How To Size A Stenner Pump

Similar documents
SMS SERIES MIXER SYSTEM INSTALLATION AND MAINTENANCE MANUAL

Advantium 2 Plus Alarm

Installation and Operation Guide for PD5100 Automatic Transfer Switch

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Replace the Pump Tube Classic

Ceiling Mount Air Handler Manual

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Streaming Potential System (SPT1000, SPD1000)

ATS Overhead Table Shelf System INSTRUCTION MANUAL

BroadBand PowerShield. User Manual

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

HP UPS R1500 Generation 3

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

Stenner Pump Chlorinator Installation & Start Up Guide

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

OPL BASIC. Dosing System for Professional Laundry machines. Contents

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

INSTANT HOT WATER RECIRCULATING SYSTEM

Installation and Operation Guide for PD4100 Series Power Control Centers

B-AIR BLOWER CUB POWER MODEL # CP-1

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

12-Volt 10-Amp Regulated Power Supply

Dehumidifier Users manual. For Models: DH45S DH65S

Model 1756 Test Lead Kit

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

E-Version SECTION CHLORINATION SYSTEM PART 1 - GENERAL PART 2 - PRODUCT


USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

ADM1TE 5/30A DIN rail single phase two wire energy meter

Bubble King. User Manual

Bottom Loading Water Dispenser

Leak Detection System

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Instructions for Connecting PETROSMART EZ Control Systems To Wayne Electronic Dispensers With/Without CAT CREDIT CARD MODULES

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

ANI-64S-xRU. Single Section Wall Cabinet INSTRUCTION MANUAL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

VK-250 WARRANTY REGISTRATION FORM

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

WARMER or COOKER/WARMER

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Doorbell Intercom Security System

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

IR Repeater. Operation Manual P8620

DRY-BATH INCUBATOR. MODELS I-G35, I-G55, I-120 and I-240. Owner/Operator Manual

Perseus. Owner s Manual. Vacuum Tube Preamplifier. Rogue Audio, Inc. 3 Marian Lane Brodheadsville, PA Issue date: 02/01/06

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Automatic Phone-Out Home Monitoring Systems

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

PagePac PAGEPAL V

Model Owner s Manual. Español - P. 19 Français - P. 39

Hard Disk Drive (HDD)

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

Nest Learning Thermostat Installation Guide. Installation step-by-step

MODEL MAC-3 MULTIPLE APPLIANCE CONTROL

Installation and Operation Guide for PD4000 Series Power Control Center

How To Install A Power Supply (Uplast) With A Battery Pack

Installation Manual Version 7.3 IMPORTANT:

±15 V Current-Limited Power Supply

DC400 Dispensing Cutoff System

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions.

3 WATT LED SPOTLIGHT Model No. SLM

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Benchtop Computer Monitor Generator

Single Station Remote Alarm

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

4 in 1 Air Compressor

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

HM-W536 Install Guide

Liquid Carbon Balanced Transportable Headphone Amplifier. Cavalli audio. Copyright Cavalli Audio, LLC All Rights Reserved

STC 3S A Series Solenoid Valves

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Installation, Operation, Repair and Parts Manual

Installation and Operation Guide PD4600 Series Converter Replacement

Replacing the vacuum tube

Operating Guide Manuel de l utilisateur

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

TABLE OF CONTENTS. Hurricane 1300 User Manual 2 Rev. 4

INSTRUCTION MANUAL MODEL PCD-88

Installation Instructions

Guide To Returning Your Satellite Modem and Radio Assembly Model: HN7000S

Transcription:

Metering Pumps Manufactured Since 1957 PCM Series Pump Control Module INSTALLATION AND MAINTENANCE MANUAL

Table of Contents WarrantyandServicePolicy...3 Safety Information............................................... 4-5 Specifications................................................... 6 PCM and Pump Sizing............................................ 7-11 Installation..................................................... 12-13 Troubleshooting...14 PCMModelConversion...15 2 www.stenner.com

Warranty and Service Policy Damaged or Lost Shipments UPS and prepaid truck shipments: Check your order immediately upon arrival. All damage must be noted on the delivery receipt. Call Stenner Customer Service at 800-683-2378 for all shortages and damages within seven (7) days of receipt. Returns Stenner offers a 30-day return policy. Except as otherwise provided, no material will be accepted for return after 30 days from purchase. To return merchandise at any time, call Stenner at 800-683-2378 for a Returned Goods Authorization (RGA) number. A 15% re-stocking fee will be applied. Include a copy of your invoice or packing slip with your return. Limited Warranty Stenner Pump Company will for a period of one (1) year from the date of purchase (proof of purchase required) repair or replace at our option all defective parts. Stenner Pump Company is not responsible for any removal or installation costs. Stenner Pump Company will incur shipping costs for warranty products shipped from our factory in Jacksonville, Florida. Any tampering with major components, chemical damage, faulty wiring, weather conditions, power surges, or products not used with reasonable care and maintained in accordance with the instructions will void the warranty. Stenner Pump Company limits its liability solely to the cost of the original product. We make no other warranty expressed or implied. Disclaimer The information contained in this manual is not intended for specific application purposes. Stenner Pump Company reserves the right to make changes to prices, products, and specifications at any time without prior notice. US and Canada call 1-800-683-2378, other countries call 1-904-641-1666 3

Safety Information Warns about hazards that CAN cause death, serious personal injury, or property damage if ignored. ELECTRIC SHOCK HAZARD: Equipment is supplied with grounding power cord and attached plug. To reduce risk of electrical shock, connect only to a properly grounded, grounding type receptacle. DO NOT alter the power cord or plug end. DO NOT use receptacle adapters. DO NOT use PCM with a damaged or altered power cord or plug. Contact the factory for repair. ELECTRIC SHOCK HAZARD HAZARDOUS VOLTAGE: DISCONNECT power cord before removing motor cover for service. Electrical service by trained personnel only. EXPLOSION HAZARD: This equipment IS NOT explosion proof. DO NOT install or operate in an explosive environment. RISK OF FIRE HAZARD: DO NOT install or operate on any flammable surface. 4 www.stenner.com

Safety Information continued NOTICE: Indicates special instructions or general mandatory action. DO NOT attempt installation or service prior to reading and understanding all safety hazards. This equipment is designed for installation and service by trained personnel. DO install PCM so that it is in compliance with all national and local codes. DO use all required personal protective equipment when working on or near chemical metering pumps. This is the safety alert symbol. When displayed in this manual or on the equipment, look for one of the following signal words alerting you to the potential for personal injury or property damage. PCM INTENDED FOR INDOOR USE. Electrical installation should adhere to all national and local codes. Consult a licensed professional for assistance with proper electrical installation. US and Canada call 1-800-683-2378, other countries call 1-904-641-1666 5

Specifications Timer...Microcontroller with triac output TurndownRatio...10:1 Housing...Polycarbonate plastic Shipping Weight...2 lbs Input Signal... Non-voltage dry contact, water meter ResetTime...Immediate Minimum Signal Duration...10 milliseconds Input Electrical...120V 60Hz No Load Current...0.45mA AC maximum Front Top Output Electrical... maximum device load, 1.8 amp at 120V 1 3/4" 5 3/8" 3 5/8" Side 1 3/4" 35/8" 5 3/4" 6 www.stenner.com

PCM and Pump Sizing Maximum flow rate (of the water system) in gallons per minute (gpm) Required dose amount in parts per million (ppm) Pre-sizing Requirements Water Meter cpg/ppg (partial list) Meter Size Max Flow Rate (gpm) Meter cpg/ppg Solution strength in parts per million (ppm) Water meter contacts per gallon (cpg or ppg) Stenner fixed output metering pump cpg ppm gpm gpd gps Key contacts per gallon (ppg pulse per gallon) parts per million gallons per minute gallons per day gallons per second 3/4" 20 10 3/4" 20 5 3/4" 20 2.5 3/4" 20 1 1" 50 1 1" 50 2 1" 50 4 1" 50 5 1 1/2" 100 1 1 1/2" 100 2 1 1/2" 100 4 The most popular water meter and the easiest for calculation purposes is the 1 contact (cpg) or 1 pulse per gallon (ppg) dry contact water meter. spg seconds per gallon US and Canada call 1-800-683-2378, other countries call 1-904-641-1666 7

PCM and Pump Sizing continued I. Determining Available Dose Time 1. The available dose time is the minimum time interval (seconds) between the water meter contact closures during the maximum system flow rate. Each closure sends an input signal to the PCM. Do not adjust the PCM time to a longer duration than the minimum time duration between water meter contacts. 2. The available dose time is calculated using two equations: a. Divide 60 seconds by the maximum system flow rate in gpm to convert to seconds per gallon. 60 seconds gpm = spg b. Divide the seconds per gallon by the water meter s contacts per gallon to determine the minimum time between meter contact closures. spg cpg = available dose time in seconds 8 www.stenner.com

PCM and Pump Sizing continued II. Calculating Dosage Required (gpd) 1. The daily dosage requirements in gpd are based upon the maximum flow rate of the system, dosage requirements in ppm, and the strength of solution in ppm. Refer to chart below. II. Calculating dosage required (gpd) 2. (max system flow rate X dosage required X 1440) solution strength (gpm X ppm X 1440) ppm = required dose output (gpd) Common Chemical Solution Strengths Common Name Chemical Name Strength % Strength ppm Bleach Sodium Hypochlorite (NaOCl) 5.25 52,500 Bleach Sodium Hypochlorite (NaOCl) 6.125 61,250 Bleach Sodium Hypochlorite (NaOCl) 12.5 125,000 Potassium Potassium Permanganate as 3 30,000 Permanganate KMnO4 dissolved at 1/4 lb per Gal Peroxide Hydrogen Peroxide 7 70,000 Polyphosphate Polyphosphate dissolved at 1/4 lb per 10 Gals 1.2 12,000 US and Canada call 1-800-683-2378, other countries call 1-904-641-1666 9

PCM and Pump Sizing continued Stenner Fixed Output Pumps Model gpd 45MPHP2 3 45MPHP10 10 45MPHP22 22 85MPHP5 5 85MPHP17 17 85MPHP40 40 III. Selecting a Feed Pump Model Select a model number from the table that slightly exceeds the required dose output (gpd) as determined in Step II. IV. Determining Feed Time Duration (seconds) Divide the required dose output (gpd) as determined in Step II by the output of the model pump selected in Step III and multiply by the available dose time from Step I. (gpd required gpd selected pump) X available dose time in seconds = feed time duration NOTICE: Use a PCM and pump model combination that prevents the PCM time setting (Step IV) from being greater than the available dose time (Step I). The available dose time is the minimum time duration between water meter contacts (or input signals to the PCM at maximum system flow rate). DO NOT adjust the PCM to a setting greater than the available dose time. Failure to maintain this relationship will result in chemical feed errors. The PCM is designed for use with fixed output metering pumps. Adjustable pumps MUST be used at maximum output. 10 www.stenner.com

PCM and Pump Sizing continued V. Determining PCM Model and Setting 1. If feed time duration is: Less than 1 second, select PCM1. Between 1 and 5 seconds, select PCM5. Between 5 and 10 seconds, select PCM10. Between 10 and 20 seconds, select PCM20. Model Time Range (seconds) PCM1 0.1 1.0 PCM5 0.5 5.0 PCM10 1.0 10.0 PCM20 2.0 20.0 Timing options are factory preset. 2. To determine % setting of the PCM, divide feed time duration (Step IV) by max. seconds of PCM model selected and multiply by 100. feed time duration in seconds PCM model max seconds X 100 = % PCM setting This will give you the % setting of the PCM. The PCM has a 10:1 turndown ratio and the setting is achieved by turning the PCM knob to the approximate % setting. NOTICE: FINAL PCM SETTINGS must be determined through analytical testing of the water. The procedure and formulas contained herein are intended solely as a guide to be used to assist in the proper application of Stenner s PCM (Pump Control Module). Stenner Pump Company makes no guarantee as to the accuracy of the information contained herein. User assumes all risk and liability from use of the information contained in this manual. US and Canada call 1-800-683-2378, other countries call 1-904-641-1666 11

Installation Do mount PCM in a dry location to avoid water intrusion and damage. 1. Position the PCM within 6 feet of the Stenner fixed output metering pump and mount to a suitable surface using adequate fasteners through the mounting holes. Do check supply voltage prior to connecting power cord to prevent damage. The use of a GFIC circuit is recommended. 2. Uncoil the input signal cable and remove approximately 2 inches of the outer cable jacket. Do not connect PCM input signal cord to any AC voltage supply. Do not connect PCM input signal cord to any hall effect, 4-20mA or voltage carrying signal source. Do use PCM ONLY with a dry contact, reed switch style water meter. 4. Attach the two wires to the contact output water meter or relay switch. 5. Adjust the knob to the desired on-time duration. Refer to the PCM and Pump Sizing on pages 7-11 for assistance. Do not use pump adjustment to control dosage. An adjustable metering pump must be used at the maximum pump setting or use a fixed output pump. 6. Plug the fixed output chemical feed pump power cord into the PCM s receptacle. 7. Plug the PCM power cord into a properly installed, grounded, 120VAC receptacle. 3. Strip the ends of the two wires within the cable approximately one-half inch. 12 www.stenner.com

Installation Diagram Metering Pump Power Cord 120 Power Outlet PCM PCM Input Signal Cable Stenner Fixed Output Metering Pump Connection Water Meter Output Cable PCM Power Cord Point of Injection Spill Recovery Tube Solution Tank Water Meter Shut-Off Valve US and Canada call 1-800-683-2378, other countries call 1-904-641-1666 13

Troubleshooting The typical cause of an apparent failure of the PCM is usually: Lack of Input Supply Voltage (120VAC) Plug the fixed output chemical metering pump directly into the 120VAC receptacle into which the PCM was originally plugged; this will bypass the PCM. If the pump does not run, the power source or pump is defective. If the metering pump operates, proceed to Lack of Proper Input Signal. The typical cause of an apparent failure of the PCM is usually: Lack of Proper Input Signal Plug the metering pump into the PCM and the PCM into the receptacle tested in Step I. Remove the PCM input signal cable from the water meter or relay and touch the two wires together. The pump should run for the pre-determined on-time and then stop. If the metering pump runs, the failure is in the water meter contacts. If the metering pump does not run, the failure is in the PCM. Contact the factory for information on service and repair. 14 www.stenner.com

PCM Model Conversion HAZARDOUS VOLTAGE: DISCONNECT power cord before removing motor cover for service. The PCM time range is factory set according to the specific model. The time range can be changed to convert a PCM to any of four available time ranges without purchasing another model. The time range is converted by changing the position of the jumper on the printed circuit board located under the PCM s cover. Illustration A. The PCM is equipped with two jumpers that are positioned over the pins labeled 3, 2, 1. Illustration B. To change the time range: 1. Unplug the PCM power cord from the input power supply. 2. Remove the cover (four screws) and reposition the jumper to correspond with the desired time range. See chart below. 3. Replace the PCM cover and secure with the four screws. 4. IMPORTANT! Update the PCM data label to represent the converted model and time range for accurate sizing. A B Jumpers Model PCM1 PCM5 PCM10 PCM20 Time Range 0.1 1.0 seconds 0.5 5.0 seconds 1.0 10.0 seconds 2.0 20.0 seconds 3 2 1 Jumper 2&1 3&2 3 3&2,2&1 Pins Location of the time range 3 2 1 3 2 1 3 2 1 3 2 1 US and Canada call 1-800-683-2378, other countries call 1-904-641-1666 15

3174 DeSalvo Road Jacksonville, Florida 32246 sales@stenner.com www.stenner.com Phone: 904.641.1666 US Toll Free: 800.683.2378 Fax: 904.642.1012 Metering Pumps Manufactured Since 1957 Hours of Operation (EST): Mon. Fri. 7:00 am 5:30 pm PCM07