2-Pair. Managed SHDSL Ethernet Extender. User s Manual



Similar documents
Long Range Ethernet Extender

SHDSL LAN EXTENDER H301A. User Manual

V101. VDSL LAN Extender

VDSL2 LAN Extender User Manual

Ethernet over VDSL2 PoE PD Converter

LevelOne User Manual VDS-0120 Ethernet over VDSL2 Converter (PSE)

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

ALL8808POE. 8 Port Gigabit PoE+ Switch. Manual

Quick Installation Guide. EtherFast 10/100M Switch. Model No.: SP624R.

GEU Port Gigabit Switch

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

SOHOware Long Reach Ethernet (LRE) Solution

FlexDSL MiniFlex. SHDSL.bis Up to 30Mbps Ddd. Ethernet. Features. Possible Applications

8 Port Gigabit 10M/100M/1000M Fast Ethernet Switch. User Manual

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Megapixall Security Tools & Accessories

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

FSW-0505TX/0805TX 5/8 Port SOHO 10/100Mbps NWay Switch FSW-0505TX FSW-0805TX. 5/8 Port SOHO 10/100Mbps NWay Switch. User s Manual. (Revision 1.

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

Gigabit Switching Ethernet Media Converters - Product User Guide

Gigabit Desktop. manual Models & Model shown: INT / UM

DES-1005P 5-Port 10/100Mbps with 1-Port PoE Unmanaged Switch

MDI/MDIX) FEP-32008T-3

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

User Guide TL-SG1016/ TL-SG /24-port Gigabit Ethernet Switch

8-Port 10/100Mbps 802.3at PoE + 1-Port 10/100/1000Mbps Desktop Switch

4 Ports + 3 SFP Gigabit Smart Switch Use Manual. Ver.A0

IFS SP-PoE Splitter User Manual

PoE+ Extender Switch User's Manual. Rev W

Provides one channel for Ethernet over existing

Copper to Fiber Stand-Alone Media Converter. Quick Installation Guide

YM.SW.105.UM.EN.D00REV FH11 Fri Jul 25 16:00: Page 1

N560 series H/W Installation Guide

PLI-3310 HomePlug Pro Power Bridge

Wireless Router Setup Manual

CONTRIBUTION ABSTRACT

palm Switch Port 10/100 Base-TX Switch with Auto MDI/MDI-X User Guide

T3 Mux M13 Multiplexer

Ethernet over VDSL2 Converter VC-201A / VC-204

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

8-Port 10/100M N-Way Mini Switch

MICROSENS Media Converter 10/100/1000T to Gigabit Fiber

8-Port PoE Network Switch

Moxa EtherDevice Switch

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

16-Port and 24-Port 10/100 Switches

FILTERING/FORWARDING RATES 100Mbps port - 148,800pps 10Mbps port - 14,880pps. TRANSMISSION MEDIA 10BaseT Cat. 3, 4, 5 UTP/STP 100BaseTX Cat.

Quick Installation Guide. 16-Port 10/100Mbps Fast Ethernet Switch

Provides one channel for Ethernet over existing

Manageable 10/100/1000 Mbs Ethernet Modular Multi-Media Switch

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

Speed-DSL 9.2 Ethernet connection over 8-wires up to 9.2 Mbit/s. Manual * * * *

TP-LINK TECHNOLOGIES CO.,LTD. Website ADD FI.3,Bldg.R1-B.High-Tech Industrial Park,Shenzhen

How To Replace A 10/100Mbps Switch With A G1005D/G1008D (Mini) And G100D/ G1008D (Mini And Mini) (Mini/Mini) (Micro) (Power) (

4-Port 10/100Base-TX with PoE + 1-Port BNC / RJ-11 Industrial Ethernet Extender

VOICE RECORDING SYSTEM ISDN PRI / BRI

Perle 10/100 Ethernet Media Converters

Loop-IP6700 TDMoEthernet

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual

Turning Copper into Gold

Terminal and Dimension

User Manual IC-485AI

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

Public Switched Telephone System

User Guide. MC100CM MC110CS Fast Ethernet Media Converter. MC111CS MC112CS WDM Fast Ethernet Media Converter

Terminal and Dimension

S-Access Etherlink II Repeater TDM Based SHDSL.bis

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

4-Band VDSL CO/CPE MODEM USER S MANUAL Ver. A.2. 4-Band VDSL CO/CPE Modem USER S MANUAL

500M Powerline Pass-Through Ethernet Bridge

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

TrueAlarm Fire Alarm Systems

LBNP RS-232/485/422 serial device server. User manual

VDSL Ethernet Extender AT-MC605. Installation Guide Rev. C

Optimux-134, Optimux-125

EGS7228P. Business Class EGS7228P. 24-port Gigabit AT PoE + 4SFP Smart Switch PRODUCT OVERVIEW

User's Manual. 8-Port 10/100Mbps with 4-Port PoE Fast Ethernet Switch FSD-804P - 1 -

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

PT100 Portable TAP. User Guide. Revision 1.0

ProCurve Switch 8000m (J4110A) and Switch 8000m

Extending E1 and Ethernet using the same Copper Pairs

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

48 GE PoE-Plus + 2 GE SFP L2 Managed Switch, 375W

Loop-IP6702 TDMoEthernet

Optimux-34, Optimux-25

Media Converters & Chassis

Connecting the DG-102S VoIP Gateway to your network

Optimux-134, Optimux-125

FCC Certifications. CE Mark Warning

User Guide TL-SG1016D 16-Port Gigabit Switch TL-SG1024D 24-Port Gigabit Switch

Transcription:

2-Pair User s Manual

1. Quick Start Guide This quick start guide describes how to install and use the Managed SHDSL Ethernet Extender. This is the Ethernet Extender of choice to extend 10/100 Ethernet circuits by using existing straight pair copper wire. 1.1. Physical Description 1.1.1. The Port Status LEDs and Power Inputs LEDs State Indication POWER (Green) On Power supply is normal. TEST (Yellow) On Self testing after powered on. Line LOOP1 (Green) Flash SHDSL connection is in progress. On Loop1 connects successfully. LOOP2 (Green) Flash SHDSL connection is in progress. On Loop2 connects successfully. Ethernet LAN1 (Green) On LAN1 port is in connection. Flash Data activity on LAN1 port. 10/100M (Green) On LAN1 Ethernet connection is at 100Mbps. LAN2 (Green) On LAN2 port is in connection. Flash Data activity on LAN2 port. 10/100M (Green) On LAN2 Ethernet connection is at 100Mbps. 1

1.1.2. The 10/100Base-TX and Ethernet Extender Connectors The 10/100Base-TX Connection (LAN1 and LAN2 ports) The following lists the pinouts of 10/100Base-TX RJ-45 connector. Pin Regular Ports Uplink ports 1 Output Transmit Data + Input Receive Data + 2 Output Transmit Data - Input Receive Data - 3 Input Receive Data + Output Transmit Data + 4 NC NC 5 NC NC 6 Input Receive Data - Output Transmit Data - 7 NC NC 8 NC NC The Ethernet Extender Connection (Line port) The RJ-48 interface pinouts for SHDSL line port. Pin 4 & Pin 5 for Loop 1. Pin 1 & Pin 2 for Loop 2. 1.1.3. The Data Rate and Distance of Ethernet Extender Port 1 pair 2 pair Max. Reach (m) Max. Reach (ft.) Data Rate (Kbps) Data Rate (Kbps) 4,608 9,216 1,828 6,000 3,072 6,144 2,895 9,500 2,304 4,608 3,505 11,500 2,048 4,096 3,657 12,000 1,544 3,088 3,962 13,000 1,152 2,304 4,419 14,500 768 1,536 4,572 15,000 512 1,024 5,029 16,500 384 768 5,334 17,500 256 512 5,791 19,000 192 384 6,248 20,500 <Note> This table is based on SHDSL connection with 1dB noise. 2

1.2. Functional Description ITU-T Rec. G.991.2 G.shdsl.bis Compliance. SHDSL Trellis Coded Pulse Amplitude Modulation (TCPAM) Line Code. Fixed Data Rate Selection from 10.8Mbps to 128Kbps for 2-pair SHDSL lines. Adaptive Data Rate from 4608Kbps to 192Kbps for 1-pair SHDSL mode. Adaptive Data Rate from 9216Kbps to 384Kbps for 2-pair SHDSL mode. Maximum Transmission Distance: 22,500 ft over 26AWG twisted pair. Noise Margin 1 db is guaranteed for fixed rate and adaptive rate modes. Remote side follows central side s speed for 192Kbps~2304Kbps in 1-pair fixed rate mode. Remote side follows central side s speed for 384Kbps~4608Kbps in 2-pair fixed rate mode. RJ-48 Interface for SHDSL line connections. Two RJ-45 Connectors for 10/100Base-TX Ethernet Switch ports. Ethernet Auto-Negotiation for 10/100Base-TX. Ethernet Auto-MDIX for Auto Tx/Rx Swap. Console Port for Network Management Configurations. 8 LED status indicators. Power feedings: 100/240VAC. 1.3. Console Configuration The Ethernet Extender provides an RS232C console port for user to monitor the OA&M status through a VT100 terminal. Connect the RS232 cable from the COM port of the personal computer to RS232C console port of Ethernet Extender. Set the personal computer to VT100 or VT102 type through HyperTerminal. Press the <ESCAPE> key and the main menu will be shown on the screen of the terminal. The terminal operations can then start. If the <ESCAPE> key is pressed and the screen of the terminal does not display, this may be due to the incorrect COM port setting. Choose the right COM port (COM1 or COM2) on the personal computer, and press the <ESCAPE> key again to make sure that the main menu appears on the terminal screen. Note that the COM port should be set as below. 3

Baud rate Data bits Parity Stop bit Flow control 9600bps 8 none 1 none 1.3.1. Main Menu Main Menu will display the connection status of the Ethernet Extender and settings including two sections: Configuration, and Status. 1.3.2. Pull-down Tree Structure of Main Menu The pull-down tree structure of the main menu is shown as below. 4

1.4. Installation Procedures Connect both Ethernet Extenders to the AC outlet by power cords and turn on both Ethernet Extenders by turning on the power switches of both Ethernet Extenders. Please refer Console Configuration section to configure both Ethernet Extenders. Type 1 in Main Menu screen to select 1 Configuration. Type 1 in Configuration screen to select 1 DSL Mode. Set CO/RT to STU-C in DSL Mode screen for one Ethernet Extender at Central Side and set CO/RT to STU-R in DSL Mode screen for another Ethernet Extender at Remote Side. It is necessary to set Ethernet Extender to STU-C and the other Ethernet Extender to STU-R to establish a successful connection for two Ethernet Extenders. Set PAIR to 1 Pair or 2 Pairs in DSL Mode screen for both Ethernet Extenders at Central Side and Remote Side. It is necessary to set the two Ethernet Extenders to the same selection (1 Pair or 2 Pairs) to establish a successful connection for two Ethernet Extenders. Type 1 in Main Menu screen to select 1 Configuration. Type 2 in Configuration screen to select 2 DSL Speed. The user must set both Ethernet Extenders to the same speed selection in order to establish a successful connection. Turn off both Ethernet Extenders by turning off the power switches of both Ethernet Extenders. Connect CAT.5 UTP Ethernet straight cable with RJ-45 connectors or straight telephone cable with RJ-45 connectors (2 pairs with Pin 4 & Pin 5 for Loop 1 and Pin 1 & Pin 2 for Loop 2) to Line ports (Ethernet Extender port with RJ-48 interface) of both Ethernet Extenders. Turn on both Ethernet Extenders by turning on power switches of both Ethernet Extenders. Both Ethernet Extenders will then execute self-test routines. Please wait for LOOP1 LED (1 pair) or both LOOP1 and LOOP2 LEDs (2 pairs) of both Line ports becoming stable on. The maximum fixed data rate is 5696Kbps and 10.8Mbps for 1-pair and 2-pair mode. The maximum adaptive rate is 4608Kbps and 9216Kbps for 1-pair and 2-pair mode. When setting for adaptive rate, 2 or more activation cycles are necessary. Both Ethernet Extenders will automatically adapt to maximum speed according to loop distances. Approximate 2~3 minutes for the LOOP1 LED (1 pair) or both LOOP1 and LOOP2 LEDs (2 pairs) of both Line ports become stable on. Note that this Ethernet Extender supports two Ethernet Switch ports (LAN1 and LAN2 ports) with RJ-45 connectors. Connect Ethernet to either LAN1 or LAN2 port of both Ethernet Extenders with CAT.5 UTP Ethernet straight cable with RJ-45 connectors. 5

2. Table of Contents 1. QUICK START GUIDE... 1 1.1. PHYSICAL DESCRIPTION... 1 1.1.1. The Port Status LEDs and Power Inputs... 1 1.1.2. The 10/100Base-TX and Ethernet Extender Connectors... 2 1.1.3. The Data Rate and Distance of Ethernet Extender Port... 2 1.2. FUNCTIONAL DESCRIPTION... 3 1.3. CONSOLE CONFIGURATION... 3 1.3.1. Main Menu... 4 1.3.2. Pull-down Tree Structure of Main Menu... 4 1.4. INSTALLATION PROCEDURES... 5 2. TABLE OF CONTENTS... 6 3. INTRODUCTIONS... 7 4. APPLICATION NOTES... 7 5. FEATURES... 8 6. PACKING CONTENTS... 8 7. INSTALLATION PROCEDURES... 9 8. FRONT PANEL LED INDICATORS... 11 9. CONSOLE PORT CONTROL... 12 U 9.1. MAIN MENU... 13 9.2. CONFIGURATION SCREEN... 14 9.3. STATUS SCREEN... 18 10. SPECIFICATIONS... 22 6

3. Introductions The, an SHDSL (Single-pair High-bit-rate Digital Subscriber Line) LAN Extender, provides a broadband full duplex transmission with bandwidth aggregation up to 10.8Mbps over 2 pairs of copper line for point-to-point LAN connectivity between two Ethernet networks. The distance can reach up to 7,000 feet (about 2.1 Km) and 10,000 feet (about 3 Km) at the maximum rate of 10.8Mbps and 9.216Mbps for two pairs of 24AWG (0.5 mm) copper wire, and could reach even around 22,500 feet (about 6.8 Km) for 192Kbps. With its rate adaptive features, this may provide longer reach on transmission distance. Users can also select a fixed data rate for the copper line ranging from 192Kbps to 10.8Mbps. The Managed SHDSL Ethernet Extender provides a console port for user to configure the settings and to monitor the connection status. Each can be configured into either STU-C for central side or STU-R for remote side. The conforms to the ITU-T Rec. G.991.2, to meet G.shdsl.bis network requirements. A pair of offers a cost effective symmetrical broadband solution for bandwidth-hungry applications such as LAN-to-LAN connectivity, Internet Access and VoIP applications over two twisted pairs. 4. Application Notes Ethernet To Ethernet Bridge Extension Ethernet Interface 10.8Mbps at 7,000 ft Ethernet Interface Central Office STU-C SHDSL Copper Lines Remote Side STU-R 7

5. Features ITU-T Rec. G.991.2 G.shdsl.bis Compliance. SHDSL Trellis Coded Pulse Amplitude Modulation (TCPAM) Line Code. Fixed Data Rate Selection from 10.8Mbps to 128Kbps for 2-pair SHDSL lines. Adaptive Data Rate from 4608Kbps to 192Kbps for 1-pair SHDSL mode. Adaptive Data Rate from 9216Kbps to 384Kbps for 2-pair SHDSL mode. Maximum Transmission Distance: 22,500 ft over 26AWG twisted pair. Noise Margin 1 db is guaranteed for fixed rate and adaptive rate modes. Remote side follows central side s speed for 192Kbps~2304Kbps in 1-pair fixed rate mode. Remote side follows central side s speed for 384Kbps~4608Kbps in 2-pair fixed rate mode. RJ-48 Interface for SHDSL line connections. Two RJ-45 Connectors for 10/100Base-TX Ethernet Switch ports. Ethernet Auto-Negotiation for 10/100Base-TX. Ethernet Auto-MDIX for Auto Tx/Rx Swap. Console Port for Network Management Configurations. 8 LED status indicators. Power feedings: 100/240VAC. 6. Packing Contents Inside the package you should find: (1) One unit with dimension of 260x151x44 (mm) (2) One power cord (3) One RS232 cable (4) One CAT 5 Ethernet Cable (5) One Quick Start Guide and User s Manual Please check if the packing is damaged before unpacking or any component is missing. If so, please contact your dealer immediately for replacement. 8

7. Installation Procedures Step 1: Connect both Ethernet Extenders to the AC outlet by power cords and turn on both Ethernet Extenders by turning on the power switches of both Ethernet Extenders. Step 2: Please refer Console Configuration section to configure both Ethernet Extenders. Type 1 in Main Menu screen to select 1 Configuration. Type 1 in Configuration screen to select 1 DSL Mode. Step 3: Set CO/RT to STU-C in DSL Mode screen for one Ethernet Extender at Central Side and set CO/RT to STU-R in DSL Mode screen for another Ethernet Extender at Remote Side. It is necessary to set Ethernet Extender to STU-C and the other Ethernet Extender to STU-R to establish a successful connection for two Ethernet Extenders. Step 4: Set PAIR to 1 Pair or 2 Pairs in DSL Mode screen for both Ethernet Extenders at Central Side and Remote Side. It is necessary to set the two Ethernet Extenders to the same selection (1 Pair or 2 Pairs) to establish a successful connection for two Ethernet Extenders. Step 5: Type 1 in Main Menu screen to select 1 Configuration. Type 2 in Configuration screen to select 2 DSL Speed. The user must set both Ethernet Extenders to the same speed selection in order to establish a successful connection. Step 6: Turn off both Ethernet Extenders by turning off the power switches of both Ethernet Extenders. Step 7: Connect CAT.5 UTP Ethernet straight cable with RJ-45 connectors or straight telephone cable with RJ-45 connectors (2 pairs with Pin 4 & Pin 5 for Loop 1 and Pin 1 & Pin 2 for Loop 2) to Line ports (Ethernet Extender port with RJ-48 interface) of both Ethernet Extenders. 9

Pin 4 & Pin 5 for Loop 1 Pin 1 & Pin 2 for Loop 2 RJ-48 Interface Pin Assignment for SHDSL Line Port Step 8: Turn on both Ethernet Extenders by turning on power switches of both Ethernet Extenders. Both Ethernet Extenders will then execute self-test routines. Please wait for LOOP1 LED (1 pair) or both LOOP1 and LOOP2 LEDs (2 pairs) of both Line ports becoming stable on. The maximum fixed data rate is 5696Kbps and 10.8Mbps for 1-pair and 2-pair mode. The maximum adaptive rate is 4608Kbps and 9216Kbps for 1-pair and 2-pair mode. When setting for adaptive rate, 2 or more activation cycles are necessary. Both Ethernet Extenders will automatically adapt to maximum speed according to loop distances. Approximate 2~3 minutes for the LOOP1 LED (1 pair) or both LOOP1 and LOOP2 LEDs (2 pairs) of both Line ports become stable on. Step 9: Note that this Ethernet Extender supports two Ethernet Switch ports (LAN1 and LAN2 ports) with RJ-45 connectors. Connect Ethernet to either LAN1 or LAN2 port of both Ethernet Extenders with CAT.5 UTP Ethernet straight cable with RJ-45 connectors. 10

8. Front Panel LED Indicators There are 8 LED indicators on the front panel of the Managed SHDSL Ethernet Extender displaying the current status. These LED indicators are described as following. POWER: Green On shows power supply is normal. TEST : Yellow On shows is self testing after powered on. LOOP1 : Green Flash shows SHDSL connection is in progress. : Green On shows SHDSL loop1 connects successfully. LOOP2 : Green Flash shows SHDSL connection is in progress. : Green On shows SHDSL loop2 connects successfully. LAN1 : Green On shows LAN1 port is in connection. : Green Flash shows data activity on LAN1 port. 10/100M: Green On shows LAN1 Ethernet connection is at 100Mbps. LAN2 : Green On shows LAN2 port is in connection. : Green Flash shows data activity on LAN2 port. 10/100M: Green On shows LAN2 Ethernet connection is at 100Mbps. 11

9. Console Port Control The provides an RS232C console port for user to monitor the OA&M status through a VT100 terminal. This section covers the operation procedures, settings and for all screen selections. Connect the RS232 cable to the COM port of the computer as shown in the following diagram. Set the personal computer to VT100 or VT102 type through HyperTerminal. Press the <ESCAPE> key and the main menu will be shown on the screen of the terminal. The terminal operations can then start. If the <ESCAPE> key is pressed and the screen of the terminal does not display, this may be due to the incorrect COM port setting. Choose the right COM port (COM1 or COM2) on the computer, and press the <ESCAPE> key again to make sure that the main menu appears on the terminal screen. Note that the COM port should be set as 9600bps, none parity, 8 data bit, and 1 stop bit. RS232 Cable VT100 / 102 Terminal Console Port 9600, N, 8, 1 DB-9 Connector Figure 9-1: Connection for Console Port with RS232 Terminal 12

9.1. Main Menu Main Menu will display the connection status of the Managed SHDSL Ethernet Extender unit and settings including two sections: Configuration, and Status. For details please refer to Table 9-1. Table 9-1 Main Menu The pull-down tree structure of the main menu is shown in Figure 9-2. DSL Mode Configuration DSL Speed Main Menu Default Configuration System Information Status System Status Figure 9-2: Pull-down Tree Structure of the main menu 13

9.2. Configuration Screen Configuration screen will display the selections of connection for the Managed SHDSL Ethernet Extender unit and the screen includes three selections: DSL Mode Settings, DSL Speed Settings, and Default Configuration. For details please refer to Table 9-2. Table 9-2 Configuration screen 14

DSL Mode Settings: Table 9-3: DSL Mode Settings screen This screen provides DSL mode settings and user can update the settings from this screen. CO/RT: The item of CO/RT has 2 options: STU-C and STU-R. To establish a successful connection for two units, it is necessary to set one unit to STU-C and the other unit to STU-R. 2P/1P: The item of 2P/1P has 2 options: 1 Pair and 2 Pairs. This Managed SHDSL Ethernet Extender supports both 1-pair and 2-pair applications. To establish a successful connection for two units, it is necessary to set the two units to the same selection. 15

DSL Speed Settings: Table 9-4 DSL Speed Settings screen This screen provides DSL Speed Settings and user can configure DSL speed to set the transmission rate. For 1-pair setting in the DSL Mode menu, the options are as following; 64Kbps, 128Kbps, 192Kbps, 256Kbps, 384Kbps, 512Kbps, 768Kbps, 1152Kbps, 1536Kbps, 1544Kbps, 2048Kbps, 2304Kbps, 2560Kbps, 3072Kbps, 3584Kbps, 4096Kbps, 4608Kbps, 5120Kbps, 5696Kbps and Adaptive speed. For 2-pair setting in the DSL Mode menu, the options are as following; 128Kbps, 256Kbps, 384Kbps, 512Kbps, 768Kbps, 1024Kbps, 1536Kbps, 2304Kbps, 3072Kbps, 3088Kbps, 4096Kbps, 4608Kbps, 5120Kbps, 6144Kbps, 7168Kbps, 8192Kbps, 9216Kbps, 10.2Mbps, 10.8Mbps and Adaptive speed. The user must set both units of to the same speed selection in order to establish a successful connection for 1-pair 64Kbps, 128Kbps, 2560Kbps, 3072Kbps, 3584Kbps, 4096Kbps, 4608Kbps, 5120Kbps, 5696Kbps, and for 2-pair 128Kbps, 256Kbps, 5120Kbps, 6144Kbps, 7168Kbps, 8192Kbps, 9216Kbps, 10.2Mbps, 10.8Mbps and Adaptive speed. For the rest of speed options from 192Kbps up to 2304Kbps, the STU-R will follow the speed of STU-C. 16

When setting for adaptive rate, 2 or more activation cycles are necessary. The system will automatically adapt to maximum speed according to the loop distances. The maximum speed is 4608Kbps for 1-pair mode and 9216Kbps for 2-pair mode. Default Configuration Setting: Table 9-5 Default Configuration Setting screen When Default Configuration is selected, all the settings of this Managed SHDSL Ethernet Extender will go back to default settings. For the screen as shown in Table 9-5, it indicates setting is finished and press <ESC> key will be back to previous screen. The default settings of this are as following: STU-C 1 Pair Adaptive speed 17

9.3. Status Screen The Status screen shows the connection status of this Managed SHDSL Ethernet Extender unit. The screen covers two selections: System Information and System Status. For details please refer to Table 9-6. Table 9-6 Status screen 18

System Information: Table 9-7 System Information screen Items list in the above screen are explained as follows: Firmware Version: Indicates the firmware version in this unit. Vendor Model: Indicates this device s vendor model name. Vendor Information: Indicates the vendor s web site information. 19

System Status screen: Table 9-8 System Status screen. The distance of this example is 6K ft and 26AWG. Items list in the above screen are explained as follows: DSL mode: Indicates the current DSL mode setting. Speed setting: Indicates the current DSL speed setting. Speed actual (Kbps): Indicates the actual DSL speed in kilobit per second. Link status of pair #1: Indicates the DSL connection status (either up or down) for pair #1. Link status of pair #2: Indicates the DSL connection status (either up or down) for pair #2. Noise Margin of pair #1(dB): Indicates the Noise Margin in db of pair #1. Noise Margin of pair #2(dB): Indicates the Noise Margin in db of pair #2. 20

Line Attenuation of pair #1(dB): Indicates the Line Attenuation value in db of pair #1. The maximum value is 43 db when the DSL distance is 22500 ft, 26AWG. Line Attenuation of pair #2(dB): Indicates the Line Attenuation value in db of pair #2. The maximum value is 43 db when the DSL distance is 22500 ft, 26AWG. Activation state of pair #1(dB): Indicated the DSL startup activation state of pair #1. The value starts from 05 and gradually reaches the final value 16. The value 16 is the DSL link up state value. The general activation state sequence is 05 20 10 12 16. Activation state of pair #2(dB): Indicated the DSL startup activation state of pair #2. The value starts from 05 and gradually reaches the final value 16. The value 16 is the DSL link up state value. The general activation state sequence is 05 20 10 12 16. 21

10. Specifications Applicable Standards Fixed Ports Speed 10Base-T 100Base-TX Ethernet Extender Switching Method Forwarding rate Cable 10Base-T 100Base-TX Ethernet Extender LED Indicators Dimensions Weight Power IEEE802.3 10Base-T, IEEE802.3u 100Base-TX, IEEE802.3x, Ethernet over SHDSL LAN1 and LAN2 ports: 2 x 10/100Mbps Ethernet port with RJ-45 connector Line port: 1 x Ethernet Extender port with RJ-48 interface 10/20Mbps for half/full-duplex 100/200Mbps for half/full-duplex Fixed Data Rate Selection: 128Kbps to 10.8Mbps for 2-pair copper wire Adaptive Data Rate: 192Kbps to 4608Kbps for 1-pair copper wire Adaptive Data Rate: 384Kbps to 9216Kbps for 2-pair copper wire Store-and-Forward 14,880/148,810pps for 10/100Mbps 2-pair UTP/STP Cat. 3, 4, 5 up to 100m 2-pair UTP/STP Cat. 5 up to 100m 24 or 26AWG twisted pair copper wire Per Unit (2 LEDs)- POWER, TEST Per Port- LAN1, LAN2 (RJ-45 connector, 2 LEDs): Link/Activity, Speed Line (RJ-48 interface, 2 LEDs): LOOP1, LOOP2 260mm (W) 151mm (D) x 44mm (H) (10.24 (W) x 5.94 (D) x 1.73 (H)) 2.5Kg (5.51lbs.) 100 ~ 240VAC, 50 ~ 60Hz Internal Universal PSU Power Consumption 8W Max. Operating Temperature 0 C ~ 50 C (32 ~ 122 ) Storage Temperature Humidity Emissions -20 C ~ 70 C (-4 F ~ 158 F) 5% ~ 95%, non-condensing CE Mark, Class A FCC Part 15, Class A VCCI, Class A 22