Z-Stacking and Z-Projection using a Scaffold-based 3D Cell Culture Model

Similar documents
Optimizing Performance of the Transcreener ADP Assay for the BioTek Synergy 2 and 4 Multi-Mode Microplate Readers

Cytell Cell Imaging System

Neuro imaging: looking with lasers in the brain

Grow it. Read it. See it. Count it. imaging reader

Measuring Cell Viability/Cytotoxicity: Cell Counting Kit-F

protocol handbook 3D cell culture mimsys G hydrogel

Radius 24-Well Cell Migration Assay (Laminin Coated)

MTT Cell Proliferation Assay

NyONE - Cell imaging in a bird s eye view 4. NyONE...resolution matters! 8. Features & benefits 10. Fluorescence excitation channels 12

Thermo Scientific ArrayScan XTI High Content Analysis Reader. revolutionizing cell biology with the power of high content

Measuring the Point Spread Function of a Fluorescence Microscope

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

Applications of confocal fluorescence microscopy in biological sciences

SmartFlare RNA Detection Probes: Principles, protocols and troubleshooting

Fast Z-stacking 3D Microscopy Extended Depth of Field Autofocus Z Depth Measurement 3D Surface Analysis

Brad Larson and Peter Banks, Applications Department, BioTek Instruments, Inc., Winooski, VT Stephanie Georgiou, Enzo Life Sciences, Farmingdale, NY

CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL

Related topics: Application Note 27 Data Analysis of Tube Formation Assays.

Steatosis Colorimetric Assay Kit

Nucleic Acid Purity Assessment using A 260 /A 280 Ratios

MIRAX SCAN The new way of looking at pathology

MetaMorph Software Basic Analysis Guide The use of measurements and journals

PROTOCOL. Immunocytochemistry (ICC) MATERIALS AND EQUIPMENT REQUIRED

EDF Extended Depth of Field

Application Note. Single Cell PCR Preparation

Chapter 12 Filters for FISH Imaging

Cell Viability You Can Count On

Empower 3D cell culture with simplicity and versatility. VitroGel TM 3D. a ready-to-use hydrogel system for 3D cell culture and beyond

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit

Human Free Testosterone(F-TESTO) ELISA Kit

The How Do Guide to AxioVision. Author: Brian Svedberg Image Analysis Specialist Carl Zeiss MicroImaging, Inc.

Fluorescence Microscopy for an NMR- Biosensor Project

BioResearch. RAFT 3D Cell Culture Kit Protocol

Bio 321 Lightmicroscopy Electronmicrosopy Image Processing

ArC Amine Reactive Compensation Bead Kit

Automation of Cell Staining Technical Information Bulletin

Hidex Sense. Hidex Triathler Multi-technology Microplate Reader. Hidex AMG. Consumables. Hidex 300 SL.

Modulating Glucose Uptake in Skeletal Myotubes:

GASTRIC ORGANOID CULTURE PROTOCOL

Application Note No. 2 / July Quantitative Assessment of Cell Quality, Viability and Proliferation. System

Fluorescent Array Imaging Reader

Advances in scmos Camera Technology Benefit Bio Research

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.

AxioCam HR The Camera that Challenges your Microscope

Optical laser beam scanner lens relay system

Collagen I Self-Assembly: Revealing the Developing Structures that Generate Turbidity. Supporting Material

Outline. 1. Experiment. 2. Sample analysis and storage. 3. Image analysis and presenting data. 4. Probemaker

Image Analysis Using the Aperio ScanScope

Refractive index of extracellular vesicles by nanoparticle tracking analysis

Zeiss 780 Training Notes

Western Blot Analysis with Cell Samples Grown in Channel-µ-Slides

Seahorse XF Cell Mito Stress Test Kit

ab Protein Sumoylation Assay Ultra Kit

BACTERIAL ENUMERATION

Optical mesoscopy with a new giant lens. Gail McConnell, Johanna Tragardh, John Dempster & Brad Amos

Coherence-controlled holographic microscopy for live-cell QPI

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Hydrogen Peroxide Cell-Based Assay Kit

Software-based three dimensional reconstructions and enhancements of focal depth in microphotographic images

Super Resolution Optical Microscopy. Bo Huang

Cell Migration, Chemotaxis and Invasion Assay Protocol

Zeiss Axioimager M2 microscope for stereoscopic analysis.

Comparison of Trypan Blue and Fluorescence-Based Viability Detection Methods Via Morphological Observation

Quick Guide to AlphaScreen SureFire Assay Optimization

Cell Viability Measurement

Near-field scanning optical microscopy (SNOM)

THE COMPOUND MICROSCOPE

Labeling and Detection. The best and brightest Alexa Fluor dyes

INSTRUCTION Probemaker

Automotive Applications of 3D Laser Scanning Introduction

Improved predictive modeling of white LEDs with accurate luminescence simulation and practical inputs

Cell Phone Radiation Effects on Cancer. Tyler Barkich Central Catholic High School Grade 11

CytoSelect 48-Well Cell Adhesion Assay (ECM Array, Fluorometric Format)

full library phenotypic screening without compromise

Evaporation-based Microfluidic Production of. Oil-free Cell-Containing Hydrogel Particles

TransIT Transfection Reagent

1536-well FLIPR:A Possibility or Probability? Or, How I spent last week! Gary Allenby AstraZeneca Lead Generation, Charnwood, U.K.

BD Pathway Bioimaging Systems

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required.

Rat Creatine Kinase MB Isoenzyme (CKMB) ELISA

Transfection reagent for visualizing lipofection with DNA. For ordering information, MSDS, publications and application notes see

Leica TCS SP5 Confocal Laser Scanning Microscope User Guide 1. BASIC IMAGE ACQUISITION

Cell Cycle Phase Determination Kit

The Olympus stereology system. The Computer Assisted Stereological Toolbox

MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

ZEISS Microscopy Course Catalog

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

Operating Manual for UVEX-p (JAN Scientific, Inc. Aug 2014)

Meso Scale Discovery. WINDOWS is a registered trademark of Microsoft Corporation

Light Control and Efficacy using Light Guides and Diffusers

P4 Distribution of Cetuximab in Models of Human Lung Cancer

Transcription:

A p p l i c a t i o n N o t e Z-Stacking and Z-Projection using a Scaffold-based 3D Cell Culture Model Brad Larson and Peter Banks, BioTek Instruments, Inc., Winooski, VT Grant Cameron, TAP Biosystems (part of Sartorius Stedim Biotech Group), Hertfordshire, UK Introduction Key Words: 3D 3D Cell Culture Z-Stacking Z-Projection Deconvolution RAFT Tumoroid Imaging Microscopy Cellular Analysis BioTek Instruments, Inc. P.O. Box 998, Highland Park, Winooski, Vermont 05404-0998 USA Phone: 888-451-5171 Outside the USA: 802-655-4740 Email: customercare@biotek.com www.biotek.com Copyright 2015 Z-projection is a digital image processing method, which combines multiple images taken at different focal distances (z-stacking) to provide a composite image with a greater depth of field (i.e. the thickness of the plane of focus) than any of the individual source images 1,2. It is particularly useful for capturing in-focus images of objects under high magnification as depth of field (DOF) decreases with magnification primarily because microscope objectives with higher magnification have typically higher numerical apertures (NA). According to the Shillaber equation, DOF relates to NA for a given wavelength of light (λ) and medium refractive index (n): Table 1 illustrates this concept for a series of commercially available microscope objectives using 500 nm light and air as the medium (n = 1.00) between microscope objective and object. Magnification Numerical Aperture Depth of Field (µm) 4x 0.10 50 10x 0.25 7.7 20x 0.40 2.9 40x 0.65 0.9 60x 0.85 0.36 100x 0.95 0.17 Table 1. Relationship between magnification, numerical aperture and depth of field. Note that the dimensions of a typical mammalian cell (~ 25 µm) is only within the depth of field (in focus axially) using a 4x microscope objective. Magnification of 4x is inadequate to provide sub-cellular resolution in either axial or longitudinal axes, thus localization of structures of interest within the cell through its width requires use of higher magnification and means of removing out of focus objects. This can be done using confocal microscopy where the field of view is restricted both axially and longitudinally, much like in a pin hole camera, such that in-focus slices of the object can be acquired and z-stacked to form a composite 3D image of the object. However, because the excitation light illuminates the entire structure, photobleaching and phototoxic effects extend to all planes. While the lack of longitudinal restriction seen in widefield microscopy helps to eliminate these complications, parts of the object will appear in-focus and parts out-of-focus. In this case, z-stacking is still possible, but requires the use of z-projection, a technique to reduce out-of-focus information by applying a mathematical algorithm. This provides sharper images that can be combined to yield more realistic 3D impressions of the structure of interest. In this application note, we demonstrate this technique using Gen5 Image+ Data Analysis Software to perform z-stacking and z-projection of scaffoldbased 3D cellular tumoroid structure images. Materials and Methods Materials Cells Colorectal carcinoma HCT 116 cells (Catalog No. CCL-247) were obtained from ATCC (Manassas, VA). The cells were propagated in McCoy s 5A Medium (Catalog No. 16600) plus Fetal Bovine Serum, 10% (Catalog No. 10437) and Pen-Strep, 1x (Catalog No. 15140) from Life Technologies (Carlsbad, CA). The cells were plated at a final density of 2.5x10 5 cells/ml for 72 hours prior to performing the assay.

Fluorescent Probes 3D Cell Culture Components Hoechst 33342 (Catalog No. 14533) was purchased from Sigma-Aldrich Corporation (Saint Louis, MO). Alexa Fluor 488 phalloidin (Catalog No. A12379), and CellMask Orange plasma membrane stain (Catalog No. C10045) were purchased from Life Technologies (Carlsbad, CA). RAFT Reagents and Plates 96-well RAFT Plate and 96 -well Culture Plate are part of the 4 x 96 RAFT Plate Kit (Catalog No. 016-0R92). Collagen Solution, 10x Minimum Essential Medium, and RAFT Neutralising Solution are part of the RAFT Reagent Kit (Catalog No. 016-0R94). All RAFT components were supplied by TAP Biosystems (Hertfordshire, UK), now exclusively distributed by Lonza BioScience. RAFT 3D Cell Culture System D. Instrumentation Cytation 5 Cell Imaging Multi-Mode Reader Cytation 5 is a modular multi-mode microplate reader that combines automated digital microscopy and microplate detection. Cytation 5 includes filterand monochromator-based microplate reading; the microscopy module provides high resolution microscopy in fluorescence, brightfield, color brightfield and phase contrast. Cytation 5 has temperature control to 65 C, CO 2 / O 2 gas control and dual injectors for kinetic assays. The instrument was used to image spheroids, as well as individual cell invasion through the Matrigel matrix. Gen5 Image+ Data Analysis Software Gen5 Image+ software controls the operation of the Cytation 5 for both automated digital microscopy and microplate reading. Image acquisition is completely automated from sample translation, focusing and exposure control. Users can also optimize and automate acquisition of images through 3D cellular structures or tissue, as well as creation of the final Z-Projection. E. Figure 1. Creation of 3-Dimensional Cell/Collagen Hydrogel using RAFT System. (A) Cell/collagen mix dispensed to wells of 96-well plate. (B) 96-well RAFT plate containing individual sterile absorbers. (C) Absorber insertion into plate well. (D) Absorption of medium, concentrating collagen and cells to in vivo strength. (E) Completion of absorption process creating 120 µm thick hydrogel. (F) Removal of absorber prior to dispense of fresh cell medium. The RAFT (Real Architecture for 3D Tissue) cell culture technique developed by TAP Biosystems, now exclusively distributed by Lonza BioScience, allows researchers to culture cell type(s) of their choice in an in vivo like collagen hydrogel environment. The technology uses the most abundant matrix protein in the body, type I collagen. The RAFT process raises the collagen concentration to physiological levels quickly and reproducibly. It takes less than 1 hour to generate cell cultures which are ~120μm thick, biomimetic, dimensionally stable and transparent with high cell viability. F. 2

Methods 3D Tumoroid Formation Process Day 1 HCT116 cells were added manually to the prepared collagen solution. The cell suspension was then dispensed to the 96-well plate in a volume of 240 μl per well. The final cell concentration equaled 25,000 cells/ well. The cell plate was then incubated at 37 o C/5% CO 2 for 15 minutes, followed by manual addition of the absorbers in the RAFT plate, and an additional 15 minute incubation at 37 o C/5% CO 2 during which the RAFT process increases the collagen density to a physiologically relevant strength. The absorbers were then removed and 100 μl of new medium was then added to the concentrated cell/collagen hydrogel. The plate was once again incubated at 37 o C/5% CO 2 for three days to allow the tumoroids to form. Day 4 Following the incubation period, the spent medium was removed and the tumoroids were stained with the Hoechst 33342, Alexa Fluor 488 phalloidin, and CellMask Orange plasma membrane fluorescent probes. To determine the sample thickness and number of slices required to image through the complete structure, it is recommended to select manual imaging with one of the channels to be used. Auto Focus is selected to allow the Cytation to focus on a point within the structure. The focal height is then changed manually in each direction of the z-axis to the point where a portion of the spheroid or tissue remains in focus (Figure 3). Creation of Z-Stacked Images In the imaging procedure read step, selection of objective, imaging channel and exposure settings is performed in a manner similar to that for single image set capture. Image Z-Stack is then selected (Figure 2). The number of slices, or images taken through the structure can be manually chosen depending on the definition desired. Step size is the distance in µm that the objective will move in the z-axis between each captured image. The default value is the depth of field for the objective chosen, 2.5x: 68 µm; 4x: 53 µm; 10x: 9 µm; 20x: 4 µm; 40x: 2 µm; 60x: 1 µm, which can also be manually adjusted should a higher number of slices be desired. Figure 3. Manual Determination of Sample Thickness. Object thickness determined by finding () bottom and () top focal planes using manual imaging. The total distance traveled from one point to the other is the sample thickness. This process is repeated to determine the typical focal height and distance traveled above and below the initial focal plane to reach each edge of the structure. Upon completion, manual imaging can then be closed. Using the gathered information, values are entered into the read step for Number of slices, Step size, and Images below focus point that equal the typical sample thickness, and also help to ensure that images are captured throughout the 3D cellular structure or tissue (Figure 2). Automated imaging can then be performed. Z-Projection Creation 3 Figure 2. Gen5 Image+ Z-Stack Read Step. Following capture of the z-stacked images, z-projection can be completed by performing a Z-Projection Data Reduction step (Figure 4). Individual imaging channels can be chosen for inclusion in the projected image. The top and bottom image slices to use can be optimized to guarantee that the most in-focus image is created. Multiple projection methods exist which incorporate different algorithms for selecting the most in-focus portion of the z-stacked images. The method providing the desired projection may vary depending on the images captured and the final analysis required.

Figure 4. Setup of Z-Projection Analysis. If additional imaging channels are to be included in the projection (Figure 5), subsequent channel tabs can be selected. The parameters can be kept consistent with those used for the initial channel (Figure 5A), or can also be changed if necessary (Figure 5B). Figure 5. Subsequent Imaging Channel Z-Projection Optimization. Settings for additional imaging channels to be included in Z-Projection can be kept similar to that of () Channel 1 or () reoptimized. Results and Discussion 4 Tumoroid Image Deconvolution and Cellular Analysis The cells in the aggregated three dimensional tumoroid structures can be found on multiple z-planes within the RAFT hydrogel. Experimental analysis of the effects that a potential drug candidate has on these structures, depending on the assay and test being performed, can at times be accomplished using single plane imaging. However, this is not always the case, and a final image showing improved cellular definition may be necessary. Upon visualization of the images displayed in Figure 6, it was apparent that the z-projection of the z-stack (Figure 6D) allowed the cells to be seen with more detail and greater clarity in each tumoroid structure compared to the single plane images (Figures 6A-C).

Application Note D. Figure 6. Single Plane and Z-Stacked Images of HCT116 Tumoroids. Images of tumoroids captured at individual z-planes of () 3446, () 3470, and () 3486 µm using a 20x objective. (D.) Final z-projected image of the collected z-stack. Image overlay shown using the following channels: DAPI for identification of Hoechst 33342 stained nuclei; GFP for identification of Alexa Fluor 488 phalloidin; Texas Red for identification of CellMask Orange plasma membrane stain. Cellular analysis of 3D cellular structures can also be improved through the incorporation of a z-projected image. A clear picture of individual nuclei (Figure 7A) then allows for more precise conclusions to be drawn (Figure 7B) from the experiment being performed. Figure 7. HCT116 tumoroid cellular analysis. (A) Z-stacked image of Hoechst 33342 stained nuclei, and (B) cell count performed using optimized analysis settings. 5 Conclusions References 3D cellular models continue to be incorporated into a growing number of research areas; including dermatology and drug discovery. Here we have shown that the Cytation imagers, in conjunction with Gen5 Image Analysis Software, can provide improved depth of fields of cells aggregated into tumoroid structures within the RAFT hydrogel in a rapid, automated fashion, while providing accurate evaluation and conclusions from z-projected images. 1. Johnson, D. How to Do Everything: Digital Camera [Online]; McGraw Hill Professional: New York, 2008; 336. http://books.google.com/books?id=h15xmx3m a2cc&q=inauthor:%22dave+johnson%22&dq=inaut hor:%22dave+johnson%22&hl=en&sa=x&ei=ihdcu sj_hm_okaeulohqba&ved=0cgkq6aewca (accessed October 14, 2013). 2. Ray, S. F. Applied Photographic Optics, 3rd Edition; Focal Press: Oxford, 2002, 231-232. Alexa Fluor is a registered trademark of Molecular Probes Inc. AN050715_06, Rev. 05/07/15