EVIDENCE BASED MEDICINE. Contours PHP



Similar documents
MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW

Technique Guide. Large Fragment LCP Instrument and Implant Set. Part of the Synthes locking compression plate (LCP) system.

NCB Distal Femur System. Surgical Technique

PERIPROSTHETIC IMPLANTS

Zimmer Periarticular Proximal Tibial Locking Plate

Zimmer Small Fragment Universal Locking System. Surgical Technique

NCB Proximal Humerus System. Surgical Technique

TriLock 1.5 Implants for the Phalanges

Technique Guide. 3.5 mm and 4.5 mm Curved Locking Compression Plates (LCP). For minimally invasive osteosynthesis.

How To Fix A Radial Head Plate

Aesculap Veterinary Orthopaedics. Targon VET Interlocking Nail

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

ACTIV ANKLE DISTAL AND DIAPHYSEAL FIBULA INNOVATION MEANS MOTION

Zimmer Periarticular Elbow Locking Plate System

Surgical technique. End Cap for TEN. For axial stabilization and simultaneous protection of soft tissue.

Technique Guide. 4.5 mm LCP Proximal Femur Plates. Part of the Synthes Periarticular LCP Plating System.

NCB Periprosthetic Femur Plate System. Surgical Technique

Cable System. For Orthopaedic Trauma Surgery.

Technique Guide. 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System. Part of the Synthes variable angle locking compression plate (VA-LCP) system.

VariAx Distal Radius Locking Plate System. Anatomical & Universal Volar Plates Dorsal Plates Fragment Specific Plates

Technique Guide. DHS/DCS Dynamic Hip and Condylar Screw System. Designed to provide stable internal fixation.

DARCO MRS. Locked Plating System for Reconstructive Rearfoot Surgery

SALVATION. Fusion Bolts and Beams SURGICAL TECHNIQUE

ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery.

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

ICUC One-Page Paper. Mixing a lag screw with a splinting protection plate Alberto Fernández Dell Oca, Pietro Regazzoni, Stephan Perren May 2016

Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

Implant Extraction Guide Module One & Two

Elbow System 2.0, 2.8

The information contained in this document is intended for healthcare professionals only.

Scaphoid Non-union. Dr. Mandel Dr. Gyomorey. May 3 rd 2006

OptiLock Periarticular Plating System For Proximal Tibial Fractures. Pre-Launch Surgical Technique

LCP Olecranon Plate. The anatomical fixation system with angular stability for olecranon and proximal ulnar fractures.

LCP Compact Foot/Compact Hand.

Wrist and Hand. Patient Information Guide to Bone Fracture, Bone Reconstruction and Bone Fusion: Fractures of the Wrist and Hand: Carpal bones

Adult Forearm Fractures

CLAW II. Polyaxial Compression Plating System SURGIC A L T ECHNIQUE

TransFx External Fixation System Large and Intermediate Surgical Technique

Technique Guide. 2.4 mm LCP Distal Radius System. A comprehensive plating system to address a variety of fracture patterns.

Malleolar fractures Anna Ekman, Lena Brauer

Achilles Tendon Repair, Operative Technique

MatrixNEURO CMF Matrix

DHS/DCS System. Including LCP DHS and DHS Blade.

Technique Guide. Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.

Knotilus TM. Anchor Instability Repair. Technique Guide

V-TEK IVP System 2.7 System 4.0

FEMORAL NECK FRACTURE FOLLOWING TOTAL KNEE REPLACEMENT

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

Foot Surgery Innovation in Forefoot Reconstruction BAROUK SCREW FRS SCREW TWISTOFF SCREW MEMORY STAPLE VARISATION STAPLE

How To Use A Phoenix Retrograde Femoral Nail

Zimmer Natural Nail System. Cephalomedullary Nail Surgical Technique STANDARD

NARROW DIAMETER implant

INJURIES OF THE HAND AND WRIST By Derya Dincer, M.D.

Titanium Wire with Barb and Needle. For canthal tendon procedures.

Minimally Invasive Lumbar Fusion

INTRODUCTION Cerclage Cable Vs. Monofilament Wire

4052 Slimplicity Tech final_layout 1 6/29/15 3:29 PM Page 2 Surgical Technique

The Right Choice. Exeter. total hip system

Restoration Modular Cone Body/Conical Distal Stem Femoral Components Using the Restoration Modular Instrument System Surgical Technique

EMPLOYMENT: PEACHTREE ORTHOPAEDIC CLINIC ATLANTA- GA PRESENT Orthopaedic Surgeon Northside Hospital, Atlanta, GA

Expert TN. Tibial Nail.

Posterior Referencing. Surgical Technique

Mini TightRope CMC Surgical Technique

BONE PRESERVATION STEM

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.

Regular C/X Prosthetics. Prosthetics

ANTERIOR CERVICAL DISCECTOMY AND FUSION. Basic Anatomical Landmarks: Anterior Cervical Spine

TFN Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

MatrixNEURO. The next generation cranial plating system.

ASOP Exams PO Box 7440 Seminole, FL The Manual of Fracture Casting & Bracing Exam 80% Passing ID # Name Title. Address. City State Zip.

TABLE OF CONTENTS. Indications and Contraindications 3. Features and Benefits 4. Ease of connection 4 Stable fixation concept 5

Expert LFN. Lateral Femoral Nail.

Technique Guide. VersiTomic. Michael A. Rauh, MD. Anterior Cruciate Ligament Reconstruction

Chapter 6 Machining Center Carbide Insert Fundamentals

Implant materials. Learning outcomes. Implant materials in trauma. How to use this handout? Functions of implants. Types of materials

Curriculum Vitae Curtis R. Noel, MD

Scaphoid Fracture of the Wrist

Fixing Dental Implant Component Failure and Fracture: Retrieving the Fractured Implant Abutment Screw. Charles A. Mastrovich, DDS

The new wide Ponto implant design clinical and surgical aspects

Restoration Modular. Revision Hip System Surgical Protocol

Minimally Invasive Hip Replacement through the Direct Lateral Approach

Reaction Torque Sensor

Solid shape molding is not desired in injection molding due to following reasons.

Exeter. Surgical Technique. V40 Stem Cement-in-Cement. Orthopaedics

DELTA PT. Calculable Extra Performance

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Management of common upper limb fractures in Adults and Children. Dr Matthew Sherlock Shoulder and Elbow Orthopaedic Surgeon

Commonly Missed Fractures in the Emergency Department

.org. Ankle Fractures (Broken Ankle) Anatomy

Wrist Fractures. Wrist Defined: Carpal Bones Distal Radius Distal Ulna

Luigi Vito Stefanelli,D.Eng.,DDS

Dental Implant Options in Atrophic Jaws

Arthroscopic Shoulder Instability Repair Using the SUTUREFIX ULTRA Suture Anchor and SUTUREFIX ULTRA Instrumentation System

MODEL T10023 ACCESSORY KIT #1 FOR T10010/T10097 WET GRINDER

DIAGNOSING SCAPHOID FRACTURES. Anthony Hewitt

Structural Integrity Analysis

Surgical technique. Sagitta EVL

Transcription:

EVIDENCE BASED MEDICINE Contours PHP

Orthofix approach to Evidence Based Medicine For years, clinical decision-making was based primarily on physician knowledge and expert opinion. Now, the medical community is searching for measurable outcomes validating efficacy of treatments. Evidence Based Medicine (EBM) is an approach that integrates individual clinical expertise with the best available evidence when making decisions about patient treatment. (Nierengarten MB et al. Using Evidence Based Medicine in Orthopaedic Clinical Practice: The Why, When, and How-To Approach. Medscape Orthopaedics & Sports Medicine. 2001; 5[1]). Over the last few years, there has been a significant growth in Evidence Based Medicine. To receive a digital copy of this Voice of Design, please submit your request to: CLINICAL AFFAIRS DEPT: Email: clinicalaffairs@orthofix.it Phone: +39 045 6719000 To receive a digital copy of the Operative technique, please submit your request to: CUSTOMER CARE: Email: customercare@orthofix.it Phone: +39 045 6719000

INDEX Contours PHP: Summary I 1.0 Introduction 1 2.0 System Components 1 2.1 The Plate 1 2.2 The Main Locking Screw 6 2.3 The Fine Threaded Screws 8 2.4 The Diaphyseal Screws 11 2.5 The Revision Screws 11 3.0 The Contours PHP System 12 3.1 Stability 12 3.2 Minimal Invasiveness 13 3.3 Low Plate Positioning 14 3.4 Easy Application and Removal 14 3.5 Biomechanical Tests 14 4.0 Conclusions 17 5.0 References 17

Contours PHP: Summary Main Locking Screw (page 6) Cannulated conical screw for load transfer to the diaphysis Anti-migration collar Fine thread Self-drilling tip Fine Threaded Screws (page 8) ±15 free angulation for fragments capture and stabilization Automatic breakaway Hexagonal head for easy removal Fine thread designed to improve osteointegration Self-drilling tip Diaphyseal Screws (page 11) Permit to feel screw stability and purchase in the bone Plate (page 2) Right and left designs Anatomical shape Limited contact distal profile Large suture holes Main Locking Screw hole with cam Revision Screws (page 11) For poor quality bone Features Triangular configuration (of the Main Locking Screw and the Fine Threaded Screws) Designed to reduce the amount of bone stock removed from the humeral head Low head profile designed to avoid impingement Anatomically shaped: designed both for the right and the left humerus Made of Titanium Alloy Suture holes with large groove designed for easy needle insertion I

1. Introduction The Contours PHP-Proximal Humeral Plate is a locking titanium plate intended for the treatment of fractures, osteotomies and non-unions of the proximal humerus, particurarly in osteopenic bone. This document gives a comprehensive description of Contours PHP s technical and biomechanical features. The innovative technical aspects of the components and the whole system are presented, thus demonstrating the unique advantages and benefits that Contours PHP offers. 2. System Components 2.1 The Plate 2.1.1 Right and left designs The plate is available in two different anatomically shaped designs for the right and left humerus (Fig. 2). Fig. 1 Plate dimensions Fig. 2 Plate: right and left designs 1

2.1.2 Plate features B) Structural part D) Bevelled distal tip A) Anatomic shape C) Limited contact distal profile Fig. 3 Plate main features A) The anatomic shape The proximal part of the plate is characterized by an anatomic shape. Obtaining a correct anatomic reduction has an influence on the final clinical result [1] and can reduce the risk of complications [2]. B) The structural part The structural part locked with the main locking screw provides frontal stability by allowing the load transfer from the head to the diaphysis of the humerus. C) The limited contact distal profile Impairment of periosteal blood supply due to plate fixation can induce formation of cortical porosis that increases the risk of poor fracture healing and refracture after plate removal [3]. Reducing the contact area between plate and bone provides reduced disturbance of blood supply [4]. The Contours PHP has been designed with a limited contact distal profile to permit correct periosteal vascularization to decrease the risk of cortical porosis. 2

D) The bevelled distal tip In the treatment of proximal humerus fractures careful soft tissue management is considered a predictor of success [5]. The distal part of the plate has been designed with a bevelled tip with the aim of facilitating plate insertion under the soft tissues. 2.1.3 Plate holes B) Threaded holes for Fine Threaded Screws A) Suture holes A) Suture holes C) Plate Holder hole E) Main Locking Screw hole D) Temporary fixation holes F) Elongated holes for Diaphyseal Screws G) Distal Diaphyseal Screw hole Fig. 4 Frontal view of the plate 3

A) The suture holes Use of additional sutures has been suggested to reduce and fix the tuberosities in osteoporotic bone [6]. The 4 oblong suture holes are connected to large grooves on the reverse side of the plate which permit easy passing of the suture needle. This design feature has been implemented to facilitate suturing and cerclage procedures. B) The threaded holes for Fine Threaded Screws The plate is supplied with threaded holes for locking of Fine Threaded Screws. C) The Plate Holder hole The plate has a threaded hole for the Plate Holder that is used during the plate application. D) The temporary fixation holes Prior to definitive fixation, the plate is temporarily fixed by using K-wires that prevent sliding and detaching of the plate. K-wires are also used to keep the fracture reduced during the application of the plate. 4

E) The Main Locking Screw hole The hole for the Main Locking Screw has a cam* which securely locks the Main Locking Screw. The cam is an alternative to a threaded hole: the main screw is locked tightly to the plate, so that the plate and screw result in a unique piece. Cold welding of the locking titanium screws in the threaded plate holes is a well-known problem that can occur at the time of screw tightening and can significantly complicate subsequent plate removal [7]. Because of its specific closure mechanism, the use of a cam avoids titanium cold welding. F) The elongated holes for Diaphyseal Screws Proper plate placement is considered fundamental to treat successfully proximal humerus fractures [1, 5]. The elongated holes for Diaphyseal Screws permit plate fine tuning on the longitudinal axis to get its optimal positioning. These holes are also used for Revision Screws in case of osteoporotic bone. *Cam = A mechanical device for converting a rotating motion into a locking motion; specifically, after that the screw in inserted, the cam is rotated into a locking position, fixing the screw firmly into the plate. 5

2.2 The Main Locking Screw B) Anti-migration collar Ø 6mm C) Part in contact with the cam L L ranges from 40mm to 60mm with 5mm increments D) Conical shape E) Fine thread profile Ø 5,6mm A) Cannulated screw F) Self-drilling tip Fig. 5 Main Locking Screw dimensions Fig. 6 Main Locking Screw features A) Cannulated screw The Main Locking Screw is cannulated to allow a guidewire to be run through. This feature helps to put the screw into position. The Main Locking Screw, working as a hip screw, transfers the primary load from the head to the diaphysis of the humerus. B) The anti-migration collar With angle-stable plate systems screw migration leading to perforation of the humeral head and reoperation is a common complication [1, 6, 2]. The Main Locking Screw has been created with an anti-migration collar. During the insertion, when the screw is completely inserted, the screwdriver is automatically released. C) The part in contact with the cam The Main Locking Screw has a smooth cylidrical part which locks to the cam without cold welding. 6

D) The conical shape The diameter of the thread increases from 5,6mm to 6mm. The conical shape is designed to produce radial preload* with the following mechanism: as the screw is inserted, the thinner distal end makes the initial path through the bone. As the screw advances, its diameter increases exerting radial pressure* on the near cortex. This is designed to improve the holding power of the screw. F) The self-drilling tip The tip of the screw and the cutting angles have been optimized to provide easy entry and stable contact between the screw and the bone surface. The flutes have been designed to offer efficient cutting and removal of the bone chips. *Radial preload = a compressive force perpendicular to the screw axis produced during the insertion of the screw *Radial pressure = pressure perpendicular to the screw axis 7

2.3 The Fine Threaded Screws A) Rapid insertion B) Breakaway groove 120 mm L = 8 lengths from 20mm to 55mm with 5mm increments C) Hexagonal head with spheric profile D) Conical shape E) Fine thread Ø 3,3mm Ø 2,2mm L+3mm F) Self-drilling tip Fig. 7 Fine Threaded Screw dimensions Fig. 8 Fine Threaded Screw features A) Rapid insertion The Fine Threaded Screws are rapidly inserted with the use of a power drill. Differently from other systems on the market, in which screw insertion has to be done with a screwdriver, this solution has been conceived to reduce the time needed for screw application. 8

B) The breakaway groove The groove has been designed with a particular geometry to permit the automatic breakaway of the shank from the screw implanted in the bone. The breakage occurs at a defined closure torque* [internal reports]. C) The hexagonal head with spheric profile Screw Axis The particular hexagonal head with spheric profile of the Fine Threaded Screws is designed to allow the screw removal even if the screwdriver and the screw head are not coaxial*. The screw head remains external; therefore, it can be easily seen, cleaned from the newly formed bone and grabbed. In addition, since the screw head has an external 3,5mm hexagon, it allows an easy grabbing with pliers or similar instruments. Screwdriver Axis D) The conical shape The conical part of the Fine Threaded Screws has a larger diameter than the hole diameter in the plate; therefore, it generates a lateral pressure on the plate. This has been designed to provide an optimal grip with the hole and to reduce the risk of screw backing out, a complication that can be frequently seen with other systems [11]. In addition, the conical shape guarantees the coupling between the screw thread and the hole thread also when screws are oriented up to ±15. *Closure torque = force required to fasten a screw *Coaxial = having a common axis 9

E) The fine thread and osteointegration The Fine Threaded Screws are characterized by: Fine thread pitch and low thread profile: The low thread together with the fine thread pitch provide attenuates stripping effect during insertion an increase in the screw-bone contact interface. This improves fixation, holding power and osteointegration [9, 10, 12]. F) The self-drilling tip The three cutting edges and the small diameter of the screw make the tip self-drilling. The Fine Threaded Screws have greater mechanical efficiency and significantly better holding power compared to other commercial cortical screws, furthermore, titanium surface encourages osteointegration of bone screws [10, 12, 13]. 10

2.4 The Diaphyseal Screws LT [mm] 8 available lengths from 22mm to 36mm with 2mm increments Ø 4,5mm Features: 3,5mm hexagon Spherical head Non locking screw to feel screw stability and gripping into the bone 2.5 The Revision Screws LT [mm] 5 available lengths from 26mm to 34mm with 2mm increments Ø 6,5mm Features: 3,5mm hexagon Spherical head Wider crests for poor quality bone Non locking screw to feel screw stability and gripping into the bone 11

3. The Contours PHP System The Contours PHP was designed to have the following features: Triangular configuration (of the Main Locking Screw and the Fine Threaded Screws) Designed to reduce the amount of bone stock removed from the humeral head Low head profile designed to avoid impingement Anatomically shaped: designed both for the right and the left humerus Made of Titanium Alloy Suture holes with large groove designed for easy needle insertion 3.1 Stability With Contours PHP, stability is obtained with the triangular configuration of the Main Locking Screw and the angulated Fine Threaded Screws. Principal stabilization is achieved by the Main Locking Screw, which is inserted in the calcar area. By providing mechanical support of the inferomedial region of the proximal humerus head, characterized by maximum bone quality and quantity [14], the risk of secondary loss of reduction and screw fixation failure is reduced [15]. The Fine Threaded Screws angulated in convergent directions up to ±15 contribute to pullout strength and fixation strength. Although characterized by a diameter of 2,2mm, they are as stable as Ø 3,5mm screws as described by [16] (Fig. 9). 12

Holding power (pullout resistance) Ø 4 mm * Ø 3,5 mm ** Ø 3,5 mm * Ø 2,2 mm *** Contours PHP Design (*) predrilled and pretapped (**) predrilled and self-tapping (***) self-drilling and self-tapping Ø1,6 mm *** Ø 1,2mm *** Screw type and diameter Fig. 9 Holding power of different screws. Adapted from [15]. There is no significant difference between the maximum holding power of the 2,2mm fine machine thread screws and the 3,5mm cortical screws. 3.2 Reduced amount of metal content Avascular necrosis is initiated by the fracture pattern, that almost unavoidably damages the delicate blood supply of the humeral head [17]. Contours PHP has been designed to decrease the invasiveness in terms of metallic content in the humeral head and reduce further damages of the vascularity. Normalized volume of removed bone Contours PHP + 69% Competitor 1 + 247 % Competitor 2 Fig. 10 Relative amount of removed bone With the Contours PHP the amount of bone removed from the humeral head is lower in comparison to other systems in the market. 13

3.3 Low Plate Positioning Low head profile and low plate positioning have been conceived to reduce the risk of subacromial impingement, which frequently occurs when plates are not low contoured or placed too superiorly [18, 19]. In addition, lower plate positioning allows the use of anatomical landmarks (e.g., insertion of the pectoralis major muscle) located far from the fracture zone. 3.4 Easy Application and Removal Contours PHP has been developed to be easy to apply and remove. Removal of titanium angle-stable plates can be troublesome. The main problems are generally related to the removal of the screws anchored in the bone [20, 21, 22]. To remove Contours PHP only two instruments are necessary: a standard 3,5mm hexagonal screwdriver for the main locking screw and distal screws and a 3,5mm quick connect screwdriver for the fine threaded screws. The hexagonal head of the Fine Threaded Screws and the cam facilitate plate removal. 3.5 Biomechanical Tests A series of biomechanical tests has been performed in an external certified laboratory to compare the mechanical behaviour of the Contours PHP with its main competitor. The following tests were performed: Torsion test Flexion test The results demonstrate that the Contours PHP has similar torsional and superior bending biomechanical characteristics to its main competitor. 14

3.5.1 Torsion test Aim of the test: Comparison of the torsional stiffness between the Contours PHP and its main competitor. Set-up: The plates were mounted as shown in Fig. 11 and tested according to [23, 24]. Torsional stiffness was evaluated by measuring the angular excursion of the system (plate + sawbones) subjected to a symmetrical torque for 1000 cycles. The bigger the angle, the lower the torsional stiffness. Solid Rigid polyurethane Rigid Polyurethane foam 12.5 Foam pcf 12.5 representing pcf (Sawbones ) human osteoporotic representing human cancellous bone osteoporotic cancellous bone Polysulfone representing cortical bone F Fig. 11 Scheme of the tested specimens Torsion Test Results: Delta Angle PHP plate Main Competitor Screw migration did not occur; Contours PHP showed a constant total angular excursion, which indicates a good torsional stiffness. The results show that the Contours PHP consisting of 1 Main Locking Screw, 3 Diaphyseal Screws and 4 Fine Threaded Screws is characterized by a torsional performance comparable to its main competitor (Fig. 12). Fig. 12 Mean total angular excursion The difference between the two plates is not significant. 15

3.5.2 Flexion test Aim of the test: Comparison of the bending stiffness between the Contours PHP and its main competitor. Set-up: The plates were mounted as shown in Fig. 13 and tested according to [25]. A load was applied for 5000 cycles. The displacement of the system (plate + sawbones) was measured at every cycle. Solid Rigid polyurethane Rigid Polyurethane foam 12.5 Foam pcf 12.5 representing pcf (Sawbones ) representing human osteoporotic human osteoporotic cancellous cancellous bone bone Polysulfone representing cortical bone F Fig. 13 Scheme of the tested specimens Flexion Test Results: Delta Displacement PHP plate Test failure at 500 cycles Main Competitor The competitor plate showed low bending stiffness and failed. On the contrary, the Contours PHP showed higher bending stiffness. The results indicate that in comparison to the competitor plate the Contours PHP is able to resist to higher loads (Fig. 14). Fig. 14 Mean displacement The competitor plate failed during the test 16

4. Conclusions This document was created to present the technical and biomechanical features of the Contours PHP system. The technical solutions studied for this system were designed to solve typical problems that can occur during angle-stable plate fixation. Biomechanical tests prove that Contours PHP performance is comparable to or better than the market leader plate performance. In conclusion, Contours PHP is a unique innovative system for the treatment of acute fractures of the proximal humerus. 5. References 1. Clavert P, Adam P, Bevort A, Bonnomet F, Kempf JF. Pitfalls and complications with locking plate for proximal humerus fracture. J Shoulder Elbow Surg. 2010 Jun;19(4):489-94. Epub 2009 Dec 7. 2. Bigorre N, Talha A, Cronier P, Hubert L, Toulemonde JL, Massin P. A prospective study of a new locking plate for proximal humeral fracture. Injury. 2009 Feb;40(2):192-6. Epub 2008 Dec 13. 3. Klaue K, Fengels I, Perren SM. Long-term effects of plate osteosynthesis: comparison of four different plates. Injury. 2000 May;31 Suppl 2:S-B51-62. 4. Perren SM, Cordey J, Rahn BA, Gautier E, Schneider E. Early temporary porosis of bone induced by internal fixation implants. A reaction to necrosis, not to stress protection? Clin Orthop Relat Res. 1988 Jul;(232):139-51. 5. Fjalestad T, Hole MØ, Hovden IA, Blücher J, Strømsøe K. Surgical treatment with an angular stable plate for complex displaced proximal humeral fractures in elderly patients: a randomized controlled trial. J Orthop Trauma. 2012 Feb;26(2):98-106. 6. Helwig P, Bahrs C, Epple B, Oehm J, Eingartner C, Weise K. Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus? A prospective series of 87 patients. Acta Orthop. 2009 Feb;80(1):92-6. 7. Suzuki T, Smith WR, Stahel PF, Morgan SJ, Baron AJ, Hak DJ. Technical problems and complications in the removal of the less invasive stabilization system. J Orthop Trauma. 2010 Jun;24(6):369-73. 8. Brunner F, Sommer C, Bahrs C, Heuwinkel R, Hafner C, Rillmann P, Kohut G, Ekelund A, Muller M, Audigé L, Babst R. Open reduction and internal fixation of proximal humerus fractures using a proximal humeral locked plate: a prospective multicenter analysis. J Orthop Trauma. 2009 Mar;23(3):163-72. 9. Asnis, S E, Ernberg J J, Bostrom M P G, Wright T M, Harrington R M, Tencer A, Peterson M. Cancellous Bone Screw Thread Design and Holding Power. Journal of Orthopaedic Trauma. Volume 10(7) 1996 pp 462-469 10. Lawes TJ and Goodship AE. Biological response to fine pitch and hydroxyapatite coated bone pins. Internal report 11. Charalambous CP, Siddique I, Valluripalli K, Kovacevic M, Panose P, Srinivasan M, Marynissen H. Proximal humeral internal locking system (PHILOS) for the treatment of proximal humeral fractures. Arch Orthop Trauma Surg. 2007 Apr;127(3):205-10. Epub 2006 Dec 22. 17

12. Gausepohl T, Möhring R, Pennig D, Koebke J. Fine thread versus coarse thread. A comparison of the maximum holding power. Injury 32 2001 13. Moroni A, Toksvig-Larsen S, Maltarello MC, Orienti L, Stea S and Giannini S A Comparison of Hydroxyapatite- Coated, Titanium-Coated, and Uncoated Tapered External-Fixation Pins. An in Vivo Study in Sheep J Bone Joint Surg Am, 1998 Apr 01;80(4):547-54 14. Hepp P and Josten C. Biology and biomechanics in osteosynthesis of proximal humerus fractures. Eur J Trauma Emerg Surg. 2007 N.4 15. Gardner MJ, Weil Y, Barker JU, Kelly BT, Helfet DL, Lorich DG. The importance of medial support in locked plating of proximal humerus fractures. J Orthop Trauma. 2007 Mar;21(3):185-91. 16. Gausepohl T, Möhring R, Pennig D, Koebke J. Fine thread versus coarse thread. A comparison of the maximum holding power. Injury. 2001 Dec;32 Suppl 4:SD1-7. 17. Karataglis D, Stavridis SI, Petsatodis G, Papadopoulos P, Christodoulou A. New trends in fixation of proximal humeral fractures: a review. Injury. 2011 Apr;42(4):330-8. Review 18. Duralde XA, Leddy LR. The results of ORIF of displaced unstable proximal humeral fractures using a locking plate. J Shoulder Elbow Surg. 2010 Jun;19(4):480-8. Epub 2009 Dec 5. 19. Geiger EV, Maier M, Kelm A, Wutzler S, Seebach C, Marzi I. Functional outcome and complications following PHILOS plate fixation in proximal humeral fractures. Acta Orthop Traumatol Turc. 2010;44(1):1-6.20. 20. Lehmen J A, Della Rocca G J, Murtha Y M, Crist B D. Removal technique for cold-welded titanium locking screws. Injury, Int. J. Care Injured 42 (2011) 1377 1379 21. Georgiadis G M, Gove N K, Smith A D, Rodway I P. Removal of the Less Invasive Stabilization System. J Orthop Trauma 2004;18:562 564 22. Suzuki T, Smith W R, Stahel P F, Morgan S J, Baron A J, Hak D J. Technical Problems and Complications in the Removal of the Less Invasive Stabilization System. J Orthop Trauma 2010;24:369 373 23. Kralinger F, Gschwentner M, Wambacher M, Smekal V, Haid C. Proximal humeral fractures: what is semi -rigid? Biomechanical properties of semi-rigid implants, a biomechanical cadaver based evaluation. Arch Orthop Trauma Surg. 2008 Feb;128(2):205-10. Epub 2007 Nov 27. 24. Füchtmeier B, May R, Fierlbeck J, Hammer J, Nerlich M. Technol Health Care. A comparative biomechanical analysis of implants for the stabilization of proximal humerus fractures. 2006;14(4-5):261-70. 25. Lill H, Hepp P, Korner J, Kassi JP, Verheyden AP, Josten C, Duda GN. Proximal humeral fractures: how stiff should an implant be? A comparative mechanical study with new implants in human specimens. Arch Orthop Trauma Surg. 2003 Apr;123(2-3):74-81. Epub 2003 Feb 12.

Manufactured by: ORTHOFIX Srl Via Delle Nazioni 9 37012 Bussolengo (Verona) Italy Distributor: Telephone +39-0456719000 Fax +39-0456719380 0123 www.contoursphp.com Voice of Design Contours PHP www.orthofix.com PH-1207-VOD-E0 B 10/12