Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.



Similar documents
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Elson 10/15L Unvented Water Heater

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH7/2.2, AH10/2.2, AH15/2.2

Elson 2.5 litre Boiling Water Dispenser

Installation and User Instructions Aquaheat Unvented Water Heaters Models: SS H 50/80 & 100

Megalife Vented Cistern Fed Water Heater Installation manual

Aquatap (Boil and Chill / Boil and Ambient) Installation and user manual

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

SF15K SF05KSS, SF10KSS

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

ELECTRIC INSTANTANEOUS WATER HEATER

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

REDRING POWERSTREAM-ECO UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

OPERATING INSTRUCTIONS

INFRARED QUARTZ WALL HEATER

Unvented water heater

INSTALLATION & USER INSTRUCTIONS

Shower Handbook (Also covers 650 chrome variant)

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Electronically Controlled Instantaneous Water Heaters Models: DEX & DBX

Unvented water heater

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Operators manual Basic water heater

Triac Printed Circuit Board Replacement

IMPORTANT: PLEASE READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE COMMENCING INSTALLATION. PACK CONTENTS

Meaco 30L and Meaco 40L dehumidifier instruction manual

Hot Water Urns. all models. Helpline. v3.0

Isotemp Basic, Slim/B & Slim Square

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Chill 4 Hole Bath Shower Mixer

User's Instructions. Alpha HE CB25/33 and HE SY25

Assembly and instructions

Protect your pipes. Keep the water cycle running smoothly and be prepared in winter. Heat, insulate and protect your home.

Cooling system components, removing and installing

Zip Hydroboil Plus Cuts energy consumption dramatically

OR S HANDBOOK Kenco S i n g l e s B r e w e r OPERA

INSTALLATION INSTRUCTIONS & OWNERS GUIDE

ferroli Boiler Replacement Optimax HE- Modena HE

Visage. Digital. Exposed with adjustable height head. Visage Digital exposed installation instuctions page 1

Protect your pipes. Keep the water cycle running smoothly and be prepared in winter. Heat, insulate and protect your home.

Overheating limit control

Protect your pipes. Be prepared this winter heat, insulate and protect your home

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

Liquorice Kitchen Sink Tap

ELECTRIC CENTRAL HEATING FLOW BOILER

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) (ROI) White series

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Drayton Digistat +2RF/+3RF

Operating Instructions. Room temperature controller

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

HeatSource HS1800 Heater

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Installation, Operating and Servicing Instructions. Electric Auto-Fill Push Button Water Boilers EB3F/PB and EB3F/PBM

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

V94 BULK TAPE DEGAUSSER

New Zip Hydroboil Plus Cuts energy consumption dramatically

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

INSTALLATION INSTRUCTIONS & OWNERS GUIDE

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

Baxi Combi 80e & 105e

High kw Electric Tankless Water Heater Troubleshooting Guide

PG_IM_A.indd 1 23/06/ :22

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Aquamax Australia Pty Ltd ABN

Owners Guide and Installation Instructions.

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Please also see 10 golden rules for correct Saniflo installation on

SERVICE MANUAL Order No.WH0911S001V0

Operating instructions

Electric Water Heater

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Apricot Kitchen Sink Tap

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Almond Kitchen Sink Tap

Electric Mini Tank Water heaters GL GL 4 - GL 6+

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

Almond Kitchen Sink Tap

SERVICE SERVICE MANUAL FOR ALDE ELECTRICAL HEATER

SHOT BLAST CABINET MODEL NO: CSB20B

SERVICE MANUAL REFRIGERATION


Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Atlanta CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. IF UNSURE CONSULT A QUALIFIED ELECTRICIAN

Apricot Kitchen Sink Tap

Transcription:

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1. Please read and understand these instructions before starting work. Please leave this leaflet with the user following installation PACK CONTENTS Heater, Fixing screws and plugs, Installation and User Instructions, and Guarantee card. WARNING This water heater must only be installed by competent persons 36005806 Issue 08 1

1.0 INTRODUCTION Thankyou for purchasing a Santon Aquarius water heater. The Aquarius water heater is manufactured in the UK to the highest standards and has been designed to meet all the latest relevant safety specifications. This Aquarius water heater must be installed and maintained by a competent person only. Please read and understand these instructions prior to installing your Aquarius water heater. Particular attention should be paid to section three headed INSTALLATION. Following installation the operation of the heater should be explained to the user and these instructions left with them for future reference. This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Children must be supervised to ensure they do not play with the appliance. 2.0 TECHNICAL SPECIFICATION Electrical rating... 1.17/1.2kW@230/240V~ 2.75/3.0kW@230/240V~ Capacities... 7 & 10 litres Weight... 7 litre - 9.3kg, 10 litre - 12.5kg Rated Pressure... 0Mpa (0bar) Minimum recommended supply pressure... Mains fed or cistern fed (3m head required) Temperature range... 10 to 70 C 2

Name Aquarius Model AU7/3 AU7/1 A10U/3 A10U/1 Volume Litres 7 7 10 10 V40 9 9 11 11 Load Profile XXS XXS XXS XXS Energy Efficiency Class C C C C Energy Efficiency % 31.4 31.4 31.9 31.9 Annual electricity consumption kwh 587 587 578 578 Daily fuel consumption kwh 2.850 2.850 2.790 2.790 Thermostat setting 60 C Specific precautions that shall be taken when the water heater is assembled, installed or maintained and disposed of at end of life See Section 2 to 5 Table: Technical parameters in accordance with European Commision regulations 814/2013 and 812/2013 FIGURE 01: DIMENSIONS DIMENSION X Y 7 LITRE 356 349 10 LITRE 442 435 240 240 100 57 2 KEYHOLE FIXING SLOTS FOR UNDERSINK FIXING 120 3rd FIXING HOLE X 120 Y 3.0 INSTALLATION 3.1 LOCATION 3.1.1 Inlet must always be on the right. 3.1.2 The outlet of this water heater acts as a vent and must not be blocked or restricted in any way. 3.1.3 Only Santon open outlet accessories must be used with this water heater. A full range is available, please consult your distributor or Santon for further information. 3.1.4 The installation must be carried out in accordance with the relevant requirements of the appropriate Building Regulations, either: 3

4 The Building Regulations The Building Regulations (Scotland) or Building Regulations (Northern Ireland) The Water Fittings Regulations or water Byelaws in Scotland 3.1.5 Select a suitable site but check that: a) There is enough clearance above the heater to allow for pipe connections and removal of the element plate. b) There are no hidden services where the wall is to be drilled. 3.1.6 Mark the position of the fixing holes (as shown in Figure 01). 3.1.7 Drill and plug the hole positions. 3.1.8 Screw in the lower two screws leaving heads 3mm from the wall. 3.1.9 Hang the heater on the two screws. 3.1.10 Screw in top screw to secure heater. 3.2 PLUMBING 3.2.1 This water heater is designed for cistern-fed application in conjunction with a separate cistern and vent pipe (see Figure 02). 3.2.2 Alternatively the heater can be connected directly to the water mains provided that a Santon vented tap is used (see Figure 03). 3.2.3 Both inlet and outlet pipes are clearly labelled. The pipes are 15mm tube and are suitable for compression fittings. 3.2.4 It is recommended that a WRAS listed isolating valve (not supplied) be fitted in the water supply pipe to the heater to allow for servicing. 3.3 ELECTRICAL 3.3.1 Warning: this appliance must be earthed. It is suitable for a.c. supply only. Electrical installation must be carried out by a competent electrician and be in accordance with the latest I.E.E. regulations. 3.3.2 Nominal cross-section of supply cable must be at least 1.5mm 2. A double pole isolating switch with a contact separation of at least 3mm in each pole must be incorporated in the supply. 3.3.3 Remove the terminal cover using a large flat bladed screwdriver to relieve the snaps located towards the front at either side of the cover. Gripping the cover at the front, pull upwards. 3.3.4 Strip the outer sheath and insulation on the cable to the required lengths, push the cable through the grommet provided, this will be held in the cable grip when the connections are made (see Figure 04). 3.3.5 Pass the cable underneath the cable grip and through the top moulding. 3.3.6 Make the connections to the terminal block as follows: Live (brown or red wire) to terminal marked L Neutral (blue or black wire) to terminal marked N Earth (green or green/yellow wire) to terminal marked. 3.3.7 Secure the cable in the cable grip by tightening the two screws. 3.3.8 Set the adjustable thermostat by rotating the control to the required temperature. It is recommended that it is set to lowest acceptable temperature to meet user requirements. This will minimise the risk of scalding and reduce the level of scaling in hard water areas. 3.3.9 Replace terminal cover by locating the hinge at the rear. Slide the snaps into place. Apply pressure to the front of the cover, pushing back and down until it snaps securely in place.

FIGURE 02: CISTERN FED APPLICATION FIGURE 03: OPEN OUTLET APPLICATION (USING 'VENTED TAP') CISTERN SINK VENTED HOTTAP MAINS HOT COLD STOP COCK HOT COLD STOP COCK MAINS FIGURE 04: INTERNAL LAYOUT OUTLET CABLE CLAMP THERMOSTAT CONTROL INLET CAPILLARY STAT TERMINAL BLOCK ELEMENT THERMAL CUT-OUT EARTH POST FIGURE 05: WIRING DIAGRAM. EARTH THERMOSTAT BULB THERMOSTAT GREEN&YELLOW NEUTRAL (BLACK) BLUE/BLACK LIVE (RED) BROWN/RED TERMINAL BLOCK THERMAL FUSE TO ELEMENT 5

4.0 COMMISSIONING 4.1 DO NOT SWITCH ON HEATER UNTIL IT IS FILLED WITH WATER Fill with water by opening tap and leaving open until a full bore of water flows from the outlet. 4.2 Switch on water heater at double pole isolating switch. The heater will heat water to the temperature set on the thermostat. 4.3 Check water is heating correctly. 7 litre 1.2kW - after 10 mins water temperature will increase by 20 C 7 litre 3kW - after 10 mins water temperature will increase by 60 C 10 litre 1.2kW - after 10 mins water temperature will increase by 15 C 10 litre 3kW - after 10 mins water temperature will increase by 40 C 4.4 Pass instruction leaflet to user and draw their attention to the following two statements: DO NOT USE HEATER IF THE WATER IS THOUGHT TO BE FROZEN Switch off immediately at the isolating switch if the water does not flow freely. Any damage resulting from freezing will not be covered by the guarantee. DURING HEATING THE OUTLET WILL DRIP This is due to the expansion of water inside the heater and is normal for heaters of this type. It does not indicate that the valve is faulty and over tightening of the valve can result in damage. 5.0 FAULT FINDING Your Aquarius water heater should give you trouble free operation, however, should a problem occur the table below should enable most faults to be identified with ease. Fault finding should only be carried out by a competent person and any replacement part should be authorised Santon spare parts. SYMPTOM PROBABLE CAUSE ACTION No hot water 1. Check power Check and replace as necessary. Water too hot /cold 2. Faulty cut out 3. Faulty thermostat 4. Faulty element 1. Thermostat set to wrong temperature Adjust thermostat. 2. Faulty thermostat Switch off, check and replace. No water flow 1. Frozen Switch off electrical power and allow to thaw at room temperature. Do not switch on again until full water flow restored and full checks made for leaks and electrical safety. 2. No mains supply Check mains. Continuous water flow Faulty valve/tap Check and replace. 6

6.0 SPARE PARTS In the unlikely event of your Water Heater developing a fault, the following spare parts are available: Element plate assembly 7 litre 1.2kW 95 606 902 Element plate assembly 7 litre 3kW 95 606 903 Element plate assembly 10 litre 1.2kW 95 606 904 Element plate assembly 10 litre 3kW 95 606 905 Element plate assembly gasket 95 611 021 Capillary thermostat 95 612 051 Over temperature cut-out 95 612 050 Top cover moulding 95 614 272 Terminal cover 95 614 273 Adaptor long 95 607 954 Adaptor o-ring 95 607 955 Fixing fork 95 607 956 7.0 GUARANTEE This product is guaranteed against faulty materials and manufacture for a period of 2 years from the date of purchase provided that: 1. The unit has been installed in accordance with the Installation and User Instructions and all relevant Codes of Practice and Regulations in force at the time of Installation, and that all necessary controls and safety valves have been fitted correctly. 2. Any valves and controls are of the Santon recommended type and specification. 3. The unit has not been modified or tampered with in any way, and has been regularly maintained as detailed in the Installation and User Instructions. 4. The unit has been used only for heating potable water. The unit is not guaranteed against damage by frost, and the inner container with integral immersion heater is not guaranteed against excessive scale build-up. This Guarantee in no way affects the statutory rights of the consumer. Santon s policy is one of continuous product development and, as such, we reserve the right to change specifications without notice. 8.0 ENVIRONMENTAL INFORMATION This product is manufactured from many recyclable materials. At the end of its useful life it should be disposed of at a Local Authority Recycling Centre in order to realise the full environmental benefits. Insulation is by means of CFC-free polyurethane foam. This product does not contain any substances harmful to health; it does not contain any asbestos. 7

9.0 SPARES STOCKISTS Electric Water Heating Co. 2 Horsecroft Place, Pinnacles, Harlow, Essex CM19 5BT E-mail: sales@ewh.co.uk SPD Units 9 & 10 Hexagon Business Centre Springfield Road, Hayes Middlesex UB4 0TY Tel : 020 8606 3567 Newey & Eyre Unit 3-5 Wassage Way Hampton Lovett Ind. Estate, Droitwich, Worcestershire WR9 0NX Tel : 01905 791500 Fax: 01905 791501 UK Spares Ltd. Unit 1155 Aztec West, Almondsbury, Bristol BS32 4TF Tel: 01454 620500 Alternatively, contact your local supplying merchant, wholesale branch or use our online stockist finder at www.interpartspares.co.uk Hurricane Way, Norwich Norfolk, NR6 6EA. www.santon.co.uk Service Tel: 0344 871 1530 Service E-mail: customer.support@heatraesadia.com 8