Datacenter Clarity LC Release Notes. Version 2.3



Similar documents
Datacenter Infrastructure Management (DCIM) Solution

Model Manage Monitor Maximize your Data Center

Product Comparison List

Raritan AMS Series Intelligent Electronic Asset Management

for Sage 100 ERP Business Insights Overview Document

Teamcenter 8.3. Getting Started with Vendor Management. Publication Number PLM00184 B

Bridging the gap for optimized efficiencies and smarter decisions

High density Fiber Optic connections in the Data Center. Phil Ward Datacenter Product Market Manager. HUBER+SUHNER AG

StruxureWare TM Data Center Operation

EMC Smarts Network Configuration Manager

Product Comparison List

How To Buy An Fujitsu Primergy Bx400 S1 Blade Server

Bridging the gap for optimized efficiencies and smarter decisions

New Trading Platform NTP Customer Connectivity Topology Guide

Creating Dashboards. Intellicus Enterprise Reporting and BI Platform. Intellicus Technologies

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

What is a Datacenter?

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

Fujitsu PRIMERGY BX600 S3 Blade Server

Data Center Lifecycle and Energy Efficiency

Third-party software is copyrighted and licensed from Kofax s suppliers. This product is protected by U.S. Patent No. 5,159,667.

Monitoring Inventory. Inventory Management. This chapter includes the following sections:

Storage System. Planning Checklist. EC E1, First Edition

What's New Feature Guide

GeneMapper ID-X Software Version 1.0

Custom Reporting System User Guide

Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server

Using CFD for optimal thermal management and cooling design in data centers

HUBER+SUHNER AG Phil Ward

ServerView Inventory Manager

COGNOS Query Studio Ad Hoc Reporting

ArcSight Express Administration and Operations Course

Data Center Connector for OpenStack

Data Center Infrastructure Management: Improve Data Center Capacity Utilization

Administration Guide. . All right reserved. For more information about Specops Inventory and other Specops products, visit

Energy Communication Unit (ECU)

Distributing Power to Blade Servers

The open source enterprise solution pre-configured for the IT Asset Management

SAS BI Dashboard 4.3. User's Guide. SAS Documentation

Kokii BatteryDAQ. BMS Software Manual. Battery Analyzer Battery DAS

Data Center Cabling Design Trends

Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server

Using the Drag-and-Drop Report Builder

Teamcenter Getting Started with Teamcenter. Publication Number PLM00002 J

use ready 2 The open source enterprise solution pre-configured for the IT Asset Management Tecnoteca Srl

WebSphere Business Monitor

Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications

Visualizing Data Center Capacity with Visio

Data Center Infrastructure Management: How to Optimize Data Center Operations

TIBCO Spotfire Business Author Essentials Quick Reference Guide. Table of contents:

Meraki MX50 Hardware Installation Guide

User's Guide. ControlPoint. Change Manager (Advanced Copy) SharePoint Migration. v. 4.0

Lesson 9. Reports. 1. Create a Visual Report. Create a visual report. Customize a visual report. Create a visual report template.

Rosetta Course. Rosetta Stone Manager Administrator's Guide Copyright 2012 Rosetta Stone Ltd. All rights reserved

Simplifying Data Center Network Architecture: Collapsing the Tiers

White paper Power Consumption Monitoring of PRIMERGY Servers in System Center Operations Manager

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

Building Microsoft Windows Server 2012 Clusters on the Dell PowerEdge VRTX

Ovation Operator Workstation for Microsoft Windows Operating System Data Sheet

Supporting Cisco Switches In Hot Aisle/Cold Aisle Data Centers

Advanced planning / change impact features

Lab Validation Report. Leo Nguyen. Month Year

PowerLogic ION Enterprise 5.6

ORACLE BUSINESS INTELLIGENCE WORKSHOP

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Installing Policy Patrol on a separate machine

Symantec Database Security and Audit 3100 Series Appliance. Getting Started Guide

PE8216/PE8324. Energy Intelligence Solutions

Data center lifecycle and energy efficiency

Emerson Smart Firewall

This Readme includes information pertaining to Novell Service Desk 7.0.

How To Power A Bladecenter H Servers

Oracle Fusion Middleware User s Guide for Oracle Approval Management for Microsoft Excel 11gRelease 1 ( )

S&C IntelliTeam CNMS Communication Network Management System Table of Contents Overview Topology

Oracle Utilities Meter Data Management Business Intelligence

HP Server Management Packs for Microsoft System Center Essentials User Guide

CHAPTER 4: BUSINESS ANALYTICS

Spec Sheet. Cisco R42610 Rack CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, REV A.6 DECEMBER 9,

The Need for Speed Drives High-Density OM3/OM4 Optical Connectivity in the Data Center

Raritan AMS Series Intelligent Electronic Asset Management

WebSphere Business Monitor V6.2 Business space dashboards

Using SQL Reporting Services with Amicus

SAP BusinessObjects Business Intelligence Platform Document Version: 4.1 Support Package Business Intelligence Launch Pad User Guide

Last Updated on 11/06/

McAfee Enterprise Security Manager 9.3.2

GRAPHISOFT ArchiCAD and COBie2. How to Prepare your ArchiCAD 17 Project for COBie2 Documentation

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

HP Service Manager. Software Version: 9.40 For the supported Windows and Linux operating systems. Application Setup help topics for printing

Reporting. Microsoft Dynamics GP enterpri se. Dynamics GP. Christopher Liley. Create and manage business reports with.

Energy Communication Unit (ECU)

SAP BusinessObjects Financial Consolidation Web User Guide

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

Management Reporter Integration Guide for Microsoft Dynamics AX

ARCHITECTURAL PARTNERS, P.C. 10 Ninth Street, Lynchburg, Va / Fax 434/

Business Portal for Microsoft Dynamics GP Key Performance Indicators

Preparing for Your First DCIM System Deployment: Auto-Discovery and Data Collection

Transcription:

Datacenter Clarity LC Release Notes Version 2.3

Table of Contents Introduction... 5 What's New in 2.3... 6 Dashboard Builder... 6 Electrical Layout... 6 Report Management... 6 Access management and user permission enhancements... 6 Automatic generation of reports in the Asset Management Environment... 7 Non-standard rack support... 7 Additional in-rack PDU placement methods... 7 Allowing modification of port type/category for modular/pluggable devices... 7 Additional attributes supported by attribute configurations... 8 Advanced search improvements... 8 EMIP entry validation... 8 Enhancements... 9 DCSCS-453: Patch panel network port type default creation to be LCD instead of LC.... 9 DCSCS-473: Addition Ports needed... 9 DCSCS-386: Web client EMIP library advanced search does not reset... 9 DCSCS-305: square lines in the 2D electrical viewer... 10 DCSCS-284: have 'advanced search' option added to all searches... 10 DCSCS-324: Additional (fiber) connector types... 10 DCSCS-387: emip export not grabbing right selection... 11 DCSCS-326: Names should be ordered in the 3D navigator... 11 DCSCS-304: web client EMIP library - comparison view Text... 11 DCSCS-47: 2D diagram should show the location of the asset... 11 DCSCS-21: Web client EMIP new entry: validate attributes... 11 DCSCS-20: Web client EMIP library new entry: list mandatory attributes... 11 DCSCS-22: web client EMIP new entry: contextual menus... 12 DCSCS-12: Automatic generation of reports in TC... 12 DCSCS-150: Concept of SFPs is not supported... 12 DCSCS-159: Single Line Diagram including status of switchgear... 12 DCSCS-277: Web client electrical layout similar to network layout... 13 DCSCS-182: Autoconnect function in NX Edit Dialog is not called if asset is not moved/edited... 13 DCSCS-482: publish NX 4D reports to web client... 13 DCSCS-352: Decals to NX don't work for Custom EMIP entries... 13 DCSCS-480: Commissioning guide 2.2.2... 13 Resolved bugs... 14 DCSCS-347: Can't create city under a country... 14

DCSCS-437: user cannot add patch panel blade to out of rack blade chassis... 15 DCSCS-447: LC Duplex port can't connect in web client... 15 DCSCS-542: Dimensions on EMIP connectors only accept numbers without digits... 15 DCSCS-538: Client customisations should not be in install package... 15 Copyright 2015 Maya Heat Transfer Technologies Ltd. All Rights Reserved 3

Proprietary and restricted rights notice This software and related documentation are proprietary to Maya Heat Transfer Technologies Ltd. Copyright 2016 Maya Heat Transfer Technologies Ltd. All Rights Reserved. Datacenter Clarity LC Powered by Teamcenter TM Software from Siemens. All trademarks belong to their respective holders. Teamcenter TM and NX are trademarks or registered trademarks of Siemens Product Lifecycle Management Software Inc. or its subsidiaries in the United States and in other countries. Copyright 2015 Maya Heat Transfer Technologies Ltd. All Rights Reserved 4

Introduction This document describes the following: New features introduced in Datacenter Clarity LC version 2.3 Enhancements made to Datacenter Clarity LC. Known software issues that have been resolved in this release. Copyright 2015 Maya Heat Transfer Technologies Ltd. All Rights Reserved 5

What's New in 2.3 Dashboard Builder Datacenter Clarity LC web client now has a new module: Dashboard Builder. Using the Dashboard Builder module, you can create customized single or multi-asset dashboards that you can view in the Dashboard Navigator module. In the Dashboard Builder module, you can create the following dashboard widgets for a custom dashboard: Text displays text and images in a text pane. Graph displays real-time and asynchronous attribute data in a trend chart format. Real-time Table displays real-time attribute values in a table format. For more information, see Dashboard Builder in the web client help files. Electrical Layout Datacenter Clarity LC web client now has a new module: Electrical Layout. In the Electrical Layout, you can display a two-dimensional diagram that represents the chain of electrical connections in your 3D model. The electrical diagram lets you identify the power and current capacity across the model. For more information, see Electrical Layout in the web client help files. Report Management Datacenter Clarity LC web client now has a new module: Report Management. Report Management provides standard report definitions that you can use to generate and manage asset reports for your datacenter. You can also download the report to an Excel spreadsheet. For more information, see Report Management in the web client help files. Access management and user permission enhancements Only database administrators have access to the Local Users module from which they manage Datacenter Clarity LC web client's users and roles. You can now grant user permissions for all web client modules from the Access Management module. In the Local Users module, you can change the Teamcenter super user. This user has access management administrator permissions and access to ACL permissions. In previous versions, the Local Users module was named the Users & Roles module. Copyright 2015 Maya Heat Transfer Technologies Ltd. All Rights Reserved 6

The user interface of the Access Management module is improved. For more information, see Access Management and Local Users in the web client help files. Automatic generation of reports in the Asset Management Environment The automatic reports service can now generate reports for assets modified or created in the last day, week, month, or year directly in the Asset Management Environment. After the software generates the report and saves it in the specified folder, you receive an email in your Datacenter Clarity LC Worklist mailbox. For more information, see Automatic reporting in the web client help files. Non-standard rack support Datacenter Clarity LC supports non-standard racks. You can configure the height of the 1U using the ASSET RACK ONE U SPACE HEIGHT attribute in the EMIP library. Additional in-rack PDU placement methods Datacenter Clarity LC supports additional in-rack PDU placement methods. When you place in-rack PDUs on a rack wall, you can now place them in the following positions: On the left or right of the front of the rack. Two side-by-side positions on the left or right of the back of the rack. For more information, see Create/Edit Asset in the Datacenter Clarity LC User Reference help files. Allowing modification of port type/category for modular/pluggable devices You can now change the port type/category as long as the port type follows these patterns: "SFP/***", "SFP+/***", "XFP/***", "GBIC/***". You can now plug in a new module to an existing server and select the port type and category after you created this server in Datacenter Clarity LC. For more information, see: Network Ports Manager in the 3D Modeling Environment section of the Datacenter Clarity LC User Reference help files. Create/Edit Port in the Asset Management Environment section of the Datacenter Clarity LC User Reference help files. Copyright 2015 Maya Heat Transfer Technologies Ltd. All Rights Reserved 7

Additional attributes supported by attribute configurations You can override the following attributes through attribute configurations: ASSET APPARENT POWER ASSET COOLING CAPACITY ASSET CURRENT NUMBER OF PHASES ASSET CURRENT TYPE ASSET DE-RATED CURRENT ASSET EFFICIENCY ASSET MAX CURRENT ASSET POWER FACTOR ASSET VENDOR DE-RATED POWER ASSET VENDOR MAX POWER ASSET VOLTAGE Advanced search improvements The following advanced search improvements are introduced in the web client: The list of available Datacenter Clarity LC filters is now related to the module you are searching in. For example, in the Dashboard Builder module, when you use the Advanced search the filter options are applicable to dashboards, such as dashboard name, author, creation date, and ID. You can create custom filters combining saved search queries. More pre-defined filters are added to the list of Datacenter Clarity LC filters. For more information, see Searching Datacenter Clarity LC web client. EMIP entry validation Datacenter Clarity LC now validates EMIP entries as you create them. Copyright 2015 Maya Heat Transfer Technologies Ltd. All Rights Reserved 8

Enhancements DCSCS-453: Patch panel network port type default creation to be LCD instead of LC. Datacenter Clarity LC now uses LCD (Lucent Connector Duplex) as the default port type for all in-rack assets and connections to patch panels. DCSCS-473: Addition Ports needed The following port types have been added to Datacenter Clarity LC: Emily (Copper) RP-BUS (Copper) DCSCS-278: Network cable mgt related reports for batch renaming To help you manage changes to the port names, Datacenter Clarity LC provides the Clarity Asset Related Ports report in both the web client and Teamcenter. The report includes the following information: Parent Asset Parent Asset ID Parent Asset Serial Number Parent Network Card Parent Network Card ID Port ID Port Name Port Type Port Category Port Description Stream End Connected Asset Connected Asset ID Connected Network Card Connected Network Card ID Connected Port Connected Port ID End Asset End Port Cable Cable ID VLAN Port Status DCSCS-386: Web client EMIP library advanced search does not reset Previously, the EMIP Library Advanced Search dialog box displayed attribute values from previous searches. Now, when you open the EMIP Library Advanced Search dialog box, all previous search criteria has been removed. Copyright 2015 Maya Heat Transfer Technologies Ltd. All Rights Reserved 9

DCSCS-305: square lines in the 2D electrical viewer Using the Datacenter Clarity LC s web client Electrical Layout module, you can specify the type of flow line that connects the assets: Orthogonal Diagonal Smooth Straight You can also specify the type of cable edge that displays: Straight or Rounded. DCSCS-284: have 'advanced search' option added to all searches This issue has been resolved with the enhancements made to the Advanced Search in the web client. For more information see Advanced search improvements in the What s New section. DCSCS-470: more electrical sockets needed Datacenter Clarity LC now includes the following socket types: IEC 60309 316 IEC 60309 516 IEC 60309 532 DCSCS-324: Additional (fiber) connector types Datacenter Clarity LC now includes the following fiber connector types: SC/APC LC/APC FC/APC MTP E2000/APC DIN Copyright 2015 Maya Heat Transfer Technologies Ltd. All Rights Reserved 10

DCSCS-387: emip export not grabbing right selection Previously, when you generated a query in the EMIP library Equipment List, for the purpose of creating an export file, and the query did not generate any search results, you could still import and download a CSV file. Datacenter Clarity LC populated the file with all the assets that were not created by Maya. Now, when a query does not produce any search results in the Equipment List, you cannot download the CSV file. DCSCS-326: Names should be ordered in the 3D navigator Asset names are now ordered alphabetically in the 3D Viewer s Navigator. DCSCS-304: web client EMIP library - comparison view Text You can now compare different EMIP entry attributes in the EMIP library. The EMIP library includes a new page: the EMIP Entry Comparison page, which identifies the attributes that are the same in the EMIP entries and those that are different. For more information see Navigating the EMIP Library in the web client help files. DCSCS-47: 2D diagram should show the location of the asset In the Datacenter Clarity LC s web client Electrical Layout module, you can now view twodimensional diagrams that represent the chain of electrical connections in your 3D model. For more information, see Electrical Layout in the web client help files. DCSCS-21: Web client EMIP new entry: validate attributes Datacenter Clarity LC now validates EMIP entries as you create them. Fields that require a mandatory attribute value display an error message when you enter an invalid attribute value. The error message lists the required values. DCSCS-20: Web client EMIP library new entry: list mandatory attributes Resolved as described in DCSCS-21: Web client EMIP new entry: validate attributes. Copyright 2015 Maya Heat Transfer Technologies Ltd. All Rights Reserved 11

DCSCS-22: web client EMIP new entry: contextual menus As described in DCSCS-21: Web client EMIP new entry: validate attributes, Datacenter Clarity LC validates and displays EMIP entries in an error message. The EMIP menus are not contextual, but you are advised in a message box when you enter an invalid value. You can add as many rules as you require. This is a commissioning task. DCSCS-12: Automatic generation of reports in TC This issue has been resolved with the new automatic reports service in Datacenter Clarity LC. For more information see Automatic generation of reports in the Asset Management Environment in the What s New section. DCSCS-150: Concept of SFPs is not supported To support modular/pluggable devices, such as SFP, SFP+, XFP, and GBIC Datacenter Clarity LC now lets you modify the port type and category when the port type is: GBIC/LC GBIC/LCD GBIC/PC GBIC/PCD SFP+/LC SFP+/LCD SFP+/PC SFP+/Unknown SFP/LC SFP/LCD SFP/PC SFP/Unknown GBIC/Unknown Datacenter Clarity LC has changed the following connector types: Migration Previous connector type Changed to Category Type Category Type Copper GBIC Copper GBIC/Unknown Fiber GBIC Fiber GBIC/Unknown Copper SFP Copper SFP/RJ-45 Fiber SFP Fiber SFP/Unknown DCSCS-159: Single Line Diagram including status of switchgear This issue has been resolved with the new Electrical Layout module. Refer to Electrical Layout in the What s New section for more information. Copyright 2015 Maya Heat Transfer Technologies Ltd. All Rights Reserved 12

DCSCS-277: Web client electrical layout similar to network layout The Electrical Layout module has been added to Datacenter Clarity LC s web client, which is similar to the Network Layout module. The Electrical Layout module displays a two-dimensional diagram that represents the chain of electrical connections in your 3D model. The Electrical Layout diagram displays asset and electrical attribute information and realtime data on the assets input power or current. For more information, see Electrical Layout in the in the web client help files. DCSCS-182: Autoconnect function in NX Edit Dialog is not called if asset is not moved/edited Previously, when an asset was edited, but not moved in the model, the Autoconnect tool was not available. Now when an asset is edited, but not moved, Datacenter Clarity LC checks if the asset is connected: If no connections were made, Auto Connect is enabled and Datacenter Clarity LC makes the connections. If connections were made, Auto Connect is disabled. DCSCS-482: publish NX 4D reports to web client Task instructions for configuring 4D reports have been added to the Commissioning Guide for this release. DCSCS-352: Decals to NX don't work for Custom EMIP entries To ensure that custom front and back decal jpg and png image files are added to EMIP entries, instructions were added to the 3D Model Viewer Tools page in the Datacenter Clarity LC User Reference help files that explains standard practices for naming these file types. DCSCS-480: Commissioning guide 2.2.2 The Commissioning guide task instructions for building the 3D Modeling and creating the Real-Estate Structure has been updated. Copyright 2015 Maya Heat Transfer Technologies Ltd. All Rights Reserved 13

Resolved bugs DCSCS-347: Can't create city under a country Previously the Create Real Estate Structure commissioning tool let you create (ordered) real-estate assets with any number of gaps in the hierarchy, such as a structure with only two levels: a company asset and a room asset. Datacenter Clarity LC now requires that you create a site asset if you want to add any of the following assets: Building Roof Floor In addition, you cannot add any one of the following assets without first creating a room asset: Zone Row Floor-mounted-assets Copyright 2015 Maya Heat Transfer Technologies Ltd. All Rights Reserved 14

You are not required to create each of the listed assets, but must create the required assets to place anyone of the child assets in the 3D model. Due to the changes made to the Create Real Estate Structure commissioning tool, the Create/Edit Asset dialog is now more flexible. Previously, you could only install an asset below the immediate next logical real-estate level. For example, you could create a building asset under a site asset but you could not create a floor asset under a site asset. Now, the Create/Edit Asset dialog box adheres to the same rules used by the Create Real Estate Structure commissioning tool. You must follow these rules when performing a batch asset import. For more information see Asset hierarchy configuration in the Datacenter Clarity LC User Reference help files. DCSCS-437: user cannot add patch panel blade to out of rack blade chassis Previously you could only place a blade in patch panels (defined as blade chassis in Datacenter Clarity LC) that were rack-mounted. Now, you can now place a blade in patch panels that are: Surface-mounted Floor-mounted Tile mounted DCSCS-447: LC Duplex port can't connect in web client Datacenter Clarity LC can now make connections between LCD ports. DCSCS-542: Dimensions on EMIP connectors only accept numbers without digits Now, when you add or modify attribute values in the EMIP Entry Attributes table, Datacenter Clarity accepts decimal points. DCSCS-538: Client customisations should not be in install package Installation configuration files no longer include code for customized Datacenter Clarity LC installations. Copyright 2015 Maya Heat Transfer Technologies Ltd. All Rights Reserved 15

DCSCS-575: EMIP import tool does not detect change when changing attribute from lower to uppercase Previously, when Datacenter Clarity LC imported equipment definitions, using the EMIP Import tool and the given file only included one modification to attributes, a change in case from lower to uppercase, Datacenter Clarity LC did not implement this change. Now, Datacenter Clarity LC changes the case, when required. Copyright 2015 Maya Heat Transfer Technologies Ltd. All Rights Reserved 16