Facility Smart Grid Information Model



Similar documents
Public Review Draft. ASHRAE Standard

MATCHDAY September 2014

CIM-based Utility Data Model Solution for Enterprise Analytics

Academic Calendar for Faculty

International University of Monaco 27/04/ :55 - Page 1. Monday 30/04 Tuesday 01/05 Wednesday 02/05 Thursday 03/05 Friday 04/05 Saturday 05/05

International University of Monaco 21/05/ :01 - Page 1. Monday 30/04 Tuesday 01/05 Wednesday 02/05 Thursday 03/05 Friday 04/05 Saturday 05/05

Trading Calendar - East Capital UCITS Funds

International University of Monaco 11/06/ :27 - Page 1. Monday 30/04 Tuesday 01/05 Wednesday 02/05 Thursday 03/05 Friday 04/05 Saturday 05/05

CRM Form to Web. Internet Lead Capture. Web Form Configuration Instructions VERSION 1.0 DATE PREPARED: 1/1/2013

EVault for Data Protection Manager. Course 411 Understanding EVault Retentions

International University of Monaco 12/04/ :50 - Page 1. Monday 30/01 Tuesday 31/01 Wednesday 01/02 Thursday 02/02 Friday 03/02 Saturday 04/02

Oracle Utilities Integration for Device Operations

Parent s Consent Form for a School-Aged or Young Child

Using Energy and Meter Reading

Customer Case Study Patch, Monitor, and Manage Servers

FINAL SCHEDULE YEAR 1 AUGUST WEEK 1

TIBCO Spotfire Metrics Modeler User s Guide. Software Release 6.0 November 2013

SYSML PLUGIN. version user guide

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

Analytics Configuration Reference

Foglight. Dashboard Support Guide

Commission Pay Plans & Minimum Compensation Entitlement

CA Nimsoft Monitor. Probe Guide for NT Event Log Monitor. ntevl v3.8 series

Academic Calendar

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Assets, Groups & Networks

Chapter 7 Data Modeling Using the Entity- Relationship (ER) Model

Mobile Time Manager. Release 1.2.1

Event Kit Programming Guide

Realization of control center HMIs by using IEC and CIM data bases for communication and data handling

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

CA Nimsoft Monitor. Probe Guide for Active Directory Server. ad_server v1.4 series

ETSI TR V1.1.2 ( )

CA Nimsoft Monitor. Probe Guide for Lotus Notes Server Monitoring. notes_server v1.5 series

Public Review Draft. ASHRAE Standard

--****************************************************************************** -- Filename: FDOT -standard Global MIB v01.mib -- Source: NTCIP

11 November

Spambrella SaaS Encryption Enablement for Customers, Domains and Users Quick Start Guide

INTRODUCTION... 4 MODULE 5. TIMESHEET Overview TIMESHEET CALENDAR VIEW... 7 INTRODUCTION What you will learn in this section...

Data Mailbox. support.ewon.biz. Reference Guide

Vision 360 Appointments

Part-time Diploma in InfoComm and Digital Media (Information Systems) Certificate in Information Systems Course Schedule & Timetable

S&C IntelliTeam CNMS Communication Network Management System Table of Contents Overview Topology

User Manual for Web. Help Desk Authority 9.0

Gateway Reporting Developer Guide

CA Nimsoft Monitor. Probe Guide for iseries System Statistics Monitoring. sysstat v1.1 series

ICT Helpdesk. User Guide. 24 th May Page 1

CA Nimsoft Monitor. Probe Guide for CA ServiceDesk Gateway. casdgtw v2.4 series

CA Nimsoft Monitor. Probe Guide for Active Directory Response. ad_response v1.6 series

MODEL SCHEDULING SPECIFICATION

ORACLE OPS CENTER: VIRTUALIZATION MANAGEMENT PACK

Service Level Agreement Guide. Operations Center 5.0

IRA 423/08. Designing the SRT control software: Notes to the UML schemes. Andrea Orlati 1 Simona Righini 2

FORT LAUDERDALE INTERNATIONAL BOAT SHOW BAHIA MAR IN-WATER SET-UP SCHEDULE

Contents Firewall Monitor Overview Getting Started Setting Up Firewall Monitor Attack Alerts Viewing Firewall Monitor Attack Alerts

CA Nimsoft Monitor Snap

Automotive Consulting Solution. Lean Manufacturing Planning & Control (LMPC)

Oracle Enterprise Manager. 1 Introduction to SAP Monitoring with Oracle Enterprise Manager Grid Control. 1.1 Overview

User Guide. The Business Energy Dashboard

Customer Portal User Guide

Microsoft Dynamics GP. Field Service - Contract Administration

Multiple choice: The format for any kind of multiple choice question is 1) the question, 2) a blank line, and 3) the answers on separate lines:

Microsoft Office Outlook 2013

Job Status Guide 3.0

GUIDANCE. Using the template interface agreement for rail or road crossings

How To Settle A Half Hourly Meter Charge

Microsoft Dynamics GP. Electronic Signatures

Microsoft Dynamics GP. Manufacturing Planning Functions

Business On Line Payments Plus Customer Support Guide

GNU Free Documentation License

Microsoft Dynamics GP. Field Service - Preventive Maintenance

Energy Monitoring MIB

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

A Meeting Room Scheduling Problem

Avaya 2033 IP Conference Phone User Guide. Avaya Business Communications Manager

Microsoft Dynamics GP. Working with Crystal Reports

HIGHSEC eid App Administration User Manual

SaaS Encryption Enablement for Customers, Domains and Users Quick Start Guide

Magento Dhru Fusion Integration Extension. IMEI Profile Configuration

Technical Help Desk Terms of Service

Hotel Management System Standard Version Guide

NetBak Replicator 4.0 User Manual Version 1.0

Aras Corporation Aras Corporation. All rights reserved. Notice of Rights. Notice of Liability

COMPLETE MANUAL. Version: Optic. September 2015 (English), version 1.0. EnergyOT Optic Developed and Manufactured by Genoa Spark, lda Made in Portugal

Service Availability TM Forum Application Interface Specification

User Guide. The Business Energy Dashboard

How To Use A Microsoft Microsoft Database Server 2012

Academic Calendar - UNDERGRADUATE. All Other Classes Begin; Late Registration Begins. Last Day to Drop a Class without a W on Transcript;

technical brief Multiple Print Queues

Blue Cross and Blue Shield of Texas (BCBSTX)

Transcription:

BSR/ASHRAE/NEMA Standard 20P Second Public Review Draft Facility Smart Grid Information Model Second Public Review (January 206) (Review of Independent Substantive Changes) This draft has been recommended for public review by the responsible project committee. To submit a comment on this proposed standard, go to the ASHRAE website at www.ashrae.org/standards-research--technology/publicreview-drafts and access the online comment database. The draft is subject to modification until it is approved for publication by the Board of Directors and ANSI. Until this time, the current edition of the standard (as modified by any published addenda on the ASHRAE website) remains in effect. The current edition of any standard may be purchased from the ASHRAE Online Store at www.ashrae.org/bookstore or by calling 404-636-8400 or -800-727- 4723 (for orders in the U.S. or Canada). The appearance of any technical data or editorial material in this public review document does not constitute endorsement, warranty, or guaranty by ASHRAE of any product, service, process, procedure, or design, and ASHARE expressly disclaims such. 205 ASHRAE. This draft is covered under ASHRAE copyright. Permission to reproduce or redistribute all or any part of this document must be obtained from the ASHRAE Manager of Standards, 79 Tullie Circle, NE, Atlanta, GA 30329. Phone: 404-636-8400, Ext. 25. Fax: 404-32-5478. E-mail: standards.section@ashrae.org. ASHRAE, 79 Tullie Circle, NE, Atlanta GA 30329-2305

BSR/ASHRAE Standard 20P, Facility Smart Grid Information Model FOREWORD The second public review draft of proposed BSR/ASHRAE/NEMA Standard 20P contains a number of independent substantive changes to the first public review draft that constitute the scope of the review. The clauses containing these changes are enumerated below. Each change is described and then presented with some surrounding context to aid the reader in understanding where the change occurs. The specific changes are highlighted with strike through (deletions) or underline (additions). In the case of diagrams, the changed portion is highlighted with an oval. [Change 5.2 Device] Background: The association between the Device class and the ComponentElement class was changed to enable bidirectional navigation so that a component element can know what device it is part of. This is illustrated in Figure 5.2 (red circle), but the identical change occurs in Figure 5.3 and Figure 7.9 where both Device and ComponentElement appear in a different context. The change also effects the description of the connections in the ComponentElement class. class Device NAESB PAP0 EUI:: IdentifiedObject + aliasname: String [0..] + mrid: GlobalId [0..] [0..] +IdentifiedObject +Names NAESB PAP0 EUI:: Name +Names +NameType NAESB PAP0 EUI:: NameType +NameTypes +NameTypeAuthority 0.. NAESB PAP0 EUI: : NameTypeAuthority +tags FSGIMIdentifiedObject + aliasname: String [0] + mrid: GlobalId + nametype: String + nametypeauthority: String [0..] Dev ice + devicetype: MasterFormatType [0..] + extendedinfo: ExtendedInfoType [0..] + status: DeviceStatus [0..] +partof +component..* ComponentElement +devicenameplate 0.. CDCDescription::DPL + altitude: Real [0..] + epsname: String [0..] + hwrev: String [0..] + latitude: Real [0..] + location: String [0..] + longitude: Real [0..] + model: String [0..] + mrid: GlobalId [0..] [0..] + owner: String [0..] + primeoper: String [0..] + secondoper: String [0..] + sernum: String [0..] + swrev: String [0..] + vendor: String «enumerati... Dev icestatus Normal Warning Alarm ExtendedInfoType + ExtendedInfoReference: String MasterFormatType + code: String Energy Manager Component::EM Meter Component::Meter Load Component::Load Generator Component::Generator +ems +meters +loads +generators Figure 5.2 - Device

BSR/ASHRAE Standard 20P, Facility Smart Grid Information Model 5.2.3. ComponentElement (Abstract Class) This class is an abstract class representing the top level class of one of the four FSGIM model components or a Collection of these top level classes. Note that the parts of a Collection instance inherit the tag attribute values of its parent collection ComponentElement instance. Parent Class: FSGIMIdentifiedObject ( 5.2.3.4) UML Element Location: Model\Device and Model Components\Device\ComponentElement. This element has the following connections to other elements: Table 5. - Class Connections Connection Type Role Name Description Role Type Multiplicity Composition (with bidirectional navigation) partof The physical device that houses the functionality of the EM Class, Meter Class, Load Class, and/or Generator Class. Device 5.2.3.2 [] Association tags This attribute may contain a set of strings to be used at the configuration phase of installation such as "hallway", "3rd Floor", "Critical,... These strings may be optionally qualified with a NameType and NameTypeAuthority. Name 5.7.5.2..4 [] [Change 5.6.7.4 EMIntervalData (Class)] Background: The description of resources was changed to make it clear that it means only the set of loads, generators, meters and EMs that are directly connected to an EM. This change was made to be consistent with the standard aggregation rules. This change also effects the description of the derived attribute presentresources in the EMPresentData class found in Table 5.36. 5.6.7.4 EMIntervalData (Class) This class represents data in the domain of concern of an Energy Manager over some complete interval of time. This time interval may be in the past or future. Parent Class: AttachType ( 5.7.3.2.4) UML Element Location: Model\Device and Model Components\Energy Manager Component\EMIntervalData. Table 5.32 - Class Attributes Attribute Description Attribute Type Multiplicity Name... resources The set of all of the loads, generators, meters and EMs that are directly or indirectly managed by the energy manager during the interval referenced by the IntervalDataContainer through the attach relation. AllResourcesIn EMDomain 5.6.7..2. [0..] Table 5.36 - Class Attributes Attribute Name Description Attribute Type Multiplicity presentresources (Derived The set of all of the loads, generators, meters and EMs that are directly or indirectly managed by the energy manager at AllResourcesInEMDomain 5.6.7..2 [] 2

BSR/ASHRAE Standard 20P, Facility Smart Grid Information Model Attribute Name Description Attribute Type Multiplicity attribute) this instant in time. [Change 5.7.5.2..26 UsagePoint (Class)] Background: A new attribute, isvirtual, was added to the UsagePoint class. This attribute appeared in a revision of IEC 6968-9 and serves as a flag to indicate a virtual measurement. This same flag was added to Green Button and will be added to the next release of "NAESB Business Practices and Information Models to Support Priority Action Plan 0 - Standardized Energy Usage Information standards. Revision. 202. Because EMUsagePoint is derived from UsagePoint, the change affects Clause 6.4.2 Measurement Sets (Figure 6.4) and the EMUsagePoint Conformance Block (Figure 7.24). 5.7.5.2..26 UsagePoint (Class) Logical point on a network at which consumption or production is either physically measured (e.g. metered) or estimated (e.g. unmetered street lights). Parent Class: IdentifiedObject ( 5.7.5.2..8) UML Element Location: Model\Model Elements from External Sources\iec_cim_naesb_eui_model_200Update_2020802\NAESB PAP0 EUI\UsagePoint. Table 5.307 - Class Attributes Attribute Name Description Attribute Type Multiplicity description A human readable description of the object. String [0..] 6.6.3.7. isvirtual Is used to indicate that the UsagePoint is virtual (that is, not a real physical measurement). This may be the result of a computation or estimation. Boolean 6.6.3.3. [] name The name is any free human readable and possibly non unique text naming the object. String 6.6.3.7. role Flags The set of roles pertinent to this UsagePoint RoleFlags 5.7.5.2..28 status Status of this UsagePoint: 0 - Off - On Integer 6.6.3.5 [0..] [] [] 3

BSR/ASHRAE Standard 20P, Facility Smart Grid Information Model 6.4.2 Measurement Sets Diagram Some concepts in the Facility Smart Grid Information Model, such as aggregation, apply equally to PowerMeasurementSets, EnergyMeasurementSets, and EmissionsMeasurementSets. In these cases, the PowerMeasurementSet, EnergyMeasurementSet, and EmissionsMeasurementSet can be abstracted and referred to as a Measurement Set. class Measurement Sets UsagePoint Energy Manager Component::EMUsagePoint Measurement + timereference: UTCDateTimeInterval [0..] MeasurementSet +measurements ::UsagePoint + description: String [0..] + isvirtual: Boolean [0..] + roleflags: RoleFlags + status: Integer ::IdentifiedObject + aliasname: String [0..] + mrid: GlobalId [0..] [0..] Power Measurements:: PowerMeasurementsSet Energy Measurements:: EnergyMeasurementsSet Emissions Measurements:: EmissionsMeasurementsSet Figure 6.4 - Measurement Sets 4

BSR/ASHRAE Standard 20P, Facility Smart Grid Information Model 7.3.3.2.5 EMUsagePoint Conformance Block Diagram This diagram depicts the classes and attributes used to define the grid view of the logical point on a network where consumption or generation is either measured or estimated. class EMUsagePoint Conformance Block NAESB PAP0 EUI:: UsagePoint + description: String [0..] + isvirtual: Boolean [0..] + roleflags: RoleFlags + status: Integer +UsagePoint NAESB PAP0 EUI:: IdentifiedObject + aliasname: String [0..] + mrid: GlobalId [0..] [0..] +IdentifiedObject NAESB PAP0 EUI:: NameTypeAuthority +NameTypeAuthority 0.. +NameTypes Time:: DateTimeInterval «Compound» Time::UTCDateTimeInterv al + duration: Duration [0..] + end: UTCDateTime [0..] + start: UTCDateTime [0..] +ElectricPowerQualitySummaries NAESB PAP0 EUI:: ElectricPowerQualitySummary + flickerplt: Real [0..] + flickerpst: Real [0..] + harmonicvoltage: Real [0..] + longinterruptions: Integer [0..] + mainsvoltage: Real [0..] + measurementprotocol: String [0..] + powerfrequency: Real [0..] + rapidvoltagechanges: Integer [0..] + shortinterruptions: Integer [0..] + summaryinterval: UTCDateTimeInterval + supplyvoltagedips: Integer [0..] + supplyvoltageimbalance: Integer [0..] + supplyvoltagevariations: Integer [0..] + tempovervoltage: Integer [0..] +Names NAESB PAP0 EUI::NameType +NameType +Names NAESB PAP0 EUI::Name EMGenerationType Conformance Block GenerationType Energy Manager +supplysources Component:: EMGenerationType EMLoadReductionType Conformance Block LoadReductionType Energy Manager +demandsources Component:: EMLoadReductionType..*..* Energy Manager Component: :EMUsagePoint constraints {For the FSGIM, the associations from the parent UsagePoint Class to the other NAESB classes all have a multiplicity of 0 with the exception of ElectricPowerQualitySummary because this information is captured in other ways in the FSGIM model.} +logicalemusagepoint 0.. 0.. +physicalconnectionpoint Other Common Classes:: ConnectionPoint Circuit Conformance Block +connectedto 0.. FSGIMIdentifiedObject Other Common Classes::Circuit High Level Measurements Conformance Block Measurements::Measurement EmixInterfaceType Conformance Block +emixinterfacetype Emix:: EmixInterfaceType 0.. +measurements +localtimeparameters 0.. Time::LocalTimeParameters + dstendrule: DstTransitionRule + dstoffset: Integer + dststartrule: DstTransitionRule + tzid: String [0..] + tzoffset: Integer Time::DstTransitionRule + dayofmonth: Integer + dow: WeekdayType + hours: Integer + month: MonthType + rule: DstRule + seconds: Integer «enumeration» Enumerations:: WeekdayType sunday = 0 monday = tuesday = 2 wednesday = 3 thursday = 4 friday = 5 saturday = 6 «enumeration» Enumerations:: MonthType january = february = 2 martch = 3 april = 4 may = 5 june = 6 july = 7 august = 8 september = 9 october = 0 november = december = 2 Figure 7.24 - EMUsagePoint Conformance Block 5