ACTIVE-B12 EIA. the next level of B12 testing



Similar documents
SMF Awareness Seminar 2014

Diagnosis of HIV-1 Infection. Estelle Piwowar-Manning HPTN Central Laboratory The Johns Hopkins University

B12 & Cobalamin. Learning objectives

ELISA BIO 110 Lab 1. Immunity and Disease

Saskatchewan Drug Information Services College of Pharmacy and Nutrition, U of S T: (306) F:(306)

Human Luteinizing Hormone (LH) Custom Kit

Human Free Testosterone(F-TESTO) ELISA Kit

KMS-Specialist & Customized Biosimilar Service

Guidelines for the Investigation and Management of Vitamin B12 and Folate Deficiency

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

Hillsborough Community College - Ybor City Campus 1025C Laboratory Exercise 9: Testing Urine for the Presence of Drugs Introduction

Teriflunomide is the active metabolite of Leflunomide, a drug employed since 1994 for the treatment of rheumatoid arthritis (Baselt, 2011).

QuickTiter FeLV Core Antigen ELISA Kit (FeLV p27)

The sensitive marker for glomerular filtration rate (GFR) Estimation of GFR from Serum Cystatin C:

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

HuCAL Custom Monoclonal Antibodies

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA

> IGF-1 (human) Table of Contents. Catalog # Well Enzyme Immunoassay Kit For use with human serum and plasma

TRIIODOTHYRONINE (T3) ELISA Kit Protocol

Vitamin B 12 - A review of analytical methods for use in food. Government Chemist Programme Report

Nursing 113. Pharmacology Principles

Direct Antiglobulin Test (DAT)

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

The Need for a PARP in vivo Pharmacodynamic Assay

Introduction To Real Time Quantitative PCR (qpcr)

Medical Laboratory Technology Program. Student Learning Outcomes & Course Descriptions with Learning Objectives

Mouse krebs von den lungen 6 (KL-6) ELISA

Guidelines for the diagnosis and treatment of Cobalamin and Folate disorders

LC-MSMS - state of the art in endocrinology

QuickTiter Hepatitis B Surface Antigen (HBsAg) ELISA Kit

Content Sheet 10-1: Overview of External Quality Assessment (EQA)

Pantesin Effective support for heart healthy cholesterol levels*

PNA BRAF Mutation Detection Kit

Calcium. Table 1: Difference between method means in percent

LIAISON XL HBsAg Quant

Hypothyroidism clinical features and treatment. 1. The causes of hypothyroidism

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

serum protein and A/ G ratio

Size Exclusion Chromatography

Non Specific Binding (NSB) in Antigen-Antibody Assays

Activity 4 Long-Term Effects of Drug Addiction

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

Crucial role of methyla0on on SAMe and Oxida0ve Stress

High Throughput Assays for Mouse Metabolic Markers: Insulin, Leptin and Adiponectin

ab Protein Sumoylation Assay Ultra Kit

Hepatitis C. Laboratory Tests and Hepatitis C

Custom Antibodies & Recombinant Proteins

6 Characterization of Casein and Bovine Serum Albumin

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Some Immunological Test. Presented by Alaa Faeiz Ashwaaq Dyaa Aseel Abd AL-Razaq Supervised by D.Feras

Page 1. Name: 4) The diagram below represents a beaker containing a solution of various molecules involved in digestion.

HiPer RA Test Teaching Kit

WHO Prequalification of Diagnostics Programme PUBLIC REPORT. Product: Genscreen ULTRA HIV Ag-Ab Number: PQDx Abstract

27E10: A unique monoclonal antibody against MRP8/14 (S100A8/A9, Calprotectin)

Dot Blot Analysis. Teacher s Guidebook. (Cat. # BE 502) think proteins! think G-Biosciences

Canine Creatine Kinase MM isoenzyme(ck-mm) ELISA. kit

William Shaw, Ph.D. The Great Plains Laboratory, Inc., Lenexa, Kansas, USA

Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma

Vitamin B 12 Deficiency Diagnosis and Markers

TECHNICAL BULLETIN. Glucagon EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0202 Storage Temperature 20 C

TOTAL PROTEIN FIBRINOGEN

Free Testosterone Cat# 2924Z

Blood Testing Protocols. Disclaimer

Rat Creatine Kinase MB Isoenzyme (CKMB) ELISA

Sex Hormone Testing by Mass Spectrometry

PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required.

Human IGFBP-3 ELISA Kit (higfbp-3-elisa)

Detailed Course Descriptions for the Human Nutrition Program

1.5 Function of analyte For albumin, see separate entry. The immunoglobulins are components of the humoral arm of the immune system.

10.1 The function of Digestion pg. 402

Measuring Protein Concentration through Absorption Spectrophotometry

OxiSelect Advanced Glycation End Product (AGE) Competitive ELISA Kit

Beware that Low Urine Creatinine! by Vera F. Dolan MSPH FALU, Michael Fulks MD, Robert L. Stout PhD

Thyroid Stimulating Hormone. 3rd Generation Ultra Sensitive Assay

CatCombi Research ELISA Kit

VITAMIN B12 STATUS AND ABSORPTION USING HOLO-TRANSCOBALAMIN IN YOUNG MEN AND WOMEN

How To Test Mouse Tnf Alpha

Automated Patient Barcode Tracking and Sample Preparation Using the Gilson GX 281 Barcode Matching System

Amylase and Lipase Tests

Biochemistry. Entrance Requirements. Requirements for Honours Programs. 148 Bishop s University 2015/2016

Blood-Based Cancer Diagnostics

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Immunoglobulin E (IgE) concentrations in Human. Immunoglobulin E (IgE) Human ELISA Kit

Course Curriculum for Master Degree in Medical Laboratory Sciences/Clinical Biochemistry

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

PRINCIPLE. REF (200 tests/cartridge) REF (400 tests/cartridge) ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

IgE (Human) ELISA Kit

Direct Antiglobulin Test (DAT)

Antioxidant Products. A comprehensive range of. Antioxidants

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit

Creatine Kinase Activity Colorimetric Assay Kit ABE assays; Store at -20 C

Transcription:

ACTIVE-B12 EIA the next level of B12 testing

Vitamin B12 an essential nutrient Vitamin B12 is an essential nutrient (can only be obtained from the diet) and is a vital component in many cellular functions including DNA synthesis. Deficiency can result in cognitive problems, dizziness and numbness and if left untreated, irreversible neurological damage. Vitamin B12 deficiency is a major public health issue and is widespread. Estimates suggest that up to 20% of the elderly population may be deficient or deplete in Vitamin B12 1 and with an increasingly ageing global population the situation will only worsen. Among other population groups at risk are pregnant women and their offspring, vegetarians, and patients with intestinal diseases or those taking acid suppressants. Left untreated, B12 deficiency can result in irreversible neurological damage. Early and accurate detection of Vitamin B12 deficiency is therefore vital. Diagnosis of B12 deficiency is notoriously difficult; the classic haematological signs and symptoms may be absent or non-specific and currently-used laboratory methods can give misleading results. The Active-B12 EIA is an innovative new method for assessing Vitamin B12 status and offers improved accuracy, sensitivity and specificity over current laboratory methods.

What is Active-B12? Three carrier proteins are involved in the transport of Vitamin B12 around the body - Intrinsic Factor (IF), transcobalamin (TC) and haptocorrin (HC). When transcobalamin and haptocorrin bind Vitamin B12 the resulting complexes are known as holotranscobalamin (HoloTC) and holohaptocorrin (HoloHC). HoloTC represents only 10-30% of the Vitamin B12 circulating in the blood but is the ONLY form of Vitamin B12 that is taken up and used by cells of the body, hence it's other name... ACTIVE-B12. Only transcobalamin transports Vitamin B12 from its site of absorption in the ileum to tissues and cells. The vitamin is then internalised as the Active-B12 complex via a specific receptormediated uptake. This process delivers Vitamin B12 into the cells of the body and provides the vitamin as an essential co-enzyme for vital cellular functions such as DNA synthesis. The remaining 70-90% of circulating Vitamin B12 is bound to haptocorrin, the function of which is unknown. Also, as Active-B12 has a shorter circulating half-life compared to holohaptocorrin, the earliest change that occurs on entering negative vitamin B12 balance is very likely to be a decrease in Active-B12 concentration 8. Vitamin B12 in the circulation Holohaptocorrin Biologically inert 70-90% Active-B12 (Holotranscobalamin) Biologically active 10-30%

Measuring B12 The current front-line test for assessing Vitamin B12 status is the total B12 assay but this test has a number of important limitations: False positives A proportion of individuals with Total B12 levels below the common cut-off of 148pmol/L (200pg/mL) show no clinical or biochemical evidence of deficiency 2. False negatives Conversely, neuropsychiatric and metabolic abnormalities can occur with total B12 concentrations well within the normal reference interval 2,3. Measures all circulating Vitamin B12 But not all B12 in the blood is available to be used by the body. Only B12 bound to transcobalamin, Active-B12, is taken up from the blood into the cells of the body. Large proportion of indeterminate results There are many publications attesting to a significant indeterminate zone when using the Total B12 assay 4,5,6 It is estimated that approximately half of patients with B12 deficiency are not detected when the Total B12 test is used with a cut-off of 148pmol/L (200pg/mL) 7. Advantages over Total B12 testing Total B12 Active-B12 Sample denaturation YES NO Analyte Active and inert B12 Biologically-active portion only Early marker of B12 status NO YES % indeterminate results 9 45% 14%

Performance of Active-B12 Active-B12 offers a more accurate assessment of Vitamin B12 status than Total B12 or MMA 9. Sensitivity 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 AUC No discrimination Active-B12 0.90 Serum B12 0.80 MMA 0.78 0 0.2 0.4 0.6 0.8 1 1- Specificity (false positives) AUC No discrimination Active-B12 0.90 Serum B12 0.80 MMA 0.78 Using Active-B12 Active-B12 may be used as a direct replacement for the total B12 test or as a secondary test to resolve total B12 indeterminate results 10 : Subjects at risk of B12 deficiency Active-B12 <35pmol/L Active-B12 35pmol/L Likely deficient Unlikely deficient* * Renal patients should be further investigated Total B12 test <150pmol/L 150 300 pmol/l >300pmol/L Likely deficient Resolve with Active-B12 Unlikely deficient* * Due to false positives and false negatives, all total B12 results could be confirmed with Active-B12

Active-B12 EIA A novel monoclonal antibody has been developed which is highly specific for holotc, allowing simple, direct immunoassays for quantifying Active-B12. Such assays remove the need for the cumbersome preanalytical denaturation steps needed for most Vitamin B12 assays thereby removing a source of variability. Part Number FMABT100 Method Kit Components Sample Type Sample Preparation Sample Volume Calibrators Controls Substrate Reference Method Enzyme Immunoassay (EIA) Break-apart wells coated with specific antibody Ready-to-use EIA reagents Compatible with liquid-handling automates Serum (including gel tubes) 1:1 Dilution (diluent provided) 100µL for duplicate 6, recombinant holotc, liquid, ready-to-use 2, recombinant holotc, liquid, ready-to-use pnpp at 405nm Abbott AxSYM Active-B12 n=107, r=0.93, EIA = 1.2 + 0.94 x AxSYM References 1. Pfeiffer C et al Am J Clin Nutr 2007;86:718-27 2. Green R et al. Baillieres Clin Haematol.,1995;8:533-6 3. Lindenbaum J et al., New Eng J Med., 1988; 318: 1720-8. 4. Snow CF Arch Intern Med., 1999 ;159 :1289-98. 5. Swain R J Fam Pract., 1995; 42: 595-61. 6. Hvas AM et al., Ugeskr Laeger., 2003; 165: 1971-6. 7. Herrmann W et al Curr. Drug Metab. 2005; 6 : 47-53 8. Herzlich B and Herbert V, Lab Invest., 1988; 58: 332-7. 9. Valente E et al Clin Chem 2011;57:6 856-863 10. Herrmann W and Obeid R in "Labor und Diagnose" (Editor L. Thomas), edition 8, Chapter 13. Axis-Shield The Technology Park Dundee DD2 1XA Scotland UK T: +44 (0)1382 422000 F: +44 (0)1382 422088 E: active-b12@axis-shield.com www.active-b12.com Distributed by: FMABT100-V3 04/12