Two-Phase Evaporative Precision Cooling Systems

Similar documents
GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Defining Quality. Building Comfort. Precision. Air Conditioning

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

CRAC Precision climate control units for data centres

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Advanced Heat Reclaim Systems. Harrison Horning, PE, CEM Delhaize America - Hannaford

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

IV. Rear Mount System

Reducing Data Center Energy Consumption

INFO HTK. Hybrid dry cooler. The reference for hybrid dry cooling ,000 kw

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

How and Why Mission- Critical Cooling Systems Differ From Common Air Conditioners

How To Understand Evaporator

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

Glossary of Heating, Ventilation and Air Conditioning Terms

Refrigeration Basics 101. By: Eric Nelson

Rittal Liquid Cooling Series

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling

Alcatel-Lucent Modular Cooling Solution

Low GWP Replacements for R404A in Commercial Refrigeration Applications

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

HVAC Systems: Overview

HEATER, AIR CONDITIONING AND VENTILATION

AIRAH Presentation April 30 th 2014

Why and How we Use Capacity Control

The Pros and Cons of Modular Systems

Choosing Close-Coupled IT Cooling Solutions

Customized Assessment Blueprint

Nirvana. Cycling Refrigerated Dryers

Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: Fax:

Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

Daikin Altherma hybrid heat pump. The natural combination

Reliability of Air Moving Fans, and Their Impact on System Reliability. A White Paper from the Experts in Business-Critical Continuity TM

Opportunity of Energy Saving in electrical path is lesser as compared to other areas

RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.

Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle

HPC TCO: Cooling and Computer Room Efficiency

MAC-120HE-01 Air-Cooled Chiller

Solar power Availability of solar energy

Data Center Facility Basics

Using Portable Spot Air Conditioners in Industrial Applications

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Electrical Drive Modeling through a Multiphysics System Simulation Approach

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

BRASH Air-Steam Hybrid Technology for Combined Heat and Power (CHP)

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Typical Air Cooled Data Centre Compared to Iceotope s Liquid Cooled Solution

Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29

Test Code: 8297 / Version 1

Heat Pump Water Heater IOM Manual

Failure code manual. content

Testing methods applicable to refrigeration components and systems

Building Energy Systems. - HVAC: Heating, Distribution -

Heat Pipe Cooling of Concentrating Photovoltaic (CPV) Systems

Direct Fresh Air Free Cooling of Data Centres

Why Do I Need Precision Air Conditioning?

Data Center RD&D at EPRI

Water cooled chiller plant (cp/vs)

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

White Paper Rack climate control in data centres

Table Z. Troubleshooting Chart for Air Conditioners. Cause

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

European Code of Conduct for Data Centre. Presentation of the Awards 2016

Multi Drum Heat Storage By John Canivan

EFFICIENT ELECTRICAL ENERGY TRANSMISSION AND DISTRIBUTION INTERNATIONAL ELECTROTECHNICAL COMMISSION

vacon ac drives for mining & minerals

Chilled Water HVAC Systems

Scalable. Affordable. Flexible. Fast.

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

RPV - RP - RA air handling units

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

Take the complication out of cooling. Data center cooling equipment and service from Alfa Laval

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

Data Center Technology: Physical Infrastructure

Qualitative Analysis of Power Distribution Configurations for Data Centers

High School Graduation years 2013, 2014, Unit/Standard Number

Why Daikin? 2015 Houston, Texas USA

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

Managing Data Centre Heat Issues

Controlling a 2-phase CO 2 loop using a 2-phase accumulator

CONDENSATION IN REFRIDGERATED BUILDINGS

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

C. starting positive displacement pumps with the discharge valve closed.

Air Conditioning System

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING

Pressure sensors for automotive HVAC systems

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

How To Use A Water Source Heat Pump

AIR CONDITIONING LIFE EXTENDER ACX10 FIELD INSTALLATION AND PERFORMANCE EVALUATION

Impact of Control System Technologies on Industrial Energy Savings

Transcription:

Two-Phase Evaporative Precision Cooling Systems For heat loads from 3 to 300kW

Using non-conductive refrigerant fluid, our patented Next-generation, two-phase evaporative precision cooling systems enable up to twice the power density at a lower system cost Parker s two-phase evaporative liquid cooling system is based on our own patented technology, and uses noncorrosive, non-conductive fluid which vaporizes and cools hot surfaces on contact. Ideal for high power electronics systems where heat loads have moved beyond what traditional air and water cooling systems can effectively manage. By combining a non-conductive dielectric refrigerant with the science of heat dissipation through vaporization, our evaporative cooling technology increases power densities for high power electronics by more that 2x. Our evaporative precision cooling system offers a safer and more efficient method of heat transfer. Although the systems are leak tight, should an accidental leak occur, the non-conductive fluid is inherently safe even when in direct contact with sensitive electronics. Integrating the high heat removal of two-phase technology with the reliability of low-flow liquid pumping, our system is highly modular (hot swappable) and scalable. With such high-efficiency, it simplifies the plumbing and reduces the overall weight, giving it an excellent thermal performance/cost ratio. And, due to the inherent non-corrosive properties of the fluid, no regular end user maintenance is required. 2-PHASE EVAPORATIVE COOLING SYSTEM ADVANTAGES Increased power density Reduced weight Smaller enclosures 2 to 4 times better heat transfer Lower flow rates 80% less than that of EG water systems Increased system reliability and MTBF Safer no risk of electrical shorting Modular; scalable; hot swappable No altitude or hot climate de-rating Isothermal, increasing silicon life and simplifying plumbing Smaller pumps with 50,000 L10 life Opportunity for reduced wiring, switchgear, magnetics Ability to free cool reduced HVAC system heat load 85% reduced energy consumption Shorter commissioning time Maintenance-free; no set-up, biocides, filters, tear downs Less thermal cycling for increased electronics life 1

cooling technology increases the throughput of high power electronics by up to 40%. CONSIDER 2-PHASE EVAPORATIVE COOLING FOR APPLICATIONS THAT: Have critical packaging constraints Have a propensity for high cyclical loads Call for more power output from a given device package (e.g., increased switching frequency or difficulty in paralleling devices) Feature multiple loads connected in series / parallel in the cooling loop Need modular and easy field service (quick dry break connectors) Involve high-voltage and use de-ionized water Want to eliminate the chiller 2

How evaporative cooling works 1 The fluid flows through hard tubing or hose to a low-flow pump. 4 2 Pump moves saturated fluid across a cold plate directly underneath the heat source. With the latent heat transfer, the fluid immediately starts to vaporize. 3 Heat is carried away by the vapor. 4 Vapor moves to an air- or water-cooled condenser where it re-condenses into fluid and the heat is dissipated. 3 5 Excess fluid is stored in the accumulator ready to be pumped back into the system. GREATER DESIGN FLEXIBILITY Because our system is isothermal, we eliminate the thermal stack-up issues that plague most designs. This allows the design engineer to package the electronics in a way that makes the most sense for the application rather than make compromises because of the cooling system. TAKING LIQUID COOLING TO THE NEXT LEVEL This efficient cooling process continuously cycles the refrigerant within a sealed, closed-loop system to cool a wide range of systems including power electronics, motors, transformers, and batteries. The system uses a small pump to deliver just enough coolant to the evaporator - usually a series of one or more cold plates optimized to acquire the heat from the device(s). In so doing, the two-phase coolant begins to vaporize maintaining a cool uniform temperature on the surface of the device. The vaporized coolant is then pumped to a heat exchanger where it rejects the heat to the ambient and condenses back into a liquid, completing the cycle. Dielectric Fluid R134a A commonly used refrigerant, R134a is dielectric, flashes to gas at ambient temperatures, does not react with metals, and is intrinsically harmless. Newer fluids are under development that have similar properties but better global warming ratings. Such fluids will be drop-in replacements. 3 Download technical articles and white papers at Get the free mobile app for your phone http:// www.parkerprecisioncooling.com gettag.mobi

5 1 2 GREATER HEAT TRANSFER A simplified design utilizing one piece of copper folded into numerous fins creates greater area for heat transfer. Proven Parker components make the system low-maintenance and field serviceable Low Heat Mode Moderate Heat Mode High Heat Mode Self-optimizing and Isothermal Utilizing latent heat transfer makes the system self-optimizing: As heat loads increase, more fluid vaporizes, taking away more heat. In addition, stack-up problems are eliminated because the temperature of every cold plate remains the same regardless of location. Consequently, vaporization temperature is constant while the amount of vaporization is variable. Dry Break Connectors Unique to our cooling system are two dry break connectors. These allow a quick disconnect so critical system components can be rapidly isolated and serviced in the field efficiently. Dry break connectors do more than minimize maintenance downtime, though they also make installation faster and easier. Low-Flow-Rate Pump Derived from Parker pumps developed for aerospace and automotive applications, the hermetically sealed pump uses positive displacement to create flow and suction to move the fluid. The pump moves the fluid through the loop at a pressure just above the level where the fluid at ambient temperature would flash to gas. A brushless DC motor provides a 50,000-hour L10 continuous-duty life. 4

How 2-Phase Evaporative Precision Cooling Compares A series of tests in which we drove an IGBT module until the junction temperature reached 120ºC. We then utilized different cooling methods and measured the resulting heat loss. Technologies Convection Air: 40ºC ambient, 150CFM Pressed Tube Water Cold Plate: 3 cold plates; 6 gpm; 40ºC ambient; 50ºC fluid temperature Extended Surface Water Cold Plate: 3 cold plates; 6 gpm; 40ºC ambient; 50ºC fluid temperature Parker Two-Phase Extended Surface With R134a: 3 cold plates; 1.2 gpm; 40ºC ambient; 50ºC fluid temperature RESULTS Module Loss (W) for 120ºC junction Steady State Module Loss (W) for 120ºC junction 220% Overload 600 405 0.094 736 437 0.051 1070 500 0.035 1461 568 0.008 Parker provides us with a more reliable thermal management solution for our modular, high frequency power supply systems ranging from 30 to 360kW. Jason Horn, Stock Equipment Company Heat Sink/Cold Plate Resistance ºC/W CASE STUDY: Cooling Stock Equipment s ModuPower TM High Frequency Power Supply Systems Overview: Stock Equipment Company designs power supply systems for electrostatic precipitators (ESPs), highly efficient filtration devices used for emissions control in coal-fired power plants and other industrial processes. ESPs remove coal-ash particles before they can go up the stack, thereby mitigating the risk of EPA violations, and subsequent plant curtailments and shutdowns. A recent decision by Stock to sell a high frequency Switched Mode Power Supply system (SMPS) named ModuPower TM with its Norwegian partner Applied Plasma Physics allowed Stock to adopt Parker s innovative cooling technology. With water cooling, every project required a custom design, said Jason Horn, lead engineer at Stock Equipment. External water piping to chillers or large external heat exchangers was impractical for most applications. Limited installations also suffered extended down time due to water-cooling issues. We needed a more reliable and scalable thermal management system that fit a standardized design process, was less complex, and eliminated water-cooling issues. Parker s two-phase system uses Evaporative Precision Cooling System to cool. The system is self-optimizing and isothermal; as temperatures rise in the power supply system, more dielectric fluid vaporizes, taking away more heat. Plus Parker s System is modular and scalable like our SMPS, allowing us to standardize the design and easily add more cooling for higher output ratings as needed. Results: Stock Equipment s high frequency Switched Mode Power Supply systems are now running without failure, minimizing EPA fines. ESP power densities have been increased by over 100% and improved ambient temperature ratings of 40 to +50ºC surpass the competition. Evaporative cooling has also enabled the use of smaller refrigerant pumps and cooling fans for added energy savings. 5

Markets & Applications Renewable Energy Solutions The less weight in the nacelle or power conversion container, the better. Parker s two-phase evaporative cooling system is available in a rack-ready design, or can be configured as a drop-in replacement solution to easily retrofit legacy water or air cooling systems. Parker can cool the full range of wind turbine/power generation systems, including the converter/inverter, reactor, transformer and generator with compelling benefits, including: Scalability: 20 300 Kw of cooling Cost: up to 20% system level cost savings Power Density: 2x or more increase in power density Size and Weight: up to 50% smaller/lighter Safety: The fluid used is non-corrosive, does not conduct electricity and needs no freeze protection Service: Hermetically sealed system with 50,000 hr L10 life. No regular service required. Extended Temperature Rating: No de-rating in hot climates Grid Scale Energy Storage & Power Conversion Container Solutions (Wind and Solar) Parker delivers standard containers for grid energy storage for wind and solar farms, configured to customer requirements for battery and power conversion: 20 and 40 ISO container configurations Adaptive thermal management, to meet individual configuration demands: Air cooling (HVAC) Two-phase evaporative cooling Hybrid mix of both Hybrid/Electric Industrial Vehicles Agricultural and construction equipment continue to strive for more ways to increase power and fuel economy through electrification and energy storage of key motor functions. These HE motor drives require aggressive thermal management solutions, and Parker is pleased to deliver these benefits: Smaller, more robust cooling systems Up to 40% power higher throughput Safety: Non conductive fluid is inherently safer for: Ultra capacitors Battery modules IGBT modules Greater IGBT reliability and overload protection Fluid requires no freeze protection Ability to cool all electronics on one loop Industrial Power Solutions Medium Voltage Motor Drives and ESP s The high dielectric strength properties of our coolant make Parker s evaporative cooling systems ideally suited for medium voltage motor drive applications, especially considering the reluctance to using water around high voltage electronics. In addition, our electrically isolated fluid interconnect system allows for modular cold plate designs that more easily isolate high voltage circuits. Supports motor drives 1 MW to 4 MW Increased power throughput of 40% or more Higher reliability Field Serviceable Highly modular IGBT cold plate design Data Center Solutions Parker precision cooling systems provide today s stationary and portable data centers with increased processing performance density while reducing overall life cycle costs. Both are achieved through much greater cooling efficiency that air or water cooling. Enabling over 2x rack performance density Higher reliability Reduced energy consumption no chiller or dedicated HVAC required Space savings up to 50% smaller cooling system footprint 20 and 40 container options (up to 350KW per container) 6

2011 Parker Hannifin Corporation PCS 11/11 Parker Hannifin Corporation Precision Cooling Systems 10801 Rose Avenue New Haven, Indiana 46774 phone 509 552 5112 fax 866 851 0660 www.parkerprecisioncooling.com