INSTALLATION, OPERATION & MAINTENANCE MANUAL



Similar documents
PBX Series Quick Fit Connector Bimetallic Steam Traps

RMF Engineering

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Fire Hydrant Troubleshooting

Diameter 3" 4" 6" 8" Flange type PN 16 PN 16 PN 16 PN 16. Orange-red ( RAL 2002) Height (cm) 27,70 26,30 28,

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

This instruction is valid for all ACD pump models shown on page 2

Installation, Operating and Maintenance Instructions for AEON Metal Seated Gate Valve (MSGV) Water

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Wafer Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Stainless Steel Single and Dual Circulation Kits

Maintenance and Instruction Manual. December 2011 Rev. 01 Page 1 of 12

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Trouble Shooting. Pump

AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller

Wet alarm valves. Wet alarm valves. FM trim

Maintenance and Service Instruction

Hose and Tube Fittings Series 1-3

TYPE E Main Valve Sizes 3 /8 through 12

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

SureSite Magnetic Liquid Level Indicator

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Universal Installation and Maintenance Instructions 71CD-1212 Spill Containment Bucket

IOM SERIES 820-E/P Electro-Pneumatic Positioner

3620 W 11th Streetб Houston, TX Telephone: sales@kellogg-american.com Website:

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

Owner s Manual. Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

Type and Type Pneumatic Control Valves. Type (left) and Type (right) Mounting and Operating Instructions EB 8026 EN

CHEMICAL CLEANING UNIT Product number:

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

WARNING! WARNING! ENGLISH 18 ENGLISH

Fleetguard CS41018 SpiraTec Centrifuge Rotor Installation Instructions

Lenntech psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

SunMaxx Solar Filling Station Operating Instructions

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

2" & 3" Poly Wet Seal Pump Instruction Manual

FRAME DOOR OPENING, DOOR AND SIDE PANEL OUTER

How Do I Replacing My Rear Brake Pads and Rotors?

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Trunnion-Design Ball Valves

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

OPERATING AND MAINTENANCE INSTRUCTIONS PUMP TYPE

Cooling system components, removing and installing

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

BERMAD Fire Protection

Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations

REPAIR INSTRUCTIONS UNDER BODY CYLINDER (UM, UL)

HYDRAULIC TABLE CART 500-LB.

Flushing and Cleaning the A/C System

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

IMPORTANT SAFETY NOTICE

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION

Sprinkler Identification Numbers

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

M A N U A L

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

3/4 PIPE CLAMP WITH STAND

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

Additions, Revisions, or Updates

1000-LB. TRAILER JACK OWNER S MANUAL

The cylinder head bolts tightening stages have been updated as listed in Table 1.

SINGLE STAGE INLINE FIRE PUMP

BERMAD Fire Protection

Materials : Cast iron body

Hydraulic control unit series

Voltmaster Trash Pumps Model TSP2, TSP3 and TSP4

Instructions cover both:

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

Assembly overview - fuel tank

Baumann 24000SB Barstock Control Valve

How To Use A Flowmeter

Drive shaft, servicing

Operating and installation instructions

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

81000 Series Aluminum Gate Valve Installation and Repair Manual

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

CappController Pipette Controller. Operation Manual Version:

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

BALL VALVE Installation and Operations Maintenance Manual

OPERATION & MAINTENANCE MANUAL. for VERTICAL INLINE PUMPS

Chapter 7 Hydraulic System Troubleshooting

StackFlowMaster FPD580 TORBAR probe Stack gas metering systems. Measurement made easy. Introduction. For more information

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

Installation instruction CASAFLEX - Connecting piece DN 100

Maintenance and Operating Instructions SIS 120P/SISF

HYDRAULIC LIFT TABLE CART 2200-LB.

Bearing Failure: Causes and Cures

TAMPERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

Mini Pallet Jack OWNER S MANUAL

Transcription:

INSTALLATION, OPERATION & MAINTENANCE MANUAL Flanged Disk Check Valve with Strainer Ref. GENEBRE: 2450 2451 2452 1

INSTRUCTIONS FOR INSTALLATION, OPERATION & MAINTENANCE MANUAL 1. Spare parts... 3 1.1 Parts list... 4 2. Storage...4 3. Installation Instructions... 4 3.1 Preparation... 4 3.2 Installation... 5 4. Operating Instructions.....6 4.1 Usage... 6 4.2 Operation... 6 5. Maintenance Instructions...6 6. Repair Instructions... 6 7. Opening Pressure... 7 8. Safety Instructions... 7 2

1) Spare Parts. 3

1.1) Parts List 2) Storage In case that the valve is not installed immediately, keep it with protective packaging to prevent strokes or accumulation of dirt (it should not be removed until the valve is going to be installed). As far as possible, the valves should be stored in a dry and clean area. 3) Installation Instructions 3.1) Preparation Remove any remaining packing materials from the valve. There may be serious problems with any valve installed in a dirty pipe. Make sure the pipe is free of dirt, welding particles, etc. before installation because the valve could get irreparable damage when starting-up prepare a clean working area. Provide enough space for future maintenance. Use flat gaskets between valve and pipe flanges to ensure sealing. 4

Check the correct operation of the valve by pushing the disc (part.3) in the flow direction and noting that it returns on its own once released. Otherwise, check that there are not foreign objects inside the valve and then repeat the operation. If the disc can t move freely, do not install the valve. 3.2) Installation The double disk check valve can be installed in any position, but must take into account the flow direction of the valve marked by an arrow in the body. UPWARD HORIZONTAL DESCENDING BOTTOM VALVE IMPORTANT: - Genebre flanged disk check valve (art. 2452) is designed for mounting between flanges DIN PN16. - Take the precaution of centring the valve with the axis of the pipe in order to ensure sealing between body and flange. - Do not weld with the valve mounted as it could get damage by overheating and produce deformation of the seating area. - Pay particular attention to the flow direction of the valve marked by an arrow in the body. - Check the parallelism of the flanges. Keep enough space between them so that the valve can be inserted or removed easily. - Tighten the screws of the flanges to hold the valve body firmly. Apply the alternate clamping method to ensure proper installation. 5

- The valve should never be mounted adjacent to an elbow, reducer, valve or pump, to avoid turbulence. The recommended minimum distance between these elements is 10 times the diameter of the pipe - upstream - and 3 times the diameter of the pipe - downstream according to CR 13932:2000. 4) Operating Instructions 4.1) Usage Check valves are used mainly to prevent backward flow in the system. These valves are made for being installed between flanges, and provide a tight seal when are used respecting the values of pressure / temperature for which they are designed. The material of the valve body, seat and other components must be compatible with the fluid going through the valve; otherwise the valve can be seriously damaged. Another application of the valve, assembled with strainer (art. 2452), can be used as an aspiration valve. 4.2) Operation This type of valve, by definition, does not require any operation. Opening and closing is done automatically depending on the pressure and flow direction. For more information about the opening pressure of the valve consult the technical data sheet of the product. 5) Maintenance Instructions Check valves do not require regular maintenance and lubrication during their life. However, the following regular checks will help to extend the life of the valve and reduce problems in the installation: - keep the valve in the fully closed position. - check that all screws and threaded unions are not loose or rusted. Tighten if necessary. - Inspect the valve and surrounding areas to check that there is not any leakage. 6) Repair Instructions This type of valves, due to their easy assembling and reduced production cost are not worth repairing, because most of the times is simply not cost-effective, so we recommend to directly replace it. 6

7) Opening Pressure The flanged disc check valve (art. 2450) has been designed to work with minimum opening pressure (for details see technical data sheet of the product). 8) Safety Instructions 8.1) The fluids pass through a valve can be corrosive, toxic, flammable or pollutant. When handling valves shall be taken necessary security measures and it is advisable to use personal protective equipment: 1) Wear eye protection. 2) Wear gloves and appropriate work clothes. 3) Wear safety shoes. 4) Wear a helmet. 5) Note the availability of running water. 6) For flammable fluids, make sure you have a fire extinguisher. 8.2) Before removing a valve from a pipe, always check that the line is completely cold, drained and depressurized. 8.3) Any valve that was used in toxic services must have a cleaning certificate before handling. 7