Replace the Pump Tube Classic



Similar documents
SMS SERIES MIXER SYSTEM INSTALLATION AND MAINTENANCE MANUAL

How To Size A Stenner Pump

INSTALLATION & OPERATING INSTRUCTIONS

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

orlando OWNER S MANUAL

Oil and Coolant Circulating Heating System. Model - OCSM

IMPORTANT SAFETY NOTICE

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

San josé OWNER S MANUAL

MODEL E-AF. Drain Cleaning Machine. Operator s Manual

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

IMPORTANT SAFETY INSTRUCTIONS

Fuel Injection Pump, Rotary ( )

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

SINGLE STAGE INLINE FIRE PUMP

IMPORTANT SAFETY RULES TO FOLLOW

INSTANT HOT WATER RECIRCULATING SYSTEM

National- Spencer Inc.

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Stenner Pump Chlorinator Installation & Start Up Guide

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

POOL ROVER SERIES 2 ROBOTIC POOL CLEANER PRODUCT SETTINGS AND TROUBLESHOOTING GUIDE

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

1/3 HP Submersible Sump Pump with Vertical Float Switch

HYDRAULIC TABLE CART 500-LB.

P7100 PUMP INSTALLATION INSTRUCTIONS Diesel Care & Performance Inc

Model 1756 Test Lead Kit

BREEZE XLS ROBOTIC POOL CLEANER SETTINGS AND TROUBLESHOOTING GUIDE

INSTRUCTION MANUAL IM042. Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF


VACUUM CLEANER INSTRUCTION MANUAL

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Operation Instructions PowerCool Series

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

Polaris 9300 & 9400 Series Robotic Cleaner

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Installation Instructions

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

Series Hose Reels

Cable Drum Machine. Operation Manual BC260 SERIES. Cleans 1 1/4" to 3" lines up to 50'

HYDRAULIC LIFT TABLE CART 2200-LB.

ColdGuard Bi-PARTING DOOR INSTALLATION INSTRUCTIONS

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Mini Pallet Jack OWNER S MANUAL

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Dehumidifier Users manual. For Models: DH45S DH65S

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

Trouble Shooting. Pump

2006 HEADSHOK Service Video #1

Leak Detection System

Auto-Clean Drain Cleaning Machine

TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9)

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

15GAL STEEL OIL DRAIN WITH 110V PUMP

CARING FOR YOUR WATER HEATER

SunMaxx Solar Filling Station Operating Instructions

20 GALLON WET DRY VACUUM

MODEL RF Drain Cleaning Machine

8" BENCH GRINDER OWNER'S MANUAL

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

PET-10 INSTRUCTION MANUAL PRESSURE TANK

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

ELECTRICAL SAFETY. The standard unit for measuring electrical current.

Jet Propulsion System

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS

INSTALLATION INSTRUCTIONS MULTI-MOUNT KIT Part Number: Application: Warn HP PowerPlant P/N 71800

Service Guide. Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines. ORDER No: UN-SVG001A-EN DATE: October 9, 2007

OSCILLATAP SIEVE SHAKER MANUAL

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

Model No: VS SAFETY INSTRUCTIONS VS INTRODUCTION & APPLICATIONS VS CONTENTS. 2.1 Introduction. 2.

MAC FAUCETS. Owner s Manual. Models: FA444

WARNING WARNING TABLE 1.

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

HAND PUMP OPERATION, SERVICE AND PARTS INSTRUCTION MANUAL

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

MODEL G300 BRAKE BLEEDER

Super Cascade Filtration Systems (CE)

Finding and Fixing Leaks

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

B-AIR BLOWER CUB POWER MODEL # CP-1

ClearView 100. Instruction Manual

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Carpet Washer. vax.co.uk. Rapide Ultra series

This instruction is valid for all ACD pump models shown on page 2

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

Tri-Homo Style Operation and Maintenance Instructions

Drain Cleaning Machine

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Hard Disk Drive (HDD)

SKILL ATTACK PITCHING MACHINE PATENTS APPLIED FOR INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE

Transcription:

Entire document: 7 pages THIS DOCUMENT CONTAINS GENERAL INSTRUCTION FOR SERVICING STENNER PRODUCTS. PLEASE BE SURE TO READ ALL SAFETY INFORMATION. NOTICE: Indicates special instructions or general mandatory action. NOTICE: Read all safety hazards before installing or servicing the pump. The pump is designed for installation and service by properly trained personnel. NOTICE: Use all required personal protective equipment when working on or near a chemical metering pump. NOTICE: Install the pump so that it is in compliance with all national and local plumbing and electrical codes. NOTICE: Use the proper product to treat potable water systems, use only chemicals listed or approved for use. NOTICE: Install the pump to work in conjunction with pool, spa, well pump, or system controls.

Safety Information Classic Page 2 of 7 Warns about hazards that CAN cause death, serious personal injury, or property damage if ignored. ELECTRIC SHOCK HAZARD ELECTRIC SHOCK HAZARD: Pump supplied with grounding power cord and attached plug. To reduce risk of electrical shock, connect only to a properly grounded, grounding type receptacle. Install only on a circuit protected by a ground-fault circuit interrupter (GFCI). AVERTISSEMENT RISQUE DE CHOC ELECTRIQUE: Cette pompe est équipée d une fiche de mise à terre. Pour réduire le risque de choc électrique, s assurer que la fiche est bien raccordée à une prise de courant avec une connexion de mise à terre. Installer seulement sur un circuit proteger par un interrupteur proteger par une mise à la terre. DO NOT alter the power cord or plug end. DO NOT use receptacle adapters. DO NOT use pump with a damaged or altered power cord or plug. Contact the factory or an authorized service facility for repair. HAZARDOUS VOLTAGE: DISCONNECT power cord before removing motor cover for service. Electrical service by trained personnel only. EXPLOSION HAZARD: This pump is not explosion proof. DO NOT install or operate in an explosive environment. RISK OF CHEMICAL EXPOSURE: Potential for chemical burns, fire, explosion, personal injury, or property damage. To reduce risk of exposure, the use of proper personal protective equipment is mandatory. RISK OF FIRE HAZARD: DO NOT install or operate on any flammable surface. RISK OF CHEMICAL OVERDOSE: To reduce risk, follow proper installation methods and recommendations. Check your local codes for additional guidelines. Warns about hazards that WILL or CAN cause minor personal injury or property damage if ignored. PLUMBING: Chemical feed pump installation must always adhere to your local plumbing codes and requirements. Be sure installation does not constitute a cross connection. Check local plumbing codes for guidelines. NOTICE: Indicates special instructions or general mandatory action. NOTICE: This metering pump is portable and designed to be removable from the plumbing system without damage to the connections. NOTICE: This metering pump and its components have been tested for use with the following chemicals: Sodium Hypochlorite (10-15%), Muriatic Acid (20-22% Baume, 31.5% Hcl), and Soda Ash. NOTE: Cette a pompe de dosage et ses composants ont été testés pour utilisation avec les produits chimiques suivants; Hypochlorite de Sodium (solution de 10-15%); Acide Muriatique (20-22% Baume, 31.5% Hcl); Cendre de Soude. This is the safety alert symbol. When displayed in this manual or on the equipment, look for one of the following signal words alerting you to the potential or personal injury or property damage. PUMP SUITABLE FOR USE OUTDOORS when installed with a Stenner Rain Roof Part No. MP90000. Electrical installation should adhere to all national and local codes. Consult a licensed professional for assistance with proper electrical installation. Removing power from pool/spa recirculation pump must also remove power from pump. The use of an auxiliary safety device (not supplied), such as a flow switch or sensor, is recommended to prevent feed pump operation in the event of a recirculation pump failure or if flow is not sensed. Point of chemical injection should be beyond all pumps, filters, and heaters. Suitable for indoor and outdoor use. Convient pour usage intérieur et extérieur..

Safety Information Replace the Pump Tube Page 3 of 7 RISK OF CHEMICAL EXPOSURE: To reduce risk of exposure, check the pump tube regularly for leakage. At the first sign of leakage, replace the pump tube. To reduce risk of exposure, the use of proper personal protective equipment is mandatory when working on or near chemical metering pumps. To reduce risk of exposure, and also prior to service, shipping, or storage, pump generous amounts of water or a compatible buffer solution to remove chemical from pump. Consult chemical manufacturer and MSDS sheet for additional information and precautions for the chemical in use. Personnel should be skilled and trained in the proper safety and handling of the chemicals in use. PINCH POINT HAZARD: Use extreme caution when replacing pump tube. Be careful of your fingers and DO NOT place fingers near rollers. EXPOSURE: HAZARDOUS PRESSURE/CHEMICAL Use caution and bleed off all resident system pressure prior to attempting service or installation. Use caution when disconnecting discharge tubing from pump. Discharge may be under pressure. Tubing may contain chemical. NOTICE: Indicates special instructions or general mandatory action. NOTICE: DO NOT apply grease, oil, or lubricants to the pump tube or housing. NOTICE: Prior to pump tube replacement, inspect the entire pump head for cracks or damaged components. Ensure rollers turn freely. NOTICE: Rinse off chemical residual and clean all chemical and debris from pump head components prior to tube replacement. Apply grease (AquaShield ) to main shaft and tube housing cover bushing during tube replacement. NOTICE: DO NOT pull excessively on pump tube. Avoid kinks or damage during tube installation. NOTICE: Inspect the suction/discharge tubing, injection point (into pipe), and injection check valve duckbill for blockages after any tube rupture. Clear or replace as required. Replace the Pump Tube Preparation 1. Follow all safety precautions prior to tube replacement. 2. Prior to service, pump water or a compatible buffer solution through the pump and suction/discharge line to remove chemical and avoid contact. 3. Turn pump off. 4. Disconnect the suction and discharge connections from pump head. 5. Plug power cord into constantly energized, properly grounded receptacle for service.

Page 4 of 7 BEST PRACTICE Factory recommended: Prior to tube removal, pump water through tube to remove chemical. Remove the Old Pump Tube 1. Turn pump off. 2. Remove and set aside cover and screws. 3. Set feed rate dial on the low setting until finished. 4. Turn pump on and let it run until one of three roller assembly slots lines up with the tube fitting on the suction side. 5. Turn pump off. 6. Lift tube fitting out of housing slot and pull it toward center of roller assembly. 7. Turn pump on and allow roller assembly to jog while guiding tube, with tension, up and out of housing. 8. Turn pump off. Remove and discard pump tube. Slots Pull out

Page 5 of 7 IMPORTANT! Key for optimum performance: Identify the cause of tube failure prior to installing a new tube. After Removing Old Tube 1. Remove roller assembly, shaft, and housing. 2. Use non-citrus all-purpose cleaner to clean chemical residue from pump head housing, roller, and cover. 3. Check housing for cracks and replace if cracked. 4. Ensure rollers spin freely. 5. Replace roller assembly if: seized, excessive side play from bore wear, or if rollers are visibly worn. 6. Inspect the suction/discharge tubing, point of injection, and check valve duckbill for blockages. Clean and/or replace as required. Pull out 7. Reinstall clean housing. 8. Grease shaft tip and install. 9. Install roller assembly. No rocking/tilting Check rollers

Page 6 of 7 Install New Pump Tube 1. Manually rotate the roller assembly counter clockwise to align one of three roller assembly slots with the suction side housing slot. 2. Place tube fitting into suction side slot of the housing and the roller assembly slot. 3. With pump setting on low, hold tube fitting and jog roller assembly by turning pump on. IMPORTANT! Avoid rotating wrist, which can result in a twisted tube that will not center. DO NOT force tube and be careful of your fingers. 4. Guide tube, with slight tension (toward the center) to prevent pinching between housing and roller assembly. Tube housing slot Roller assembly slot IMPORTANT! Key for optimum performance: DO NOT lubricate pump tube or roller assembly. 5. When tube reaches the top housing slot, turn pump off. 6. Turn dial ring to setting 10, hold tube fitting firmly, and turn pump on. NOTE: A used tube will have stretched approximately 3/4" and the new tube will appear to be stiff and short. Follow directions to allow rollers to stretch tube into place. 7. Allow rollers to stretch tube into place while guiding tube into slot. 8. Turn pump off. 9. Apply a small amount of grease (AquaShield ) to cover bushing ONLY and replace cover and two screws, leaving front screw in-between the fittings loose. Guide Guide Turn the pump on, walk tube in. Tube housing slot Roller assembly slot BEST PRACTICE Factory recommended: Trim 1" off suction/discharge tubing before installing ferrules. Replace ferrules with every tube change.

Page 7 of 7 Center the Pump Tube 1. To center pump tube on rollers, set feed rate dial to setting 10. Turn pump on. 2. Turn the tube fitting on the suction side not more than 1/8 of a turn in the direction tube must move. 3. DO NOT let go of fitting until the tube rides approximately in the center of the rollers. NOTE Additional information: If pump head housing screws are stripped, use alternate bosses and position them opposite each other. Use only two at a time. 4. Turn the pump off, let go of fitting, and tighten the cover screws*. The cover is not on securely if there is a gap between the screw boss and the cover. *Screws are self-tapping and must be backed in to locate original threads before securing, to prevent stripping screw boss. 1/8 turn Leave this screw loose. Cover Gap Screw Boss Fixed Rate Pump Tube Change To install a new tube in a fixed rate pump, utilize the on/off switch to jog the roller assembly in absence of the feed rate control.