Aluminum Phosphide Fumigants & Fumigation Management Plans



Similar documents
FUMIGATION MANAGEMENT PLAN TEMPLATE

Grain Bin Fumigation. Legislative Requirements and Guidelines. Crystal Lafrance Ministry of the Environment London Regional Office Feb.

Draft - Fumigation Management Plan

FOR ADDITIONAL INFORMATION, PLEASE SEE THE NDA S WEBSITE AT THE FOLLOWING URL:

Framework for a National Soil Fumigation Manual and Exam Question Item Bank February 2011

Commodity Fumigation

Knowledge Expectations for Field Fumigation Pest Control (Subcategory O) Revised January Knowledge expectations from study guide chapters 1 8

Questions & Answers About. Fumigation. Department of Consumer Affairs Structural Pest Control Board

ProFume* Gas Fumigant

Millersville University - Office Of Environmental Health & Safety Scope & Application

Safety Meeting Topic: Chemical Spills and Emergency Action Plans for General Industry

Directions to Students

PHASE 2 SOIL FUMIGATION MANAGEMENT PLAN (CHLOROPICRIN ONLY PRODUCTS)

Carefully to Carry. Fumigation of ships and their cargoes

Confined Space. Entry. Course Preview TRENCHSAFETY

Various ways are used to

Sulfuryl Fluoride Structural Fumigation

Confined Spaces. Notes

File: Spill Response Plan for Hazard Chemicals and Mercury Spills. Orig. Date: 12/01/2005 Review Date: January Review Date: March 2010

SAFETY AND HEALTH PROGRAM

Standard Operating Guideline Pest/Rodent Control

ENVIRONMENTAL HEALTH AND SAFETY HAZARDOUS MATERIALS MANAGEMENT PLAN

History of the SPCC Rule

CONFINED SPACE ENTRY NON-MARINE FACILITES

Mechanical Systems Competency 1.20

University of Pittsburgh Safety Manual. EH&S Guideline Number: ASBESTOS

HealthandSafetyOntario.ca. What is a work permit? Why use a work permit? Types of work permits. When is a work permit needed?

SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 3.1. Substances Not applicable 3.2. Mixture

Company Name Chemical Spill Prevention & Clean-up Procedures Program. Last Revised On 00/00/0000

ASBESTOS MANAGEMENT PROGRAM

CHEMICAL SPILL MANAGEMENT GUIDELINES

Hazardous Material Waller County ARES training material used with permission from Christine Smith, N5CAS.

HAZARD COMMUNICATION & THE GLOBAL HARMONIZING SYSTEM EMPLOYEE TRAINING

WORKING IN CONFINED SPACES GUIDELINES

Based on the initial size-up and any information available, Command will formulate an action plan to deal with the situation.

MOFARNO 160EC MATERIAL SAFETY DATA SHEET. SECTION 1 Chemical product and Company identification

Trade Name of this Product Isopropyl Rubbing Alcohol 91% USP. Corporate Compliance Team 1666 East Touhy Avenue

MATERIAL SAFETY DATA SHEET

112(G) FUMIGATION IN VIRGINIA. Stanley Faggert Virginia Department of Environmental Quality (DEQ) Minor NSR Coordinator December 9-11, 2014

Confined Space Procedures

READ FIRST. Confined Space Entry Procedure. San José State University Environmental Health and Safety. Confined Space Entry Procedure

Division of Public Health Administrative Manual

Safety, Health, and Environmental (SHE) Program Visitor Awareness Training (SHE 101V)

Safety Data Sheet for Whole Grain

ITEM RODENT AND VERMIN CONTROL - INITIAL SURVEY. BAITING AND SANITATION ITEM 634

Pesticides and Alternatives to Pest Control

INTEGRATED PEST MANAGEMENT

TARLETON STATE UNIVERSITY HAZARD COMMUNICATION PROGRAM

Havoc Rodenticide Bait Packs (Pellets) Kills Rats and Mice

Hydrogen Sulfide Monitoring and Safety. Nova Safety & Environmental Midland, Texas

South Carolina Child Care Services. Child Care Emergency Plan Template

SAFETY TRAINING CLASSES & SERVICES LIST

Safety Data Sheet. Product #: Aspira Scientific 521 Cottonwood Dr. Milpitas, CA

FINAL RODENTICIDE COMMERCIAL KILLS RATS & MICE

RECOMMENDED COFFEE WAREHOUSE STORAGE PRACTICES

PITTSBURG TANK AND TOWER CO., INC.

RESPIRATORY PROTECTION PROGRAM

Integrated Pest Management At Boise State University

MATERIAL SAFETY DATA SHEET

68 Metal Industry Guidelines for Safe Work

Dukes of Hazard Activity Time:

Issue VI. In this issue: Phostoxin Applicator's Manual Update. Degesch Phosphine Generator Update. Profume. Conventions and Conferences

HealthStream Regulatory Script

Design of Closed-loop Fumigation Systems for Grain Storage Structures

Work Permits. A Health and Safety Guideline for Your Workplace. When is a Work Permit Needed? What is a Work Permit? Why use a Work Permit?

Calendula Extract Safety Data Sheet

CONFINED SPACE POLICY

advice (show the label where possible).

BUILDING A WORLD OF DIFFERENCE. Safe work in confined spaces

CHEMICAL SPILL RESPONSE GUIDE

Out-of-State Electrician Electrocuted While Restoring Service at a Personal Residence Incident Number: 08KY065

Confined Space Plan Prepared by: Environmental Health and Safety Office October, 2014

ALLEGANY WIND POWER PROJECT CONSTRUCTION SPILL PREVENTION PLAN

OSHA Training Guidelines (An Unofficial Summary)

CHEMICAL SUICIDE. Safety Alert

Guide to Fumigation Under Gas-Proof Sheets

Waste Management Program

Hazardous materials can be silent killers. Almost every household and workplace has varying amounts of chemicals that, if spilled or combined, will

Compressed Gas Cylinders Safety Policy

Confined Space Training

SAFETY DATA SHEET. Trade name: Master Clear Seal-5 Revised: 5/29/2015

Safety and Health Resource Manual. Sample Permit-Required Confined Space Written Program

Oregon State Library Policy

ABC CIRCUITS 10 Circuit Drive Circuit Town, IN SLUG CONTROL PLAN

SMOKY LAKE COUNTY. Title: Risk Control: Odorant-Mercaptan Policy No.: C Section: 14 Page No.: 1 of 12 E

TEXAS TECH UNIVERSITY HAZARDOUS WASTE PROGRAM DEPARTMENT OF ENVIRONMENTAL HEALTH AND SAFETY

: Water and Glycol Leak Detection Solution

TRICHLOROACETIC ACID SOLUTION Department of Pharmacy Duke University Medical Center Box 3089 Durham, NC

Flammable and Combustible Liquids. Slide 1 (of 23)

SCBA Frequently Asked Questions

CLEANING AND SANITIZING

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.0 Revision Date 02/27/2010 Print Date 08/25/2011

INTEGRATED PEST MANAGEMENT

WORKSAFE VICTORIA A HEALTH AND SAFETY SELF-ASSESSMENT CHECKLIST FOR SMALL BUSINESS

PURPOSE A confined space is any area or vessel, which meets all three of the following:

MATERIAL SAFETY DATA SHEET

EMERGENCY CONTINGENCY PLAN

SECURITY VULNERABILITY CHECKLIST FOR ACADEMIC AND SMALL CHEMICAL LABORATORY FACILITIES

AOP: Storage, Transportation, Decontamination, and Spill Containment of Lampricides and Lampricide Application Equipment

FDNY C14 Certificate of Fitness Quiz

Transcription:

2/4/2013 1

Aluminum Phosphide Fumigants & Fumigation Management Plans Leilani Monson, RN Oregon OSHA 2/4/2013 2

Fumigants : Active Ingredients Methyl bromide Chloropicrin Metam sodium (Vapam) Metam potassium (K-Pam) Dazomet (Basamid) 1,3-Dichloropropene (Telone) Iodomethane (Midas) Dimethyl disulfide (DMDS) (Paladin) Aluminum phoshide

WHAT are the aluminum phosphide fumigants? Fumitoxin Phostoxin Gastoxin Phosfume Drex-PH3 Used to control insects and burrowing pests 2/4/2013 4

Oregon OSHA Requirements Fumigation Rules OAR 437-004-0910 Respiratory Protection OAR437-004-1041 Hazard Communication OAR 437-004-9800 Worker Protection Standard 40 CFR 170 Permit-required Confined Space 1910. 146 www.oregonosha.org

Why do we have so many rules? First, what it does to the body.. 2/4/2013 6

The product reacts with water/moisture and makes deadly phosphine gas. Works great for pests not so good for humans and pets. 2/4/2013 7

As you breathe phosphine the acid in the gas dissolves your lung tissue. Your damaged lungs can t take in oxygen from the air.

Fluids build in your lungs Your lungs become overwhelmed and you drown in your own fluids. Pulmonary Edema

Heart becomes oxygen deprived Lack of oxygen stimulates heart to beat faster The heart races uncontrollably to try to save itself. The heart stops. You die quickly.

And If your not lucky enough to die quickly... Liver & kidney functions are overwhelmed by phosphine You are dying slowly and painfully As tissues deteriorate infections set in, Pneumonia ravages the body

Why all the rules? The stories speak for themselves.. 2/4/2013 12

Acute phosphine poisoning aboard a grain freighter- 2 children plus 29/31 crew members; 1 child dies, late 1970 s Atlantic Ocean Fumigant Intoxication during transport of grain by railroad- 3 Federal Grain inspectors sickened, Portland Oregon May 1980 Deaths Associated with Exposure to Fumigants in Railroad Cars US- 12 y/o boy- El Paso Texas 1993, 23 y/o male, Maxwell CA 1989 Drum containing 37 flasks of Fumitoxin recovered from a grain elevator fire explodes seriously injuring 1 employee, Sheridan OR 1993 2/4/2013 13

Partially spent Fumitoxin confined in a dumpster explodes, almost ignites building. Hubbard, OR 1997 Application of Fumitoxin pellets used for gophers & ground squirrels kills Bridget Carlson, 5; sickens family. Salem, SD 2000. Two people die after handling deadly pesticide. Enterprise, Alabama. January 2002. Man pleads guilty to manslaughter in poisoning death Mitchell, SD. September 2005 Fumitoxin ignites at Syngenta Seed Plant, sickens workers in nearby building. Nampa,ID, 2007. 2/4/2013 14

2010 Utah Fatalities Rebecca, 4 years Rachel, 15 months 2/4/2013 15

Bugman, ex-worker plead guilty in Layton pesticide deaths By JUDY FAHYS In separate plea agreements, Nocks, 64, and the company acknowledged they broke the law by using Fumitoxin in burrows within 15 feet of an occupied structure, putting too many pellets in the burrows and failing to give the Toones a safety data sheet about the dangerous pesticide. Nocks and Bugman also admitted for the first time Tuesday that they caused the death of two minor children. 2/4/2013 16

Oregon OSHA Fumigation Rules OAR 437-004-9010 You MUST follow information in each of these: Product Label Application Manual And. MSDS

Manual and label 2/4/2013 18

MSDS Information Medical specific information and treatment information to physicians in case of exposure. Hospitals will ask for the MSDS and call the emergency information number on the top of the MSDS

cdms.net/labelsmsds

Where can I start? Read the Applicator s Manual. BUT, I mean really read and understand it! OR-OSHA cites from the applicator s manual.

Cover Page 2/4/2013 28

Fumigation Management Plan (FMP) An FMP is an organized, written description of the required steps necessary ensure a safe, legal and effective fumigation. Fumigations where FMPs are required Space fumigation (Bins, flat storage, vertical storage, mills, food processing plants and warehouses, railcars, ships, trucks, etc) Burrowing pests Soil fumigation- Metam Sodium, Telone, Pic, etc. 2/4/2013 29

Types of FMP s FUMIGATION MANAGEMENT PLANS FMP for structures: Grain bins (holding all that wheat!) fall under this plan FMP for burrowing rodents FMP for soil fumigation- Metam Sodium 2/4/2013 30

The Fumigation Management Plan Components Preliminary Planning and Preparation People- working with PH3 and others around Monitoring Notification Sealing procedures Application procedures & fumigation period Post-application operations 2/4/2013 31

Aluminum Phosphide Help? www.pestcon.com

FMP for Burrowing Rodents A MAP of site 2/4/2013 33

2/4/2013 34

FMP: Burrowing Pests Application Procedures & Fumigation Prior to treating: inhabited structure, provide an MSDS or Applicator s manual to occupant. **Distance from occupied (human/animal) structure: 100 feet POST a WARNING sign to the treated area. 2/4/2013 35

Fumigation signs The regular WPS Do Not Enter sign is not acceptable for use with fumigants. The one noted here is correct. Field posting now required when treating burrowing rodents. 2/4/2013 36

FMP: Burrowing Pests Post Application Procedures Return all unused fumigant product to an approved, locked chemical storage area. Re-inspection / Re-treatment Closed burrow systems: re-inspect after 2 days Open burrow systems: re-inspect after 1-2 days. 2/4/2013 37

STORING ALUMINUM PHOSPHIDE These two signs are required to be posted on the outside of the pesticide storage area. KEEP THE STORAGE AREA LOCKED! 2/4/2013 38

FMP s for Structures Grain bins (holding all that corn!) fall under this plan. Railcars, tanks Hay storage in buildings or covered with tarp. 2/4/2013 39

FMP: Preliminary planning & preparation Review label and applicator s manual. Determine the purpose of the fumigation Elimination of insect infestation Determine the type of fumigation Type of Storage: vertical silo, farm storage, flat storage, etc. 2/4/2013 40

FMP: Preliminary planning & preparation Nearest telephone, cell coverage or other means of communication i.e. 2-way radios. Emergency shut-off stations for electricity, water and gas. Emergency telephone numbers Fire/ EMS, Police. 2/4/2013 41

FMP: Preliminary planning & preparation Exposure time considerations: temperature and moisture of commodity weather- temp humidity and wind Determination of dosage: Cubic footage of space Structure sealing capability Label recommendations 2/4/2013 42

FMP: PERSONNEL Instruct all fumigation personnel to read the Applicator s Manual regarding the health hazards. Provide required PPE, gloves, respirators. Confirm that all personnel know how to proceed in case of an emergency. 2/4/2013 43

NOTIFICATION Notify all personnel around the structure prior to application of the fumigant. Notify appropriate fire departments, police departments as per label instructions. Prepare a written Emergency Response Plan which contains instructions if phosphine levels are exceeded and could be dangerous to bystanders or domestic animals. 2/4/2013 44

SEALING PROCEDURES Sealing must be adequate to control the pests. Warning placards must be placed on every possible entrance to the fumigation structure. Lock out entry and discharge points, i.e. spouts 2/4/2013 45

APPLICATION PROCEDURES & FUMIGATION PERIOD Apply the fumigant in accordance with the label requirements Apply fumigant from the outside if possible. If you must enter the area under fumigation, work with 2 or more people under the direct supervision of a certified applicator wear appropriate respirators. 2/4/2013 46

APPLICATION PROCEDURES & FUMIGATION PERIOD Provide watchmen when entry into the fumigation site by unauthorized persons cannot otherwise be assured. When entering structures, follow OSHA rules for confines spaces. Turn off any electric lights in the fumigated area of the structure as well as all non-essential electrical motors. 2/4/2013 48

MONITORING Monitoring of fumigant concentrations must be conducted in areas to prevent excessive exposure. Keep a log of monitoring tests for each fumigation structure. Include the time and date, number of readings taken and level of concentrations found in each location. 2/4/2013 49

Types of monitoring equipment 2/4/2013 50

POST-APPLICATION OPERATIONS Aerate in accordance with structural limitations. Turn on ventilating or aeration fans where appropriate. Use a suitable gas detector (monitor) before reentry into a fumigated structure to determine fumigant concentration. 2/4/2013 51

POST-APPLICATION OPERATIONS Keep written records of monitoring to document completion of aeration. Remove warning placards when aeration is complete. Inform others when they may return to work, or be allowed to re-enter the structure. 2/4/2013 52

Deactivation methods

But what about contractors? If I have a commercial applicator fumigating for me, do I still have to do an FMP? Yes, the Certified Applicator will assist you, and you will maintain the FMP for your records. 2/4/2013 54

ELEVATORS, FLYBOYS, A PRISON AND AN EXPLOSION Pesticide Inspections Eastern Oregon Style

Toxic Elevators- A Game of Russian Roulette!

PARC Referral to OR-OSHA Grain Hauler became ill while loading his truck from a grain bin that was under active fumigation.

Hazards Identified Bins under fumigation are not labeled. Fill spouts are not locked out. Bins # s to pull from are via 2 way-radio. Bins numbers are hard to distinguish

Posting label lists fumigation ongoing from September to the following June. PPG has 20 elevators totaling 400 bins that are fumigated. Thousands of fumigations each year. Blanket notification on door of elevator FMP

FMP This is the Certified Applicator's record of fumigations. Throw tablets into grain stream. No tarping, just close bin and leave it for 21 days. No monitoring

FMP

FMP Do not calculate volume- just throw in tablets. No cell coverage, emergency phone inside the elevators. No policy or plan Applicators work alone

FMP Workers had never read label or applicators instructions. Dust masks-no respirators. Workers enter confined spaces with no monitoring

OSHA Citation OAR-0760(1)(c) lack of health hazard controls, Specifically, for not following the label and applicator manual.

Abatement FMP-completed as per manual 8 PPG EE s to fumigation training (ODA/Univar) Calculations on bins for correct dose of PH3 Calculations for ventilation done. Lock out and tags on fumigation spouts ID # s repainted contrasting color at drivers height. Bins # s to pull grain are added to the drivers Bill of Lading and invoices.

Abatement 10 MSA single gas monitors and 9 multi gas monitors purchased, calibrated and trained. Met with Fire Departments (12 involved) to train about fumigation hazards. Notified hospitals (4) of hazards of ph3. Central fumigation list on excel available at a moments notice.

WASTED! Throwing pesticide waste in the garbage does not mean the hazard is gone.

ONTARIO SANITARY SERVICE

ONE DAY AT THE RECYCLING CENTER Workers find a couple flasks after the front end loader ran over one. An unknown noxious smoke was filling up the inside of the building. Workers used water to put out the fire. This made things worse and the center was evacuated until it gassed off. 2/4/2013 69

NO RECYCLING HERE- ALL SENT TO LANDFILL

ARIAL SPRAY CO-OP

RINSING

SECURE DISPOSAL STORAGE

BREAKING DOWN BOXES

HAPPY ENDING Ontario Sanitary Service reports they are no longer receiving questionable pesticide materials. They are able to comply with DEQ and recycle the containers and cardboard.

PRISON MOLES

MAINTENANCE USES FUMATOXIN ON THE PRISON GROUNDS TO:

APPLIED TO AREAS OUTSIDE THE PERIMETER FENCING

CITATION & ABATEMENT OAR 437-001-0760(i)(c)- Did not following label or provide a fumigant management plan. Also citations for pesticide storage practices Abatement: They removed Fumatoxin from the facility, it will not be used in the future.

2/4/2013 An explosive Day in Pendleton! 8 4

2/4/2013 Deactivation container One hot day during the Pendleton Roundup, the deactivation container exploded when the applicator placed 17 pounds of partially spent socks in the container (overfilling it by several pounds per the label). Murphy s law came into play when a slow moving railroad passed by the fumigation cloud after the explosion. 4 railroad employees were exposed to the fumes. 8 5

140 flask, 15ft. from railroad tracks

HELP!!!!! www.pestcon..com cdms.net/labelsmsds Oregon Dept. of Ag Oregon OSHA Vendor of fumigant Manufacturer of fumigant. 2/4/2013 88

2/4/2013 Please use fumigants safely! Rebecca, 4 years Rachel, 15 months 8 9

Questions????????? Leilani Monson, RN (541) 388-6066 Leilani.monson@state.or.us

2/4/2013 91