Better Boilers. www.ibcboiler.com

Similar documents
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

Commercial Boiler Systems and Controls

Commercial Gas Water Heaters

Commercial Gas Water Heaters

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

ASME Packaged Indirect Fired Water Heater

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

Cast-Iron Performance Meeting today s commercial demands with effi ciency, strength and intelligent controls.

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

NAVIEN AMERICA INC FITCH AVENUE

Light Duty Commercial Electric Water Heater

Commercial Gas Water Heaters

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

G234X-55 Conventional Gas Boiler

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

TANKLESS DURABILITY Tankless Product Guide

Cooling Capacity CFM in. w.c. (125 Pa)

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

Electric Flow Boiler

SOLI TANKLESS PRODUCT GUIDE

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR

Cooling Capacity CFM in. w.c. (125 Pa)

SPIDERfire: Delivers high efficiency and real savings for today s businesses

Cooling Capacity CFM in. w.c. (125 Pa)

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Versatility ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO.

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

RECON WATER HEATER INSTALLATION FORM

Commercial Gas Water Heater

High efficiency, cast-iron gas boiler

Commercial Semi-Instantaneous Water Heaters

Cased/Uncased Coils For Gas And Oil Furnaces

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

REGULATORS 175/153 Series

Commercial Electric Water Heater

Nirvana. Cycling Refrigerated Dryers

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Navien Condensing 98% Tankless Water Heaters. Tankless Water Heaters. Navien Condensing. The Ultimate in Energy Efficiency with Hi-Tech Comfort

HEAVY DUTY STORAGE GAS

Y-200 Multi-Stage Sequencer

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

DESIGNER S HIGH EFFICIENCY GUIDE SYNC COMMERCIAL BOILERS. Up to 98% Thermal Efficiency.

F9MXE. Product Specifications

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

MAC-120HE-01 Air-Cooled Chiller

Commercial Gas Furnace Upflow

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

Hot Water Makers. Efficiency at its Best

Vitodens 200, B2HA / B2HB - Product Introduction

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

FLASH TANK ECONOMIZER PRODUCT GUIDE

SIOUX HYBRID WATER HEATER

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

Maximizing Boiler Plant Efficiency. Presenter: Dan Watkins, LEED BD+C Sales Engineer Bornquist, Inc.

Therm-Omega-Tech, Inc. Therm-Omega-Tech, Inc. MODEL EMV. A Heavy Duty, Reliable Source For Tepid Water Delivery. Model EMV

ECOCIAT. Domestic hot water heat recovery unit

Commercial Electric Water Heater

presents Hydraulic Separation Beyond Primary / Secondary Piping

Originators of the Flexible Water Tube design

GTS. New! Plus: PR0DUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. New models GTS-500 and GTS-700. Gas-to-Steam Humidification System

Technical Data Manual Model Nos. and pricing: see Price List

THERM Tankless Water Heaters. Applications Manual

CoolTeg Plus Chilled Water (CW) version: AC-TCW

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Condensing Boiler Efficiency

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.

G9MXE. Product Specifications

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Natural geothermal energy.

Morrison Bros. Co. General Product Specifications

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

STATE SUPER HIGH EFFICIENCY Up To 96% Thermal RESIDENTIAL PREMIER POWER-VENT MODELS

GTS Gas-to-Steam Humidification System

Principals of Condensing Boiler System Design

Tankless water heaters

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

Heating, air-conditioning, cooling

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Mega-Stor INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS

Heating Cable. Construction

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Electric & Gas Water Heaters

Modern Gas Heating. The Vitodens 200 gas-fired condensing boiler is prepared for the use of conditioned biogas.

RPV - RP - RA air handling units

Transcription:

Better Boilers

FEATURING OUR IBC SUPREME SUPER COIL 316TI STAINLESS STEEL HEAT EXCHANGER. From the factory in Vancouver, our uniquely designed and engineered Super Coil VFC Heat Exchanger is the best Heat Exchanger ever made. With more than 16 years of production excellence, utilizing the latest advances in burner, gas/air mixing and control technology the Super Coil delivers the lowest flue gas exhaust temperature / return water temperature differential.

VFC 15-150 15,000 to 150,000 BTU/H VFC 45-225 45,000 to 225,000 BTU/H PREMIER CONDENSING BOILERS New Touch Screen Boiler Controller Express setup Remote monitoring & diagnostics Easy USB programmability True native BACnet Intuitive alert system Easy homeowner DHW temp adjust VFC 15-150 became the first and industry leading 10:1 turndown ratio residential-scale modulating boiler in North America. Spanning the range from small cottage to sprawling mansion. Sustained high efficiency across firing range even at high temperatures. Now featuring multiple zone pump control - up to 4 zones. Replacing the need for external pump controls. MFZ Technology: Patented moisture management system. Protects and ensures long life for all components in the boiler. Unmatched durability from our exclusive 316Ti stainless steel 80psi Super Coil heat exchanger. Control 5 independent pumps directly from the boiler without additional relays. Go anywhere venting options up to 480 feet! IBC boilers are not de-rated because of longer vent runs. Better efficiency 95% AFUE. Limited lifetime residential heat exchanger warranty. See website for details. Limited 5 year parts warranty. See website for details. H Specifications VFC 15-150 VFC 45-225 CSA Input (Natural Gas or Propane *) - MBH 15-150 45-225 CSA Input (Natural Gas or Propane *) - KW 4.4-44 13-66 CSA Output - MBH 14-139 41-206 CSA Output - KW 4.1-41 12-60 A.F.U.E 95% 95% Min gas pressure (Nat. Gas or Propane) - inch w.c. 5 5 Max gas pressure (Nat. Gas or Propane) - inch w.c. 14 14 Power (120Vac/60Hz) - Watts @ full fire - Watts 57 167 Weight (empty) - lbs/kg 150 / 68 153 / 70 Pressure vessel water content USG/Liters 2.4 / 9 2.4 / 9 Min boiler flow rate - USgpm 4 8 Max boiler flow rate - USgpm 16 25 Max operating pressure - psig 80 80 Min water pressure - psig 8 8 Normal flue temp @ 100 F boiler return water temp - High Fire 100 F to 105 F 100 F to 105 F Normal flue temp @ 160 F boiler return water temp - High Fire 160 F to 165 F 160 F to 165 F Approved installation altitude - ASL 0-12,000 ft 0-12,000 ft Ambient temperature - Low ( F/ C) 32 F / 0 C 32 F / 0 C Ambient temperature - High ( F/ C) 122 F / 50 C 122 F / 50 C Max relative humidity (non-condensing) 90% 90% Min water temperature ( F/ C) 34 F / 1 C 34 F / 1 C Max water temperature (electronic-limit) ( F/ C) 190 F / 88 C 190 F / 88 C Max water temperature (mechanical hi-limit) ( F/ C) 200 F / 93 C 200 F / 93 C Max ΔT - supply / return (electronic fence) 40 F 40 F Maximum equivalent vent length each side 2 50' N/A Maximum equivalent vent length each side 3 120' 240' (Natural Gas or Propane) Air intake options: either direct vent or indoor supply Natural Gas boilers require a Propane conversion kit to be ordered separately if converting from Natural Gas to Propane. Propane boilers require a Natural Gas conversion kit to be ordered separately if converting from Propane to Natural Gas. Ships with 30psi relief valve. Exhaust pipe size Sched.40; Rigid PPs 2 (15-150 only) 50 3 (15-150) 120 3 (45-225) 240 Maximum equivalent length (each side) 90 vent elbow Allow 8 equivalent 45 elbow Allow 3 equivalent PP s 87-90 elbows Flexible PPs Allow 8 equivalent 2 Flexible Not allowed 3 Flexible (VFC 15-150) 60 (max)aactual lineal x 1.5 = equivalent 3 Flexible (VFC 45-225) 60 (max) Actual lineal x 3 = equivalent 5 YEAR LIMITED MANUFACTURER S PARTS WARRANTY MULTIPLE ZONE PUMP CONTROL UP TO 4 ZONES MFZ - MOISTURE FREE ZONE MANAGEMENT TECHNOLOGY TOUCH SCREEN TECHNOLOGY VFC Series

oisture ree one PATENTED MOISTURE MANAGEMENT SYSTEM Protects and ensures long life for all components in the boiler. Burner plate Combustion chamber Flue gas channels Condensate dish Automated laser welding now underway SL SERIES - BETTER INSTALLATION FLEXIBILITY Made of high grade 439 stainless steel the SL Heat Exchangers deliver 95% AFUE efficiency. The SL Heat Exchangers are easy to inspect and feature a condensate draining system that cleans as it heats. With more models, unmatched safety features and now featuring our new IBC Touch Screen Boiler Controller you get all the features of our 5 button control with the following added features: Express Set Up, easier Diagnostics & Intuitive Alert System with plain English Warnings & Error Messages. There is an SL model for every application.

SL 20-115G2 20,000 to 115,000 BTU/H SL 28-160 28,000 to 160,000 BTU/H RESIDENTIAL CONDENSING BOILERS Supply Supply With Supply and Return connections on both sides of the boiler your installation can t get any easier. Use the left side, the right side or Both. The choice is yours. Touch Screen Boiler Controller Express setup Remote monitoring & diagnostics Easy USB programmability True native BACnet Intuitive alert system Easy homeowner DHW temp adjust Now featuring multiple zone pump control - up to 4 zones. Replacing the need for external pump controls. MFZ Technology: Patented moisture management system. Protects and ensures long life for all components in the boiler. Connect your IBC Indirect Water Tank directly to the boiler without a primary loop. Turndown ratio of 5.75:1 means you have the power to heat your home in the coldest weather, yet reduce short cycling when the weather is mild. Built-in outdoor reset control of water temperature. Better efficiency 95% AFUE. Very low water side and combustion side pressure drops. Venting up to 480 feet on the SL 20-115G2. Limited lifetime residential heat exchanger warranty. See website for details. H Specifications SL 20-115G2 SL 28-160 CSA Input (Natural Gas or Propane *) - MBH 20-115 28-160 CSA Input (Natural Gas or Propane *) - KW 6-34 8.2-47 CSA Output - MBH 19-109 26.2-147 CSA Output - KW 5.5-32 7.7-43 A.F.U.E 95% 95% Min gas pressure (Nat. Gas or Propane) - inch w.c. 5 5 Max gas pressure (Nat. Gas or Propane) - inch w.c. 14 14 Power (120Vac/60Hz) - Watts @ full fire - Watts ( without pumps) 54 73 Weight (empty) - lbs/kg 85/39 102 / 46.3 Pressure vessel water content USG/Liters 2.9 / 11 3.2 / 12.2 Max boiler flow rate - USgpm 14 19 Min boiler flow rate - USgpm 2 4 Max operating pressure - psig 30 30 Min water pressure - psig 8 8 Approved installation altitude - ASL 0-12,000 ft 0-12,000 ft Ambient temperature - Low ( F/ C) 32 F / 0 C 32 F / 0 C Ambient temperature - High ( F/ C) 122 F / 50 C 122 F / 50 C Max relative humidity (non-condensing) 90% 90% Min water temperature ( F/ C) 34 F / 1 C 34 F / 1 C Max water temperature (electronic-limit) ( F/ C) 190 F / 88 C 190 F / 88 C Max water temperature (mechanical hi-limit) ( F/ C) 200 F / 93 C 200 F / 93 C Max ΔT - supply / return (electronic fence) 40 F 40 F Maximum equivalent vent length, each side 2 100' 35' Maximum equivalent vent length, each side 3 240' 170' (Natural Gas or Propane) Air intake options: either direct vent or indoor supply Natural Gas boilers require a Propane conversion kit to be ordered separately if converting from Natural Gas to Propane. Propane boilers require a Natural Gas conversion kit to be ordered separately if converting from Propane to Natural Gas. Ships with 30psi relief valve. Exhaust pipe size Maximum equivalent length SL 20-115G2 SL 28-160 Sched.40; Rigid PPs (each side) (each side) 2 100 35 3 240 170 90 long sweep elbow Allow 5 equivalent Allow 5 equivalent 90 vent elbow Allow 8 equivalent Allow 8 equivalent 45 elbow Allow 3 equivalent Allow 3 equivalent PPs 87-90 elbows Allow 8 equivalent Allow 8 equivalent Flexible PPs 2 Flexible 45 (max) Lineal x 1.4 = equivalent Not allowed 3 Flexible 98 (max) Actual lineal x 1.2 = equivalent 98 (max) Actual lineal x 1.2 = equivalent Return 5 YEAR LIMITED MANUFACTURER S PARTS WARRANTY MULTIPLE ZONE PUMP CONTROL UP TO 4 ZONES MFZ - MOISTURE FREE ZONE MANAGEMENT TECHNOLOGY TOUCH SCREEN TECHNOLOGY SL Series Return

SL 35-199 35,000 to 199,000 BTU/H SL 45-260 45,000 to 260,000 BTU/H CONDENSING BOILERS New to the SL Series, the SL 35-199 expands the capacity of the former SL 30-175 and with the new IBC touch screen controller offers the most flexible control option on the market. Touch Screen Boiler Controller Express setup Remote monitoring & diagnostics Easy USB programmability True native BACnet Intuitive alert system Easy homeowner DHW temp adjust Now featuring multiple zone pump control - up to 4 zones. Replacing the need for external pump controls. MFZ Technology: Patented moisture management system. Protects and ensures long life for all components in the boiler. LWCO options available. Bottom piping connections for easy multi-boiler piping. Connect your IBC Indirect Water Tank directly to the boiler without a primary loop. Industry leading turndown ratio of 5.75:1 means you have the power to heat your home in the coldest weather, yet reduce short cycling when the weather is mild. Built-in outdoor reset control of water temperature. Better efficiency 95% AFUE. Limited lifetime residential heat exchanger warranty. See website for details. H Specifications SL 35-199 SL 45-260 CSA Input (Natural Gas or Propane *) - MBH 35-199 45-260 CSA Input (Natural Gas or Propane *) - KW 10.3-58.3 13.2-76.2 CSA Output - MBH 32.7-181.3 43.2-239 CSA Output - KW 7.7-43 12.7-70.0 A.F.U.E 95% 95% Min gas pressure (Nat. Gas or Propane) - inch w.c. 5 5 Max gas pressure (Nat. Gas or Propane) - inch w.c. 14 14 Power (120Vac/60Hz) - Watts @ full fire - Watts 92 127 Weight (empty) - lbs/kg 151 / 69 162 / 74 Pressure vessel water content USG/Liters 5 / 19 5 / 19 Max boiler flow rate - USgpm 25 25 Min boiler flow rate - USgpm 6 6 Max operating pressure - psig 30 30 Min water pressure - psig 8 8 Approved installation altitude - ASL 0-12,000 ft 0-12,000 ft Ambient temperature - Low ( F/ C) 32 F / 0 C 32 F / 0 C Ambient temperature - High ( F/ C) 122 F / 50 C 122 F / 50 C Max relative humidity (non-condensing) 90% 90% Min water temperature ( F/ C) 34 F / 1 C 34 F / 1 C Max water temperature (electronic-limit) ( F/ C) 190 F / 88 C 190 F / 88 C Max water temperature (mechanical hi-limit) ( F/ C) 200 F / 93 C 200 F / 93 C Max ΔT - supply / return (electronic fence) 40 F 40 F Maximum equivalent vent length each side 3 200' 200' Maximum equivalent vent length each side 4 200' 200' (Natural Gas or Propane) Air intake options: either direct vent or indoor supply Natural Gas boilers require a Propane conversion kit to be ordered separately if converting from Natural Gas to Propane. Propane boilers require a Natural Gas conversion kit to be ordered separately if converting from Propane to Natural Gas. Ships with 30psi relief valve. Exhaust pipe size Sched.40; Rigid PPs 3 200 4 200 Maximum equivalent length (each side) 90 long sweep elbow Allow 5 equivalent 90 vent elbow Allow 8 equivalent 45 elbow Allow 3 equivalent PP s 87-90 elbows Flexible PPs Allow 8 equivalent 3 Flexible (SL 35-199) 160 (max) Lineal x 1.2 = equivalent 3 Flexible (SL 45-260) 60 (max) Lineal x 3.33 = equivalent 4 Flexible 160 (max) Lineal x 1.2 = equivalent 5 YEAR LIMITED MANUFACTURER S PARTS WARRANTY MULTIPLE ZONE PUMP CONTROL UP TO 4 ZONES MFZ - MOISTURE FREE ZONE MANAGEMENT TECHNOLOGY TOUCH SCREEN TECHNOLOGY SL Series

SL 80-399 80,000 to 399,000 BTU/H COMMERCIAL CONDENSING BOILER In today s energy conscious world, choosing the right heating system is crucial to maximizing a buildings energy savings and environmental impact. The cost effective solution to any application, whether the application is a retrofit or new construction, combining the SL 80-399 boiler with the flexibility of the Multiplex Racking Systems and IBC s new touchscreen controller the options available are endless. Specifications CSA Input (Natural Gas or Propane *) - MBH SL 80-399 80-399 Touch Screen Boiler Controller Express setup Remote monitoring & diagnostics Easy USB programmability True native BACnet Intuitive alert system Easy homeowner DHW temp adjust Multi boiler communication up to 9.5 million Btu/h (24 boilers) without additional controls. With 24 boilers turndown ratio is 120:1 = min. firing rate range is 80,000 Btu/h all the way up to 9.5 million Btu/h in 1000 Btu/h increments. Now featuring multiple zone pump control - up to 4 zones. Replacing the need for external pump controls. MFZ Technology: Patented moisture management system. Protects and ensures long life for all components in the boiler. DDC Control 0-10 VDC or 4-20 ma without additional controls. 95.7% Efficiency - CSA 4.9-2010. Optional 316Ti Titanium Heat Exchanger. DHW opt out priority for multi boiler systems. Up to 10 year commercial heat exchanger warranty. See website for details. Various Multiplex Racking & rack only options available. H CSA Input (Natural Gas or Propane *) - KW 23.4-117 CSA Output - MBH 77-382 CSA Output - KW 22.6-112 Combustion Efficiency (CSA 4.9 2010) 95.7% Min gas pressure (Nat. Gas or Propane) - inch w.c. 5 Max gas pressure (Nat. Gas or Propane) - inch w.c. 14 Power (120Vac/60Hz) - Watts @ full fire - Watts ( without pumps) 345 Weight (empty) - lbs/kg 240 / 110 Pressure vessel water content USG/Liters 7 / 26 Max boiler flow rate - USgpm 45 Min boiler flow rate - USgpm 20 Max operating pressure - psig 80 Min water pressure - psig 8 Approved installation altitude - ASL Natural Gas boilers require a Propane conversion kit to be ordered separately if converting from Natural Gas to Propane. Propane boilers require a Natural Gas conversion kit to be ordered separately if converting from Propane to Natural Gas. Ships with 30psi relief valve. Exhaust pipe size Sched.40; Rigid PPs 4 200 Maximum equivalent length (each side) 90 long sweep elbow Allow 5 equivalent 90 vent elbow Allow 8 equivalent 45 elbow Allow 3 equivalent PPs 87-90 elbows Flexible PPs Allow 8 equivalent 0-12,000 ft Ambient temperature - Low ( F/ C) 32 F / 0 C Ambient temperature - High ( F/ C) 122 F / 50 C Max relative humidity (non-condensing) 90% Min water temperature ( F/ C) 34 F / 1 C Max water temperature (electronic-limit) ( F/ C) 190 F / 88 C Max water temperature (mechanical hi-limit) ( F/ C) Max ΔT - supply / return (electronic fence) 40 F Maximum equivalent vent length, each side 4 200' (Natural Gas or Propane) Air intake options: either direct vent or indoor supply 200 F / 93.3 C 4 Flexible 160 (max) Actual lineal x 1.2 = equivalent New 399 bolt design exclusively from IBC. 5 YEAR LIMITED MANUFACTURER S PARTS WARRANTY MULTIPLE ZONE PUMP CONTROL UP TO 4 ZONES NEW AND INNOVATIVE SIDE BOLT H X LID CONFIGURATION TOUCH SCREEN TECHNOLOGY SL Series

Menu Express Setup Load Status User Setup Installer Setup Diagnostics Back IBC 04:30 ADVANCED CONTROL TECHNOLOGY At IBC we are dedicated to finding new and better ways to provide superior comfort and fuel savings to our customers. We are pleased to announce that all IBC boilers in the SL & VFC Series are now equipped with our new Touch Screen Boiler Controller featuring the latest in advanced touch screen technology and software features.

V-10 TOUCH SCREEN CONTROLLER Available in all VFC & SL Series Boilers IBC CONTROL AT YOUR FINGERTIPS Building on the success of our industry leading 5 button boiler control launched in 2003, the new touch screen control makes it even easier to setup and monitor your IBC Boiler. With intuitive features like Express Setup, easier Diagnostics & Intuitive Alert System with plain English Warnings & Error Messages your VFC or SL Series boiler has never been easier to use. EXPRESS SETUP Program your boiler in seconds with an interview style, quick start menu. User friendly interface for contractor and home owner. ZONING Now featuring multiple zone pump control - up to 4 zones. Replacing the need for external pump controls. COMPLETE REMOTE ACCESS Built in internet connectivity. Monitor your boilers operation in real time from your PC/Mac. Remote monitoring & diagnostics. EASY USB PROGRAMMABILITY USB Port for software updates and copying settings to the next boiler. TRUE NATIVE BACnet Seamlessly integrate IBC BACnet enabled boilers into your current building automation system. MORE FLEXIBILITY Intuitive alert system with plain English warnings & error messages. Built in alarm notification relay. Automatic altitude adjustment. Pre programmed values for all load types. Home Page Screen Main Menu Express Setup Load combining features Immediate input feedback Color coded error notifications CONTROLS

HC 13-50 13,500 to 51,000 BTU/H HC 20-125 20,000 to 125,000 BTU/H HC 23-84 23,000 to 84,000 BTU/H HC 33-160 33,000 to 160,000 BTU/H CONDENSING BOILERS HC 29-106 29,000 to 106,000 BTU/H Introducing IBC s smallest ever boiler, the HC series begins with the HC 13-50 offering the solution for todays better insulated buildings. With onboard full outdoor reset and a slim boiler room footprint the HC Series offers great value for money without sacrificing reliability. Unique and innovative single pass Copper / Aluminum Heat Exchanger, ensuring greater efficiency and eliminating water side corrosion. Up to 95% AFUE, with full ASME rated vessel. Built in boiler pump. 2 & 3 venting options available. Contractor friendly, easy to install, maintain and service. Fewer parts ensuring greater reliability. Outdoor reset technology increases efficiency by lowering the water temp automatically. Reset heating - Set point - DHW. Includes Air Vent, Outdoor Sensor & Relief Valve. Exceptional value. Better reliability and durability. 5 year limited manufacturer s parts warranty 10 year limited heat exchanger warranty H Specification HC 13-50 HC 23-84 HC 29-106 HC 20-125 HC 33-160 CSA Input (Natural Gas or Propane *) MBH 13.5 51 23 84 28.5 106 20 125 33 160 CSA Input (Natural Gas or Propane *) KW 3.95 14.94 6.7 24.9 8.4 31.0 5.6 36.6 9.7 46.9 CSA Output MBH 12.4 45.4 21.2 74.8 26.3 94.3 18.6 110.8 30.4 140.0 CSA Output - KW 3.64 13.3 6.2 21.9 7.7 27.6 5.4 32.5 8.9 41.0 A.F.U.E 95% 94% 94% 95% 94% Min gas pressure (Nat. Gas or Propane) inch w.c. 5 5 5 5 5 Max gas pressure (Nat. Gas or Propane) inch w.c. 14 14 14 14 14 Power (120Vac/60Hz) - Watts @ full fire with internal pump 126 126 128 130 164 Weight (empty) lbs/kg 85 / 39 85 / 39 85 / 39 85 / 39 85 / 39 Pressure vessel water content USG/Liters 0.37/1.4 0.37/1.4 0.37/1.4 0.5/1.9 0.5/1.9 Max boiler flow rate - USgpm 9 9 10 11 11 Min boiler flow rate - USgpm 2 2 3 3 3 Max operating pressure Space Heating Coil - psig 43.5 43.5 43.5 43.5 43.5 Approved installation altitude - ASL 12,000 ft 12,000 ft 12,000 ft 12,000 ft 12,000 ft Ambient temperature Low ( F/ C) 32/0 32/0 32/0 32/0 32/0 Ambient temperature High ( F/ C) 122/50 122/50 122/50 122/50 122/50 Max relative humidity (non-condensing) 90% 90% 90% 90% 90% Min water temperature - Space Heating ( F/ C) 50/20 50/20 50/20 50/20 50/20 Max water temperature Space Heating ( F/ C) 194/90 194/90 194/90 194/90 194/90 Max equivalent vent length 2" (each side) 35' 35 35 35' 35' Max equivalent vent length 3" (each side) 120' 120 120' 120' 120' Natural Gas boilers require a Propane conversion kit to be ordered separately if converting from Natural Gas to Propane. Propane boilers require a Natural Gas conversion kit to be ordered separately if converting from Propane to Natural Gas. Ships with 30psi relief valve. 5 YEAR LIMITED MANUFACTURER S PARTS WARRANTY 10 YEAR LIMITED HEAT EXCHANGER WARRANTY See website for details HC Series

DC 29-106 DC 23-84 29,000 to 106,000 BTU/H 23,000 to 84,000 BTU/H 5 YEAR LIMITED MANUFACTURER S PARTS WARRANTY 10 YEAR LIMITED HEAT EXCHANGER WARRANTY DC 33-160 DC 33-124 33,000 to 160,000 BTU/H 33,000 to 124,000 BTU/H Part# 190-149 EZ Pipe Manifold DUAL CONDENSING COMBI BOILERS At long last On Demand DHW joins the IBC boiler lineup. Combining Domestic Hot Water & Space Heating in a single compact design, the DC Series offers a tried and true heat exchanger design. With the DHW comfort mode, the cold water sandwich is eliminated with no moving parts. Two independent copper coils embedded in a cast aluminium heat exchanger. Built in boiler pump. Self-cleaning, self-draining vertical fin heat exchanger. Built-in supply and return sensors control the heat exchanger temperature (versus temperature), thus eliminating failures. water Copper waterways provide stable performance and glycol compatibility. Heat exchanger has a 20 year track record, with over 1.5 million boilers installed. Contractor friendly, fewer internal parts, easy to install, maintain and service. Outdoor reset technology increases efficiency by lowering the water temp automatically. 5 year limited manufacturer s parts warranty 10 year limited heat exchanger warranty. See website for details. Specification CSA Input (Natural Gas or Propane) MBH DC 23-84 23 84 DC 29-106 28.5 106 DC 33-124 33 124 DC 33-160 33 160 CSA Input (Natural Gas or Propane) KW 6.7 24.9 8.4 31.0 9.7 36.3 9.7 46.9 CSA Output MBH 21.2 74.8 26.3 94.3 31 115 30.4 140.0 CSA Output - KW 6.2 21.9 7.7 27.6 9.0 33.8 8.9 41.0 DHW - CSA Input (Natural Gas or Propane) - MBH 23-84 28.5-106 33-124 33-124 DHW - CSA Input (Natural Gas or Propane) - KW 6.7-24.9 8.4-31.0 9.7-36.3 9.7-36.3 A.F.U.E 94% 94% 94% 94% Min gas pressure (Nat. Gas or Propane) inch w.c. 5 5 5 5 Max gas pressure (Nat. Gas or Propane) inch w.c. 14 14 14 14 Power (120Vac/60Hz) - Watts @ full fire with internal pump 126 128 130 164 Weight (empty) lbs/kg 85 / 39 85 / 39 85 / 39 85 / 39 Pressure vessel water content USG/Liters 0.37/1.4 0.37/1.4 0.5/1.9 0.5/1.9 Max boiler flow rate - USgpm 9 10 11 11 Min boiler flow rate - USgpm 2 3 3 3 Max operating pressure Space Heating Coil - psigo 43.5 43.5 43.5 43.5 Max operating pressure Domestic Hot Water Coil - psig 150 150 150 150 Approved installation altitude - ASL 12,000 ft 12,000 ft 12,000 ft 12,000 ft Ambient temperature Low ( F/ C) 32/0 32/0 32/0 32/0 Ambient temperature High ( F/ C) 122/50 122/50 122/50 122/50 Max relative humidity (non-condensing) 90% 90% 90% 90% Min water temperature - Space Heating ( F/ C) 50/10 50/10 50/10 50/10 Max water temperature Space Heating ( F/ C) 194/90 194/90 194/90 194/90 Min water temperature Domestic Hot Water ( F/ C) 104/40 104/40 104/40 104/40 Max water temptrature Domestic Hot Water ( F/ C) 149/65 149/65 149/65 149/65 Min flow rate to activate DHW heating - USgpm 0.5 0.5 0.5 0.5 Max flow rate DHW heating - USgpm 2.6 3.3 4 4 Max equivalent vent length 2" (each side) 35' 35' 35' 35' Max equivalent vent length 3" (each side) 120 120' 120' 120' 2.7 GPM 3.2 GPM 3.2 GPM Domestic Hot Water Delivery: @70 F/ 39 C temperature rise 2.1 GPM Natural Gas boilers require a Propane conversion kit to be ordered separately if converting from Natural Gas to Propane. Propane boilers require a Natural Gas conversion kit to be ordered separately if converting from Propane to Natural Gas. H Ships with 30psi relief valve. DC Series Up to 94% AFUE with full ASME rated vessel.

IBC INDIRECT WATER HEATERS High performance domestic hot water tanks made of 316L stainless steel. Ships with a domestic hot water sensor ready to communicate with any VFC or SL Series boiler.

30 TO 115 GALLON 30, 40, 50, 60, 80, 115 Gallon (US) IBC INDIRECT WATER HEATERS Top connections for easy installation. Low profile height available for small spaces on selected models. High Output options & large pipe connections available on selected models. High capacity smooth wall coils which are resistant to airlocks. Durable high grade 316L stainless steel. Fail proof, welded stainless steel dip tube. A full 2 of insulation for an extremely low standby heat loss. A thermoplastic jacket that will not corrode Optional Honeywell Aquastat for additional flexibility. Quality brass ball valve style drain and T+P valves are factory installed. Conforms to UL STD 174, Certified to CAN/ CSA STD C22.2 No. 110-94. Call IBC for special order on storage & buffer tanks. *10 year non prorated residential warranty with limited lifetime option. Durable Stainless Steel MODEL HEIGHT INCHES DIMENSIONS PIPING CONNECTIONS NPT MAXIMUM DIAMETER INCHES DOMESTIC WATER IN/OUT BOILER WATER IN/OUT WORKING PRESSURE (PSI) APPROX. SHIPPING WEIGHT IBC 30 34 23.5 3/4 1 150 85 IBC 40 44 23.5 3/4 1 150 100 IBC 40L 36 28.0 3/4 1 150 100 IBC 50 54 23.5 3/4 1 150 110 IBC 60 62 23.5 3/4 1 150 125 IBC 60L 46 28.0 3/4 1 150 120 IBC 80 56 28.0 1 1 150 140 IBC 115 74 28.0 1 1 150 175 HIGH OUTPUT UNITS IBC 80-HO 56 28.0 1 1 150 155 IBC 115-HO 74 28.0 1 1 150 190 IBC 80-HOC 56 28.0 1 1/2 1 1/4 150 155 IBC 115-HOC 74 28.0 1 1/2 1 1/4 150 190 MODEL MAX. FIRST HOUR RATING GAL/Hr @ EXTRA HIGH OUTPUT UNITS IBC 85-XHO 64 28.0 1 1/2 1 1/2 150 215 IBC 115-XHO 74 28.0 1 1/2 1 1/2 150 240 CONTINOUS RATING GAL/HR@ 140F 115F 140F 115F BOILER OUTPUT REQUIRED BTU/HR BOILER WATER PRESSURE FLOW DROP THROUGH THROUGH COIL COIL (FT. WATER) IBC 30 176 233 149 206 111,560 14.0 5.3 IBC 40 193 254 157 218 117,870 14.0 5.7 IBC 40L 186 251 150 215 112,200 14.0 5.3 IBC 50 196 254 151 209 113,290 14.0 6.0 IBC 60 231 298 177 244 132,340 14.0 6.2 IBC 60L 211 272 157 218 117,785 14.0 5.7 IBC 80 241 306 169 234 126,980 14.0 6.0 IBC 115 291 363 188 260 140,890 14.0 6.6 HIGH OUTPUT UNITS IBC 80-HO 366 479 294 407 220,440 14.0 9.9 IBC 115-HO 413 532 310 429 232,135 14.0 10.5 IBC 80-HOC 386 507 314 435 235,510 21.0 15.8 IBC 115-HOC 423 545 320 442 239530 21.0 16.7 EXTRA HIGH OUTPUT UNITS IBC 85-XHO 649 868 571 790 428,000 28.0 13.0 IBC 115-XHO 674 893 571 790 428,000 28.0 13.0 Note: All ratings are based on 180 degree F boiler cold water inlet. For 160 degree F boiler water supply multiply ratings by 0.86. In the interest of continuous improvement, specifications are subject to change without notice. SL IBC Series Tanks

MULTI-PLEX Racking A Modular system for commercial and multi family installation the Multiplex racking system components fit through standard doorways reducing the need for heavy transport equipment. Our easy to set up boiler networks also provide for precise load matching through wide turndown ratios.

MULTI-PLEX Racking Designed for the SL 80-399 ENGINEERED EASY TO INSTALL TURNKEY SYSTEM INCLUDES Pumps: Model - UPS 43-44F Isolation ball valves - Check valves Welded steel headers - Connecting piping Flexible stainless steel connectors Boiler drains - Optional accessories available Freestanding inline or back to back options. Header sizes include: 3, 4 or 6. Left or right header connections includes 1 set of blind flanges. Combination from 2 to 12 boilers on one Multiplex racking system. Flow switches, external sensors optional. Low Loss Header options: 3, 4 or 6. Compact Design: Easy to get into small spaces around existing equipment. Seismic ratable. Rack only options also available. Easy 1 day installation. Approximate assembly time for 4 x SL 80-399 x 2 men = 8 Hours. SPECIFICATIONS Multiplex Racking System Part No. Width "/ mm Height " / mm Depth "/ mm IN LINE RACK 3" Header 2 Boiler In-line 90-151 70" / 1778 mm 76.25" / 1937 mm 35.5" / 902 mm 3 Boiler In-line 90-149 102" / 2590 mm 76.25" / 1937 mm 35.5" / 902 mm 4" Header 2 Boiler In-line 90-159 70" / 1778 mm 76.25" / 1937 mm 35.75" / 908 mm 3 Boiler In-line 90-160 102" / 2590 mm 76.25" / 1937 mm 35.75" / 908 mm 4 Boiler In-Line 90-161 134" / 3404 mm 76.25" / 1937 mm 35.75" / 908 mm 5 Boiler In-Line 90-162 166" / 4217 mm 76.25" / 1937 mm 35.75" / 908 mm 6 Boiler In-Line 90-163 198" / 5030 mm 76.25" / 1937 mm 35.75" / 908 mm 6" Header 4 Boiler In-line 90-171 134" / 3404 mm 76.25" / 1937 mm 38" / 965 mm 5 Boiler In-line 90-178 166 / 4217 mm 76.25 / 1937 mm 38 / 965 mm 6 Boiler In-line 90-164 198" / 5030 mm 76.25" / 1937 mm 38" / 965 mm 8 Boiler In-line 90-165 262" / 6656 mm 76.25" / 1937 mm 38" / 965 mm 10 Boiler In-line 90-166 326" / 8280 mm 76.25" / 1937 mm 38" / 965 mm 12 Boiler In-line 90-176 390" / 9906 mm 76.25" / 1937 mm 38" / 965 mm 4" Header BACK TO BACK RACK 2 + 2 Boiler Back to Back 90-167 70" / 1778 mm 76.25" / 1937 mm 58.5" / 1486 mm 3 + 3 Boiler Back to Back 90-168 102" / 2590 mm 76.25" / 1937 mm 58.5" / 1486 mm 6" Header 3 + 3 Boiler Back to Back 90-169 102" / 2590 mm 76.25" / 1937 mm 60.5 / 1537 mm 4 + 4 Boiler Back to Back 90-170 134" / 3404 mm 76.25" / 1937 mm 60.5 / 1537 mm 5 + 5 Boiler Back to Back 90-172 166" / 4217 mm 76.25" / 1937 mm 60.5 / 1537 mm 6 + 6 Boiler Back to Back 90-177 198 / 5030 mm 76.25 / 1937 mm 60.5 / 1537 mm SPECIFICATIONS - Racking only Racking Only Part No. Width " / mm Height " / mm Depth / mm 1 Boiler Rack R-137 38" / 965 mm 76.25" / 1937mm 26.5" / 673 mm 2 Boiler Rack R-138 70" / 1778 mm 76.25" / 1937mm 26.5" / 673 mm 3 Boiler Rack R-136 102" / 2590 mm 76.25" / 1937mm 26.5" / 673 mm 4 Boiler Rack R-139 134" / 3404mm 76.25" / 1937mm 26.5" / 673 mm 5 Boiler Rack R-140 166" / 4217 mm 76.25" / 1937mm 26.5" / 673 mm 6 Boiler Rack R-134 198" / 5030 mm 76.25" / 1937mm 26.5" / 673 mm 7 Boiler Rack R-141 230" / 5843 mm 76.25" / 1937mm 26.5" / 673 mm 8 Boiler Rack R-142 262" / 6656 mm 76.25" / 1937mm 26.5" / 673 mm Racking

IBC Technologies Inc. (Head Office) 8015 North Fraser Way Burnaby, BC, Canada V5J 5M8 Tel: 604-877-0277 Fax: 604-877-0295 info@ibcboiler.com Better Boilers IBC USA 4203 Industrial Court Sheboygan, WI, USA 53083 Tel: 920-783-8340 Fax: 920-783-8339 R4 Feb 2016 All information contained in this brochure is subject to change without notice. Due to clerical error, regulation change or product development please confirm all information with IBC PRINTED IN CANADA