TECHNICAL NOTES. Celerra Physical to Virtual IP Address Migration Utility Technical Notes P/N 300-012-104 REV A03. EMC Ionix ControlCenter 6.



Similar documents
TECHNICAL NOTES. Technical Notes P/N REV 02

Table 1 on page 4 presents the revision history of this document: Revision Date Description. A01 March 30, 2012 Initial release of this document.

EMC Perspective. Application Discovery and Automatic Mapping for an On-Demand Infrastructure

All other trademarks used herein are the property of their respective owners.

EMC NetWorker. Server Disaster Recovery and Availability Best Practices Guide. Release 8.0 P/N REV 01

A Guide to. Server Virtualization. Block Storage Virtualization. File Storage Virtualization. Infrastructure Virtualization Services

VNX Unified Storage Management Lab Guide

EMC Support Matrix. Interoperability Results. P/N ECO Rev B30

Microsoft SQL Server 2008 on EMC VNXe Series

How To Use An Uniden Vnx5300 (Vx53I) With A Power Supply (Sps) And Power Supply Power Supply For A Power Unit (Sse) (Power Supply) (Sus) (Dae

Today s Choices for. Compliance. Regulatory Requirements and Content Archiving Records Management ediscovery

EMC Atmos Virtual Edition with EMC VNX Series

EMC PRODUCT W ARRANTY AND M AINTENANCE T ABLE

EMC Smarts Application Discovery Manager and Multisite Data Aggregation

EMC PowerPath Family. Product Guide. Version 5.7 P/N REV 04

NetWorker Module for Microsoft SQL Server INSTALLATION GUIDE. Release 5.0 P/N E

EMC Solutions at Microsoft: Optimizing Exchange Backup and Recovery with VSS (Volume Shadowcopy Service) Technology Integration

EMC DiskXtender File System Manager for NAS MICROSOFT WINDOWS INSTALLATION GUIDE. Release 2.0 (Beta Version) P/N E

Next-Generation Backup, Recovery, and Archive

EMC Ionix MPLS Manager

EMC HomeBase. Enhanced Server Provisioning Product Guide. Version 6.6 P/N REV A01

EXPORT COMPLIANCE PRODUCT INFORMATION

Sal Fernando Chief Technical Architect EMC Enterprise Solutions Group AP/J

Payment System Electronification The Role of Automated Networked Storage

Luka Topic Channel Manager EMC Adriatic. Banja Luka 27th May Copyright 2008 EMC Corporation. All rights reserved.

Using Windows Administrative Tools on VNX

Replicating VNXe3100/VNXe3150/VNXe3300 CIFS/NFS Shared Folders to VNX Technical Notes P/N h REV A01 Date June, 2011

Copyright 2006 EMC Corporation. Do not Copy - All Rights Reserved.

Installing Management Applications on VNX for File

EMC VSI for VMware vsphere: Storage Viewer

EMC ViPR Controller. Version 2.4. User Interface Virtual Data Center Configuration Guide REV 01 DRAFT

EMC ViPR Controller. User Interface Virtual Data Center Configuration Guide. Version REV 01

EMC ViPR Controller. Service Catalog Reference Guide. Version 2.3 XXX-XXX-XXX 01

Setting Up a Unisphere Management Station for the VNX Series P/N Revision A01 January 5, 2010

Domain Management with EMC Unisphere for VNX

Technical Notes TECHNICAL NOTES. Release number 8.2 Service Pack REV 01. January, 2015

EMC Celerra Network Server

Technical Notes P/N Rev 01

TECHNICAL NOTES. Technical Notes P/N REV 01

Virtualized Exchange 2007 Archiving with EMC Xtender/DiskXtender to EMC Centera

Leverage Your EMC Storage Investment with User Provisioning for Syncplicity:

The EMC CLARiiON Navisphere Command Line Interface (CLI): History and Best Practices

EMC Data Domain Management Center

EMC and Cisco. Case Study. Building Disaster Recovery and Business Continuance Solutions. Date 4/15/2004

IMPROVING VMWARE DISASTER RECOVERY WITH EMC RECOVERPOINT Applied Technology

EMC ViPR Controller. ViPR Controller REST API Virtual Data Center Configuration Guide. Version

Using Group Policy to Manage and Enforce ACL on VNX for File P/N REV A01 February 2011

EMC Navisphere Manager ADMINISTRATOR S GUIDE P/N REV A12

AX4 5 Series Software Overview

EMC Documentum Repository Services for Microsoft SharePoint

SETTING UP ACTIVE DIRECTORY (AD) ON WINDOWS 2008 FOR EROOM

EMC NETWORKER SNAPSHOT MANAGEMENT

EMC Documentum Content Services for SAP Document Controllers

EMC ViPR Controller Add-in for Microsoft System Center Virtual Machine Manager

Copyright 2013 EMC Corporation. All Rights Reserved.

EMC NetWorker VSS Client for Microsoft Windows Server 2003 First Edition

Managing the SSL Certificate for the ESRS HTTPS Listener Service Technical Notes P/N REV A01 January 14, 2011

Increasing Recoverability of Critical Data with EMC Data Protection Advisor and Replication Analysis

EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, Symmetrix Management Console, and VMware vcenter Converter

Citrix XenServer Workload Balancing Quick Start. Published February Edition

eg Enterprise v5.2 Clariion SAN storage system eg Enterprise v5.6

DELETE DUPLICATE S IN THE EMC XTENDER ARCHIVE SYSTEM USING THE MSGIDCRACKER UTILITY

How To Configure Vnx (Vnx) On A Windows-Only Computer (Windows) With A Windows 2.5 (Windows 2.2) (Windows 3.5) (Vnet) (Win

EMC DATA PROTECTION ADVISOR

EMC SourceOne. Disaster Recovery Solution Guide. Version REV 01

IBM WEBSPHERE LOAD BALANCING SUPPORT FOR EMC DOCUMENTUM WDK/WEBTOP IN A CLUSTERED ENVIRONMENT

Release Notes P/N Rev 01

Installing and Configuring DB2 10, WebSphere Application Server v8 & Maximo Asset Management

EMC Documentum Interactive Delivery Services Accelerated: Step-by-Step Setup Guide

EMC Documentum Composer

Veritas Cluster Server Database Agent for Microsoft SQL Configuration Guide

Technical Notes. EMC NetWorker Performing Backup and Recovery of SharePoint Server by using NetWorker Module for Microsoft SQL VDI Solution

EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution

EMC Documentum Interactive Delivery Services Accelerated Overview

EMC Replication Manager for Virtualized Environments

Backup Recovery Avamar. Secrets To Acing The Exam and Successful Finding And Landing Your Next Backup Recovery Avamar Certified Job

THE VIRTUAL DATA CENTER OF THE FUTURE

EMC NetWorker Module for Microsoft Applications Release 2.3. Application Guide P/N REV A02

EMC NetWorker Module for Microsoft Exchange Server Release 5.1

SolarWinds Migrating SolarWinds NPM Technical Reference

EMC PERSPECTIVE: THE POWER OF WINDOWS SERVER 2012 AND EMC INFRASTRUCTURE FOR MICROSOFT PRIVATE CLOUD ENVIRONMENTS

16 TB of Disk Savings and 3 Oracle Applications Modules Retired in 3 Days: EMC IT s Informatica Data Retirement Proof of Concept

EMC Secure Remote Support Gateway for Windows Release 2.24

Deploying EMC Documentum WDK Applications with IBM WebSEAL as a Reverse Proxy

EMC SourceOne for Microsoft SharePoint Storage Management Version 7.1

ENABLING SINGLE SIGN-ON FOR EMC DOCUMENTUM WDK-BASED APPLICATIONS USING IBM WEBSEAL ON AIX

Use QNAP NAS for Backup

Sage HRMS 2014 Sage Employee Self Service Tech Installation Guide for Windows 2003, 2008, and October 2013

EMC NetWorker. Licensing Guide. Release 8.0 P/N REV A01

Transcription:

TECHNICAL NOTES EMC Ionix ControlCenter 6.1 Celerra Physical to Virtual IP Address Migration Utility Technical Notes P/N 300-012-104 REV A03 August 2011 These release notes contain supplemental information about EMC Ionix ControlCenter Celerra Physical to Virtual IP Address Migration Utility. Topics include: Overview... 2 Prerequisites... 2 Installing the Migration utility... 3 Setup and validate... 3 Implementing the Migration utility... 4

Overview Overview Celerra Physical IP address to Virtual IP address migration utility is an Ionix ControlCenter utility that migrates physical IP addresses to Virtual IP addresses for the discovered Celerra systems. The utility also migrates the stored assisted discovery (ADA) requests. You have to run this utility before discovering the Celerra using virtual IP. To enable the virtual IP discovery support after using this migration utility, perform the steps mentioned in EMC Ionix ControlCenter 6.1 Release Notes and EMC Ionix ControlCenter 6.1 Update Bundle 9 Read Me. Note: This is a one time activity and you do not have to provide new ADA after the script is used. Prerequisites Before running the migration utility, ensure that the following prerequisites are met: Ionix ControlCenter should be upgraded to update bundle 9. Celerra should not be discovered using virtual IP. Database should be exported. To export the database, click Start > All Programs > EMC > EMC ControlCenter >Repository Maintenance > ControlCenter Repository > Export Database. IMPORTANT If fail over happens after Celerra being discovered using active physical IP address, then the standby or the passive physical IP address will be the active physical IP address. If the Celerra is discovered again using another physical IP address, console will display two physical IP addresses in the tree view. Any one of the Physical IP should be migrated to Virtual IP. CAUTION!: DO NOT DELETE THE OTHER PHYSICAL IPs. CONTACT ENGINEERS FOR CUSTOM FIELD MIGRATION. For example: If the discovered Celerra has IP address 10.247.55.207, due to fail over this IP address changes to standby or passive. Another Celerra with physical IP address 10.247.55.206 will be active. If the Celerra is discovered again using the physical IP address 10.247.55.206, the console will display two physical IP addresses. If you have discovered Celerra using physical IP address before discovering using virtual IP address, you have to run this migration script. The migration script will convert all physical IP address to Virtual IP address in the database without any historical data loss. If you delete the physical IP addresses manually, all the historical data would be lost and migration script will not help in converting physical IP addresses to virtual IP addresses. 2 EMC Ionix ControlCenter Celerra Physical to Virtual IP Address Migration Utility Technical Notes

Installing the Migration utility Installing the Migration utility This section provides information on installing the migration utility. 1. Extract the Migrate.zip to <ECC_INSTALL_ROOT>\tools\utils\Migrate. 2. Move the CnameCoversionUtility folder from <ECC_INSTALL_ROOT>\tools\utils\Migrate to <ECC_INSTALL_ROOT>\tools\utils. 3. Verify for the following files under CnameConversionUtility folder: CnameCoversion.bat CnameCoversion.jar Log - folder containing the log files generated by Java. This folder will be created only after the migration is completed. Note: Delete any other files or folders available in this folder. 4. Verify if the upgrade folder exists under <ECC_INSTALL_ROOT>\repository\admin\Ramb_scripts directory. If not, create an upgrade folder. 5. Move the following files from <ECC_INSTALL_ROOT>\tools\utils\Migrate to <ECC_INSTALL_ROOT>\repository\admin\Ramb_scripts\ upgrade directory: DomainNameChange.dat TableColname.dat 6. Move all the other files from <ECC_INSTALL_ROOT>\tools\utils\Migrate to <ECC_INSTALL_ROOT>\repository\admin\Ramb_scripts directory. Note: After installing the Migration utility, Ionix ControlCenter Performance Manager refers two set of data provider under NAS container for the migrated celerra: Physical IP data provider: Historical data prior to migration utility installation, mapped to celerra physical IP provider. For time lines, prior to migration utility installation, Ionix ControlCenter user can use physical IP data provider to get the performance reports. Virtual IP data provider: After installing the Migration utility, Ionix ControlCenter performance manager creates Virtual IP data provider and the user can select Virtual IP data provider to query post migration performance manager reports. Setup and validate This section provides information on setting up and validating the migration utility. 1. Stop the NAS agent. 2. Stop all the Ionix ControlCenter services. 3. Create the following system variable by right-clicking My Computer and Properties > Advanced > Environment Variables and click New in System variables dialog. EMC Ionix ControlCenter Celerra Physical to Virtual IP Address Migration Utility Technical Notes 3

Implementing the Migration utility Implementing the Migration utility Variable Name: ECC_HOST_NAME Variable Value: <ECC_INSTALL_ROOT>\ecc_inf\data For example, if the path is \ECC\ecc_inf\data\ecc_inf_hostname, then set the variable ECC_HOST_NAME to ecc_inf_hostname This section provides information on implementing the migration utility. 1. Login to Ionix ControlCenter Server or Repository system. 2. Verify the following and make changes, if required: a. In the command prompt, type Set to verify if the ECC_HOST_NAME system variable is created. If this system variable is missing, repeat step 3 as mentioned in Setup and validate on page 3. b. Ionix ControlCenter services are not running, if not, stop all the Ionix ControlCenter services. c. Verify the following services are running and are set to Automatic: OracleServiceRAMBDB OracleECCREP_HOMETNSListener 3. Edit the Domainnamechange.dat file located in the <ECC_INSTALL_ROOT>\Repository\admin\Ramb_scripts\ upgrade directory. The Domainnamechange.bat file should consist of the physical and virtual IP address information. Use comma (,) to separate the physical address and virtual address. For example, Physical IP, Virtual IP, Physical Hostname, Virtual Hostname, Physical hostname, Virtual IP Physical FQDN, Virtual FQDN, Physical FQDN, Virtual IP, Use the following sample screens to edit the Domainnamechange.dat file: If Celerra is discovered using physical IP address: If Celerra is discovered using hostname: 4 EMC Ionix ControlCenter Celerra Physical to Virtual IP Address Migration Utility Technical Notes

Implementing the Migration utility or If Celerra is discovered using FQDN: or If Celerra is discovered using Physical IP, ADA shows Physical IP. Later if it is discovered through Hostname, ADA shows two entries, that is, Physical IP and Hostname: 4. Open a new command prompt and type ecc_getversion to validate the ability to connect to the repository before running the migration scripts. 5. Navigate to %ECC_INSTALL_ROOT%\Repository\admin\Ramb_scripts directory and run Migrate.bat file. The following message appears: EMC Ionix ControlCenter Celerra Physical to Virtual IP Address Migration Utility Technical Notes 5

Implementing the Migration utility Return code = 0 messages are good 6. Navigate to %ECC_INSTALL_ROOT%\Repository\admin\Ramb_scripts and run ramb_staging_disable.bat and ramb_staging_enable.bat. This script can be run only once. If an error occurs, import the last exported database. 7. Start all the Ionix ControlCenter services and NAS agent that were stopped. EMC Ionix ControlCenter 6.1 Planning and Installation Guide Volume 1 provides more information on enabling Virtual IP discovery support using the migration utility. Copyright 2011 EMC Corporation. All rights reserved. Published in the USA. Published August 2011 EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. The information in this publication is provided as is. EMC Corporation makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. EMC 2, EMC, EMC Centera, EMC ControlCenter, EMC LifeLine, EMC OnCourse, EMC Proven, EMC Snap, EMC SourceOne, EMC Storage Administrator, Acartus, Access Logix, AdvantEdge, AlphaStor, ApplicationXtender, ArchiveXtender, Atmos, Authentica, Authentic Problems, Automated Resource Manager, AutoStart, AutoSwap, AVALONidm, Avamar, Captiva, Catalog Solution, C-Clip, Celerra, Celerra Replicator, Centera, CenterStage, CentraStar, ClaimPack, ClaimsEditor, CLARiiON, ClientPak, Codebook Correlation Technology, Common Information Model, Configuration Intelligence, Connectrix, CopyCross, CopyPoint, CX, Dantz, Data Domain, DatabaseXtender, Direct Matrix Architecture, DiskXtender, DiskXtender 2000, Document Sciences, Documentum, elnput, E-Lab, EmailXaminer, EmailXtender, Enginuity, eroom, Event Explorer, FarPoint, FirstPass, FLARE, FormWare, Geosynchrony, Global File Virtualization, Graphic Visualization, Greenplum, HighRoad, HomeBase, InfoMover, Infoscape, InputAccel, InputAccel Express, Invista, Ionix, ISIS, Max Retriever, MediaStor, MirrorView, Navisphere, NetWorker, OnAlert, OpenScale, PixTools, Powerlink, PowerPath, PowerSnap, QuickScan, Rainfinity, RepliCare, RepliStor, ResourcePak, Retrospect, RSA, SafeLine, SAN Advisor, SAN Copy, SAN Manager, Smarts, SnapImage, SnapSure, SnapView, SRDF, StorageScope, SupportMate, SymmAPI, SymmEnabler, Symmetrix, Symmetrix DMX, Symmetrix VMAX, TimeFinder, UltraFlex, UltraPoint, UltraScale, Unisphere, Viewlets, Virtual Matrix, Virtual Matrix Architecture, Virtual Provisioning, VisualSAN, VisualSRM, VMAX, VNX, VNXe, Voyence, VPLEX, VSAM-Assist, WebXtender, xpression, xpresso, YottaYotta, the EMC logo, and the RSA logo, are registered trademarks or trademarks of EMC Corporation in the United States and other countries. Vblock is a trademark of EMC Corporation in the United States. All other trademarks used herein are the property of their respective owners. For the most up-to-date regulatory document for your product line, go to the technical documentation and advisories section on the EMC online support website. 6 EMC Ionix ControlCenter Celerra Physical to Virtual IP Address Migration Utility Technical Notes