Manual Code VR-197-0-0002



Similar documents
SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Portable Air Conditioner

ECOCIAT. Domestic hot water heat recovery unit

Transformer oil cooler ALFA A02

USER S MANUAL HSC-24A

CRAC Precision climate control units for data centres

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

SWIMMING POOL HEAT PUMP

Use and Care Manual. Model CPA12KH AIR CONDITIONER

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

PORTABLE AIR CONDITIONER

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

WINDOW ROOM AIR CONDITIONER

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

, User s Manual

Meaco 30L and Meaco 40L dehumidifier instruction manual

Central Air Conditioner

Installation, operation and maintenance manual TX 35A

ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t.

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Troubleshooting Your Refrigerator

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Oil and Coolant Circulating Heating System. Model - OCSM

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

Cooktop Low-Profile Ventilation Hoods

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

AIR CONDITIONER INSTALLATION MANUAL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

LOBOY 16 AIR CONDITIONERS

Roof Top Unit. Description Model Type Use With Air Distribution Box. Heat Pump B Integral Mechanical

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Failure code manual. content

RPV - RP - RA air handling units

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS


Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Table of Contents. 1 - Specifications Installation Wiring User controls...7

Operating Instructions Split System Air Conditioner

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

PORTABLE AIR CONDITIONER

HEATER, AIR CONDITIONING AND VENTILATION

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

marine/bespoke split applications

HERZ-Thermal Actuators

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

IMPORTANT SAFETY RULES TO FOLLOW

SWIMMING POOL HEAT PUMP Owners Manual

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

Heat Pump Water Heater IOM Manual

SF15K SF05KSS, SF10KSS

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

ALL IN ONE. Heat Pump Water Heater

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

NSN

Dehumidifier D 850E. - Instruction manual version 02

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Instruction manual for Firstline FCS12000CH

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Dehumidifier Users manual. For Models: DH45S DH65S

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI

MEMBRANE VACUUM MINI PUMPS

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

Wine Cooler with Thermo-Electric Cooling & Heating Technology

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Air Conditioner B B

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

T-Series Air Conditioner T62 Model

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Ceiling Mount Air Handler Manual

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N

Taurus Series YORK Window Air Conditioners

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

HP switch LP switch Discharge thermo Comp. Surface thermo

INFRARED QUARTZ WALL HEATER

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

AIR-CONDITIONER SPLIT TYPE

Transcription:

USE, MAINTENANCE AND INSTALLATION MANUAL AIR CONDITIONERS FOR ELECTRICAL ENCLOSURES Manual Code VR-197-0-0002 VZ1550 VZ1850 VZ1400 VZ2000 ABB SACE S.p.A. An ABB Group Company Automation and Distribution Boards 23846 Garbagnate Monastero (LC) Tel.: ++39 031 3570 1 - Telefax: ++39 031 3570 228 http://www.abb.com Date: 05-may-06 ABB SACE S.p.A. SERIE VZ Page 1 of 21

ABSTRACT VZ SERIES AIR CONDITIONING UNIT 1 REFERENCE NORMS AND SYMBOLS DESCRIPTION...3 1.1 Reference norms...3 1.2 Symbols description...3 2 DATA LABEL...4 3 CAUTION...5 3.1 General Warnings...5 3.2 Warnings on Handling...5 3.3 Warnings on positioning and installation...6 3.4 Warnings on non-scheduled maintenance...6 4 DESCRIPTION OF THE UNIT...7 5 TECHNICAL DATA...8 5.1 Table...8 6 HANDLING AND TRANSPORT...9 7 INSTALLATION...10 7.1 Installation of ACU...10 7.2 Installation of accessories...14 8 USE...15 8.1 Use intended by the Manufacturer...15 8.2 Contraindications...15 9 FIRST START...16 10 SCHEDULED MAINTENANCE...17 10.1 What you must verify during scheduled maintenance...17 11 TROUBLESHOOTING...19 12 SAFETY AND PROTECTION DEVICES...20 12.1 Description...20 12.2 Check-up...20 13 DISPOSAL OF THE ACU...20 13.1 Uninstallation...20 13.2 Materials in the ACU...20 13.3 Special materials:...21 14 ATTACHMENTS...21 Page 2 of 21

Before proceeding with installation of the Air Conditioning Unit (from now on ACU or Unit), it s necessary to read this manual carefully. This manual is bundled with the ACU, and must be stored with care. 1 REFERENCE NORMS AND SYMBOLS DESCRIPTION 1.1 Reference norms MECHANICAL CONSTRUCTION ELECTRICAL CONSTRUCTION PIPING CONSTRUCTION UNI - ISO Norms IEC - CEI - EN - Norms ISPESL ISO - Norms The ACU complies: With norms 89/392 CEE, 91/368 CEE, 89/336 CEE, 73/23 CEE, and subsequent modifications. With norms CEI- EN 60204-1 (Safety of Machinery - Electrical Equipment of Machinery). With norm ISO R 1662 (Refrigerant Plants - Safety Requirements). For the above ACU exists a technical documentation and working procedures If other devices are bundled with the ACU, they will be supplied with their own instruction manuals. 1.2 Symbols description The symbols below are mentioned on this manual or on the Unit itself. Warning To be performed by a trained technician Operation not allowed Print or Copy this Useful suggestions See also page or chapter Operation to be performed by two persons Environmental care See Use, scheduled maintenance and installation manual Contact the Manufacturer Page 3 of 21

2 DATA LABEL Locate the label on the ACU to know technical data. If something is nonconforming, please contact the retailer or the Manufacturer of the ACU. Data on the label are necessary to correctly connect the machine, to start and to service it. On the label there are data concerning the ACU (model, serial number, weight, etc.) and data concerning the cooling capacity at fixed ambient conditions - (see. norm UNI EN 814). The data label is shown below. The label is on the internal frame of the ACU. Manufacturer identification data Refrigerant type Model......... ABB SACE S.p.A. An ABB Group Company Automation and Distribution Boards 23846 Garbagnate Monastero (LC) Serial Number......... Refrigerant quantity Operating conditions Current FLA Current LRA Supply Voltage......... Frequency......... Refrigerant......... Quantity......... A35/A35 A50/A35 Cool. Cap.......... Cool. Cap.......... El. PWR......... El. PWR......... FLA......... LRA......... Net Weight......... Indoor Protection......... Manuf. Year......... Made in Italy in compliance with norms Input Power Cooling capacity Data label sample Page 4 of 21

3 CAUTION 3.1 General Warnings This manual is addressed to: Shipping clerks Installers Users Maintenance operators The knowledge and the application of safety norms are the base to correctly perform the installation with no risks at all, and to maintain the Unit in it s best efficiency. The installer must read carefully the content of chapter INSTALLATION. The maintainer must read carefully the content of the chapter SCHEDULED MAINTENANCE. Never make any operation if you are not sure of the consequences it could produce. In doubt, please contact the Customers Care in your are, or directly the Manufacturer of the Unit. The Manufacturer of the Unit declines every responsibility for any damage caused by an improper use of the machines. Especially in the following cases: misuse; non-trained personnel use; incorrect installation; faulty material; unauthorized service or modifications; use of non-original spare parts; carelessness of general prescription and specifically of those in the present manual; exceptional events. This manual explains the use of the Unit intended by the Manufacturer. This manual must be stored carefully and must be available for reference. If necessary, make copies of it, to be used on the field. This manual must be kept with the Unit, until it is dismissed. The Manufacturer reserves the right to modify manual contents without any prior notice. 3.2 Warnings on Handling The transport must be performed by qualified personnel only This manual points out the best and more appropriate way for the transport and the handling of the Unit. Always use suitable means of transport. Page 5 of 21

3.3 Warnings on positioning and installation Positioning and installation must be performed by trained personnel only. The installer must verify that every part of the Unit is in good working conditions, prior to install it. In case of doubt, please contact the Manufacturer. The use of Personal Protection Devices may be necessary, depending on working conditions. 3.4 Warnings on non-scheduled maintenance Every operation of non-scheduled maintenance must be performed by trained and qualified technicians. Page 6 of 21

4 DESCRIPTION OF THE UNIT VZ series ACU are packaged type, designed and manufactured to cool electrical enclosures and similar items. They are manufactured to be positioned on the external walls of the enclosure; their shape makes them suitable for many applications. The Unit operation is based on the principle of the reversed Rankine cycle, so heat is transferred by a fluid (refrigerant) that acquires it in the evaporator coil and releases it from the condenser coil; this happens in a sealed circuit. The fluid is driven by an electrically actuated compressor. The evaporator coil is directly facing the electrical enclosure internal, while the condenser is facing the external room. All models are designed with forced-air-circulation evaporator and condenser, with radial fans, to improve performances and to uniform the temperature s distribution in the enclosure internal. All models are basically equipped with temperature controller; they can also be equipped with several optional accessories. VZ series Units are manufactured with galvanized steel plates; they have self-sustaining structure, and RAL 7032 standard color. All Units are manufactured to grant maximum safety and reliability. All the Units are designed, manufactured and verified in compliance with ISO 9001 Norms, which ensures high quality standards. Every Unit is tested extensively, to verify its compliance with design specifications. 5 ENCLOSURE SIDE 6 4 1 COMPRESSOR 2 CONDENSER SECTION FAN 3 CONDENSING COIL 4 EXPANSION VALVE 5 TREATMENT SECTION FAN 6 EVAPORATING COIL 3 2 1 EXTERNAL SIDE Basic cooling circuit diagram Page 7 of 21

5 TECHNICAL DATA 5.1 Table Characteristics Supply voltage (standard) Measuring units Models VZ1550 VZ1850 VZ1400 VZ2000 V 230 230 230 230 Frequency Hz 50 60 50 60 50 60 50 60 Cooling capacity W 605 670 810 900 1300 1480 1926 2200 Input power W 330 360 400 450 650 720 800 920 Current LRA A 8 12,5 21 22 FLA A 2 4 4,5 Fuse protection A 4,9 5,9 8 Air flow rate (evaporator side). mc/h 380 350 350 500 Air flow rate (condenser side) mc/h 400 400 600 950 Electrical protection degree (enclosure side) IP 54 54 54 54 Refrigerant gas (standard) Type R134a R134a R134a R134a Refrigerant quantity (weight) g 490 490 550 550 Maximum external working temperature C 55 55 55 55 Noise level db(a) 64 64 66 66 380 x 198 x 380 x 198 x 380 x 198 x Overall dimensions (WxDxH) (mm) 1025 1025 1025 Weight Kg 33 33 36 42 Color RAL 7032 7032 7032 7032 Reference to drilling template A A A B 380 x 230 x 1100 (1) Cooling capacity is referred at the following working conditions: External temperature 35 C Internal temperat ure 35 C - R. H. = 50%. Page 8 of 21

6 HANDLING AND TRANSPORT The Unit must be transported by qualified personnel only. The weight of VZ series Units is listed in chapter TECHNICAL DATA. During handling keep the Unit upright, even if it is possible to incline it until 45. If during transport the Unit was stored horizontally. It s necessary to wait at least 6 hours before switching it on. Lift the Unit only taking it for the body. During transport, the Units will be packaged alone or in couple, over a wooden pallet. In case it is necessary to move the electrical enclosure after the installation of the Unit, it s necessary to separate it from the enclosure, package it again and transport it packaged alone. During transport hold the Unit absolutely upright, avoiding horizontal position. While unpacking the Unit, be careful at spare parts bundled with it. Page 9 of 21

7 INSTALLATION 7.1 Installation of ACU The ACU must be installed on the wall of the electrical enclosure, over a smooth surface, to avoid vibrations. Leave a suitable distance between the ACU and its neighborhood, to easily service it, if necessary, and to allow air circulation. Verify that the part where the ACU will be mounted is capable of supporting the weight of the ACU, especially if it is going to be mounted on the door of the enclosure. Make the openings for air inlet, air outlet, cables and mounting screws as follows. 380 380 1025 1100 A 198 230 Overall dimension When the ACU must be installed on the door of the electrical enclosure, be sure that the hinges of that door are strong enough, and verify that, when opening the door, the enclosure is stable and does not tip over. Page 10 of 21

Make the openings as shown in the following schemes. If the drilling template, 1:1 scale,(optional accessory) is bundled with the ACU, place it on the external wall of the enclosure and cut out the openings and make the holes as shown on the template. The drawing reference number of the drilling template is DIMA0003078 (for model VZ2000) and DIMA0003181 (for models VZ1550 VZ1850 VZ1400). 370 370 1015 760 70 269.5 160 25.5 60 105 160 25 Ø9 WARM AIR SUCTION FRESH AIR INLET 250 25 Ø9 50 915 1100 840 70 269.5 160 35.5 Ø9 60 105 160 25 Ø9 WARM AIR SUCTION FRESH AIR INLET 250 25 Ø9 Ø9 1000 50 Ø9 125 Ø20 Ø9 125 Ø20 Ø9 Ø9 320 Type A 320 Type B Drilling template Page 11 of 21

Place the adhesive gasket (provided) along the unit s border and in middle position between air inlet and return air openings, as shown in picture below. GASKET How to place adhesive gasket Thread the power supply cables in the appropriate hole, then fix the ACU on the wall with M6 screws (not provided) of suitable length. Operation to be performed by two persons. Verify the correct and free movement of the fan facing the nozzle. Page 12 of 21

CONDENSER COIL AIR OUTLET WARM AIR SUCTION FRESH AIR INLET CONDENSER COIL AIR OUTLET CONDENSER COIL AIR INLET VIEW FROM ENCLOSURE INTERNAL EXTERNAL VIEW Working scheme Be sure that air can circulate freely to refresh the condenser coil; avoid damaging the electrical devices in the enclosure with metal chips produced when making openings and holes in the walls. Page 13 of 21

7.2 Installation of accessories Installation of optional accessories can be performed only by qualified technicians. The electrical board is located immediately beyond the command switchboard. To reach it, remove the external metal shell, as shown in chapter FIRST START. To connect the door micro-switch, remove the jumper 6-9 in the terminal block J4, and connect the micro-switch as shown below. To connect the auxiliary isolating switch of the ACU, remove the jumpers L-3 and N-4 on the terminal block J1 and connect the isolating switch as shown below. Scheme of the electrical board of the ACU. Drawing reference number of the label is ETIC0003079. Page 14 of 21

8 USE 8.1 Use intended by the Manufacturer The Unit is designed to cool electrical enclosures and similar items, and it is supplied to be mounted on them with mechanical fixing devices (not provided); it can be positioned indoor and also outdoor, but anyway sheltered from rain. See chapter TECHNICAL DATA to use the Unit correctly. 8.2 Contraindications The Unit is not intended to work in areas classified AD.PE EEx d (Risk of explosions). It has no improved protections to sustain adverse atmospheric conditions. It is not intended for other uses than what above. To be authorized to use the Unit in other ways than what written above, you must contact the Manufacturer or the dealer in your area. Page 15 of 21

9 FIRST START After you have installed the ACU, and you have connected it to the power supply line, press the ON/OFF switch on the front panel to start it up; the yellow LED will show the Unit is working. Verify that no strange noises (vibrations of metal plates, friction between the fan and the nozzle ) are produced by the Unit when working. ON/OFF Switch To set the value of working temperature, proceed as follows: Remove the screw indicated by arrow 1 Pull gently the lower part of the metal cover as shows arrow 2, enlarging slightly the sides of the metal cover Lift the metal cover in direction of arrow 3. While removing the metal cover, be careful not to damage the ON/OFF switch. 2 3 2 1 How to remove the metal cover If the Unit is equipped with an electro-mechanical temperature controller, located immediately beyond the command panel, rotate its knob to set the temperature. When the Unit is equipped with an electronic controller, see the manual of the device (bundled with the Unit). Page 16 of 21

10 SCHEDULED MAINTENANCE Before every maintenance operation, switch off the main power supply of the Unit. Before switching off the power supply of the Unit and removing the metal cover, pay attention to the noise produced by fans; in case of strange noises, please contact the customer care in your area. 10.1 What you must verify during scheduled maintenance Fans Air Filter (when present) Condenser coil Condensate draining basin Verify that fans rotate freely and without any strange noise. In case, call the Customer s Care in your area. Verify the condition of the filter. If clogged, try cleaning it with a vacuum cleaner or an air-blower gun or water; if it s not possible to clean it, replace it. Periodically, clean the condenser coil using an air-blower gun. Verify that the condensate draining works correctly and that no dirt is in the basin. Verify that the spiral pipe with hot refrigerant is located in the basin. To clean the air filter, it s necessary to remove the metal cover; proceed as described below: Remove the screw indicated by arrow 1 Pull gently the lower part of the metal cover as shows arrow 2, enlarging slightly the sides of the metal cover Lift the metal cover in direction of arrow 3. 2 3 2 1 How to remove the metal cover Remove the filter sliding it sideways in direction A; clean it using an air-blower gun or water; replace it if clogged. Clean the condenser coil (see arrow B) with an air-blower gun, blowing downwards, after you removed the filter (if present). During maintenance, be careful not to damage the fins of the condenser coil. Page 17 of 21

B A A Slide the filter B Condenser coil Missing check-up may be a cause of malfunctions; periodical check-up, as explained in the table above, are required. If necessary, do not hesitate to call the Customer s Care to have an efficient technical assistance to perform the check-up above. Page 18 of 21

11 TROUBLESHOOTING TROUBLE CAUSE RIMEDY ACU does not start up The ACU does not cool; the fan does not work. The ACU does not cool; the internal fan does not work. The ACU does not cool enough The ACU works intermittently. Condensate in the enclosure internal. Water leaks from the ACU Missing power supply. The fuses are gone. Missing power supply. The ACU is off The temperature controller set point is higher than room temperature. The temperature controller does not work High-pressure side pressure-switch has worked Room temperature is higher than maximum working temperature. Too small refrigerant charge The condenser coil is clogged Internal fan does not work External fan does not work. Too small air flow rate in the enclosure internal. Wrong temperature controller set point. Too low temperature of treated air Verify the electrical connections to the supply line Verify the position of the switch (if present). Call the Technical Assistance. Verify the electrical connections to the supply line Push the ON/OFF switch to start the ACU up. Verify the temperature controller set-point Call the Technical Assistance. Verify if the condenser coil is clean and if the external fan works. Call the Technical Assistance. Verify room temperature and the power to sink. Call the Technical Assistance. Verify if the condenser coil is clean Call the Technical Assistance. Verify the air ducts of the openings of the enclosure; make sure the air can pass freely through the openings. Verify the temperature controller set point. Call the Technical Assistance. Set the temperature controller at a higher temperature The electrical enclosure is not sealed Seal the enclosure in some way. Clean the condensate draining Condensate draining basin is dirty. basin Clogged draining pipe. Clean the condensate draining pipe The ACU produces too much Condensate draining basin is full. condensate; probably the enclosure is not sealed. Page 19 of 21

12 SAFETY AND PROTECTION DEVICES 12.1 Description Name High pressure-switch. Safety thermostat Description It stops the Unit when pressure in the discharge line is higher than a fixed value; it resets when pressure goes down again to an allowed value. For multiple actions, verify if the condenser coil and the filter are clean, the fan is working and the room temperature is in the allowed range. In case of frequent actions of this pressure switch, then control if the condenser fan works properly, the filter and condenser coil are clean and the room temperature is higher than the allowed value. When the unit is equipped with diagnostic module, it indicates High temperature condition in the enclosure. The LED Max Temperature will light on. When the Unit is in Heating Mode, the thermostat will also disconnect the electrical heater. In case of frequent actions of this thermostat when the Unit is in Cooling Mode, then control if the evaporator fan works properly and the thermal load is higher than cooling capacity. 12.2 Check-up The refrigerant circuit is sealed so, if no accident occurs, no refrigerant leaks are possible; every two years the ACU must be checked up by a qualified technician, to verify the heat exchangers, the fans, the auxiliary circuits and mechanics and safety devices. 13 DISPOSAL OF THE ACU 13.1 Uninstallation Every operation concerning the uninstallation of the ACU must be performed by qualified and authorized technicians. All the operations concerning the uninstallation are listed in the service manual, in chapter concerning installation. 13.2 Materials in the ACU The ACU is formed of materials that can be treated as secondary raw material (recyclable); the materials are listed below: Structure: Heat exchangers Electrical parts Compressor Painting Iron and steel plates. Aluminium and copper. Copper, PVC e Various materials. Iron, copper and Various materials. Epoxy material. Page 20 of 21

13.3 Special materials: The dismissing of the ACU must be performed by authorized Companies. The disposal of lubricant oil in the compressor must be performed authorized Companies The refrigerant must be evacuated by special devices, then stored in vessels and sent to qualified Companies for disposal. Electrical components and the dehydrator filter must be considered special materials, and they must be sent to an authorized Company for disposal. 14 ATTACHMENTS User Manual of electronic temperature controller (if present) Page 21 of 21