Catherine LeCocq, Robert Ruland. February, 2008



Similar documents
THE ALIGNMENT STRATEGY FOR THE SPIRAL2 SUPERCONDUCTING LINAC CRYOMODULES

Types of 3D Scanners and 3D Scanning Technologies.

PRODUCT BROCHURE SF. Shop-Floor Coordinate Measuring Machine

FACET First Beam Commissioning. Jerry Yocky For the FACET commissioning team 21-May-2012 IPAC 2012, New Orleans, LA

Towards large dynamic range beam diagnostics and beam dynamics studies. Pavel Evtushenko

TRIMBLE ATS TOTAL STATION ADVANCED TRACKING SYSTEMS FOR HIGH-PRECISION CONSTRUCTION APPLICATIONS

Mechanical Operation and Maintenance Vacuum Group

Sensor/Raft Metrology Status

THE TESLA TEST FACILITY AS A PROTOTYPE FOR THE GLOBAL ACCELERATOR NETWORK

Introduction. Magnet Coordinate System

Figure 1: Lattice drawing for the APS storage ring.

10 Project Costs and Schedule

TPC laser calibration system

Differentiation of 3D scanners and their positioning method when applied to pipeline integrity

FCC JGU WBS_v0034.xlsm

Slice Emittance Measurements at the SLAC Gun Test Facility*

Industrial Involvement in the Construction of Synchrotron Light Sources

Status Overview The Australian Synchrotron. Steven Banks Control Systems Group

Digital vs. Analogue Control Systems

Projects and R&D activities

Development of High Stability Supports for NSLS-II RF BPMS

Wind Direction Smart Sensor (S-WDA-M003)

PRODUCT BROCHURE SPATIAL ANALYZER. Powerful, traceable and easy-to-use metrology and analysis software

DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements

Special Specification 6033 Computerized Transportation Management System

Integration Services

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

LOCATION DEPENDENCY OF POSITIONING ERROR IN A 3-AXES CNC MILLING MACHINE

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Data-analysis scheme and infrastructure at the X-ray free electron laser facility, SACLA

Industrial Robotics. Training Objective

Somero SiteShape System

Ultraprint 2000 HiE. Ultraprint 2000 HiE Features MODULAR DESIGN ENSURES SUPERIOR ADAPTABILITY

Vibration Suppression R&D at University of British Columbia. Tom Mattison UBC

Specifying Laser Scanning Services. A Quantapoint White Paper

installation guide ACTIV-1

ROTALIGN Ultra is The intelligent System for Machinery Alignment

Length, Finland, MIKES (VTT Technical Research Centre of Finland Ltd, Centre for Metrology / Mittatekniikan keskus)

Subminiature Load Cell Model 8417

Beam Laser Pointer Service Manual

Status of the Diamond Storage Ring RF Systems. Morten Jensen on behalf of Diamond Storage Ring RF Group

How To Use A Ds340 (Dsp)

LHCC TOTEM STATUS REPORT

Zero Degree Extraction using an Electrostatic Separator

[see Figure 3 below] Ferrite tile walls and ceiling RF Absorber parcel walls and ceiling Removable floor section to make fully anechoic

Shielding and Radiation Measurements at ESRF

Development of Virtual Accelerator Environment for Beam Diagnostics *

3 LEVELLING & SURVEYING

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

Trimble Field Link Software

Making Your Home Ready For Solar Water Heating

Status of Radiation Safety System at

END OF LINE SYSTEM TRUCKCAM FACTORY

Status of the Free Electron Laser

TI GPS PPS Timing Application Note

E3T Miniature Photoelectric Sensors

BEPC UPGRADES AND TAU-CHARM FACTORY DESIGN

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections

Compliance Test Results. of Independently Manufactured. Automotive Replacement Headlamps. To FMVSS 108. Study II. May 13, 2004

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Spray Height Control System

Engineered Material Handling. Overhead Bridge Cranes and Gantry Cranes

In Association With. Introduces. TPT Contractor

Environment-Laboratory Ambient Conditions

Pump Skid Fabrication for Magnetic Coupling. Rick Soltis Chief Mechanic City of Bedford

3D SCANNERTM. 3D Scanning Comes Full Circle. s u n. Your Most Valuable QA and Dosimetry Tools A / B / C. The 3D SCANNER Advantage

1-4 kg/m3. Long in-line calibration cycles of the gamma density systems may improve measurement accuracy, but this is often not practical subsea.

Buildings Construction Procurement Strategy

Cathode Ray Tube. Introduction. Functional principle

Solutions Manufacturing Performance

Service Bulletin Trucks Date Group No. Page

3D Laser Scanning Technology. Rugged hardware and powerful software combined with streamlined survey workflow

source at CERN G.McMonagle AB/RF

Press Release. Superior bending

Tube Control Measurement, Sorting Modular System for Glass Tube

Technical specification for the ALBA area radiation monitor network and detectors

ALIGNMENT FOR NEW SUBARU RING

B098N USERS: MACHINE MANUFACTURERS DRAUGHTSMEN OPERATORS MAINTENANCE WORKERS ANY OTHERS

IRB 2600ID-15/1.85 Simple integration, high performance

THE OPTICAL CMM 3D SCANNERS FOR INDUSTRIAL APPLICATIONS

Total Station Setup and Operation. Sokkia SET Total Station

GE Lighting Solutions. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABHX - Series) imagination at work

V K Raina. Reactor Group, BARC

Electrical tests on PCB insulation materials and investigation of influence of solder fillets geometry on partial discharge

Chesapeake Section AWWA Symposium

Project Management Plan

Status of EVOLVE boiling flow regime experiments

Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings

The process components and related data characteristics addressed in this document are:

SE05: Getting Started with Cognex DataMan Bar Code Readers - Hands On Lab Werner Solution Expo April 8 & 9

Transcription:

Status Report on Alignment Activities at SLAC Catherine LeCocq, Robert Ruland Budget Situation SSRL / SPEAR PEPII / Babar LCLS Instrumentation / Calibration 1

Alignment Activities for SPEAR Ring mapping Chicane installation in East pit BTS pipe set-up HLS installation for floor monitoring Insertion devices new undulator for BL12 new chamber but temporary ID for BL13 Beamline work New beamlines: BL12, BL13, BL14 Beamline relocation: BL4 and BL5 Beamline upgrades: BL2, BL7, BL8, BL9 and BL10 2

HLS installation for floor monitoring 3

Floor Motion Movie Real time data can be found here: http://www-group.slac.stanford.edu/met/align/spear3/spear_www/sys2007/autoplot07.html 4

Preliminary Analysis Daily variations in the floor movements seem to be mainly influenced by the outside temperature of the SPEAR3 ring, correlated to the amount of sunshine. The interior temperature of the ring does not seem to have short term effects but seems to be responsible for the annual drift of the floor [G. Gassner]. Real time data can be found here: http://www-group.slac.stanford.edu/met/align/spear3/spear_www/sys2007/autoplot07.html 5

PEPII IR2 vacuum chamber upgrades R3-R4-R5 mapping and moves R4 RF stations R10 for e-cloud chamber for ILC BaBar/IR2 mapping 6

Mapping IR2 / Babar 7

LCLS Injector, bunch compressor system installed in existing tunnels Systems commissioned, work very well 8

LCLS Down beam systems are installed in new tunnels and housings: Linac-to-Undulator Hall Undulator Hall E-beam dump Front End Enclosure Near Experimental Hall X-beam Transport Far Experimental Hall 9

10

LCLS: present and coming activities Started implementation of tunnel reference network in LTU, will soon have access to Undulator Hall, beam dump and FEE Presently, tunnel floors are being coated, will soon start laying-out component positions in parallel Support for Civil Engineering / Construction Coordinate systems QC of sensitive areas Support undulator fiducialization Support girder assembly / internal alignment Very tight alignment tolerances, e.g. 40microns vertical relative combination of height gauges, optical tooling, laser tracker and final alignment on large volume Coordinate Measurement Machine (CMM) 11

LCLS Monitoring Systems LCLS Stretched Wire System All 140 monitors received, electronics and cabling on order: ready for preassembly on girders in May LCLS HLS 80 out of 116 capacitive sensors received, being calibrated 40 ultra sound sensors received, being calibrated Piping material, cabling ready for preassembly 12

Instrumentation News Laser Scanner Upgraded to ZF Imager 5600 continue to be happy customers Acquired another Laser Tracker, Faro Xi V2 400m long portable stretched wire, see poster by G. Gassner, C. LeCocq Re-engineered Linac Laser Alignment system, see poster by C. LeCocq, R. Pushor, B. Fuss, G. Gassner 13

Calibration Vertical Level Rod Comparator is recognized as a national resource, National Geodetic Survey (NGS) requires contractors to have their equipment certified Laser Tracker horizontal angle measurement system test bench First results, test bench internal accuracy 0.2 arcsec More details in separate talk 14

End of Presentation 15