Sump Systems for Basements



Similar documents
CAVITY DRAIN MEMBRANE SYSTEMS: SUMPS AND PUMPS GUIDANCE NOTES

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

Waterproofing Solutions

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

The most advanced Undersink Sullage System with inbuilt controls and alarms.

Safeguard Waterproofing Systems. Creating useable. living space. by making basements dry

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Internal Basement Waterproofing Newton System 500

PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems

The Guide To Waterproofing An Existing Basement

Why Homeowners Need a Backup Sump Pump System

Basement Waterproofing in Existing Buildings

PUMPSTOR COMPLETE WASTE WATER AND SURFACE WATER PUMPING SOLUTIONS

Risk Management Guidelines

Pumped Drainage DELTA MEMBRANE SYSTEMS LTD

Extreme Wet Weather in Brookfield. How to Keep Your Basement Dry During Heavy Rains and Floods

Rainwater is directed away from walls at surface. Any water infiltrating is captured in drains below foundation

Conlift1, Conlift2, Conlift2 ph+

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

Concrete Waterproofing Systems. Integral Protection.

Flood Reduction Strategies in the City of Ottawa. Presented by : Eric Tousignant, P.Eng Senior Water Resources Engineer, City of Ottawa

City of Edmonton Page 1 of 5 Foundation Drain Discharge Collection System Guideline November, 2005

Protecting what matters

CERTIFYING DRAINLAYER

Protecting what matters

Geberit Pluvia siphonic roof drainage system. Stands up to every kind of rainfall

CREATING EFFECTIVE WATERPROOFING & DRAINAGE FOR INTERIOR WALLS. Using Oldroyd Xv clear, Xv20 and Xp on interior walls

Appendix B. Property Owner Questionnaire

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Uniclass L L2123 EPIC J3413. CI/SfB (52.5) Heavy duty channel drainage system ACO S Range

WaterCress - Critical Infrastructure Protection

9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES. Hunter Underground Systems

SUMP PUMP DISCHARGES INFORMATIONAL PACKET

CHAPTER 11 STORM DRAINAGE

Preventing water damage in the basement

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Protect Your Home From Flooding. A guide for Lethbridge Residents

OVER-HEAD SEWER ASSISTANCE GRANT

Ground Gas Barriers.

E nv i ro n m e nta l. Biotec 5-7. Sustainable, Reliable, Affordable

INDUSTRY GUIDANCE FOR INSTALLERS ON CONDENSATE DRAINAGE PIPE INSTALLATION. This guidance is endorsed by HHIC members.

Extra. Technical. November 2014 Issue 16 NHBC STANDARDS GUIDANCE AND GOOD PRACTICE. In this issue:

Proposed Construction of Basement Flood Risk Assessment. 35 Edwardes Square London W8 6HH

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Ridgistorm-XL - the latest innovative

Homeowner s Guide Foundation Water PenetrationTips TIPS TO IDENTIFY WATER PENETRATION PROBLEMS / CRACKING BASEMENTS

Utilities and existing services

Blowdown vessels Meeting the requirements of HSE PM60

Village of Rantoul Backwater Valve Program

SANITARY SEWER BACKUP. Causes & Prevention

DISTRICT OF COLUMBIA WATER AND SEWER AUTHORITY. a guide to PREVENTING SEWER BACKUPS AND FLOODING

DUBLIN CITY COUNCIL FLOOD FORUM

Link-Up. Solid Fuel Association Guide to Central Heating.

BIODISC HIGH PERFORMANCE SEWAGE TREATMENT PLANT FOR DOMESTIC APPLICATIONS

good to know... SEWER BACKUP A guide to protecting your home

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

SEPTIC TANK SYSTEMS. Single purpose septic tank receives toilet wastes (blackwater) or sullage (greywater) only.

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

save water, save money, save the environment Monsoon domestic rainwater harvesting systems

AIR DEHUMIDIFYING Condensation drying for industry and trade

SECTION 18 Kingspan Environmental

How To Use A Hydraway System

BASEMENT FLOODING. Prevention Guide for. Homeowners

Leica DIGISYSTEM TM Safe and fast location of underground services

SEPTIC TANKS AND SOAKAWAYS TO HOUSES AND THE BUILDING REGULATIONS

How To Get A Flood Risk Reduction Rebate

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD NORTH RIDGEVILLE, OH (440)

Frequent occurrences of basement flooding can result in long-term damage to the building and equipment that may not be covered by insurance.

bout your HOUSE Avoiding Basement Flooding CE 50

LC/LCD ranges level controllers

Tree Pits Operation & Maintenance Guide

REGISTRATION EXAMINATION, JUNE 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

WATER DAMAGE RISKS GLOBAL CONSULTING. from Weather, Flood and Piped- Water Hazards. Introduction

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

minimum deductible may be increased significantly.

STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION SOURCES OF MOISTURE IN NEW CONSTRUCTION. Natural ground slope

Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options

Domestic Wastewater Treatment Up to 6 Population (6PE)

CHAPTER 11 STORM DRAINAGE

SUMP PUMP. Sump Pump Backup Systems. City of Ann Arbor B A C K U P O P T I O N S. Does everyone need a backup system?

Best Practice Guidance Type C Waterproofing Systems. Issued March 2015

Additional Services Agreement. Part 3: Schedule of our requirements

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Understanding and Caring for Your Septic System

Review of Footing Drain Disconnection Projects

Issue of the Guidelines on Prevention of Water Seepage in New Buildings

Downspout to storm sewer. Leaky laterals

The Town of Lakeshore Basement Flooding Information to Residents

ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R Lecturer: Jim Cahill

September September Consulting Structural and Civil Engineers. 100 St John Street London EC1M 4EH. akt-uk.com

CONVERSION & DEVELOPMENT WATERPROOFING BASEMENTS

Protect your. home from. basement. have you done everything you can?

Transcription:

Sump Systems for Basements

The need for a Sump and Pump Internally applied cavity drainage systems (e.g Oldroyd) are an increasingly popular choice for waterproofing new and existing basements. Instead of physically holding back water pressure (like traditional tanked systems), these systems divert any groundwater passing through the fabric of the building to a suitable discharge point usually a sump and pump. The sump and pump forms the heart of the drainage system so it is essential that it is of a high quality and capacity in order to cope with anticipated levels of water entering the basement. The Safeguard Sentry TM range of sumps, pumps and accessories have been designed with this in mind in conjunction with pump specialist Edincare to provide a solution for basements of any size. BS8102 and Dry Basements In situations where a property owner believes that their basement is merely damp and has never flooded, the necessity for a sump and pump is often questioned or ignored. However, it should be noted that the British Standard that covers basement waterproofing (BS8102) states that it must be assumed that water will come to bear against the basement (or the structure) at some point during its lifetime. For this reason, professional basement waterproofing companies are likely to insist that a sump and pump is included as part of any cavity drainage basement waterproofing system. Furthermore, failure to incorporate an adequate form of drainage (usually in the form of a sump and pump) is likely to affect the validity of any insurance-backed guarantee issued to cover the basement waterproofing system. Sentry TM Sump Systems being used as part of a basement cavity drainage system. Safeguard Sump Systems No mechanical sump and pump system can ever be 100% risk free. However by using high quality components and through thoughtful design, the risk can be minimised. For this reason, all Safeguard sump systems benefit from the following features: Large 100 litre capacity sump chamber High capacity Ama Drainer 303 pumps Dual power mains/battery alarm Ama Drainer 303 pumps have been chosen because of their high engineering standards and high capacity discharge capabilities. These pumps can provide high pumping capacity even in situations where water needs to be discharged several metres above pump level (a common requirement in basement situations). Which Sump and Pump System Should I Choose? The choice of sump system essentially comes down to two major considerations: Anticipated water ingress Potential consequences of the basement flooding (risk versus cost) Whilst our entry level Sentry TM Single System is likely to be sufficient for most domestic basements, homeowners may wish to consider the Sentry TM BB model which benefits from an additional battery powered pump which can function for a period of time in the event of a power cut. Where additional security is required or where higher than normal levels of water ingress are anticipated (such as in larger basements) the Sentry TM Twin model may be preferred to provide enhanced backup and/or additional pumping capacity. Where particularly high levels of water ingress are anticipated, several sumps and pumps may be required. Your basement waterproofing contractor will be able to suggest the most appropriate solution for your basement. Aquadrain Drainage Channel Aquadrain perimeter drainage channel is laid around the perimeter of the basement at the floor-wall junction and is designed to direct water to the Sentry TM sump chamber and pump. Maintenance Pumps are mechanical items, and as such, require regular servicing if they are to continue to perform to their optimum capabilities. Professional basement waterproofing companies offer pump service contracts and are able to advise on an appropriate service interval. For further details, or to discuss a particular project, please contact our technical department on: 01403 210204 or visit our website at: www.safeguardeurope.com BS8102:1990 Code of Practice for protection of structures against water from the ground. ISBN 0580 17897 8

Six reasons for choosing SentryTM Sump Systems: 1 2 3 4 5 6 1: Aquadrain Inlet Socket Pre-formed inlet socket for easy installation of Aquadrain drainage channel system. 2: Full-size 1 1 4 Output Pipe Allows pump to work at full capacity. Integral quick fit connectors allow rapid installation of internal pipework. 3: Tough 100 litre Capacity Chamber Reduces the frequency that the pump is activated prolonging the life of the pump. Manufactured from robust impact-resistant polyethylene. 4: Integral Fixing Bracket For easy internal fixing of float switches. 5: High Capacity Sump Pump High specification Ama Drainer 303 Sump Pump. 6: Raised, grooved step Raised step for backup pump is grooved to act as a silt trap.

The SentryTM range of Sump Systems... Sentry TM Single Pump System 1: The standard Sentry TM Single System has been designed to suit typical domestic basement waterproofing projects*. The Sentry TM Single System benefits from a large 100 litre sump chamber, an Ama Drainer 303 pump and a dual power alarm. All internal plumbing is supplied. The sump chamber has been specifically designed for basement waterproofing applications and benefits from a 450mm x 450mm square opening allowing standard sized access covers to be used. Standard System includes: Sentry TM Sump Chamber 1 x Ama Drainer 303 High Capacity Pump 1 x Dual Power Alarm 1 x Access Cover Sentry TM Twin Pump System 2: The Sentry TM Twin Pump System is designed for situations where a higher level of water ingress is anticipated for example, on larger basement projects or where additional backup is required. Two pumps provide additional pumping capacity and backup (in the event of failure of one of the pumps). The pumps are set at different levels in the sump chamber to help balance the demand between the two pumps minimising the stress put on each pump. Dual outlet pipes allow pumps to operate at full capacity. Twin System includes: Sentry TM Sump Chamber 2 x Ama Drainer 303 High Capacity Pump 1 x Dual Power Alarm 1 x Access Cover Sentry TM BB Pump System 3: (Battery Backup) The Sentry TM BB System has the same benefits and efficiency of the standard Sentry TM Single System with the added reassurance of a Battery Backup pump in the event of a failure such as a power cut. This ensures that the sump is able to operate for a period of time allowing peace of mind against the risks of flooding, especially when power failure is more common in times of heavy storm weather. Battery Backup System includes: Sentry TM Sump Chamber 1 x Ama Drainer 303 High Capacity Pump 1 x 24V Battery Backup Pump 1 x Dual Power Alarm (incorporated in pump control panel) 1 x Access Cover

SentryTM Sump System Components... Dual Power Alarm System Reassurance Mains/battery high-level alarm module (included with the Sentry TM Single and Sentry TM Twin sump systems). Ama Drainer 303 Pump Performance All the Sentry TM Sump Systems utilise the same Ama Drainer 303 high capacity pumps benefiting from the following features: Quiet operation. Built-in non-return valve. High flow rate. Ama Drainer 303 Specification: Power Supply 230V/1/50Hz Outlet Diameter 1 1 4 Solids 10mm Maximum Flow Rate 200 Litres/min Head of Water 12 metres Full pump specifications available on request. Flow rate against head of water Head (metres) 12 m 10 m 8 m All models in the Sentry TM range feature Edincare dual power alarms as standard. These alarms run on mains power, but switch to battery power in the event of a power cut or other mains failure. The battery is tricklecharged and will last for several years before it needs replacing. The alarm is triggered if the water rises above the normal operating level. On the Sentry TM BB model the dual power alarm is incorporated into the control panel (see below). Battery Backup Pump Option The Sentry TM BB sump system includes a battery-powered backup pump, dual power alarm and control unit. This allows water to be pumped away for a period of time in the event of a power cut or failure of the primary pump. The system is triggered if the water rises above the normal operating level within the sump chamber, activating the alarm and 24V battery-powered backup pump. A full technical specification is available on request. Battery backup module incorporating mains/battery alarm (included with the Sentry TM BB sump system). For further details, or to discuss a particular project, please contact our technical department on: 01403 210204 or visit our website at: www.safeguardeurope.com 6 m 4 m 2 m 0 m 25 lpm 50 lpm 75 lpm 100 lpm 125 lpm 150 lpm 175 lpm 200 lpm Flow Rate ( Litres per minute) * Where consequences of water entering the basement are severe, consideration should be given to a backup system such as the Sentry TM Twin and Sentry TM BB sump systems. Your basement waterproofing contractor will be able to suggest the most appropriate system for your basement. As we are continually making improvements to our range, actual supplied units may vary slightly from illustrations.

Making Basements Dry... More information from Safeguard: Architects and Specifiers To assist architects in the specification of our basement waterproofing systems, NBS clauses and CAD details are available on our website: www.safeguardeurope.com. In addition, we offer two RIBA-approved CPD seminars entitled Waterproofing Existing Basements and Waterproofing Basements and Underground Structures (Newbuild). Installation We recommend that Safeguard waterproofing products are installed by an experienced waterproofing company. If you would like a quote for having your basement waterproofed or converted, please call: 01403 210204 Our technical department are able to assist in the specification process, and, on larger projects, site visits can be arranged. Please call: 01403 210204 Redkiln Close. Redkiln Way. Horsham. Sussex. RH13 5QL. UK T +44 (0) 1403 210204 F +44 (0) 1403 217529 E info@safeguardeurope.com WWW.safeguardeurope.com 2007 Safeguard Europe Ltd. 10/07 Design & Print Creative Services: 01444 480491