Sequencing Analysis Software Version 5.1



Similar documents
SUBJECT: New Features in Version 5.3

Instructions for Creating an Outlook Distribution List from an Excel File

Keyboard shortcuts in Excel Keyboard access to the ribbon. In this article WILL MY OLD SHORTCUTS STILL WORK? Hide All

1. Online help for WorkZone Client What's new Getting started with WorkZone Client Working with the user interface 15

Windows XP File Management

Basics of Word Processing

Creating a Web Site with Publisher 2010

Data Analysis Software

User Guide for the Genetic Analysis Lab Information Management System (dnalims)

Introduction to Computers: Session 3 Files, Folders and Windows

Website: Twitter:

Microsoft Word 2010 Tutorial

Digital Pen & USB Flash Drive. User Guide. December

Trace.Net OTDR Test Management Software User s guide

Microsoft Word 2013 Tutorial

SeqScape Software Version 2.5 Comprehensive Analysis Solution for Resequencing Applications

Microsoft Powerpoint 2007 Keyboard Shortcuts

WHAT S NEW IN WORD 2010 & HOW TO CUSTOMIZE IT

Introduction to IMAP with Outlook 2003

ArchestrA Log Viewer User s Guide Invensys Systems, Inc.

Introduction to Outlook Express 6 with IMAP

Livescribe Desktop for Windows User Guide VERSION 2.3.3

Importing Contacts to Outlook

Microsoft Frontpage 2003 Keyboard Shortcuts

Outlook 2007 Keyboard Shortcuts

Appendix A How to create a data-sharing lab

Meyer Sound Remote Monitoring System 4.0

Basics of MS Word :: 137

Microsoft Office Outlook 2013

Outlook 2013 Tips and Tricks Contents

Microsoft Office Outlook 2010 Quick Reference Card

Outlook Web Access. PRECEDED by v\

SMART Ink 1.5. Windows operating systems. Scan the following QR code to view the SMART Ink Help on your smart phone or other mobile device.

Access 2013 Keyboard Shortcuts

MICROSOFT OUTLOOK 2010 READ, ORGANIZE, SEND AND RESPONSE S

PC Agent Quick Start. Open the Agent. Autonomy Connected Backup. Version 8.8. Revision 0

Outlook 2010 Essentials

ArcGIS. Tips and Shortcuts. for Desktop

Vector NTI Advance 11 Quick Start Guide

Using Spreadsheets, Selection Sets, and COGO Controls

Creating a Distribution List from an Excel Spreadsheet

Microsoft Access 2010 handout

GOOGLE DOCS APPLICATION WORK WITH GOOGLE DOCUMENTS

Web Conferencing Loading Content

NDA ISSUE 1 STOCK # CallCenterWorX-Enterprise IMX MAT Quick Reference Guide MAY, NEC America, Inc.

Getting Started with Vision 6

Internet Explorer 7. Getting Started The Internet Explorer Window. Tabs NEW! Working with the Tab Row. Microsoft QUICK Source

Infor ERP BaanIV / Baan 5.0 / LN 6.1. User's Guide for Worktop 2.4

User Guide. For more information us on:

Excel Companion. (Profit Embedded PHD) User's Guide

SQLServer Mgmt Studio 2005 (Std keyset) Keyboard Shortcuts

How to create pop-up menus

Compass Software for Peggy User Guide

Creating a Website with Publisher 2013

Microsoft Outlook 2003 Keyboard Shortcuts

Horizon Patient Folder User s Guide

Microsoft Access 97 Keyboard Shortcuts

How To Use Outlook 2013 For Windows Mail On A Pc Or Mac Or Macbook

Smart Web. User Guide. Amcom Software, Inc.

Junk Settings. Options

PolyU Service. MS Outlook User Manual

Microsoft Outlook 2007 Calendar Features

Word 2007 Unit B: Editing Documents

Beginning Word. Objectives: You will-

Basic File Management & Navigation

Workspaces Creating and Opening Pages Creating Ticker Lists Looking up Ticker Symbols Ticker Sync Groups Market Summary Snap Quote Key Statistics

PREMIUM MAIL A HANDS-ON GUIDE TO MICROSOFT OUTLOOK WEB ACCESS 2003, PART OF THE BIGPOND PREMIUM MAIL PRODUCT SUITE

MICROSOFT OUTLOOK 2010 WORK WITH CONTACTS

Basics. a. Click the arrow to the right of the Options button, and then click Bcc.

Lightworks v12. Quick Start Guide

Microsoft Word Track Changes

Go Kiwi Internet Content Management System Version 5.0 (K5) TRAINING MANUAL

Backup Assistant. User Guide. NEC NEC Unified Solutions, Inc. March 2008 NDA-30282, Revision 6

6. If you want to enter specific formats, click the Format Tab to auto format the information that is entered into the field.

How to create and personalize a PDF portfolio

Outlook Tips & Tricks. Training For Current & New Employees

MS Word 2007 practical notes

Lesson 07: MS ACCESS - Handout. Introduction to database (30 mins)

Education Solutions Development, Inc. APECS Navigation: Business Systems Getting Started Reference Guide

Now part of ALLSCRIPTS. HealthMatics EMR Input Manager

MICROSOFT OFFICE ACCESS NEW FEATURES

NETWORK PRINT MONITOR User Guide

9/4/2012. Objectives Microsoft Word Illustrated. Unit B: Editing Documents. Objectives (continued) Cutting and Pasting Text

Centricity PACS-IW 3.7.3

Windows 8.1 Update 1 Supplement

Word 2010 Introduction

CRM Basic Guide. First, you must login to On the Menu at the left, find the Support menu item.

Getting Started Guide. Trimble Accubid Enterprise Software

Microsoft Outlook Web Access Overview

File Management With Windows Explorer

Quick Reference Guide 3 Outlook 2010 for Windows

Web Intelligence User Guide

You can start almost every task you perform in QuickBooks by clicking something a

Tips Tricks and Techniques for Efficient LabVIEW Development

Getting Started with Access 2007

Word 2007: Basics Learning Guide

Implementing Mission Control in Microsoft Outlook 2010

13 Managing Devices. Your computer is an assembly of many components from different manufacturers. LESSON OBJECTIVES

Transcription:

Applied Biosystems DNA Sequencing Analysis Software Sequencing Analysis Software Version 5.1 The Applied Biosystems DNA Sequencing Analysis Software v5.1 is designed to analyze, display, edit, save, and print sample files generated from Applied Biosystems DNA analyzers and other ABI PRISM genetic analyzers. Features include: Novel basecaller algorithm that performs base calling for pure and mixed base calls Generation of quality values to provide basecall accuracy information for pure and mixed base calls Analysis report to help troubleshoot and provide easy assessment of data quality New Sample Manager interface Optional feature to generate an audit trail of base changes Concepts Used in Sequencing Analysis Software v5.1 Analysis Protocol Contains all the settings necessary for analysis and used to perform basecalling and post processing. Analysis Report Shows the status of the data analysis. The report can be used to help troubleshoot and provide easy assessment of data quality. Clear Range Region of sequence that remains after excluding the low-quality or error-prone sequence at both the 5 and 3 ends. Length of Read (LOR) Measurement of the length of quality bases. The LOR is user definable in the Display Settings dialog box and is displayed in the Analysis report. Quality Values (QVs) Per-base estimate of the base calling accuracy. Sample Score Average quality value of the bases in the clear range sequence for that sample. KB Basecaller New algorithm that calculates mixed or pure bases and quality values. ABI basecaller Algorithm used in Sequencing Analysis software (v3.7 and earlier), which identifies pure bases. Input Sample Files Sequencing Analysis software is compatible with sample files generated from the: Applied Biosystems 3730/3730xl DNA Analyzer ABI PRISM 3700 DNA Analyzer ABI PRISM 3100/3100-Avant Genetic Analyzer ABI PRISM 377 DNA Sequencer ABI PRISM 310 Genetic Analyzer Output Files for Sequencing Analysis Analyzed ABI files (.ab1) Text file of the sequence in ABI or FASTA format (.seq) Phred (.phd.1) files Standard chromatogram format (.scf) files Analysis Report Program Overview Chapter 2 All analysis in Sequencing Analysis software occurs in the Sample Manager. Analysis and review of your samples involve six steps: 1. Add sample(s) to the Sample Manager. 2. Show the sample data. 3. Edit and apply an analysis protocol (optional). 4. Analyze the data. 5. Review overall results and generate an analysis report. 6. Review samples and edit bases. For more information, refer to the chapter or page numbers in the Applied Biosystems DNA Sequencing Analysis Software v5.1 User Guide (P/N 4346366) that are indicated in the blue boxes. QUICK REFERENCE CARD

The Sample Manager The Sample Manager is a window that displays sample files and the various analysis parameter values. All data is analyzed or reanalyzed from this window pane. Single or multiple sample views are displayed here. Processing tasks: Basecalling, Post Processing, Printing Use the Show check box to display sample data Pages 3-5 & 5-2 Analysis parameters can be changed in Sample Manager or in Analysis Protocol. Matrix file used for 310 and 377 data only Calculated results Samples in Sample Manager pane Scroll bar to view other samples Use tabs to view data in Sample Views pane Scroll bars to view a sample Scroll bar to scroll the stack of multiple samples The Analysis Report Chapter 7 An Analysis Report shows the status of data analysis. An analysis report can be generated for any samples added to the Sample Manager. If the data is analyzed, the report displays a summary of QVs and LORs, as well as individual sample information and errors. If the data is unanalyzed, the report displays status information. It can be exported as a tab-delimited file and opened in Microsoft Excel software for trend analysis. Right-click to show/hide a column An underlined sample is hyperlinked to the specific sample in Sample Manager Change view settings here Definition of QV ranges Definition of LOR ranges Partial output and failed samples are hyperlinked to the specific sample in the Errors table Page 2

Data Analysis and Review All analysis in Sequencing Analysis software occurs in the Sample Manager. You can perform the analysis and review of your sequencing sample files by following the steps below. To launch the analysis software, double-click the Sequencing Analysis v5.1 desktop icon. Step 1: Add sample(s) to the Sample Manager. Use the Add Samples function to add samples to the Sample Manager for analysis, printing, viewing, or editing data. 1A. Click (Add Sample). 1B. Select the files that you want to add to the Samples To Add section of the dialog box. To add Do this... Page 3-10 Figure 1 Samples in the Sample Manager view A single file to the list Multiple files All samples in a single folder Select the file, then click Add Selected Samples. Shift-click to select continuous samples or Ctrl-click to select discontinuous samples, then click Add Selected Samples. Select the folder, then click Add Selected Samples. 2B. To show the data in the Sample Navigator, select View > Sample Navigator or click. 1C. Click OK in the Add Samples dialog box. The dialog box closes and the selected files are added to the Sample Manager window. Step 2: Show the sample data. Page 3-13 2A. Use the Sample Manager or Sample Navigator view to show data for one or more sample files. To show the data for Do this... A single sample Double-click the sample file name or select the corresponding Show check box. Figure 2 Samples in the Sample Navigator view Multiple samples Shift-click, Shift-drag or Ctrl-click the sample row numbers to select the sample files, then click. All samples Click the empty box above row number 1 or Shift-drag the sample row numbers to select all samples, then click. Page 3

Step 3: Edit and apply an analysis protocol (optional). Use the Analysis Protocol Manager function to change the analysis protocol settings for samples. 3A. Select the sample rows of interest in the Sample Manager. Use Shift-click to select continuous samples. Use Ctrl-click to select discontinuous samples. 3B. Select Analysis > Analysis Protocol Manager. 3C. In the Analysis Protocol column, select the protocol you want to edit, then double-click the protocol name. 3D. Make changes in the General, Basecalling, Mixed Bases, and Clear Range tabs, as appropriate. 3E. Click OK to save the protocol and close the Sequence Analysis Protocol Editor. 3F. Click: Apply to Selected Samples to apply the protocol to the samples selected in step 3A, or Apply to All Samples to apply the protocol to all the samples in the Sample Manager. IMPORTANT! Do not skip this step. 3G. Click Done to close the Analysis Protocol Manager. Step 4: Analyze the data. Chapter 5 Use to start the basecalling, post processing, and printing tasks that you selected. Click (Start Analysis) and Sequencing Analysis software will automatically perform the following tasks: Basecalling Page 8-13 When the BC (basecalling) parameter is selected, the basecaller performs the either of following tasks: Calls the bases with the KB basecaller If the mixed base option is selected in the analysis protocol, then mixed bases are called. If the mixed base option is not selected, then pure bases are called (A, C, G, and T only). Calculates quality values (QVs) for pure and mixed bases, if the mixed base option is selected. Calls the bases with the ABI basecaller Assigns A, C, G, T, or N to every base (no mixedbase calling and QV options) The Sequencing Analysis software then generates optional file formats (.seq,.phd.1 and/or.scf). Post Processing When the PP (post processing) parameter is selected in the Sample Manager, the software calculates the clear range. Printing When the P (printing) parameter is selected, the software prints the sample views after analysis and post processing. Note: The views that are printed are defined in the Options dialog box. To change the defaults, select Tools > Options, then select the Printing tab. Step 5: Review overall results and generate an analysis report. Use the Sample Manager and the analysis report to review your data. 5A. Review your results in the Sample Manager. a. Look for green, yellow, or red boxes for the BC parameter. Green indicates the process was successful, yellow indicates poor quality data, and red indicates failure. Page 5-8 Note: The yellow result applies only to samples analyzed with the KB basecaller. b. Look for green or red boxes for the PP and/or P parameters. Green indicates the process was successful, and red indicates failure. c. Review the base spacing, peak 1 location, and start and stop points. A red value in the Base Spacing column indicates that the spacing could not be calculated and the default value was used for analysis. Page 5-19 5B. Review the analysis report. Chapter 7 a. Click (Analysis Report) to generate and display the report. b. Review the data in the report. c. To export the report, select File > Export Report. The file is exported in a tab-delimited format. Page 4

Step 6: Review samples and edit bases. 6A. Select a sample file. 6B. Review your results in the sample file: a. Review the raw, analyzed, and EPT data. b. Review low-quality basecalls and check for errors. 6C. Edit the bases, as needed. To navigate through the data, use the keyboard shortcuts in the table in the next column. The QVs change depending on the edits you make. If you: Insert a base No QV is added Delete a base QV is deleted Change a base QV has the same value but is displayed as a gray bar 6D. Save the sample file. The.seq file created when the data was analyzed is updated when you save the sample file. Quality Values The QV is a per-base estimate of the basecaller accuracy. The QVs are calibrated on a scale corresponding to: QV = 10log 10( Pe) where Pe is the probability of error. The KB basecaller generates QVs from 1 to 99. Quality Value Probability the Basecall Is Incorrect 10 10% 20 1% 30 0.1% 40 0.01% 50 0.001% Page 4-2 Page 6-4 Typical high quality pure bases have QVs 20 to 50 Typical high quality mixed bases have QVs 10 to 50 Size and color of QVs bars are identical for QVs 50 to 99 The QVs are optionally displayed as bars above each base in the Sequence and Electropherogram views. The QVs are also displayed in the analysis report. You can change the colors and values of the QV bars in the Display Settings: Chapter 9 1. Select (Display Settings). 2. In the Sample File Display section, change the range for the QVs. Use the two sliders to define the low, medium, and high ranges. QV Bar Low Medium High Figure 3 Default Color and Range Red 0 to 14 Yellow 15 to 19 Blue 20 or higher Display Settings: Bases Tab Set the range to identify data that is Not acceptable Needs manual review Acceptable 3. Click OK to save the new settings and close the dialog box. Shortcuts for Working with Data Use the following shortcuts when working with data in the Sequence and Electropherogram views. Next base To move to the Previous base Next/previous N Next/previous 10 bases Next/previous low QV Next/previous medium QV Next/previous high QV Right arrow Left arrow Press Tab key/shift+tab F5 key/shift+f5 F6 key/shift+f6 F7 key/shift+f7 F8 key/shift+f8 Sliders Page 5

Toolbar The toolbar displays buttons for the most commonly used software functions. See the graphic below for the name, keyboard shortcut, and description of each button. Add Sample(s) Ctrl+I Opens Add Sample(s) dialog box Save All Sample(s) Ctrl+Shift+S Saves changes to all samples Start Analysis Ctrl+R Starts the selected analysis, post processing and printing tasks Remove Sample(s) Delete Removes selected samples from Sample Manager/Navigator Print Ctrl+P Prints selected views and analysis reports View Sequencing Analysis Protocol Ctrl+T Opens analysis protocol for the selected sample Applied Biosystems Home Page Links to the Applied Biosystems web page Save Sample(s) Ctrl+S Saves changes to selected samples Copy Ctrl+C Analysis Report Ctrl+B Generates and displays analysis report Show/Hide QV Ctrl+K Toggles display of the quality values on and off Toggle Ctrl+N Toggles between Sample Navigator and Sample Manager views Zoom In Horizontal Ctrl+= Enlarges view horizontally Zoom Out Vertical Ctrl+Shift+Minus Reduces view vertically Show/Hide Ctrl+U Displays selected sequence file data Actual Size Ctrl+] Restores display to initial default zoom factor Zoom In Vertical Ctrl+Shift+= Enlarges view vertically Show/Hide original sequence Ctrl+J Toggles display of original sequence on and off Full View Ctrl+[ Displays all data in a standard size window Zoom Out Horizontal Ctrl+Minus Reduces view horizontally Display Settings Ctrl+Y Opens Displays Settings dialog box Copyright 2003, Applied Biosystems. All rights reserved. For Research Use Only. Not for use in diagnostic procedures. Applied Biosystems, and ABI PRISM and its Design are registered trademarks, and AB (Design), ABI, and Applera are trademarks of Applera Corporation or its subsidiaries in the U.S. and/or certain other countries. www.appliedbiosystems.com Part Number 4331941 Rev. C