. If this is not done within 60 seconds, changes will be lost and you will need to repeat the above procedure. Table 3: Viewing and Adjusting the Temperature Setpoint 16

ELECTRONIC CONTROLLER Troubleshooting Complaint Possible Cause Repair 1. Cabinet not operating and no controller display: 2. Cabinet lights not operating: 3. Power consumption is higher than expected: 4. Product is too warm and spoiling: 5. Warm cabinet temperatures and/ or compressor operating for long periods (more than 1 hour): Loss of power supply. Blown cabinet fuse. Failed fluorescent tube. Controller alarm. Unit operating too hot. Cabinet door is opened excessively. Restricted cabinet airflow. Check mains power supply. Requires technical repair by a SKOPE Authorised Service Agent. Check fluorescent tubes. Determine cause and eliminate (see pages 18-19). Clean condenser. Ensure the chiller is installed with good ventilation around the refrigeration unit. Keep door/s open for minimum time. Ensure product is not blocking airflow slots and there is air space around all the product. Temperature setpoint is too warm. Adjust setpoint (see page 16). Blocked condenser. Clean condenser (see pages 12-13). Poor refrigeration unit ventilation. Ensure the cabinet is installed with good ventilation around the refrigeration unit. Table 4: Troubleshooting 17

ELECTRONIC CONTROLLER Controller Alarms CODE DISPLAY ICON ALARM DESCRIPTION Product HIGH temperature alarm Product LOW temperature alarm Refrigeration system high temperature pre-warning Refrigeration system high temperature shutdown Ambient probe fault Evaporator probe fault Condenser probe fault None Defrost over-time limit Real-time clock fault Controller E prom error Controller E prom error None Start defrost request None End defrost request Table 5: Controller Alarms 18

ELECTRONIC CONTROLLER INITIAL ACTION FINAL ACTION 1. Check the cabinet product loading to ensure ventilation slots are not blocked and that product does not overhang the shelves. 2. Ensure the cabinet is installed with good refrigeration unit ventilation. 3. Check and clean the condenser coil (see pages 12-13). 4. Unplug cabinet from the power supply for 1 minute, then reconnect to power supply. 1. Clean the condenser coil (see pages 12-13). 2. Check refrigeration ventilation. Ensure clear airpath at the top and front of the cabinet (to extract hot air). A minimum of 200mm clear space is required in front of the refrigeration unit. 3. Ensure the cabinet is installed in a suitable environment. 4. Unplug cabinet from the power supply for 1 minute, then reconnect to power supply. If alarm persists, contact SKOPE. Unplug cabinet from the power supply for 1 minute, then reconnect to power supply. None None 19