Operations and Instruction Manual Might Swivel - Part # 310273 Concrete and Steel Anchorage Connector ANSI Z359.1 10,000 lbs / 44kn



Similar documents
VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249

Super Slider ADJUSTABLE FROM Model #HD26229

D-Ring. Fixed Arm. 1.2 LIMITATIONS: The following application limitations must be recognized and considered before using this product:

User Instruction Manual Vertical Lifelines and Vertical Lifeline Subsystems

Wire Rope Extender Lanyard

Operating instructions. 3-in. x 6-ft. Anchor Strap for Skyline Horizontal Lifeline

Horizontal Lifeline. SideWalk Rope. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment

Working at Heights and Fall Protection

WORKING AT HEIGHT & ITS WOES

Product Name: Beamer 2000

Safe Operating Procedure

fall arrest. Contact your distributor or Guardian about policies regarding replacement of Guardian components involved in a fall.

ELEVATED WORK POLICY

Owner s Manual Gantry Cranes

Fall Protection System: A system put in place to protect workers from falling. (i.e. installation of guardrails, fall arrest, fall restraint, etc.

Lanyards. Self Retracting. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment

Fall Protection Guidelines

USER INSTRUCTIONS AND SPECIFICATIONS for use of SAFE APPROACH STANDING SEAM ANCHOR & SAFE APPROACH METAL ROOF SCREW-DOWN ANCHOR

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Introduction to Fall Protection

OSHA Remove impacted systems and components. Inspect systems prior to use.

WARNING! Failure to follow these inspection procedures can cause personal injury and property damage.

ICC-ES Evaluation Report

Elkhorn Construction, Inc. Safety Manual Title: Fall Protection Policy Effective Date:

SPECIAL INSPECTION AND TESTING AGREEMENT INTERNATIONAL BUILDING CODE

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13

SELF-STEERING AXLE TABLE OF CONTENTS

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Policy on Water Heater Installations Policy No. UPC Effective: September 1, 1995 Revised: February 10, 1996

Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions

RZ Guardrail System Installation Manual

Fall Protection Safety Program

FALL PROTECTION- Part 2 SELF INSPECTION CHECKLIST

Frequently Asked Questions

Temporary Horizontal Lifeline System Manual Standard Duty - E8 Model: HLLA38030 and HLLA38060

Fall Protection and Fall Prevention. San José State University Environmental Health and Safety Facilities Development & Operations

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE

Fall Protection Susan Harwood Grant Training Program 2013 Fall Arrest. OSHA Susan Harwood Training - AGC

Oregon Fuel Injection

This material was produced under grant number SH F-48 Occupational Safety and Health Administration, U.S. Department of Labor.

DiscPlus DX195 and DX225 Air Disc Brakes

EMPLOYEE FALL PROTECTION

PART E SPECIFICATIONS

PALLET JACK TON

Fall Protection Program

Float and Thermostatic Traps Series H, C and X

758 Heavy-duty Ratchet Guy Wire Cutter

How To Make A Fall Arrest Anchor System

FALL PROTECTION WORK PLAN

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

CHAPTER 10. FALL PROTECTION PROGRAM

WEEKLY SAFETY MEETING

>PSA-VRS< >PSA INOX STAR< M12 (1 Pers.)

Guide to Fall Protection Regulations

Fall Protection, Title 29 Code of Federal Regulations (CFR) Part 45, Subpart M, Fall Protection, , , , and1926.

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

HYDRAULIC TABLE CART 500-LB.

SITE SPECIFIC FALL PROTECTION PLAN

1000-LB. TRAILER JACK OWNER S MANUAL

Rebuild Instructions for and Transmission

SEAT BELT Installation Manual

What is Fall protection?

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

CHIPPING HAMMERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

I BEAM TRACK INSTALLATION

Department of Environmental Health & Safety. Fall Protection Program

Guidelines for Earthquake Bracing Residential Water Heaters

The Work at Height Safety Association. Guidance on inspecting eyebolts used for personal fall protection purposes

Guidelines for Earthquake Bracing of Residential Water Heaters

OSHA 29 CFR 1926 Subpart M ( ) OSHA 29 CFR 1910 Subparts D,F, I ( , 66, 67, and 132

HUS-H Screw Anchor. Technical data. Seismic design data. HUS-H Carbon steel screw anchor. HUS-H diameter 8, 10, 14. Seismic design data

It should be noted that this revised standard does not address the construction industry, window cleaning belts, and sports-related activities.

jbs nfb INSTALLATION INSTRUCTIONS AND OWNERS MANUAL Mechanical Steering for Inboard, Outboard, and Sterndrive Powered Vessels

Understanding the ANSI Z359 Fall Protection Code

3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form


Submittal Information

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

Sash Replacement Guide

16 April F Dodge Adjustable Track bar with Relocation Bracket 1

Installation and Maintenance Manual for SPANCO Freestanding Modular Bridge Cranes & Monorails

UPLIFT Height Adjustable Standing Desk (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE - - ALSO - - Watch our assembly video

James M. Pleasants Company

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

INSTALLATION INSTRUCTIONS MULTI-MOUNT KIT Part Number: Application: Warn HP PowerPlant P/N 71800

SAFE HANDLING OF PRECAST CONCRETE PRODUCTS

Washer, Electrical Equipment Bond. WEEB Patent Pending INSTALLATION INSTRUCTIONS. For Kinetic Solar K-Rack only

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Health and Safety Resources Caution to Users

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Packaged Terminal Air Conditioner Wall Sleeve Installation

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

Fall protection systems and practices Duty to have fall protection Protection at or above 6' level.

Operation manual. drill rig KERN-DEUDIAM KBS-Series K100

PC-Concrete Injectable Concrete Anchoring and Repair System

Walking and Working Surface Checklist:

BRAKE DRUM AND ROTOR SERVICE INFORMATION

Transcription:

Safety.. Operations and Instruction Manual Might Swivel - Part # 310273 Concrete and Steel Anchorage Connector ANSI Z359.1 10,000 lbs / 44kn Description: Technical: Zinc plated forged heat treated steel, Special design gives the anchor a incredible 10,000 lb ultimate breaking strength 2,000 safe working load Rates for 4 men HLL systems Rotates 360 degrees Flips 180 degrees Used for steel flanges or concrete substrate Hardware for concrete - See page 5 for details. Tensile Strength - 10,000 lbs Material - Drop forged alloy steel Hardware for steel - 5/8 grade 8 bolt, lock washer and nut Working load - 2,000 IMPORTANT!! All persons using this equipment must read and understand all instructions. Failure to do so may result in serious injury or death. If a fall occurs, this anchor must be disposed of according to the manufacturer instruction. Users should be familiar with pertinent regulations governing this equipment. All individuals who use this product must be correctly instructed on how to use this device.

Components Cap Swivel Housing Locking Cap Slots Reinforced Bridge D-Ring Locking Caps Base Plate The MEGA Swivel incorporates a custom design to its components to give it s incredible strength. The D-Ring used a heavy gauge heat treated steel, Reinforced Bridge and Locking Caps. The Locking Caps slot into the Swivel Housing preventing the D-Ring from spreading outwards during heavy loads. The Bridge keeps the D-Ring from collapsing. The Swivel Housing allows the D-Ring to flip back and forth as wells rotate at 360 degrees. 2

APPLICATIONS USE: The MEGA Swivel anchorage connector is designed to use for fall protection, four man life line systems, restraint, work positioning, personal riding, tie back anchors, rescue and military applications. REQUIREMENTS 1. Follow all manufacturer s instructions with this device. Only trained professional personnel should install, maintain, inspect and use this product and its components or other personal protective equipment in conjunction with this product. 2. Do not use this device if its components are damaged, cracked, broken or have any deformation to its structure. Do not use device if it does not operate smoothly or freely. 3. OSHA requires that any personal fall arrest system and all the components in the system be removed from service and destroyed if a fall has occurred loading this device. 4. This product is not designed to be repaired or altered in any way. The unit must be removed from service. 5. Do not use incompatible connectors with this device. Use only self-locking snap hooks or carabiners that meet ANSI 359.1 requirements. Only use connectors that are designed for each application. Ensure that all connectors are fully closed and in the locked position. Connectors strength must meet the 5,000 lb requirement. 6. All personal fall arrest systems must meet all applicable state, federal, city, OSHA and ANSI requirements and any other regulating government body. It is the responsibility of the employer to regulate its worker and make sure all laws are being complied with concerning this device. 7. This anchorage point attachment must be identified by a qualified or competent person by means of support of a worker. For fall arrest, the anchor point must meet the 5,000 lb requirement per single user. It is the responsibility of the user and employer that the I-beam can meet the anchor requirements and the proper anchoring techniques be used with this device. See page 5 for required hardware to use with this device. 8. This anchor point must be used with care. Determining the proper placement of this device must take into consideration that in combination with a lanyard the user will not be allowed to free fall more that 6 feet (1.8 M). Make sure the fall path is clear of obstructions and no swing falls occur. 9. The structure or substrate that this device is anchored to must meet the capabilities of withstanding the 5,000 lb static load capacity per person. (5,000 lbs for one person) (10,000 lbs fro two person) see pages 5-7 for details on anchoring requirements. 10. Pregnant women and minors must not use this product. 11. Designed safe working load is 400 LBS (149.3 kg). Do not exceed this weight. 3

Swing Fall Obstacle - Danger 3 clearance Max fall distance 6 Do not work above anchorage point Anchorage connector Shock absorbing lanyard Work Surface Consider D-ring strength distance and deceleration distances from shock absorbers and make sure you obtain a 3 clearance. Obstruction/Deck/Floor/Ground Swing Fall Swing fall can occur when the worker is not directly under the anchorage point. Avoid a swing fall by working directly underneath your anchorage point. Swing falls can jeopardize the clearance required with retractable, shock absorbing lanyards and other sub-systems of your fall protection system. Avoid swing fall at all circumstances. Swing falls can cause serous injury or death. Danger: avoid swing falls 4

BOLT REQUIREMENTS FOR STEEL Grade 8 markings For steel applications a grade 8 bolt with a locking nut and washer must be used. Bolt Lock washer Lock nut Technical data: Bolt: SAE grade 8 Max. tightening torque 110 ft-lb 2 Minimum length 5/8 diameter 18 thrds/in Nut: SAE grade 8 lock nut 5/8 diameter 18 thrds/in Washer SAE grade 8 lock washer 5/8 diameter Ultimate Breaking Strengths of grade 8 bolt Ultimate Tensile - 18,000 lbs. Ultimate shear - 15,000 lbs. Safe Working Loads Tensile - 2,000 lbs Shear - 2,000 lbs BOLT REQUIREMENTS FOR CONCRETE Custom designed bolt exclusive with this anchor 5 1/2 3/4 The custom bolt supplied with these anchor can be used in 3,000 PSI normal weight concrete. Technical data: Bolt: SAE grade 5 Max. tightening torque 110 ft-lb 5-1/2 length 3/4 diameter 18 thrds/in Expander Nut: SAE grade 5 3/4 diameter 18 thrds/in Washer SAE grade 5 3/4 diameter Ultimate Breaking Strengths Ultimate Tensile - 12,000 lbs. Ultimate shear - 10,000 lbs. Safe Working Loads Tensile - 2,000 lbs Shear - 2,000 lbs 5

DRILLING REQUIREMENTS FOR STEEL Flange must be at least 1/4 thick. Steel 3 Drill the hole 5/8 in diameter The hole must be 3 from an edge or corner. Do not use MEGA Swivel in steel thinner than 1/4 Be aware of your alignment of the lanyard or connectors, make sure they do not run over the edge of the steel flange. Make sure you drill or use a hole so the entire Swivel Plate is resting on the steel flange. 5/8 hole drilled 3 from the edge. DRILLING REQUIREMENTS FOR CONCRETE Drill a 3/4 diameter hole 5 deep. Use recommended drill type and size. Blow hole clean with compressed air. Drill hole straight into substrate. Only use an industrial SDS hammer drill and drill bit. The concrete substrate must be 20 wide and at least 10 thick. Drill hole 5 deep hole drilled straight into substrate. The anchor bolt will penetrate the hole 4 1/2 leaving 1/2 of play at the bottom of hole. Do not drill a hole closer then 10 from any corner. Drill hole straight DO NOT drill hole less then 5 to insure the Swivel Plate can rest firmly on the face of the substrate. If the plate does not rest on the substrate, drill another hole. Make sure hole is drilled straight into the substrate to ensure proper swiveling action. 6

Use tapered washer with I-Beams that have tapered flanges Change drawing Acceptable Loads DANGER - Improper load 7

INSPECTION Inspection: Official periodically inspection must be made at least annually. These inspection must be made by competent persons of official capacity other then the intended users. If server weather or condition exist then inspections must be carried out more frequency. All inspection results must be logged in the inspection and maintenance log on page 8. 1. Inspect unit to make sure it is straight and operates smoothly. 2. Inspect unit to make sure the label is affixed to unit. 3. Inspect unit for damage, crack and wear that could affect the strength or operation. 4. Inspect the anchoring fastener for damage, crack and wear that could affect the strength or operation. 5. Inspect unit to make sure all metal components are not damaged. 6. Make sure unit can rotate and flip flop freely. 7. Record the inspection results in the inspection log on page 8.. Storage and Cleaning: 1. Keep unit free of grease, oils and dirt. Disposal: 1. Dispose of unit after any fall has occurred. 2. Dispose of unit if any damage has occur of any sort. 3. Dispose of unit if it does not operate freely. After inspection reveals damage or unsafe conditions, proper disposal requires the Mega Swivel Anchor to be destroyed or proper disposed. DISPOSAL OSHA and ANSI standards require that if a fall occurs that the entire fall protection system must be removed from service and destroyed. Some components of a system may be allowed to be returned to the manufacture for re-certification, like a( Retractable ). You must follow the instruction listed below for proper the MEGA Swivel Remove from service immediately after a fall occurs. Remove the anchor bolt from the MEGA Swivel and dispose it buy placing the bolt into a small box. Seal box closed then place in the garbage. This will prevent an unsuspecting user to see it in the trash and try to re-use the anchor. Repeat the same steps above to dispose of the MEGA Swivel. Do not put the anchor bolt in the same box as the MEGA Swivel. WARNING: It is the responsibility of the employer, contractor and end user to properly dispose the fall protection systems and report the incident to the appropriate governing body. See your local, state and federal regulations. Re-using any component of a fall protection system after a fall has occurred is Illegal, dangerous and can lead to serous injury or death. 8

Warning: All persons using this equipment must read, understand and follow all instructions. Failure to do so may result in serious injury or death. WARNING DO NOT use in wet or uncured concrete. Use in normal weight concrete with a compression strength at least 3,000 PSI (20.7 MPa) Use for Fall Protection Only MEGA Swivel Steel & Concrete Anchorage Compliance: ANSI Z359.1 10,000 lbs. Part # 310273 / Batch 000 Manufactured 00/00/00 US Patent Pending TM LABELING The following labels must remain affixed to this product 9

INSPECTION AND MAINTAINANCE LOG DATE OF MANUFACTURE: MODEL NUMBER: DATE PURCHASED: Date Pass Fail Corrective Action Name of Inspector Signature www.skyclimber.com PH: 740-203-3931 FX: 740-203-3901 10