SuperEndo B&L-alpha II Cordless Heat Carrier Operation & Maintenance Instruction Manual



Similar documents
3 WATT LED SPOTLIGHT Model No. SLM

RomiApex A-15. APEX LOCATOR User Manual

2 YEAR WARRANTY S7200PAU USE & CARE MANUAL ADVANCED CERAMIC TECHNOLOGY. To register your product go to

CanalPro TM Apex Locator

CappController Pipette Controller. Operation Manual Version:

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

How To Use A Power Supply Unit (Upu)

Contents. Product Code Page 1

16/32 Channel 1U Rack Mount CCTV Power Supply

2013 VTech Printed in China US

Operating instructions in the back. PD1020L

SDX Submersible Depth Transmitter User Manual

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

User s Manual AURORA 1.2K/2.2K

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

How To Use A U.S. Cell Phone At Home

Micro Hair Extension Machine Model EX-P100 Patent-pending. Operating Manual

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

Runtastic rechargeable battery for iphone 4, 4S

Wine Cooler with Thermo-Electric Cooling & Heating Technology

PAR Tablet 10 Quick Start Guide

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Copyright. Trademarks

AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power

Nokia Bluetooth Headset BH-110 User Guide

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

Quick start guide smart.power smart.power smart.power

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Owner s Manual & Safety Instructions

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

900 MHz Lightweight Wireless Stereo Headphones

Nokia Bluetooth Headset BH-109

Bottom Loading Water Dispenser

NFC Communication Tray Model: HHX-IT3-Z

TV Ears 5.0 Digital & Dual Digital Quick Start Guide

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

User s Manual. Copyright 2014 Trick Technologies Oy

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Meaco 30L and Meaco 40L dehumidifier instruction manual

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

Content Ⅰ Safety caution Ⅱ Introduction and technical parameter Ⅲ Standard configuration Ⅳ Structure and theory Ⅴ Assemble Ⅵ Function and settings

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Copyright. Trademarks

Use and Care Manual. Model CPA12KH AIR CONDITIONER

HAIR CLIPPER. Model No. HC5150 HC

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

7 High-Resolution Digital Photo Frame

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

The Third Rail System User Manual

Geocontrol PRO INSTALLATION AND OPERATION MANUAL. Rev. 1 03/18/04 Part #

Dehumidifier Users manual. For Models: DH45S DH65S

Nokia Bluetooth Headset BH-607. Issue 2. 1

TS1200 Intelligent Lead Free Soldering Station. Operation Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / Instruction Manual. Page 1 of 9

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

G1 GPS Sensor User Manual

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

User s Manual. Bluetooth Calculator Keypad. Page

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

car + boat Box Contents x2 x _DC16_CAR_BOAT_OPSMAN.indd 1 29/7/08 15:27:01

Installation and Operation Guide for PD5100 Automatic Transfer Switch

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

BEP FD-2 CONTOUR MATRIX FUME DETECTOR

User Manual Color video door phone

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

GENANO 4500 MEDICAL AIR PURIFICATION DEVICE

Table of Contents TO OPERATE THE 12.0 VOLT POWER PACK: THIS OPERATES ONLY OFF THE UNIT S RECHARGEABLE BATTERY, NOT OFF YOUR VEHICLE S BATTERY.

CompacVideo Otoscope. Model (NTSC) and 23120P (PAL) Operating Instruction Manual

Mini Power Bank and Charger

Transcutaneous Electrical Nerve Stimulation Device LUMI-TENS

Cable Tester Pro ORDERCODE D1909

User Manual THR840DUK Digital Thermostat

Hot Water Urns. all models. Helpline. v3.0

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Owner s Manual & Safety Instructions

OC-3 SERIES OF PRINTERS

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

ROTOR LOADER OWNER S MANUAL

Nokia Bluetooth Headset BH /1

Ride-on Car OWNER S MANUAL KT1151TG. Keep instructions for future reference

National- Spencer Inc.

User Guide Nokia Portable Wireless Charging Plate DC-50

Weather Radio Alarm Clock

Operating Instructions Bedienungsanleitung Mode d emploi

Laptop Power Adapter for home/office User Manual

ENGLISH...3 DEUTSCH...13 FRANÇAIS...23 ESPAÑOL...33 ITALIANO...43 PORTUGUÊS...53

How To Set Up An Ecm Display On A D210 (D210) (D2) (Ecm) (Emc) (Mcd) (Power Supply) (Mm) (Camellom) (Ios)

PRODUCT SUPPORT MANUAL HEARING AID CONTROLS HELPFUL HINTS HEALTH & SAFETY WEEE DIRECTIVE

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

Mini-led spotlight with magnetic base

Transcription:

SuperEndo B&L-alpha II Cordless Heat Carrier Operation & Maintenance Instruction Manual PLEASE READ ALL INSTRUCTIONS PROVIDED FOR THIS DEVICE BEFORE USING IT. Caution: This product should only be used by dental professionals after reading the instruction for use. FULLY CHARGE BATTERY IMMEDIATELY UPON RECEIPT AND PRIOR TO FIRST USE.

Table of Contents 6 7 8 8 9 9 0 Introduction Safety Instructions Contraindications Features Product Description How to Install/Change the Battery Pack Attaching Pluggers to the Heating Unit Caution During the Usage of this Device Charging the Battery Technique Overview Technique Tips Troubleshooting Sterilization & Maintenance Warranty CAUTIONS This equipment conforms to the requirements of Medical Device Directive 9//EEC and satisfies the electrical safety requirements of EN 6060- and Electromagnetic emissions and immunity standards of EN 6060--. These limits are designed to provide reasonable protection against harmful interference in a typical medical installation. However, because of the proliferation of radiofrequency transmitting equipment and other sources of electrical noise in healthcare environments (for example, electrosurgical units, cellular phones, mobile two-way radios, electrical appliances and high-definition television), it is possible that high levels of such interference due to close proximity or strength of a source, may result in disruption of performance of this device. WARNING Risk of Fire, Risk of Burning Keep the heated tip away from skin and anything that is flammable.

Introductions Thank you for purchasing the Alpha II obturation device from B&L Biotech, Inc. The Alpha II supports obturation techniques that require warm vertical compaction of gutta-percha or Resilon root canal filling materials. READ THIS MANUAL CAREFULLY AND BE FAMILIAR WITH ALL SAFETY PRECAU- TIONS PRIOR TO USING THIS DEVICE. Safety Instructions Improper usage of this device may cause injury to patients, operators and dental assistants, and/or damage to the product. It is intended exclusively for use by licensed dentists and endodontists only. Plugger Tips are very hot when device is activated, thus care must be taken by the dentist, assistant and patient not to contact the tip while hot. Usage of a rubber dam is strongly recommended for proper isolation of the tooth. The temperature of the Plugger can reach 0 C, therefore, it should not be used inside the root canal for more than seconds at a time. Plugger Tips must be sterilized before first use and between patient uses. For sterilization of tip, temperature must not exceed more than C in the autoclave. 6 7 Contraindications Do not use any other Plugger Tips except the ones supplied by B&L Biotech. Use of any Plugger or battery that is not supplied by B&L may result in electrical shock, fire, or explosion and void Warranty. Do not use the Alpha II device on patients with pacemakers. Do not use the Alpha II device when the battery level displays red light. Charge the unit and wait for the device to display the green light. It is recommended that battery be fully charged before using the Alpha II device for the first time. Allow approximately hours for full charge. The actual temperature of a Alpha II Plugger is within a range of +/- 0 C of the temperature displayed on the unit. DO NOT use disinfectants that contain Bleach or Ammonium Chloride to clean the device. DO NOT autoclave the Heating Unit or Charging Base.

Features B&L-ALPHA II PACKAGE CONTENTS Heating Unit Charging Base Battery Adapter V, 60mAH Power Cord Directions For Use Pluggers Available Pluggers Include (Tip Size / Taper): 0/0 /0 0/0 /0 /06 /08 /0 60/ /08L Spreader/S Spreader/T Thermal Tester SPECIFICATIONS Charging Base Dimensions: 8mm X 7mm X 6mm Charging Base Weight: 07g Heating Unit Dimensions:.mm X 0.mm X.mm Heating Unit Weight: 6g TECHNICAL DATA Battery: Li-Ion.7V Source: 00~0V / 0~60Hz, DC V, 80mA Operating Temperature: 0ºC to ºC, Storage Temperature: -0ºC to 60ºC STANDARD SYMBOLS Class II Equipment Type B Applied Part Caution 60ºC Consult Instructions For Use Keep Dry -0ºC Temperature Limitaion Date of Serial Authorized Manufacture Number Representative CE Mark

Product Description 6 7 HEATING UNIT Plugger Plugger Attachment Cap Heater Switches Battery Level Indicator Temperature Display Power ON/OFF Switch / Temperature Selection- Powers the unit on and off, and changes the temperature setting Battery Casing CHARGING BASE Charging Status Indicator Charging Contact Terminals 6 7 BATTERY POWER ADAPTER

How to Install/Change the Battery Pack Insert the Battery Pack into the Heating Unit as shown in the pictures. Thread the Battery Casing onto the Heating Unit. Caution: Ensure threads are aligned and avoid excessive forces when threading the Battery Casing onto the Heating Unit. When replacing the battery, turn the Battery Casing counterclockwise. Separate the Battery from the connector of the Heating Unit. See and above for installation instructions. (Caution: When inserting the battery, make sure the connector is properly set). Attaching Pluggers to the Heating Unit Press the Power ON/OFF Switch button. If lights do not display, check the Battery connection. If the display window shows opn, this indicates that the Plugger is not connected properly. When the Plugger is connected properly, the default temperature of 00 C or the last temperature setting will appear. To change the temperature setting, press the Power ON/OFF Switch until reaching the setting you desire. Pressing the switch will rotate temperature settings in the following order; 0 C >80 C > 00 C > 0 C >0 C. Recommended Temperatures: Gutta-percha - 00 C Resilon - 0 C Caution: Plugger is extremely hot during use. Avoid direct contact with the patient s soft tissue in the oral cavity. Inserting Plugger Note: The mouth of the Heating Unit has 6 different slots for inserting the Plugger. Select the appropriate one based on your preferred orientation of the Heater Swiches in relation to the Plugger tip.

Heating the Plugger Once the Plugger is properly connected to the Heating Unit, press the Power ON/OFF Switch to turn on the unit. When the power is on and the Plugger has been properly installed, the temperature will be displayed on the screen. Change the temperature if necessary. Heating the Plugger occurs by pressing (and holding) either one of the two Heater Switches. Releasing the Heater Switch allows the Plugger to return to room temperature. During normal operation, a beeping noise will indicate that the Plugger is hot. Do not touch the Plugger until it has a chance to return to room temperature. 6 7 Caution During the Usage of this Device The Alpha II Heating Unit is designed to turn-off automatically if the battery should begin to overheat. While the chance of this occurring is rare, if it occurs, please allow the Heating Unit sufficient time to cool. Then, recharge the Heating Unit by placing it on the Charger Base for at least 0 seconds before attempting to use again. Heat activation of the Plugger inside the canal should not exceed more than seconds. This device shuts off automatically if not used for more than 0 minutes. Press the Power ON/OFF Switch to turn on the unit. The tip of the Plugger is very hot during use. Please perform all endodontic procedures with a rubber dam. For safety purposes, place the tip of the Plugger at the orifice of the root canal before activating the Heater Switches. Use caution to avoid contact to the soft tissue of the oral cavity while the Plugger is hot. When replacing the Plugger, turn the power off and ensure the Plugger has cooled down sufficiently. The Plugger should be sterilized prior to use. The Plugger can be sterilized in an autoclave in accordance with the sterilization guidelines of the autoclave s instruction manual. NOTE: This device is only intended for use during root canal therapy. Use extreme caution with the Heating Unit so as not to burn the patient or oneself. 6

Charging the Battery Keep the Heating Unit on the Charging Base while the unit is not in use. The Device is ready for use when the LED charging status indicator displays a green light. Once a red light on the Battery Indicator of the Heating Unit starts to flash, the unit needs to be recharged by carefully positioning the Heating Unit on the Charging Base ensuring the proper contact is made. Once the battery is fully charged, the LED charging status indicator will turn green. Charging (Amber) Fully charged (Green) Connect the Power Adapter to the Charging Base. Position the Heating Unit on the Charging Base correctly so that the Battery Charging Contact Terminals on the bottom of the Heating Unit align with the two Charging Contact Terminals on the Charging Base with the temperature display window facing upwards. If the correct connection is made, the LED charging status will display an amber light during charging. Once the battery is fully charged, the LED charging status indicator will turn green. Note: If the LED is neither yellow or green, the charging terminals are not properly connected. Re-align the Heating Unit on the Charging Base and also check that you are getting power to the Charging Base. Pluggers should be removed while charging. Please keep the pluggers disconnected from the unit after each treatment. To confirm whether the battery is fully charged, separate the unit from the Charging Base and turn on the Heater Switch. If there are levels of the green LED displayed, the unit is fully charged. Reamaing Battery Level 00% 70% 0% 0% Note: If the unit has not been in use for more than a month, it may not function correctly due to natural discharge of the battery. Monthly recharging is recommended even when the unit has been fully charged but is not in use. 7

Technique Overview STEP : CONE FIT Select a cone that fits snuggly to Working Length (WL). Trim 0.mm from the tip. Note: Do not use sealer for this step. STEP : PLUGGER FIT Choose the Alpha II Plugger which most closely matches the taper of the prepared canal. Place the Plugger into the canal until it binds. Note: Plugger tip should be approximately to 7 mm short of WL. Move the rubber stop to indicate the maximum depth of penetration. STEP : CONDENSE CONE WITH HAND PLUGGER Coat the cone (fitted in step ) with sealer and push it as far into the canal as possible. Note: Tip should be approximately 0.mm from WL. Use the Alpha II to sear off excess cone material at the canal orifice. Use a hand plugger to condense the cone. STEP : CONDENSE CONE WITH ALPHA II PLUGGER Activate the button to bring the Alpha II Plugger to the desired temperature. Note: 0 C for Resilon and 00 C for GP is recommended. Advance the Plugger apically until reaching the depth indicated by the rubber stop (set in step ). Release the button to allow the Plugger to begin cooling, while at the same time holding continuous apical pressure, hold for seconds. Remove the Plugger from the canal. Note: if there is a tendency for the cone to come out with the Plugger activate the button to heat the Plugger again (allow it time to reach set temperature) before trying to remove the Plugger from the canal. STEP : CONDENSE SHORTENED CONE WITH HAND PLUGGER. BACKFILL Use a small hand plugger to condense the remaining cone apically. Set the rubber stop (same depth as Step ) and condense the remaining material. Backfill to the orifice with SuperEndo Beta (see Beta instructions for details). Technique Tips It is important to select the appropriate Plugger size and taper. The Plugger s Tip should meet resistance within to 7 mm of the Working Length. Do not advance the gutta-percha beyond the binding point. If the gutta-percha is advanced beyond the binding point, there will be no pressure applied to the gutta-percha while it is cooling. Therefore, use a hand Plugger and apply direct pressure. If the temperature exceeds 00 C, the gutta-percha may become soft and could be ineffective during compression. If a large amount of gutta-percha is used, raise the temperature setting to 0 C. After sustained push, let the Plugger cool before the removal from the canal. This reduces the chance of pulling the filling back out with the Plugger. 8

Troubleshooting Code Description or possible causes Recommended action for the user Er0 Defective Microprocessor If this error code is displayed on the screen please contact authorized dealer s customer service department. opn SHR HD This message will be displayed on the screen if the Plugger is not correctly connected to the unit and if the heating mechanism is not working properly. Desired temperature not reached in 00 seconds: defective plugger or low battery power. Temperature does not change within seconds after activation: Defective plugger. Power turns off while in use and power does not turn on again. Separate the Plugger from the unit and reconnect the Plugger. If proper temperature setting is displayed, it indicates normal state. If the same message is displayed, replace with a new Plugger and check to see if same problem occurs. If same problem occurs, please contact authorized dealer s customer service department. Recharge the battery or replace the plugger. If the code does not disappear, return the unit to authorized dealer for replacement. Replace the plugger. If the code does not disappear, return the unit to authorized dealer for replacement. A. This may result from the Device overheating. Let the unit cool and retry. B. Recharge. C. If the same problems occur after recharging, change the battery. Sterilization & Maintenance Keep this device at room temperature away from external shock or direct sunlight. Heating Unit and Charging Base Clean the exterior of the Heating Unit and Charging Base by using a soft cloth moistened with a mild detergent or rubbing alcohol. The surfaces should be sheathed with plastic barrier to prevent contamination and discoloration. The use of non-recommended cleaning agents could result in damage to the outer surface of the Alpha II Device. DO NOT use strong disinfectants or those that contain Bleach or Ammonium Chloride to clean the device. DO NOT autoclave the Heating Unit or Charging Base. Plugger After each use, the Plugger should be sterilized by autoclave for 60 minutes at ºC, PSI. Dispose of used Plugger into a biohazard container. Notice: If the unit is not used for an extended period of time (more than once per month), it may not work because of battery discharge. Periodical (once per month) recharge is recommended even if the Device is not used. It is recommended to change the battery every 6 months. Please contact authorized dealer to purchase a replacement battery. 9

Warranty B&L Biotech, Inc. warrants the Alpha II Obturation Device against defects in material and workmanship for months from the date of purchase with proper usage. During that twelve-month period, B&L Biotech will repair or replace a defective unit. Defects caused by misuse, neglect, accident or abuse are not covered by this warranty. B&L Biotech, Inc. assumes no liability resulting from improper use, damage or breakage due to misuse of the Alpha II Obturation Device product by the purchaser. The manufacturer is not responsible for breakage of any component of the Alpha II Obturation Device, including the Plugger, resulting from forceful compaction of gutta-percha or Resilon or use of the Plugger outside of the methods noted in this Instruction for Use. The battery and Pluggers in the Alpha II Obturation Device are replaceable. New batteries and Pluggers can be ordered from B&L Biotech, Inc. B&L Biotech, Inc. assumes no liability for damage to the Alpha II Obturation Device, injuries to patients or users or other problems resulting from use of accessories or other materials not supplied by B&L Biotech, Inc. For Sales Orders and Product Information Contact: Manufactured by: B&L Biotech, Inc. 0, Gungjun tower, 77- Gojan-dong, Danwon-gu, Ansan-si, Gyeonggido, Korea -906 www.bnlbio.com EMERGO EUROPE Molenstraat, BH, The Hague, The Netherlands tel. + 70 870 tel. + 70 6 799 0

UM-A-0 Rev.00