PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 6mm R SNC, SLE G4 10mm R SNC umodule SLE ESSENCE

Similar documents
LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC / CLE CLASSIC umodule CLE

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens CLASSIC umodule QLE

LED light engine / OLED LED linear /area. Umodule STARK LLE CLASSIC STARK LLE. Ordering data

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-2 umodule SPOT PHASED OUT NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P340-2 umodule SPOT PHASED OUT NTC

LED light engine / OLED LED flexible. Umodule LLE-FLEX umodule LLE FLEX ADVANCED

LED light engine / OLED LED compact. Uengine STARK DLE PREMIUM system data sheet STARK DLE

FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat

COOL Shelf Quick Connect

LINEAR SYSTEM 3000K 4000K 5000K 6000K 7000K

Fortimo LED Line Gen3

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

Fortimo LED SLM Gen4

LED Module SPECIFICATION. LED Module for Modular Platform Series. LED Platform Module with Fin

Nominal Power [W] Radiance Angle [ ] Color Temp. [K]

LED control gear. LED control gear

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

50W EdiStar. Approved By Customer. Designer Checker Approval. Ultra High Power LED

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series

Flux CCT. CRI SDCM (lm) (K) (V) (ma) (W) (lm/w)

Radiance Angle [ ] Color Temp. [K]

Emergency lighting units EM powerled

CHM-27 COB Arrays White LED

Radiance Angle [ ] Nominal Power [W] Color Temp. [K]

LED Driver Compact dimming. Udriver LCAI 35W 350mA 900mA ECO C ECO series

InGaN / Sapphire White Water clear. Parameter Rating Unit

Discontinued. LUXEON V Portable. power light source. Introduction

3W RGB High Power LED

MP-1919 XNOVA Cube TM SMD LED

Applications. Wall Washing effects Accent Lighting Ambient Lighting Edge and Injection Lighting of transparent or diffuse materials

T5 Watt-Miser Linear Fluorescent lamps

3mm Photodiode,T-1 PD204-6C/L3

LZC-00MC40. LedEngin, Inc. High Luminous Efficacy RGB LED Emitter. Key Features. Typical Applications. Description

No. 3, Gongye E. 3rd Road, Hsinchu Science Park, Hsinchu 30075, Taiwan TEL: Lextar.com 50W-100W COB LED. Updated on 2012/010/11

T5 LongLast. GE Lighting DATA SHEET

Power Resistor for Mounting onto a Heatsink Thick Film Technology

C W COB Series

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Mounting Instructions for SP4 Power Modules

120W High Bay II Datasheet

C W COB Series

High flux for outdoor applications

EVERLIGHT ELECTRONICS CO.,LTD. Technical Data Sheet High Power LED 1W (Preliminary)

Features. High Brightness LED Light source

LUXEON S. High Flux Density

PLVZ1-LIN DC > , PLVZ1-LIN DC > ,

WL-SWTC SMD White Top View Ceramic LED

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Bridgelux ES Array Series

1W High Power Purple LED Technical Data Sheet. Part No.: LL-HP60MUVA

Contents. 12. Lot Number Reel Packing Structure Precaution for Use Hazard Substance Analysis Revision History 18

Features. Typical Applications G9. ProLight PEA2-3FVE 3W Warm White AC LED Technical Datasheet Version: DS-0042

Apples & Pears, a CELMA guiding paper: Why standardisation of performance criteria for LED luminaires is important

2016 Mid Power LED Mid Power Product Datasheet. Features: Table of Contents. Applications

HL-A-3528H308W-S1-13. Description. Applications. Recommended Soldering. Package Dimensions

30W Epistar 45mil Chip High Power LED

1 W High Power LED TPLG-MR7171R-H11-0L0M. 1 W High Power Warm White LED. Features. Applications. Device Selection Guide

STRATO LED Drivers 70W, Single output

5W HI-POWER LED SPECIFICATION

Biax S and S/E. Compact Fluorescent Lamps Non-Integrated 5W, 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Features.

0.45mm Height 0402 Package Pure Green Chip LED Technical Data Sheet. Part No.: LL-S160PGC-G5-1B

3W High Power LED. Features. Applications. Catalog

P2N LED. High Power LED PRODUCT DATASHEET. Introduction. RoHS Compliant

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

LUXEON TX Extreme efficacy that will transform your next market leading luminaire

SPECIFICATION. PART NO. : MT0380-UV-A 5.0mm ROUND LED LAMP. 3Northway Lane North Latham,New York

Linear Luminaire with LED Series EXLUX 6402/2

P2O LED. High Power LED PRODUCT DATASHEET. Introduction. RoHS Compliant

A Guide to the Specification of LED Lighting Products 2012

Multiple colors, a single focal length

Edixeon S5 White Series Datasheet

High / Low Bay Datasheet

Flexible LED system approach

Data Sheet. ASMT-Mx00 Moonstone TM 1 W Power LED Light Source. Features. Description. Specifications. Applications

Power Resistor Thick Film Technology

LED BUILT-IN MODULES. LUGA Shop 2013 LED Modules COB for Retail Environments. LUGA SHOP 2013 HiCRI lm TO 5000 lm. LUGA SHOP 2013 HiCRI

LUXEON CoB with CrispWhite Technology Retail lighting that makes an impact

Technical Data. Dimensions

50 W Power Resistor, Thick Film Technology, TO-220

1.50mm Height 2220 Package Top View Full Color Chip LEDs Technical Data Sheet. Part No.: LL-R5050RGBC-001

Specific information for LED applications. BJB///OEM-Line. The smartest route to your LED application. Your Connection to Light

IVIOS LED III. LUM Technical Information

Distributed Array LED Modules High efficacy solutions for diffuse ambient lighting

Data Sheet. HLCP-A100 LED Light Bars

High / Low Bay PC Reflector Datasheet

SLLP G PRODUCT DATASHEET. RoHS Compliant

connecdim Gateway G1 Ethernet TCP/IP to DALI

The most sustainable lighting solution. QL 85W Induction Lighting System

EVERLIGHT ELECTRONICS CO., LTD. Technical Data Sheet 0805 Package Chip LED Preliminary

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

HLMP-1600, HLMP-1601, HLMP-1620, HLMP-1621 HLMP-1640, HLMP-1641, HLMP-3600, HLMP-3601 HLMP-3650, HLMP-3651, HLMP-3680, HLMP-3681

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

IR Edixeon Emitter. 1W Edixeon

Cree XLamp MX-6 LEDs Data Sheet

AOK i Series LED High Bay / Flood / Tunnel Light

Electric Rotary Actuator - On/Off or programmable control actuator

Cross-beam scanning system to detect slim objects. 100 mm in

DuroSite TM High Bay Lighting

WCAP-CSGP Ceramic Capacitors

Transcription:

w LED light engine / OLED Product description For general lighting application Typ. luminous flux category: 3/6/8/1,2 lm High efficacy up to 133 lm/w for the LED module at tp = 25 C Small LES (light emitting surface) diameter enables narrow beam angle for spotlights Excellent thermal management by COB technology Uniform radiation with Dam&Fill technology Housing for LES1 is availiable as an option Cooling required Flexible operating modes È Standards, page 4 Colour temperatures and tolerances, page 9 and 1 Umodule SLE G4 6mm R SNC, SLE G4 1mm R SNC umodule SLE ESSENCE www.tridonic.com 1

Technical data Beam characteristic 115 Ambient temperature ta -3... +75 C tp_rated temperature 1 65 C Max. tc point temperature 1 up to 1 C Risk group (EN 62471:28) 1 Type of protection Specific technical data Type Forward Luminous flux Luminous Power current 345 at flux at consumption 6 tp = 25 C 2 tp = 65 C 2 Min. forward voltage at tp = 65 C Max. forward voltage at tp = 25 C Luminous efficacy module at tp = 25 C Luminous efficacy module at tp = 65 C Colour rendering index CRI SLE G4 6mm 3lm 827 R SNC 827/349 35 ma 414 lm 362 lm 3.7 W 8.11 V 9.64 V 129 lm/w 116 lm/w 82 A+ SLE G4 6mm 3lm 83 R SNC 831/349 35 ma 427 lm 374 lm 3.7 W 8.11 V 9.64 V 133 lm/w 12 lm/w 82 A+ SLE G4 1mm 6lm 827 R SNC 827/349 7 ma 798 lm 75 lm 6.36 W 8.43 V 9.96 V 122 lm/w 11 lm/w 82 A+ SLE G4 1mm 6lm 83 R SNC 831/349 7 ma 83 lm 737 lm 6.36 W 8.43 V 9.96 V 128 lm/w 115 lm/w 82 A+ SLE G4 1mm 8lm 827 R SNC 827/349 25 ma 1,81 lm 944 lm 9.11 W 33.93 V 39.91 V 115 lm/w 15 lm/w 82 A+ SLE G4 1mm 8lm 83 R SNC 831/349 25 ma 1,19 lm 98 lm 9.11 W 33.93 V 39.91 V 118 lm/w 19 lm/w 82 A+ SLE G4 1mm 8lm 84 R SNC 841/349 25 ma 1,21 lm 1,5 lm 9.11 W 33.93 V 39.91 V 127 lm/w 116 lm/w 82 A+ SLE G4 1mm 12lm 827 R SNC 827/349 35 ma 1,48 lm 1,274 lm 12.66 W 33.53 V 39.63 V 112 lm/w 12 lm/w 82 A+ SLE G4 1mm 12lm 83 R SNC 831/349 35 ma 1,535 lm 1,349 lm 12.66 W 33.53 V 39.63 V 117 lm/w 18 lm/w 82 A+ SLE G4 1mm 12lm 84 R SNC 841/349 35 ma 1,593 lm 1,374 lm 12.66 W 33.53 V 39.63 V 122 lm/w 11 lm/w 82 A+ 1 If the max. temperature limits are exceeded, the life of the system will be greatly reduced or the system may be damaged. The temperature of the umodule at the tp-point is to be measured in the thermally stable state with a temperature sensor or temperature-sensitive sticker as per EN 6598-1. For the precise position of the tp point see the drawing above. 2 Tolerance range for optical data: ±1 %. 3 Exceeding the max. operating current leads to an overload on the umodule. This may in turn result in a significant reduction in life-time or even destruction of the umodule. 4 Max. permissible surge current for SLE G4 6mm 3lm xxx R SNC: 1.44 A, duration max. 1 ms. Max. permissible surge current for SLE G4 1mm 6lm xxx R SNC: 2.4 A, duration max. 1 ms. Max. permissible surge current for SLE G4 1mm 8lm xxx R SNC:.8 A, duration max. 1 ms. Max. permissible surge current for SLE G4 1mm 12lm xxx R SNC: 1.2 A, duration max. 1 ms. 5 Max. permissible repetitive peak current for SLE G4 6mm 3lm xxx R SNC: 72 ma. Max. permissible repetitive peak current for SLE G4 1mm 6lm xxx R SNC: 1,2 ma. Max. permissible repetitive peak current for SLE G4 1mm 8lm xxx R SNC: 4 ma. Max. permissible repetitive peak current for SLE G4 1mm 12lm xxx R SNC: 6 ma. 6 All values at tp = 65 C. IP Umodule SLE G4 6mm R SNC, SLE G4 1mm R SNC umodule SLE ESSENCE,9,5 ±,1 SLE G4 6mm, 3lm SLE G4 1mm, 6/8lm SLE G4 1mm, 12lm Ø6,4 Dimensions in mm Ordering data,9,5 ±,1 Ø9,4,9,4 ±,1 Ø9,4 1 13,5 13,5 Ø5,2 Ø8,2 Ø8,2 Ø4 (2x) Ø4 (2x) Type Article Colour Connection Packaging Weight number temperature cable per pc. SLE G4 6mm 3lm 827 R SNC 28817 2,7 K no 5 pc(s)..1 kg SLE G4 6mm 3lm 83 R SNC 28818 3, K no 5 pc(s)..1 kg SLE G4 1mm 6lm 827 R SNC 28821 2,7 K no 36 pc(s)..1 kg SLE G4 1mm 6lm 83 R SNC 28822 3, K no 36 pc(s)..1 kg SLE G4 1mm 8lm 827 R SNC 28825 2,7 K no 36 pc(s)..1 kg SLE G4 1mm 8lm 83 R SNC 28826 3, K no 36 pc(s)..1 kg SLE G4 1mm 8lm 84 R SNC 281217 4, K no 36 pc(s)..1 kg SLE G4 1mm 12lm 827 R SNC 28829 2,7 K no 36 pc(s)..1 kg SLE G4 1mm 12lm 83 R SNC 2883 3, K no 36 pc(s)..1 kg SLE G4 1mm 12lm 84 R SNC 28831 4, K no 36 pc(s)..1 kg Photometric code Energy classification www.tridonic.com 2

Product description Housing for LES 1 Diameter: 35 mm ACCES- SORIES SLE G4 housing for LES 1 Ordering data max. 3,5 LES 1 Ø35 25 Ø1 Type Article number Packaging bag Weight per pc. SLE G4 HOUSING LES 1 28138 1 pc(s)..2 kg www.tridonic.com 3

1. Standards 2.3 Derating curves EN 6231 EN 62471 EN 61547 EN 5515 IEC 62717 1.1 Photometric code Key for photometric code, e. g. 83 / 469 1 st digit 2 nd + 3 rd digit 4 th digit 5 th digit 6 th digit Luminous flux after 25% Code CRI McAdam after of the life-time (max.6h) Colour temperature in McAdam 25% of the Code Luminous flux 7 7 79 Kelvin x 1 initial life-time 7 7 % 8 8 89 (max.6h) 8 8 % 9 9 9 9 % 2. Thermal details 2.1 tp point, ambient temperature and life-time The temperature at tp reference point is crucial for the light output and life-time of a u product. The operating temperature of a u product is crucial for the light output, the product life-time but also for the product safety. The thermal limits can be checked at the tp/tc point and at tr. In chapter 5.3 the lumen maintenance is shown in relation to the temperature at tp. tp,rated shows the temperature at which the rated values are reached. tc shows the thermal limit for safety reason und must never be exceeded under normal conditions. For the interchangeablity with other Zhaga products, tr,max is specified directly at the thermal interface to the heatsink of the luminaire. For umodule SLE G4 R SNC a tp temperature of 65 C has to be complied in order to achieve an optimum between heat sink requirements, light output and life-time. Compliance with the maximum permissible reference temperature at the tp point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application. 2.2 Thermal behaviour storage temperature -3... +8 C operating temperature ta -3... +75 C tp (at typ. current) 65 C tc temperature as a function of the current acc. to the derating curves SLE G4 6mm 3lm xxx R SNC If [ma] 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 1 11 Tc [ C] SLE G4 1mm 6lm xxx R SNC If [ma] 1 9 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 1 11 Tc [ C] SLE G4 1mm 8lm xxx R SNC If [ma] 4 35 3 25 2 15 1 5 1 2 3 4 5 6 7 8 9 1 11 Tc [ C] SLE G4 1mm 12lm xxx R SNC If [ma] 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 1 Tc [ C] www.tridonic.com 4

2.4 Thermal design and heat sink 3. Installation / wiring The rated life of u products depends to a large extent on the temperature. If the permissible temperature limits are exceeded, the life of the umodule SLE G4 R SNC will be greatly reduced or the umodule SLE G4 R SNC may be destroyed. Therefore the umodule SLE G4 R SNC needs to be mounted onto a heat sink heat sink which does not exceed the value for Rth,max. Tridonic s excellent thermal design for the umodule SLE G4 R SNC products provides the lowest thermal resistance and therefore allowing new compact designs without sacrificing quality, safety and life-time. 2.5 Heat sink values SLE G4 6mm 3lm xxx R SNC ta tp Operating current Rth, hs-a Cooling area 25 C 65 C 35 ma 18.31 K/W 36 cm 2 3 C 65 C 35 ma 15.96 K/W 42 cm 2 4 C 65 C 35 ma 11.26 K/W 59 cm 2 5 C 65 C 35 ma 6.56 K/W 12 cm 2 SLE G4 1mm 6lm xxx R SNC ta tp Operating current Rth, hs-a Cooling area 25 C 65 C 7 ma 8.71 K/W 77 cm 2 3 C 65 C 7 ma 7.59 K/W 88 cm 2 4 C 65 C 7 ma 5.34 K/W 125 cm 2 5 C 65 C 7 ma 3.1 K/W 215 cm 2 SLE G4 1mm 8lm xxx R SNC ta tp Operating current Rth, hs-a Cooling area 25 C 65 C 25 ma 5.92 K/W 113 cm 2 3 C 65 C 25 ma 5.15 K/W 13 cm 2 4 C 65 C 25 ma 3.6 K/W 185 cm 2 5 C 65 C 25 ma 2.5 K/W 325 cm 2 SLE G4 1mm 12lm xxx R SNC ta tp Operating current Rth, hs-a Cooling area 25 C 65 C 35 ma 4.14 K/W 165 cm 2 3 C 65 C 35 ma 3.59 K/W 19 cm 2 4 C 65 C 35 ma 2.49 K/W 274 cm 2 5 C 65 C 35 ma 1.38 K/W 495 cm 2 Thermal resistance Rth, j-p Luminous flux Rth, j-p 3 lm 4.74 K/W 6 lm 2.89 K/W 8 lm 2.61 K/W 1,2 lm 2.2 K/W Notes The actual cooling can differ because of the material, the structural shape, outside influences and the installation situation. A thermal connection between umodule SLE G4 R SNC and heat sink with heat-conducting paste or heat conducting adhesive film is absolutely necessary. Additionally the umodule SLE G4 R SNC has to be fixed on the heat sink with M3 screws to optimise the thermal connection. Use of thermal interface material with thermal conductivity of l > 1 W/mK and layer thickness of interface material with max. 5 µm or a similar interface material where the quotient of layer thickness and thermal conductivity b < 5 µmmk/w. 3.1 Electrical supply/choice of LED Driver umodule SLE G4 R SNC from Tridonic are not protected against overvoltages, overcurrents, overloads or short-circuit currents. Safe and reliable operation can only be guaranteed in conjunction with a LED Driver which complies with the relevant standards. The use of u LED Drivers from Tridonic in combination with umodule SLE G4 R SNC guarantees the necessary protection for safe and reliable operation. umodule SLE G4 R SNC are basic isolated up to 5 V against ground and can be mounted directly on earthed metal parts of the luminaire. If the max. output voltage of the LED Driver (also against earth) is above 5 V, an additional isolation between LED module and heat sink is required (for example by isolated thermal pads) or by a suitable luminaire construction. At voltages > 6 V an additional protection against direct touch (test finger) to the light emitting side of the module has to be guaranteed. This is typically achieved by means of a non removable light distributor over the module. If a LED Driver other than Tridonic uconverter is used, it must provide the following protection: Short-circuit protection Overload protection Overtemperature protection umodule SLE G4 R SNC must be supplied by a constant current LED Driver. Operation with a constant voltage LED Driver will lead to an irreversible damage of the module. Wrong polarity can damage the umodule SLE G4 R SNC. 3.2 Wiring example L N Udriver LC... + 3.3 Wiring type and cross section The wiring has to be solid cable with a cross section of.5 to.75 mm² or with stranded wire with soldered ends with a cross section of.5 mm². + + www.tridonic.com 5

3.4 Mounting instruction umodule SLE G4 R SNC from Tridonic which have to be installed on a heat sink have to be connected with heat-conducting paste or heat conducting adhesive film and fixed with M3 screws. The fixing/cooling surface must be cleaned by removing all dirt, dust and grease before installing the u modules. None of the components of the umodule SLE G4 R SNC (substrate, LED, electronic components etc.) may be exposed to tensile or compressive stresses. Max. torque for fixing:.5 Nm. The umodule SLE G4 R SNC modules are mounted with 2 screws per module. In order not to damage the modules only rounded head screws and an additional plastic flat washer should be used. For further information please refer to to the brochure entitled Technical Design-In-Guide SLE GEN4. Chemical substance may harm the LED module. Chemical reactions could lead to colour shift, reduced luminous flux or a total failure of the module caused by corrosion of electrical connections. Materials which are used in LED applications (e.g. sealings, adhesives) must not produce dissolver gas. They must not be condensation curing based, acetate curing based or contain sulfur, chlorine or phthalate. Avoid corrosive atmosphere during usage and storage. 4. Electrical values 4.1 Forward voltage vs. forward current 3 lm: VF [V] 1, 9, 3.5 EOS/ESD safety guidelines 8, 1 2 3 4 5 6 IF [ma] The device / module contains components that are sensitive to electrostatic discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just normal installation practice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/esd-protection www.tridonic.com 6

6 lm: 1, VF [V] 9, 8, 8 lm: VF [V] 4, 37,5 35, 32,5 3, 12 lm: VF [V] 4, 37,5 35, 32,5 2 3 4 5 6 7 8 IF [ma] 1 15 2 25 3 35 4 IF [ma] 3, 1 2 3 4 5 6 IF [ma] The diagrams based on statistic values. The real values can be different. www.tridonic.com 7

4.2 Forward voltage vs. tp temperature 1,5 1,4 1,3 VF [1] 1,2 1,1 1,,99,98,97,96,95 1 2 3 4 The diagrams based on statistic values. The real values can be different. 5 6 7 8 9 tp [ C] 1 www.tridonic.com 8

5. Photometric characteristics 5.1 Coordinates and tolerances according to CIE 1931 The specified colour coordinates are measured integral after a settling time of 1 ms. The current impuls depends on the module type. Module type SLE G4 6mm 3lm xxx R SNC SLE G4 1mm 6lm xxx R SNC SLE G4 1mm 8lm xxx R SNC SLE G4 1mm 12lm xxx R SNC The ambient temperature of the measurement is ta = 25 C. The measurement tolerance of the colour coordinates are ±.1. 2,7 K x y Centre.4599.416,43,425,42,415,41,45,4,395,39,44,445,45,455,46 MacAdam ellipse: 3SDCM 3, K x y Centre.43.416,42,415,41,45,4,395,39,385,38,41,415,42,425,43 MacAdam ellipse: 3SDCM,465,435,47,44,475,445,48,45 Current impulse 35 ma 7 ma 25 ma 35 ma norm. intensity [W/nm] norm. intensity [W/nm].1.9.8.7.6.5.4.3.2.1 38 42 46 5 54 58 62 66 7 74 78 wave length [nm].5.4.3.2.1 38 42 46 5 54 58 62 66 7 74 78 wave length [nm] www.tridonic.com 9

4, K x y Centre.3761.374,395,39,385,38,375,37,365,36,355,355,36,365,37,375 MacAdam ellipse: 3SDCM 5.2 Light distribution relative intensity [%] 1 8-5 6-6 4 2-9 1,38,385-1 -2-3 -4 8 6 4,39,395 1 2 2 4 2 3 4 6 5 6 7 8 9 8 1 norm. intensity [W/nm].12.1.8.6.4.1 38 42 46 5 54 58 62 66 7 74 78 wave length [nm] www.tridonic.com 1

5.3 Relative luminous flux vs. tp temperature rel. luminous flux 1,14 1,1 1,8 1,6 1,4 1,2 1,,98,96,94,92,9 1 2 3 4 5.4 Relative luminous flux vs. forward current rel. luminous flux [lm] 14 12 1 8 6 4 2 1 2 3 4 5 6 7 8 9 tp [ C] 5 6 7 8 9 IF [ma] 1 1 3 lm 6 lm 8 lm 12 lm www.tridonic.com 11