USER S MANUAL HSC-24A



Similar documents
Portable Air Conditioner

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Dehumidifier Users manual. For Models: DH45S DH65S

Use and Care Manual. Model CPA12KH AIR CONDITIONER

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

PORTABLE AIR CONDITIONER

Split Type Room Air Conditioner. KSWM units

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Instruction manual for Firstline FCS12000CH

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

REMOTE CONTROL MANUAL

PORTABLE AIR CONDITIONER

Meaco 30L and Meaco 40L dehumidifier instruction manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Operating Instructions Split System Air Conditioner

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Air Conditioner. Portable BTU/h 2.9kW INSTRUCTION MANUAL CWAC11 CPIN Important! Please read these instructions carefully.

Owner s Manual RBC-AMS41E. Remote controller with weekly timer. Owner s Manual

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t.

Room Air Conditioners

Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2

evo + HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER S MANUAL Models: GWH09AB-D3DNA2D GWH18AC-D3DNA2D GWH24AC-D3DNA2D

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

Single Zone LCD Thermostat Operating Instructions

Portable Air Conditioner

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex

Important Safeguards

WINDOW ROOM AIR CONDITIONER

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

Get Me Cool Now Portable Air Conditioner User s Manual

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Failure code manual. content

FOXAIR 60/50 ALL MODELS

OWNER S MANUAL SPLIT SYSTEM AIR CONDITIONER. G Series Cooling

Operating Instructions Air Conditioner

Dehumidifier D 850E. - Instruction manual version 02

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

OPTIONAL SLENDER REMOTE CONTROL

MovinCool Office Pro Series. The Portable Spot Cooling Solution

HEAT RECOVERY VENTILATORS MODELS 90H-V ECM HRV, 90H-V+, 60H-V+ AND ENERGY RECOVERY VENTILATOR MODEL 90H-V ECM ERV

Before using your air conditioner, please read this manual carefully and keep it for future reference. ROOM AIR CONDITIONER

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

SWIMMING POOL HEAT PUMP

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Operating Instructions Air Conditioner

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

AIR CONDITIONER (SPLIT TYPE)

Inverter Single Zone Ductless Mini Split Heat Pump

Room Air Conditioners

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

PORTABLE AIR CONDITIONER (LOCAL)

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

Contents. Correct Disposal of This Product (Waste Electrical & Electronic Equipment)

FTXS. Wall Mount Heat Pump or Cooling Only

R410A SPLIT SERIES DC INVERTER

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

DUCT TYPE AIR CONDITIONER

OPERATING & MAINTENANCE MANUAL. Packaged Terminal Air Conditioner (PTAC) World Class Comfort.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER

OMI-09/OMO-09 OMI-12/OMO-12 OMI-18/OMO-18 OMI-24/OMO-24. Wall Mounted Unit

Split Air Conditioner

AIR CONDITIONER INSTALLATION MANUAL

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Features of your Air to water heat pump

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Climax Air Inc. DC Inverter Portable Air Conditioner Model VS12 12,000 BTU Introducing The World s Most Efficient Portable Air Conditioner

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

INDOOR UNIT/OUTDOOR UNIT

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Taurus Series YORK Window Air Conditioners

Ceiling Mount Air Handler Manual

Safety, Operation and Maintenance Manual with Parts List

Quest 105, Dry155, and 205 Dual

Platinum Range PLAC12000HP PORTABLE AIR CONDITIONER WITH HEAT PUMP USER MANUAL HIGH MID COLL HEAT DRY FAN LOW F C TIMER SLEEP SWING

Reverse Cycle Inverter Split System Air Conditioner

Transcription:

AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL that you read the NOTES ON SAFETY carefully before use and follow them at all times. The Air Conditioners are specified for use on a 115V. 60Hz.1ph for models HSC-14/18/24, and 220V. 60Hz. 1ph for model HSC-24A single phase power supply. You must check that the local electricity supply is the same and have the appropriate plug fitted by a qualified electrician. The Warranty form is on Page 15. Please complete it now and keep in a safe place. We have a policy of continual improving to our products. The contents (features and specifications) in this manual are therefore subject to change without notice. NOZZLE TYPE LOUVER TYPE

TABLE OF CONTENTS SAFETY INSTRUCTIONS DESCRIPTION Front View Back View Control Panel OPERATING INSTRUCTIONS On/Off Operation Selection of Area/Room or Spot Cooling Economic Mode Temperature Control Off Timer Indicator and Operational Error Alerts CLEANING AND MAINTENANCE TROUBLE SHOOTING / ACCESSORIES SPECIFICATIONS WARRANTY 3 5 5 5 6 7 7 8 8 9 10 11 12 13 14 15 2

SAFETY INSTRUCTIONS The following instructions are for ensuring the user s safety and to prevent any physical injury or material damage. Please read carefully and follow all instructions. There are two sections to these instructions: WARNING and CAUTION. The following symbols are for your guidance: = You must NOT. = You MUST. WARNING Use a 115V. 60Hz.(HSC-14/18/24), 220V. 60Hz(HSC-24A) 1 Phase power supply only. (Wrong supply may cause a fire and / or shock hazard) Securely plug into an grounded outlet. (Unless earthed, may cause electric shock) Do not use a damaged power cable, plug or socket. (Short, fire or shock hazard) Do not remove plug by pulling cable or with wet hands. (Risk of fire and electric shock) Before cleaning, remove plug from socket. (Otherwise risk of electric shock) Do not place anything on top of the machine. (This could cause electric shock, malfunction or injury) Do not use an extension cord. (Risk of fire and / or electric shock) Ensure mains plug is clean and securely plugged in. (Otherwise it may short causing smoke and fire) Do not kink or sharply bend the power cable nor put any weight on it. (The insulation may be damaged causing fire and/ or electric shock) Do not turn off by removing power plug. Always turn off at control panel first. (Risk of electric shock and / or malfunction) Do not use this cooler on unstable or inclined surfaces. Always use on solid flat floor. (Risk of falling causing injury, fire or malfunction) A damaged power supply cable must be replaced with a new power supply cord obtained from the product manufacturer and not repaired. Keep this manual in a visible location near the cooler for easy reference. 3

SAFETY NOTICE CAUTION Do not place cooler on uneven, unstable or inclined surface. (This could cause malfunction) When storing the cooler, ensure that it is kept in a dry, cool place. (To prevent corrosion and malfunction) If not being used for some time or if lightening is present, always unplug from power. (To prevent risk of electric shock, short circuit or fire) Do not spray water on to the cooler nor use solvents such as benzene, thinner or alcohol for cleaning. (There is a risk of electric shock and / or short circuit) Designed for indoor usage. GENERAL ADVICE BEFORE USE Ensure the safety of the location in which cooler is to be used. Ensure the floor or ground is smooth and sound. Ensure you allow at least 20inch air space all around the cooler. When in position LOCK the casters to prevent rolling. Never use the cooler at more than 2 incline. FOR MAXIMUM EFFICIENCY In airtight areas use vertical exhaust into ceiling. If possible locate exhaust outlet through a window or door to outside. Exhaust ducting should be no longer than 6.6 ft. for maximum efficiency. Ensure correct electricity supply. DUCT INSTALLATION The duct should be established before using. (Duct length : minimum 1ft) 4

EXTERIOR DESCRIPTION FRONT VIEW FLEXIBLE DUCT OUTLET (COLD AIR) HANDLE DIGITAL CONTROLLER ELECTRIC PANEL (ACCESS BY AUTHORISED SERVICE PERSONNEL ONLY) POWER PLUG CASTERS (FRONT LOCKABLE) BACK VIEW CONDENSER OUTLET (HOT AIR) EVAPORATOR FILTER AMBIENT AIR INTAKE. CONDENSER FILTER WATER LEVEL INDICATOR TO CHECK WATER LEVEL OF THE CONDENSATE TANK. CONDENSED WATER TANK TO COLLECT WATER GENERATED DURING COOLING. 5

CONTROL PANEL FUNCTIONS 7 10 8 9 11 12 3 4 5 6 13 2 1 1 Power : Use to power On / Off. 2 : Raises or lowers temperature and/ or sleep (off) time. 3 Cool : Use to select cooling mode. 4 Low Mode : Controls fan low speed. 5 High Mode : Controls fan high speed. 6 Off Timer : To set the length of time, once turned on, that you wish the cooler to run for. You can set 0~24 hours. Time intervals are 30mins. up to 10 hours and then 1 hour between 10 and 24 hours. 7 Remote : From the long distance, you can control the machine by wired remote control. 8 Room : If the LED is On, the displayed temperature is for Room temp. If the LED is Off, the displayed temperature is for spot temp. 9 Comp. : When the compressor is operating, the LED is On. 10 Error : Error signal ( E1 : High Pressure, E2 : Low Pressure, E3 : Sensor, AF: Eva Freezing) 11 Water Full: Red light indicates Tank Full. The compressor will shut off automatically. Empty tank and replace in position to resume operation. 12 Align Drain Tank : The red light indicates the water tank is not in the correct position. 13 Display : Display Room/Spot temperature, the setting temp and sleep time in case of setting them. When the user set the sleep timer, hr will be turned on. (Display of 'LO' : under the 32, Display of 'HI' : over the 99 ) 6

OPERATION RUNNING & STOP 1. START BY PRESSING THE POWER BUTTON. Cooler will start up automatically. To STOP the unit, press the POWER button once again. 2.To change fan speed, press the Low button. 3.If you wish to operate on fan only, press the COOL button. To resume cooling, press the COOL button again. (Note : There is a 3 minute delay when switching functions to protect the compressor) 7

SELECTION of AREA/ROOM or SPOT COOLING To reduce the temperature of the entire room select 'Area/Room'. For targeted cooling of machinery, servers, or people etc. select Spot Cooling. 1. If you want to display room temperature, push cool and button simultaneously for three seconds. 2. If you want to change temperature unit, push and button simultaneously for three seconds. ECONOMIC MODE If the compressor operation is stop in "Room Temp Mode", the Fan motor operation also is stop in 3min. later. In Room Temp Mode, If you want to go "Economic Mode", Push Low fan (or High fan) button continuously for 3 seconds. 1. or 2. If the Economic mode is effective, Room Mode LED is bilnk. 8

TEMPERATURE CONTROL OPERATION 1. When power is ON, the setting temperature is displayed. Default of setting temperature is as below. 50 in Spot Mode. 60 in Room Mode. 2. When you push either or button, the setting temperature is changed. 3. The display showing the set temperature will blink 3 times. 4. Display range & Setting range. Mode Display range Setting range Room Temp 32 ~99 60 ~86 Spot Temp 32 ~99 50 ~86 Cooling operates when Room/Spot temperature is more than set temperature. Cooling stops when Room/Spot temperature is less than set temperature. 9

HOW TO SET THE OFF TIMER. This function enables you to set the length of time you want the cooler to operate. You can set the time period from 30min. to 24 hours in 30min. and 1 hour increments. 1. When cooler is operating, press the Off Timer button and set the length of time you want by pressing or. Each time you press the button you will increase the time to off period by 30mins. up to 10 hours, and 1 hour thereafter up to 24 hours. The display will show.5 for 30min and 1 for an hour. e.g. One and a half hours will show 1.5. 2. When you have finished setting the time period, the Off Timer lamp will be on which indicates the cooler is in sleep (Off Timer) mode. OFF TIMER LAMP IS ON 3. If you press the Off Timer button during its operation, the remaining time will be shown. AFTER 1hr 4. To CANCEL timing, press Off Timer button for ONE second. It will then switch the timer off automatically. 10

'ERROR' and WARNING INDICATORS The machine s safety devices will automatically signal any problems via the display window on the control panel. The information below shows how to read these signals. 1. WATER FULL- Display shows FU When the water container is full, FU is displayed and the LED Water Full light will be on. 2. ALIGN WATER TANK If the water tank is not positioned correctly, the LED Align Drain Tank light will be on. 3. HIGH PRESSURE E1 is displayed and the Error LED will be on when the pressure of the compressor is too high and the high pressure switch is open. 4. LOW PRESSURE E2 is displayed and the Error LED will be on when the pressure of the compressor is too low. 5. SENSOR PROBLEM If the thermistor is short circuited or cut, E3 is displayed and the Error LED will be on. 6. ANTI FREEZING When the temperature of the evaporator is below 28, AF is displayed and the Error LED will be on. 11

CLEANING AND MAINTENANCE CLEANING THE AIR FILTERS 1. To remove filters, slide up a little 1 and pull towards you 2. 2. Clean the filters with water or compressed air. 3. Clean evaporator and condenser units with a vacuum cleaner or compressed air. MAINTENANCE 1. After cleaning, completely dry the inside of the unit by operating on Fan Mode only for 3 to 4 hours. 2. Turn OFF at control panel, remove plug from socket. Coil and store cable neatly. 3. Keep machine suitably covered to prevent damage by damp, humidity and dust. 12

TROBULE SHOOTING TROUBLE CHECK REMEDY NOT WORKING Power plug correctly connected POWER button OFF Blown fuse in electric panel Fuse (supply) blown Breaker on switch board tripped Connect plug correctly Press POWER button to ON Replace fuse Exchange fuse in board Check load capacity and reset Ambient temp. too high Use only below 105 (over 105 ) POOR COOLING Filter blocked with dust Dust in heat exchanger Obstacle against inlet side Clean Filter Clean heat exchanger Remove and allow 20inch.clearance Ambient temp. too high Use only below 105 (over 105 ) ACCESSORIES ITEM MODEL HSC-14/18/24/24A DRAWING DUCT Diam. 5inch 12inch 9.8 ft. OPTION Nozzle type COLD AIR OUTLET DUCT COVER (FINISHING COLLAR) DAMPER BASE (FLOW CONTROL FLAP) ALUMINIUM FILTER CASSETTE Nozzle type Louver type HOT AIR EXHAUST ALUMINIUM FILTER CASSETTE 13

SPECIFICATIONS Cooling Capacity Power Supply BTU/h kw HSC-24A 23,500 (6.89) 220Va.c. 60Hz. 1Ph. Dimensions (WxDxH) inch. 19.3 X 23.6 X 51.3 Weight lb 210 Evaporator Air Flow ft 3 /m 460 Power Consumption kw 2.75 Current Consumption Amp. 12.5 Nema Plug 6-20 Refrigerant lb R-410A, 2.97 Air Filter Safety Devices Aluminium Mesh Cartridge High Pressure Switch Fan motor protection Low Pressure Switch Tank position indicator. Auto Full Tank shut off. 3 min. delay timer. Thermostat and relief valve for compressor Power Cable DEVICE Length Plug 9.8 ft. Operating Range 72 DB 60% RH ~ 105 DB 40% High Pressure kgf/cm 2 /psig 31/455.7 Low Pressure kgf/cm 2 /psig 13/191.1 Max. Duct Length (Either hot or cold, not both together in use) Cold Duct Hot Duct 30 ft. (Nozzle Type Only) 32.8 ft. Fuse in power box in Machine body 250Va.c. 5amp. 14

WARRANTY (Applicable to first retail purchaser only) AIRREX AIR CONDITIONERS give more reliable performance, comfort and durability the more they are used. They are built under a strict quality assurance regime which includes inspection both during and after production and exhaustive reliability testing. In the unlikely event you have any problems, please contact your dealer or distributor. If the problem is as a result of a production fault or failure, repairs will be undertaken free of charge during the period of warranty subject to the following warranty conditions: 1. The warranty period is 12 months from the date of first purchase. 2. If the problem has been caused by customer error or misuse, abuse or damage, then all repairs will be charged for. 3. This warranty applies to your country. 4. Proof and date of purchase must be supplied. 5. Please complete the details below and keep this warranty in a safe place. 6. All transport charges back to the dealer are at the customers cost. Keep all original packaging to facilitate return. Return to customer will be at dealers cost (if genuine warranty claim). DESCRIPTION MODEL DATE OF PURCHASE AIRREX AIR CONDITIONER HSC-24A PRODUCT SERIAL NO: Warranty Period ( ) Months DISTRIBUTOR Name of Company Telephone No. CUSTOMER DETAILS Name : Address : Telephone : 15

USA DISTRIBUTOR AIRREX USA P.O BOX 340 HEWITT, TEXAS 76643 TEL : 1-888-244-5898 FAX : 1-469-574-7924 sales@airrexusa.com HEPHZIBAH CO.,LTD. 1385-15 JUAN-DONG, NAM-GU INCHEON, KOREA TEL : +82-32-509-5834 FAX : +82-32-502-5519 E-mail : airrex@hdtek.com Website : www.airrex.co.kr Designs and specifications of products are subject to change without prior notice for the improvement of products.