HOFFRICHTER DATA box



Similar documents
Quality makes the Difference SOFTWARE MANUAL. from version

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

USB/RS485 converter cable, complete

Runtastic rechargeable battery for iphone 4, 4S

Portable Bluetooth Speaker. Quick Start Guide. Model: BTS201

User Manual (English)

NFC Communication Tray Model: HHX-IT3-Z

User Manual. Listen to your favourite songs on the radio on the road & in a car

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

FMT600BT Transmitter

MP3 Digital On-Hold Audio Systems

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

microlife PF 100 Electronic Asthma Monitor Instruction Manual (1-15) Moniteur d'asthme électronique Mode d'emploi (16-31) Monitor electrónico para el

VENTIsupport Version 1

Cable Tester Pro ORDERCODE D1909

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Getting started with

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

How To Use The Visifault Visual Fault Locator

User Manual. DXS-1000 Player

The Bouncer Bluetooth Stereo Speaker

ENGLISH USER S MANUAL. compact handheld 1D/2D code scanner

User manual. Your best protection against theft and loss. (Android) Made for

USER S MANUAL TACHOTERMINAL PRO. Firmware

Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

GLOBAL. The world s local mobile phone. Quick Start Guide

Wolverine Data PASS Portable Scanner User Manual V1.0

Wolverine 35mm Film to Digital Converter. Model F2D USER MANUAL

Instructional & Operating Manual

2 YEAR WARRANTY S7200PAU USE & CARE MANUAL ADVANCED CERAMIC TECHNOLOGY. To register your product go to

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

US Installation Manual Smappee Monitor

User Manual AUDIO OUT OFF 9V DC USB POWER. Digital On-Hold Audio System with analog line capability

ATTENTION RISQUE D ÉLECTROCUTION! NE PAS OUVRIR!

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

CappController Pipette Controller. Operation Manual Version:

Jarv Nmotion BTHL-201 Bluetooth Stereo Earbuds Users Guide

Introduction. Page 2 / 9

alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG

Quick start guide smart.power smart.power smart.power

Portable Air Conditioner

Quick Reference Guide

SPL 2-00/-01 OPERATION INSTRUCTIONS

Antenna Splitter ASA 1. Instruction manual

Rousseau 10. User Guide

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

Operating Manual Remote Cost Control Monitor

1. INTRODUCTION TO SUUNTO SMART BELT 2. GETTING STARTED WITH SUUNTO SMART BELT

Single Use USB Data Logger EBI 330-T30 / EBI 330-T85. User Manual

User Guide Nokia Portable Wireless Charging Plate DC-50


Changers Kalhuohfummi User Manual

AW10 All-in-One Printer

Quick Reference Guide

MADRIX NEO Quick Start Guide & User Manual

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

We reserve the right to make technical changes.

LED Par 56 Short DMX ORDERCODE 42421

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

UK s best selling phone brand. User Guide. BT Big Button 200 Corded Phone

UNIVERSAL BLUETOOTH KEYBOARD CASE FOR TABLETS 7-8 INCHES

7 High-Resolution Digital Photo Frame

Manual IB-3620 Series

A-Series Data Loggers PRODUCT MANUAL

ICMP HDD. Installation manual

=============================== WARNING

Technaxx DigiTape DT-01 User Manual Please find the Declaration of Conformity for this device under following internet-link:

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

Important Safeguards

Jarv Joggerz BT-301 Bluetooth Stereo Headphones Users Guide

TABLE OF CONTENTS QUICK START... 1 DIAGRAM OF THE DIGITAL PHOTO FRAME... 2 KEYPAD BUTTON FUNCTIONS... 3 REMOTE CONTROL FUNCTIONS..

Evolution Digital HD Set-Top Box Important Safety Instructions

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

CM3 Computer ohg Schinderstr Ergolding cm3@hotmail.de. USB 2.0 Fax Modem

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

4.3-inch Back-Up Camera

How To Use A Brother Ql700

Microwave Meter. Instruction Manual

Users manual. TCW181B-CM_R1 Page 1

SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / Instruction Manual. Page 1 of 9

2 TM. Users Manual. SEC100, SEC200 USB Media Alert

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Action Camcorder Rollei Youngstar USER MANUAL

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

Mold Alert... Operation Manual P0270

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

COMPLETE MANUAL. Version: Optic. September 2015 (English), version 1.0. EnergyOT Optic Developed and Manufactured by Genoa Spark, lda Made in Portugal

4-Port Pocket. USB KVM Switch with USB 2.0 Hub

Infrarot-Bewegungsmelder IP44

reflecta Super 8 Scanner

MINIRIGR. portable rechargeable bluetooth speaker. mrbt user s Guide

For installation guide see reverse of book

Transcription:

HOFFRICHTER DATA box Operating Instructions

Serial Number Each HOFFRICHTER device is provided with a serial number which guarantees the product can be traced back. The serial number is on the type identification plate to be found on the reverse of the device. In case of any query or complaint, please always state the serial number. Conformity The device complies with the requirements of the directives 93/42/EWG. 2 DATA box

Contents Contents Legend of Symbols...................................................4 Safety instructions....................................................5 Intended Use........................................................8 Description of the Device.............................................10 Function of the Device................................................11 Cleaning and Disinfection.............................................17 Technical Data......................................................18 DATA box 3

Legend of Symbols Legend of Symbols: Please observe the Documents Please observe the Operating Instructions Manufacturer CE-declaration of conformity Do not dispose of the device with normal domestic waste. For information on the proper disposal of the device, please contact your responsible customer service. SD-Card slot 4 DATA box

Safety Instructions Before first use of your DATA box, please read this manual thoroughly. Keep the manual in a safe place, so that you will be able to consult it whenever necessary. For the period stipulated by law, HOFF- RICHTER GmbH warrants that the product is free from any defects provided it is used as intended. Attention! HOFFRICHTER GmbH shall not be held liable for any damages or consequential damages, consequences for safety, reliability and performance of the device in case of: Tampering, modifying, adding expansion features, adjustment, repair and maintenance executed by persons who have not been authorized by HOFFRICHTER. Building in accessory and spare parts which have been fabricated by other manufactures and not been released by HOFFRICHTER for use in the DATA box. DATA box 5

Safety Instructions Always have the Operating Instruction ready at hand. It is part of DATA box and a requirement for intended use. The manufacturer shall consider himself responsible for the safety, reliability and operability of the system only if: the device is used in accordance with the Operating Instructions. installation, repair, maintenance and modification work is only carried out by persons authorized to do so. the regulations for quality assurance and traceability are adhered to. The housing of the device does not provide any protection against ingress of water. Never try to open the housing of DATA box. Never expose the device to rain, moisture or humidity. Malfunctions, damage and electric shocks can occure as a result. Never place the DATA box in the vicinity of other equipment or devices, such as defibrillators, diathermy equipment, mobile phones, microwave equipment, remote controlled toys, etc. 6 DATA box

Safety Instructions If temperatures fall below 5 C or rise above + 40 C, proper functioning of DATA box may be impaired. The system must not be exposed to direct solar radiation. Do not use the device if there is visible damage to it. Accidents, fires and electric shocks can occure as a result. DATA box 7

Intended Use The DATA box is an accessory device which can be used in connection with the respiratory therapy series TREND II, VECTOR et, CARAT et and point. It contains a removable memory card and serves to summarise and store the independent transfer of device and therapy data. Exchange of data between patient and medical personnel The memory card can be sent to the sleep laboratory or doctor in charge by the patient, independent of the therapy device. After successful data assessment by medical personnel, the e.g. modified therapy parameters can be copied on the memory card with the help of the DATA box and finally send to the patient again. This data can be sent directly via the DATA box and transferred again to the therapy device. 8 DATA box

Intended Use Summary and storage of additional data If the DATA box is connected to the respiratory therapy device, summary and storage of the additional data is possible in the device by default. Oxygen saturation of the patient can be recorded and stored by a connection with a pulse oxymeter. This enables the medical personnel to analyse the success of the therapy. DATA box 9

Discription of the Device 2 3 Port: CPAP Port: PC 5 4 3 2 1 9 8 7 6 Port: SpO2 5 1 RJ 11 plug socket for the connection to the therapy device (Port: CPAP) 2 LED (green - red) 3 USB plug socket Type B for the connection with a PC (Port: PC) 4 4 SD-Card slot 5 Optional SubD 9-plug socket for a Pulse Oxymeter 10 DATA box

Function of the Device Connect the DATA box with the therapy device. Use the accompanying interface cable for this. The device automatically starts the communication with the therapy device as soon as the devices are connected and an SD card is inserted into the card slot. First, check the device and see whether the file with new therapy or patient data is located on the SD card. If this is the case, the new settings will be transferred onto the therapy device. The memory content of the therapy device will subsequently be stored on the SD card. The LED flashes green in order to display the storage process. The LED illuminates green constantly after completion of the storage. If you do not want to use the device for storing further therapy data during therapy, separate it from the therapy device. When using DATA box to record further therapy data and perhaps oxymetry data, the DATA box must be connected by the interface cable which is connected to the therapy device during the complete therapy. The LED is illuminated green during therapy and a short, periodic blinking of the LED signals storage processes onto the SD card. After completion of therapy, the therapy memory on the device is read and stored. The process can take several minutes depending on the size of the memory. The following table displays the recorded data. DATA box 11

Function of the Device Device VECTOR et CPAP CARAT et CPAP TREND II CPAP VECTOR et Auto CARAT et Auto TREND II Auto VECTOR et Bilevel /ST20 CARAT et Bilevel /ST20 TREND II Bilevel/ST20 point 12 Mode (adjusted) CPAP FLEXLINE CPAP/Auto FLEXLINE all Modes CPAP Central Apnea Obstructive Apnea Mixed Apnea Hypopnea Airway Constriction Snoring Mode Adjustment Leakage Hyperventilation Mouth Exhalation Basic Pressure Pressure Breathing Flow Average System Flow Rel. Respiratory Volume Oxygen Pulse DATA box allways available only available, if DATA box is connected available, if DATA box is used together with Oxygen-Kit

Function of the Device Do not separate the DATA box during therapy and storage of data (displayed by blinking green LED) from the therapy device. Display of the LED The LED signals the following operational conditions: Illuminated green device is operational Blinking green data exchange between devices Blinking red Illuminated red Illuminated orange An error has occurred (see chart from page 14) DATA box 13

Function of the Device Problem Possible Cause Remedy LED illuminates orange SD card not recognised Repeat process several times if necessary. Wait 5 seconds after inserting the SD card. If no change occurs: exchange DATA box LED blinks red first and then illuminates red Data storage error has occurred Error in communication with the therapeutic device has occurred Use another SD card Check the cable connections 14 DATA box

Function of the Device Problem Possible Cause Remedy LED blinks red Error in data program storage Replace DATA box detected An unsupported therapy device has been connected Incorrectly formatted SD card recognised Therapy device has no serial number. A clear allocation of the data is not guaranteed Connect only the therapy devices mentioned on page 8 Format SD card with TRENDset Have a serial number programmed by service technician DATA box 15

Function of the Device SD card Only use SD cards with a storage capacity of at least 128 MB and at most 2 GB. A new SD card must be formatted by the TRENDset software before it can be used. SD cards which are not supported by the DATA box will be distinguished by a blinking red LED. The card holder is a Push-Push-holder and therefore the card is ejected again little by little by putting pressure on the card slot in the direction of the card. When inserting the card, a click signals the maximum slot position. False insertion of the card is prevented by the design and customised intake. Optional pulse oxymeter The optional installation of a pulse oxymeter for recording and storage of oxygen saturation and pulse enables a further analysis of therapeutic devices by the attending medical personnel. 16 DATA box

Cleaning and Disinfection Safety instructions: - Do not use any volatile substances, such as solvents, to aviod damaging of the surface. Clean the device only using a soft, dry cloth. - Do not immerse the device in water or solvent - Make sure that no water or other fluids can penetrate into the device trough opening or venting slots. This could lead to short circuits, damage, electric shocks and fires. Device surface Use a cloth moistened with soap water to clean the external surfaces of the device. Then wipe the device with clear water to remove residual cleaning agent. The devices surfaces should be disinfected at regular intervals and in case of suspected contamination. We recomend SAGROTAN Med for disinfecting the external surfaces of the device. Disinfectants which are recognized according to the RKI Guideline can also be used. Before being put into operation, the device should be completely dry. DATA box 17

Techncal Data Specifications and Performance Dimensions: 115 x 84 x 25 mm Weight: 110 g Operating conditions Operating temperature: + 5 C to + 40 C Relative air humidity: 10 % to 95 % Storage conditions - 40 C to + 70 C (Store in a dry, vibration free position; store device and accessories in their original packaging) Data subject to technical modification 18 DATA box

Notes DATA box 19

Manufacturer: HOFFRICHTER GmbH Mettenheimer Straße 12/14 19061 Schwerin Tel.: +49-385-39925-0 Fax: +49-385-39925-25 Mail: info@hoffrichter.de URL: www.hoffrichter.de DATAbox-eng-1208-01