Ingeniería e Investigación ISSN: 0120-5609 revii_bog@unal.edu.co Universidad Nacional de Colombia Colombia



Similar documents
INGENIERíA. Scada System for a Power Electronics Laboratory. Sistema SCADA para un laboratorio de electrónica de potencia Y D E S A R R O L L O

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Incipient Failure Detection in Power Transformers through Frequency Sweep Response

ANIMA: Non-Conventional Interfaces in Robot Control Through Electroencephalography and Electrooculography: Motor Module

Laboratory 4: Feedback and Compensation

EE 1130 Freshman Eng. Design for Electrical and Computer Eng.

Case Studies in On-Line Measurement of PD in Motors Fed by Voltage Source PWM Drives

GUIDE FOR TESTING POWER TRANSFORMERS

A wave lab inside a coaxial cable

Programming Real-Time Motion Control Robot Prototype

MICRO HYDRO POWER PLANT WITH INDUCTION GENERATOR SUPPLYING SINGLE PHASE LOADS

MOBILE SYSTEM FOR DIAGNOSIS OF HIGH VOLTAGE CABLES (132KV/220KV) VLF-200 HVCD

Application of network analyzer in measuring the performance functions of power supply

Technical Information

Making Accurate Voltage Noise and Current Noise Measurements on Operational Amplifiers Down to 0.1Hz

POWER SYSTEM HARMONICS. A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS

Design of Bidirectional Coupling Circuit for Broadband Power-Line Communications

A true low voltage class-ab current mirror

Introduction. Harmonics and IEEE 519 Page 1 of 19

Lecture 1-6: Noise and Filters

AVX EMI SOLUTIONS Ron Demcko, Fellow of AVX Corporation Chris Mello, Principal Engineer, AVX Corporation Brian Ward, Business Manager, AVX Corporation

IN recent years, with the development of online monitoring

Simulation and Analysis of Parameter Identification Techniques for Induction Motor Drive

Power Quality Standards for Electric Service

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

THIS paper reports some results of a research, which aims to investigate the

Simulation and Design of Printed Circuit Boards Utilizing Novel Embedded Capacitance Material

Práctica 1: PL 1a: Entorno de programación MathWorks: Simulink

Radiated emission measurement of a cell phone processor module using TEM cell

Bipolar Transistor Amplifiers

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

Development of an Electrical Power Quality Monitor Based on a PC

Miniature Surface-Mount DAA for Audio or Data Transfer XE0402LCC BLOCK DIAGRAM

INDUCTION MOTOR PERFORMANCE TESTING WITH AN INVERTER POWER SUPPLY, PART 2

1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING

TEACHING AUTOMATIC CONTROL IN NON-SPECIALIST ENGINEERING SCHOOLS

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

Adaptive fusion of ETM+ Landsat imagery in the Fourier domain

RC NETWORKS SALES GUIDE

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

Current Probes. User Manual

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions

MATRIX TECHNICAL NOTES

Transistor Amplifiers

Troubleshooting accelerometer installations

Relationship between large subject matter areas

Product Data Bulletin

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Module 11: Conducted Emissions

Network Theory Question Bank

Pulsed Power Engineering Diagnostics

A Sound Analysis and Synthesis System for Generating an Instrumental Piri Song

VCO Phase noise. Characterizing Phase Noise

A virtual sensor for monitoring excited thermal turbogenerator rotors

Voltage Regulator SPAU 341 C. Product Guide

Vibration analysis and monitoring Compact. Powerful. Modern technology.

0HDVXULQJWKHHOHFWULFDOSHUIRUPDQFH FKDUDFWHULVWLFVRI5),)DQGPLFURZDYHVLJQDO SURFHVVLQJFRPSRQHQWV

A bidirectional DC-DC converter for renewable energy systems

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System

Dyna ISSN: Universidad Nacional de Colombia Colombia


Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka

Energy Management Energy Meter Type EM23 DIN

Designers Series XII. Switching Power Magazine. Copyright 2005

Survey of Harmonics Measurements in Electrical Distribution Systems

Principles of Adjustable Frequency Drives

HIGH VOLTAGE POWER SUPPLY FOR ELECTRO-OPTICS APPLICATIONS

Advanced Power Measurement and Analysis Software DPOPWR Datasheet

Electronic Communications Committee (ECC) within the European Conference of Postal and Telecommunications Administrations (CEPT)

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

Table of Contents. TransformerIQ FAQs 1

CONDUCTED EMISSION MEASUREMENT OF A CELL PHONE PROCESSOR MODULE

MEASUREMENT SET-UP FOR TRAPS

José A. Cobos, Pedro Alou Centro de Electrónica Industrial (CEI)

VICOR WHITE PAPER. The Sine Amplitude Converter Topology Provides Superior Efficiency and Power Density in Intermediate Bus Architecture Applications

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

CLASS D POWER AMPLIFIERS

Generalised strategy for implementing the minimum fault reactance based fault location algorithm in real power distribution systems

TDA4605 CONTROL CIRCUIT FOR SWITCH MODE POWER SUPPLIES USING MOS TRANSISTORS

Fundamentals of Power Electronics. Robert W. Erickson University of Colorado, Boulder

ANN Based Fault Classifier and Fault Locator for Double Circuit Transmission Line

EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID

BARE PCB INSPECTION BY MEAN OF ECT TECHNIQUE WITH SPIN-VALVE GMR SENSOR

EET272 Worksheet Week 9

Grid Interconnection of Renewable Energy Sources Using Modified One-Cycle Control Technique

AN-837 APPLICATION NOTE

Linear Parameter Measurement (LPM)

On-Line Diagnosis using Orthogonal Multi-Tone Time Domain Reflectometry in a Lossy Cable

Electric utilities may vary in their application of end-to-end testing

LR Phono Preamps. Pete Millett ETF.13.

POWER LINE FILTERS FOR SWITCHING POWER SUPPLIES

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

DIODE CIRCUITS LABORATORY. Fig. 8.1a Fig 8.1b

HP 8970B Option 020. Service Manual Supplement

A comparative study of two models for the seismic analysis of buildings

A NEAR FIELD INJECTION MODEL FOR SUSCEPTIBILITY PREDICTION IN INTEGRATED CIRCUITS

Transcription:

Ingeniería e Investigación ISSN: 0120-5609 revii_bog@unal.edu.co Universidad Nacional de Colombia Colombia Gómez-Luna, Eduardo; ponte, Guillermo; Herrera, Wilder; Pleite Guerra, Jorge Experimentally obtaining on-line FR in transformers by injecting controlled pulses Ingeniería e Investigación, vol. 33, núm. 1, enero-abril, 2013 Universidad Nacional de Colombia Bogotá, Colombia vailable in: http://www.redalyc.org/articulo.oa?id=64328174008 How to cite Complete issue More information about this article Journal's homepage in redalyc.org Scientific Information System Network of Scientific Journals from Latin merica, the Caribbean, Spain and Portugal Non-profit academic project, developed under the open access initiative

INGENIERÍ E INVESTIGCIÓN VOL. 33 No. 1, PRIL 2013 (43-45) Experimentally obtaining on-line FR in transformers by injecting controlled pulses Obtención experimental de FR on-line en transformadores mediante la inyección de pulsos controlados E. Gomez-Luna 1, G. ponte 2, W. Herrera 3 and J. Pleite 4 BSTRCT Transformer monitoring based on the operating condition (on-line test) has boomed in recent years because it allows early detection of risk situations or limitations regarding use to make appropriate decisions before a failure occurs. Frequency response analysis (FR) is one of the most heavily researched techniques for on-line development; it is based on obtaining a transformer s frequency response (admittance, impedance or transfer function) in a given bandwidth. This paper presents an experimental method for obtaining the frequency response with the transformer in service by injecting controlled pulses of the voltage signal using an external electronic circuit. Once the voltage and current signals had been recorded, the wavelet transform was used via multi-resolution analysis (MR) for filtering. This led to results being obtained without noise interference from the electrical system. The transfer function was obtained in terms of impedance, using the fast Fourier transform (FFT). The proposed method represented an alternative in solving some problems arising from the on-line FR technique such as filtering and results repeatability. The tests involved a 5-kV 1150/345 V three-phase transformer and a 3-kV, 7620/240 V single-phase transformer in the Universidad del Valle s High Voltage Laboratory. Keywords: On-line FR, on-load FR, Fourier transform, MR analysis, filtering, transformer, multi-resolution analysis. RESUMEN El monitoreo en transformadores basado en la condición de operación (pruebas en línea) ha tenido un gran auge en los últimos años debido a que facilita detectar oportunamente situaciones de riesgo o limitaciones de utilidad que permita tomar decisiones oportunas, antes de que ocurra una falla. Una de las técnicas en la cual se viene investigando con fuerza para el desarrollo en línea es el análisis de la respuesta en frecuencia (FR), la cual se basa en obtener la respuesta en frecuencia (admitancia, impedancia, o función de transferencia) del transformador en un ancho de banda determinado. El siguiente artículo presenta un método experimental para obtener la respuesta en frecuencia con el transformador en servicio, por medio de la inyección de pulsos controlados sobre la señal de voltaje, usando un circuito electrónico externo. Una vez registradas las señales de voltaje y corriente, se usó la transformada Wavelet mediante el análisis multirresolución (MR) para el filtrado, lo que permitió obtener resultados sin problemas de ruido del sistema eléctrico; luego se obtuvo la función de transferencia en términos de la impedancia usando la transformada rápida de Fourier (FFT). De acuerdo con los resultados obtenidos, el método propuesto es una alternativa para dar solución a algunos problemas que se han presentado en la técnica FR en línea hasta el momento, tales como el filtrado y la repetitividad en los resultados. Las pruebas fueron realizadas sobre un transformador trifásico de 5 kv, 1150/345 V y un transformador monofásico de 3 kv, 7620/240 V, en el Laboratorio de lta tensión de la Universidad del Valle. Palabras clave: FR en línea, FR on-load, transformada de Fourier, análisis MR, filtrado, transformador, análisis multirresolución. Received: February 7th 2013 ccepted: March 15th 2013 12 1 Eduardo Gómez-Luna. Ingeniero Eléctrico, Universidad del Valle, Colombia. ffiliation: Universidad del Valle, Colombia. E-mail: eduardo.gomez@correounivalle.edu.co 2 Guillermo ponte. PhD in Ingeniería con énfasis en Ingeniería Eléctrica, Universidad del Valle, Colombia. ffiliation: Universidad del Valle, Colombia. E-mail: guillermo.aponte@correounivalle.edu.co 3 Wilder Herrera. Ingeniero Eléctrico, Universidad del Valle, Colombia. ffiliation: Universidad del Valle, Colombia. E-mail: wilderh2@hotmail.com 4 Jorge Pleite Guerra. PhD en Ingeniería con énfasis en Ingeniería eléctrica, Universidad Carlos III de Madrid, Spain. ffiliation: Universidad Carlos III de Madrid, Spain. E-mail: pleite@ing.uc3m.es How to cite: Gomez-Luna, E., ponte, G., Herrera, W., Pleite, J., Experimentally obtaining on-line FR in transformers by injecting controlled pulses., Ingeniería e Investigación. Vol. 33, No. 1. pril 2013, pp. 41-45. Introduction Frequency response analysis (FR) is a technique which is used to evaluate the state of transformers; it is used worldwide as a complement and for supporting other diagnostic techniques. This test leads to detecting possible mechanical problems, such as displacement or deformation in the windings or core plates which are quite difficult to locate when using other methods. Two methods are used for obtaining the frequency response in transformers according to the nature of the input signal. Sweep frequency response analysis (SFR) consists of injecting a periodic small-signal amplitude (1-20 VRMS) sinusoidal signal and variable frequency in a Hz to MHz bandwidth, applied to one of the terminals. This measures the output signal at another of its terminals to obtain the transformer transference function, defined 41

EXPERIMENTLLY OBTINING ON-LINE FR IN TRNSFORMERS BY INJECTING CONTROLLED PULSES as the quotient between input and output voltages for all frequency points being measured. The second method, impulse frequency response analysis (IFR), uses an impulse-type single non-periodic signal, having a maximum value in the order of hundreds of volts and broad frequency content. It is injected by any of the transformer s accessible terminals as excitation or input signal; the output signal is, likewise, measured at another transformer terminal and the frequency response is thus obtained. particular transformer must be taken out of service (off-line) for the FR test (using the SFR or IFR method) which is why FR with the transformer in service (on-line) is an attractive alternative, as this will permit the transformer to be monitored at all times and reduce the costs associated with performing the test (Leibfried and Feser 1999; Krieg and Napolitano 2000; Feser et al., 2000). Some work has dealt with testing frequency response with online transformers via the impulse technique (IFR) (Christian et al., 1999; Vandermaar 2001; De Rybel et al., 2010; Gomez-Luna et al., 2012); however, this has detected that certain aspects must be improved, like recording equipment sampling frequency, filtering noise by the power system and test repetition (Wang 2003). The methods proposed until now for on-line IFR have been based on pulses randomly generated by manoeuvres or by atmospheric discharges, signals over which there is no control regarding the generated transient (Birlasekaran and Fetherston 1999; René Wimmer 2004; (Coffeen 2003; Coffeen 2007; Coffeen et al., 2009) This article proposes a new method for on-line IFR by injecting controlled pulses. proposed method for an on-line FR test on transformers The proposed on-line IFR experimental method consisted of three stages (presented in Figure 1). Stage 1 Stage 2 Stage 3 Injection and measurement of the signal Injection of the signal in the time domain Voltage Measurement Online with wide bandwidth - Voltage sensors Current Measurement Online with wide bandwidth - Current sensors Signal processing Data register Filtered Mathematical processing of signals Obtaining and analysis of information Obtaining of on-line FR Information nalysis The injection system allowed the amplitude, width and phase of the pulse generated on the 60-Hz wave to be changed, ensuring that it had high spectral content and that there was total control over it. Power system C Power supply (Rectifier) Transformer under test (System and load) Figure 2. Injection circuit block diagram 120V C Vint + -- Rectifier Transformer under test R1 R2 + 12 V R7 L O D R6 R5 R3 Bushing Tap Coupler (BTC) R4 6 7 1 2 4 5 LM 555 trigg 8 C2 Ferrite transformer for High Voltage 3 + V 8-18VDC 1K zero crossing detector (LM 555) Coupling circuit for sending controlled pulses (BTC) 0,001μF Figure 3. High-frequency controlled pulse injection circuit R9 10K 2 4 R8 LM 555 8 1 5 C3 6 7 3 33Ω + 12 V Potentiometer The electronic circuit consisted of a 60-Hz wave (LM 555) zero crossing detector for controlling the injection moment and a power transistor for generating a low-duration short circuit (µ sec) in series with a ferrite transformer. The pulse was controlled through the transistor s saturation time. The controlled pulse on the 60-Hz signal was the input signal for the on-line IFR test; it was sent to the LV side of the transformer being tested through a high-voltage capacitor serving as a low frequency high-pass filter and high frequency low-pass filter. The ferrite transformer isolated the injection circuit of the transformer being tested. Figure 4 shows that the response (pulses in the current signal) was in phase with the injected voltage signal. Figure 1. FR test stages using on-line transformers Stage 1 referred to injecting the excitation signal and its measurement along with the output signal. Once the input/output signal had been injected and measured, stage 2 dealt with signal mathematical filtering, recording and processing. Stage 3 consisted of obtaining the FR curve using mathematical tools. Stage 1: Injection and signal measurement Regarding the injection system, an electronic circuit was specifically designed for injecting controlled pulses on the 60-Hz signal (Figures 2 and 3). Figure 4. Controlled pulse regarding the 60-Hz signal, applied to on-line IFR measurement Broad bandwidth sensors, high-voltage sensors for the voltage pulses and Rogowski coils for the current (Figure 5) were used to measure the voltage and current signals thereby allowing transient registry without saturation problems, bearing in mind 42 INGENIERÍ E INVESTIGCIÓN VOL. 33 No. 1, PRIL 2013 (41-45)

GOMEZ-LUN, PONTE, HERRER ND PLEITE that the pulses were short duration and had high spectral content. High Low V Z PCI-6115 data acquisition card (National Instrument) was used for obtaining the signal registry (voltage-current). The current and voltage temporal signal spectrum was obtained by mathematical processing of the fast Fourier transform (FFT), calculating the transformer s on-line impedance, Z(w), as quotient between voltage, V(w) and current, I(w) for all frequency components. Z V V High Low Current sensor (Rogowski) Voltage sensor (High Voltage probe) Source pulse injection Figure 5. On-line IFR measurement scheme configuration in a transformer Stage 2: Signal registry and processing The controlled pulses on the voltage signals and the response ones in the current signal could be affected by the electrical system s harmonic distortion and background noise which is why suppression signals had to be used for eliminating unwanted signals. In this case, filtering techniques were used based on discrete wavelet transform (DWT) multi-resolution (MR). db4 mother wavelet was selected to eliminate electrical system noise; it was used to filter the electrical signal (Butler-Purry and Bagriyanik 2003; Zheng, Liu, and Ma 2010). This decomposed lowand high-frequency signals by using high-pass g[n] and low-pass h[n] filters (as indicated in Figure 6: Dn represented highfrequency information and approximations and n the lowfrequency information). FFTv ( t) ( ) Z( ) (1) FFT ( ) i( t) Stage 3: Obtaining and analysing information The signal spectra and transformer impedance computed from on-line records, measured while the transformer was energised, were juxtaposed with the corresponding frequency response computed from off-line measurements (SFR method) using Megger FRX 101 equipment in the test configurations shown in Table 1. lthough the international standard for measuring frequency response (IEC 60076-18 2012) only considers open circuit testing for off-line FR, short circuit measurements have also been considered in this study. Table 1. Measurement configurations for comparing on-line and off-line FR Off-line FR On-line IFR (equipment: Megger (proposed method) FRX 101) - One winding (side 1) open. Measurement at one winding - Other winding (side 2) energised Case 1 (side 1) with no load in the - Injection and measurement at open other (side 2) Case 2 winding (side 1) - One winding (side 1) with load Measurement at one winding - Other winding (side 2) energised (side 1) with the other (side 2) - Injection and measurement at short circuited loaded winding (side 1) Table 1 was devised for providing a frame of reference to parallel off-line FR and on-line IFR methods. Case 1 considered noload (open circuit) test conditions where the core magnetic circuit effect was predominant. Case 2 concerned full-load situations where winding field leakage became significant. However, the parallel was not complete in case 2, given that the shortcircuit test was performed with reduced voltage excitation (no significant core magnetic effects) for off-line FR, whereas the transformer had nominal voltage excitation for on-line IFR tests to simulate on-line (in service) conditions. Experimental validation Computer system Recorder NI PCI 6115 Power source Load Figure 6. Decomposition tree used for MR analysis MR analysis of DWT was used to eliminate harmonics; however, in this case, the db10 mother wavelet was used with just the voltage and current transient remaining to be analysed by signal processing and for obtaining the transformer s frequency spectrum. Transformer under test Injection system Figure 7. Experimental setup for on-line FR INGENIERÍ E INVESTIGCIÓN VOL. 33 No. 1, PRIL 2013 (41-45) 43

EXPERIMENTLLY OBTINING ON-LINE FR IN TRNSFORMERS BY INJECTING CONTROLLED PULSES Figure 7 shows the experimental setup used for obtaining a frequency response by injecting controlled pulses (indicating the main on-line test components). The proposed method was applied using load and no-load conditions on the transformer shown in Figure 8. Single-phase Transformer U X u x High voltage winding Low voltage winding Power [kv]: 3 Voltage [V]: 7620/240 Current []: 0.394/12.5 Pn 10 5 Off-line FR at Low Voltage side. High voltage side short circuited Figure 12. Off-line FR reference curve in short circuit conditions. Measured at low voltage winding (ux) with high voltage winding (UX) short circuited (See case 2, Table 1) 10 5 On-line IFR curve at loaded low voltage side Off-Line FR curve Figure 8. Single-phase distribution transformer being tested 10 5 Off-Line FR curve ux Off-Line Reference curve Frecuencia (Hz) Figure 9. Off-line FR reference curve using Megger FRX 101 equipment, measured at low voltage winding (ux) with high voltage winding (UX) open (see case 1, Table 1) Magnitude Z 10 5 Off-lineFR curve Off-line reference curve Figure 10. Off-line FR reference curve using controlled pulse (off-line IFR) measured at low voltage winding (ux) with high voltage winding (UX) open (see case 1, Table 1) 10 5 On-line FR Curve in the Low Winding Test 1 on-line curve Test 2 on-line curve Test 3 on-line curve Figure 11. On-line IFR measurement and pulse injection at low voltage winding (ux) with high voltage winding (UX) energised by the power source (see case 1, Table 1) Figure 13. On-line IFR in load conditions. Measurements and pulse injection made at low voltage winding (ux) with high voltage winding (UX) energised by the power source (See case 2, Table 1) Magnitude Z 10 5 off-line/on-line FR curve Test 1 on-load curve Test 2 on-load curve Test 3 on-load curve Test 1 on-line curve Test 2 on-line curve Test 3 on-line curve Test 4 on-load curve Test 5 on-load curve Test 6 on-load curve off-line Reference Figure 14. Comparing off-line/on-line IFR curves at the low voltage winding (ux) Figures 9 to 14 show the corresponding results. The transformer was tested under 100% load, supplying power to a resistive load in the on-line IFR tests in load conditions. The results revealed a good response in the 10 khz 1 MHz range; this may have been because the low-frequency signals (<10 khz) were greatly affected by the filtering and load system. The high frequency range on-line curves had resonance which was not present in the off-line curves; this could have been associated with the parasitic capacitance effect of the measurement cables, the load and the whole system connected to the transformer, thereby making the impedance seen unequal. It could also have been attributed to using two different sets of measurement equipment (Megger FRX 101 for off-line FR and PCI- 6115 recorder for on-line IFR) and the difference between test conditions. Nevertheless, despite the differences between off-line and on-line curves, monitoring the transformer s physical condi- 44 INGENIERÍ E INVESTIGCIÓN VOL. 33 No. 1, PRIL 2013 (41-45)

GOMEZ-LUN, PONTE, HERRER ND PLEITE tions was based on continuous tracking of changes in the frequency response curve (either off-line or on-line), given that good repetition of the curves was obtained with it, this being one of the basic FR technique requirements for supporting transformer diagnosis. So far, all progress in relation to the on-line IFR method involved using FFT for signal processing; however, by definition, this tool would have been useful for processing stationary signals. Taking that into consideration, transient signal analysis could be hypothetically improved by using wavelet transform for signal processing, given its variable time/frequency resolution (Gomez- Luna et al., 2012; Duarte et al., 2012), thereby forming the basis for future work which the authors are currently working on. Conclusions This article has contributed towards obtaining a frequency response in on-line transformers by injecting controlled pulses into the 60-Hz wave. lthough the experimentally proposed method was viable, further signal processing research is needed, given that measurements sometimes become altered by the noise present in a power system, thereby affecting measurement repetition. The on-line impedance at high frequencies differed from the offline measurement. This may have been due to the effect of the parasitic capacitance associated with the measurement cables and the load connected to the transformer. Work on on-line IFR has involved using the Fourier transform as the mathematical tool to date; the method proposed here has suggested using wavelet transform, given its good response in analysing transient signals. cknowledgments The authors would like to express their gratitude to COLCIEN- CIS for the finance received through project 494-2009, as well as Spanish government financing through project DPI2008-05890. We would also like to thank the Universidad del Valle s High- Voltage Laboratory and the Research Vice-Rector s office for providing funding, facilities and making equipment available for the tests. References Birlasekaran, S. & Fetherston, F., Off / On-Line FR Condition Monitoring Technique For Power Transformer. IEEE power Engineering Review, (732), 1999, pp.54 56. Butler-purry, K.L. & Bagriyanik, M., 2003. Characterization of transients in transformers using discrete wavelet transforms. IEEE Transactions on Power Systems, 18(2), 2003, pp.648 656. Christian, J. Feser, K. Sundermann, U. Leibfried, T. Diagnostics of power transformers by using the transfer function method. Conference Publication No. 467, High Voltage Engineering Symposium, 22-27 ugust 1999. Coffeen, L. Mcbride, J. Woldemariam, N. Benach, J. Summary of NEETRC On-line Frequency Response nalysis ( FR ) a New EPRI Commercial Prototype FR Installation at First Energy. NEET- RC and EPRI, EPRI Substation Equipment Maintenance Optimization & Diagnostics Conference San ntonio, TX March 2009, pp.1 24. Coffeen, L. Cantrelle, D. and Mango J. On-Line Monitor Tracks Transformer Health. Transmission & Distribution World; Vol. 59 Issue 10, p62, Power & Light; October. 2007. [Online], vailable: http://connection.ebscohost.com/c/articles/27325791/on-linemonitor-tracks-transformer-health Coffeen, L. System and Method for On-Line Impulse Frequency Response nalysis. U. S, Patent 6549017B2, pril 15, 2003. Duarte, C. Delmar, P. Goossen, K. Barner, K. Gomez-Luna E. Non- Intrusive Load Monitoring Based on Switching Voltage Transients and Wavelet Transforms. International Workshop Future of Instrumentation (FIIW), pp. 1-4, October 2012. De Rybel, T. Singh,. Pak, P. and Marti, J. R. Online Signal Injection Through a Bus-Referenced Current Transformer. IEEE Transactions on Power Delivery, vol. 25, no. 1, pp. 27-34, January 2010. Feser, K. Christian, J. Leibfried, T. Kachler,. Neumann, C. Sundermann, U. Loppacher, M. The Transfer Function Method for Detection of Winding Displacements on Power Transformers after Transport, Short Circuit or 30 Years of Service. CIGRE, Paris,. 2000. pp. 1-13. Gomez-Luna, E. ponte, G. Gonzalez-Garcia, C. Pleite, J. Current Status and Future Trends in Frequency-Response nalysis with a Transformer in Service. IEEE Transactions on Power Delivery, December 08, 2012, pp.1 8. ccepted for publication. DOI: 10.1109/TPWRD.2012.2234141. Gómez-Luna, E. Silva, D. ponte, G. Pleite, J. and Hinestroza, D. Obtaining the electrical impedance using wavelet transform from the time response. IEEE Power Eng. Lett., Dec. 04, 2012, accepted for publication. Digital Object Identifier: 10.1109/TPWRD.2012.2234942. IEC 60076-18 International Standard: Power transformers. Part 18: Measurement of Frequency Response International Electrotechnical Commission, Ed. 1, July 2012. Krieg, T. & Napolitano, M., Techniques and experience in on-line transformer condition monitoring and fault diagnosis in Electra- Net S. International Conference on Power System Technology. Proceedings, 2000, pp.1019 1024. Leibfried, T. and Feser, K. Monitoring of power transformers using the transfer function method. IEEE Transactions on Power Delivery, vol. 14, no. 4, pp. 1333-1341, Oct. 1999. Vandermaar,. On-line Frequency Response nalysis System. Development of Specifications. EPRI Project Manager, Technical Progress, Development of Specifications No. 1001942, EPRI, Palo lto, Canada, December 2001. Wimmer, R. and Feser, K. Calculation of the transfer function of a power transformer with online measuring data. II International Conference on dvances in Processing, Testing and pplications of Dielectric Materials, pp1-5, September 2004. Wang, M. Winding movement and condition monitoring of power transformers in service. Department of Electrical and Computer Engineering, Thesis PhD, University of British Columbia, 2003. Zheng, E. Liu, Z. Ma. L. Study on Harmonic Detection Method Based on FFT and Wavelet Transform. 2nd International Conference on Signal Processing Systems, (ICSPS). Pp. 1-4 IEEE 2010. INGENIERÍ E INVESTIGCIÓN VOL. 33 No. 1, PRIL 2013 (41-45) 45