INSTRUCTION FOR COMPLETING COMPETITIVE SOLICITATION ACKNOWLEDGEMENT FORMS



Similar documents
Agilent E3830 Series Wide-bandwidth Signal Analyzer Custom Systems 100 MHz Bandwidth Microwave Vector Signal Analysis

MATRIX TECHNICAL NOTES

RF Network Analyzer Basics

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

W-band vector network analyzer based on an audio lock-in amplifier * Abstract

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Propagation Channel Emulator ECP_V3

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

Impedance 50 (75 connectors via adapters)

0HDVXULQJWKHHOHFWULFDOSHUIRUPDQFH FKDUDFWHULVWLFVRI5),)DQGPLFURZDYHVLJQDO SURFHVVLQJFRPSRQHQWV

RF Measurements Using a Modular Digitizer

R&S FSW signal and spectrum analyzer: best in class now up to 50 GHz

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

Modification Details.

A Low Frequency Adapter for your Vector Network Analyzer (VNA)

RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment

RF Communication System. EE 172 Systems Group Presentation

NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407, University of Wisconsin Madison, Wisconsin 53706

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

Design of Bidirectional Coupling Circuit for Broadband Power-Line Communications

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Engineering Sciences 151. Electromagnetic Communication Laboratory Assignment 3 Fall Term

RFSPACE CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO

How To Use A High Definition Oscilloscope

AFG-100/200 series USB Modular Arbitrary Function Generator. Date: Oct, 2014

Extended Resolution TOA Measurement in an IFM Receiver

Fast and Accurate Test of Mobile Phone Boards

HP 8970B Option 020. Service Manual Supplement

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Application Note Receiving HF Signals with a USRP Device Ettus Research

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

LM1596 LM1496 Balanced Modulator-Demodulator

Optimizing IP3 and ACPR Measurements

Understanding Mixers Terms Defined, and Measuring Performance

Spectrum Analyzers vs. Monitoring Receivers. Paul Denisowski, Application Engineer Rohde & Schwarz

Agilent U2000 Series USB Power Sensors

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Agilent PN Extending Vector Signal Analysis to 26.5 GHz with 20 MHz Information Bandwidth

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

Innovative test solutions WORKSHOP APPLICAZIONI FPGA - INAF 1

Optimizing VCO PLL Evaluations & PLL Synthesizer Designs

SR2000 FREQUENCY MONITOR

Power Amplifier Gain Compression Measurements

A Guide to Calibrating Your Spectrum Analyzer

Agilent 8720 Family Microwave Vector Network Analyzers

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

Improving Network Analyzer Measurements of Frequency-translating Devices Application Note

A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION

Agilent 8904A Multifunction Synthesizer dc to 600 khz

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

LM381 LM381A Low Noise Dual Preamplifier

NI 6601/6602. Contents CALIBRATION PROCEDURE. ni.com/manuals

Active Vibration Isolation of an Unbalanced Machine Spindle

Achieving New Levels of Channel Density in Downstream Cable Transmitter Systems: RF DACs Deliver Smaller Size and Lower Power Consumption


T(CR)3IC Testbed for Coherent Radio Cherenkov Radiation from Cosmic-Ray Induced Cascades

LM118/LM218/LM318 Operational Amplifiers

TCB Workshop. Unlicensed National Information Infrastructure Devices (U-NII)/Dynamic Frequency Selection (DFS)

ELEMENTS OF CABLE TELEVISION

Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note

Spectrum analyzer with USRP, GNU Radio and MATLAB

How To Measure Two Tone, Third Order Intermodulation Distortion

1. The Slotted Line. ECE 584 Microwave Engineering Laboratory Experiments. Introduction:

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Application Note Noise Frequently Asked Questions

Automatic compression measurement using network analyzers

Application Note. Introduction to. Page 1 / 10

Performing Amplifier Measurements with the Vector Network Analyzer ZVB

Current Probes. User Manual

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

W a d i a D i g i t a l

LLRF. Digital RF Stabilization System

Generic - Hearing Loop - (AFILS) U.S. System Specification

VME IF PHASE MODULATOR UNIT. mod

Voltage. Oscillator. Voltage. Oscillator

Tx/Rx A high-performance FM receiver for audio and digital applicatons

TI GPS PPS Timing Application Note

Sweep-able sub-millimeter sources and detectors for THz Vector Network Analyzers and Applications

Michael Hiebel. Fundamentals of Vector Network Analysis

Implementation of Digital Signal Processing: Some Background on GFSK Modulation

AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

CLOCK AND SYNCHRONIZATION IN SYSTEM 6000

Quantum Computing for Beginners: Building Qubits

Network analyzer and spectrum analyzer two in one

DEVELOPMENT OF DEVICES AND METHODS FOR PHASE AND AC LINEARITY MEASUREMENTS IN DIGITIZERS

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

DEVELOPMENT OF THE SWISSFEL UNDULATOR BPM SYSTEM

Ralph L. Brooker, Member, IEEE. Andrew Corporation, Alexandria, VA 22314, USA

FRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS. drm TesT equipment

AMICSA Integrated SAR Receiver/Converter for L, C and X bands Markku Åberg VTT Technical Research Centre of Finland

Spectrum Compact: Revolutionary 6-40GHz Spectrum Analyzer

Measurement of Adjacent Channel Leakage Power on 3GPP W-CDMA Signals with the FSP

Testing of 10 GHz Instantaneous Bandwidth RF Spectrum Monitoring at Idaho National Labs

Network Analyzer Operation

Considerations When Specifying a DC Power Supply

CONDUCTED EMISSION MEASUREMENT OF A CELL PHONE PROCESSOR MODULE

Transcription:

INSTRUCTION FOR COMPLETING COMPETITIVE SOLICITATION ACKNOWLEDGEMENT FORMS The Competitive Solicitation Acknowledgement Form must be completely filled in. This may be done on line then printed or you may print then fill in with pen or typewriter. PLEASE NOTE: IF THIS IS NOT COMPLETED IT MAY BE GROUNDS FOR REJECTING YOUR SOLICITATION. NOTICE TO RESPONDERS: Responders must E-Mail or Fax Verification of Receipt of Competitive Solicitation. E- Mail Mary Ward at fsusolicitation@admin.fsu.edu or Fax Attention: Mary Ward, (850) 644-8921.

FLORIDA STATE UNIVERSITY REQUEST FOR INFORMATION QUASI-OPTIC SPECTROMETER AT 94 GHz (HIPER) RFI-5434-3 The National High Magnetic Field Laboratory (NHMFL) at Florida State University has requested that an Electron Paramagnetic Resonance (EPR) spectrometer system be purchased. The Purchasing Department is considering a non-competitive procurement of the EPR spectrometer system on the grounds that only one supplier can meet the requirements stipulated by the National High Magnetic Field Laboratory for their research. As a part of the sole source investigation, this letter seeks information from vendors who sell EPR spectrometer systems and could possibly provide competitive product/services. BACKGROUND/FEATURES The vendor under consideration by the NHMFL is University of St. Andrews. The high time resolution of this instrument, coupled with the high frequency, (less than 5 ns deadtime instead of a typical 100 ns for commercial instruments) allows the investigation of radicals and spin system with very fast spin dynamics, and thus open the way for the investigation of spin dynamics in a time regime that had until now been inaccessible. System will be a copy of the present HIPER EPR system (as described in Review of Scientific Instruments, Vol.80, pp.103102-15, Oct 2009) operating at low power at 94 GHz, incorporating recent and ongoing hardware and software improvements, where the system will be designed to allow operation at high power (kw) in the future. EQUIPMENT (Design and Hardware Specifications) The system will include a number of electronic modules and test equipment controlled by software written in Labview CVI that will allow flexibility in setting up experiments, specifying complex pulse sequences and recording. The system must meet the following: Quasi-Optics and supporting structure to be manufactured by Thomas Keating as a copy of the current HIPER system functioning as a very high-performance induction mode EPR spectrometer with extremely low deadtime. This will include: Supporting Rexroth structure Base Plates to hold components Frequency independent focussing mirrors in a configuration to significantly reduce coma aberrations at 94GHz 3 quasi-optical isolators and associated polarisers and loads to provide low loss isolation and very low return loss between source and sample 2 quasi-optical isolators and associated polarisers and loads to provide low loss isolation and very low return loss between sample and detector Corrugated pipe adapted for specified flow cryostat (Stainless steel) Integrated vacuum window designed to have very low return loss Integrated Swing Arm to allow probe and samples to be removed efficiently Source and Detector high purity Gaussian feedhorns (Copper and Stainless Steel) Stainless steel feedhorn with copper extension (to sample-holder) to be attached to corrugated pipe

Stainless steel corrugated pipe extension for ultra-low deadtime Various non-resonant sample-holders incorporating fast sample holder The design will permit operation in non-induction mode Electronic modules the electronics will consist of a number of separate modules held in two 19 inch rack units. 1. 10 MHz module this module supplies a number of 10MHz outputs ((2 square wave outputs and 9 sine outputs) derived from a very low noise ovenised 10MHz control reference used as the overall system clock to provide very long term stability. 2. Main Source Module provides a number of software selectable low phase noise source options (locked to EIP counters for long term stability) nominally @ 7.6833 GHz 3. Interpolation Module - provides a separate coherent source derived from the main source via a low noise 150 MHz upconversion, to nominally provide a signal @7.833GHz and a tracking filter. This combination allows stable coherent detection. 4. ELDOR module provides software selectable built in low noise source (or separate external source) that can be switched into the source path (intentionally incoherent with the main source or local oscillator). 5. Phase module allows fast phase switching and selection of different phases (current design is 4 but about to be upgraded to 16) for both main source and ELDOR channels 6. Fast switch Module allows low power pulse formation with very fast rise- and fall-times (determined by instantaneous bandwidth of multiplier) controlled by output from Parbert for both main source and ELDOR channels. On the existing system at low power the rise-times and fall-times are <100ps. 7. Multiplier/WG module multiplies to produce 100 mw @ ~ 94GHz +- several GHz. Also incorporates a software controllable 60 db (50 db linear) WG attenuator and forward and reverse power monitors (with associated couplers) 8. Receiver module incorporating a 94 GHz multiplier, mixer, low noise IF amplifiers, fast receiver protection and a suitable delay line for the local oscillator 9. IQ demodulator incorporating at least 2 selectable low noise 1800 MHz sources one derived from the 150MHz source via a suitable delay line. This also includes 3 software selectable filters - wideband (1 GHz), PELDOR (40 MHz), cw (few MHz) and software selectable gain 10. Power supply Module to supply all the low noise dc power requirements for the system (replacing the multiple power supplies currently in use) 11. Interlock Box to prevent operation unless the probe is in place (mainly for high power operation) 12. Bus Module providing the main hardware/software interface to the Electronics

Other Electronic Equipment: - in addition a number of electronic equipment modules and components to be incorporated Industrial PC and flat screen Multiple flat screens for monitoring around spectrometer National Instruments IEE Cards High performance microwave cabling Highland Technologies (2 DDG cards) Audio Amplifier to power the modulation coil for cw operation (not software interfaced) Stanford Low frequency SR760 FFT spectrum analyser Stanford SR830 Lock-in amplifier LeCroy Fast sampling Scope 3 EIP counters Agilent PARBERT system in VXI crate Aqiris fast sampling card Software - software will be supplied to run the instrument that will be similar in essential detail to the software designed and used in the present HIPER system. The software runs under LabWindows CVI and controls virtually all aspects of the instrument and allows almost arbitrary pulse sequences to be setup in a easy to use front-end interface. It also allows data to be efficiently recorded either via the Aqiris card or LeCroy scope along with virtually all associated experimental parameters for many common pulse experiments. The instrument can be monitored via the web. If your company can offer a high Electron Paramagnetic Resonance spectrometer system as a purchased system and can meet or exceed the requirements listed herein, please submit a written response to the Purchasing Department no later than 5:00PM, August 27, 2010. Note: This is not a request for pricing, only information gathering. The University shall be the sole judge of the results of this investigation. If the decision is made to waive bidding and proceed with Electron Paramagnetic Resonance (EPR) spectrometer system by purchased system procurement on a sole source basis, appropriate public notice shall be posted in the Purchasing Department. Inquiries should be addressed to the Purchasing Department, not to personnel at the National High Magnetic Field Laboratory. If you have any questions, please do not hesitate to contact me by telephone at 850-644-6850, by fax at 850-644-8921, or by e-mail at nlybbert@admin.fsu.edu. Your assistance in this matter is appreciated. Sincerely, Nicholas Lybbert Purchasing Specialist