DCS Data and communication server



Similar documents
DCS data and communication server

DCS Data and Communication Server

Cisco MCS 7825-H3 Unified Communications Manager Appliance

Cisco 7816-I5 Media Convergence Server

Scout 1U Rackmount Computer

System Configuration and Order-information Guide ECONEL 100 S2. March 2009

Cisco MCS 7816-I3 Unified Communications Manager Appliance

How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X

Servers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor

Chapter 5 Cubix XP4 Blade Server

Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I

WP WinPAC-8x49 Series (WP-8149/8449/8849) is the new generation WinCE based InduSoft PAC (Programmable Automation Controller).

Fujitsu PRIMERGY BX600 S3 Blade Server

ROSA Server MKVI. A Complete, Powerful Solution

GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server

LB-IPC. High Performance, Ultra Low Noise Low Power Consumption. Features. Applications

MESOS CB220. Cluster-in-a-Box. Network Storage Appliance. A Simple and Smart Way to Converged Storage with QCT MESOS CB220

Acer AT110 F2 Specifications

Box PC Fanless. Box PC Performance

Display units With alphanumeric screen

TrueAlarm Fire Alarm Systems

High Performance 2U Storage Server. Mass Storage Capacity in a 2U Chassis

Cisco MCS 7825-H2 Unified CallManager Appliance

Overland 2 TB SnapServer 210 NAS Server. Overland 4 TB SnapServer 210 NAS Server Operating System GuardianOS GuardianOS

FUJITSU Enterprise Product & Solution Facts

New levels of efficiency and optimized design. The latest Intel CPUs. 2+1 expandability in UP 1U

HUS-IPS-5100S(D)-E (v.4.2)

QuickSpecs. HP 200 G1 Microtower Business PC. HP 200 G1 Microtower Business PC. Overview

I/A Series HARDWARE Product Specifications

Data Sheet ESPRIMO P1500. The wide-ranging home office and multimedia PC ESPRIMO P1500

Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server

applicomio Profibus-DP

Panel PC SIMATIC HMI IPC577C

NEC EXPRESS5800/R320c-E4 Configuration Guide

Data Sheet Fujitsu ESPRIMO P2440 Desktop PC

DMS-10101, Computer Equipment

Optimized dual-use server and high-end workstation performance

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

High Performance 1U Server. High Performance 1U Storage Server. Front Parallel CPU Design features better cooling

DD670, DD860, and DD890 Hardware Overview

VIA Eden 1GHz ULV Processor AFL-07A-CX2. HDD Drive Bay Optional HSDPA Module (support GSM 850,EGSM 900,DCS 1800 & PCS 1900) Mounting

Easily Upgrade to the Quad Core CPU without Additional Mechanism Rebuilding Costs

Minimum Hardware Specifications Upgrades

Application Server V240 Platform

Vess. Architectural & Engineering Specifications For Video Surveillance. A2200 Series. Version: 1.2 Feb, 2013

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server

2100 POS System User Guide

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.

How To Buy An Fujitsu Primergy Bx400 S1 Blade Server

Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server

Chapter 5 Busses, Ports and Connecting Peripherals

Artikel-Detailinformationen

Views. Specifications

WAVE-574 Hardware Specifications

Specifications for the Gateway M1300 Tablet PC

Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server

Phone and Fax: (717) or Send to- On the Internet at

HQP-1072 Series System User Guide


COMPUTING INDUSTRIAL EMBEDDED RUGEDIZED 19 INDUSTRIE PC

Data Sheet FUJITSU Server PRIMERGY TX100 S3p Tower Server

LaCie 12big Rack Network

Features Rich Expansion. Specifications Dimensions Optional Kit. Packing List Ordering Information Optional Modules

ABB RTU560A Series CMU & Modules

Foxboro Evo Process Automation System

Data Sheet. CELSIUS W370 E80+ Your gateway to workstation power

Terms of Reference Microsoft Exchange and Domain Controller/ AD implementation

Light Industrial Panel PC

7 x USB x 5V PoweredUSB on the rear panel. 2 x USB on the rear panel 2 x 5V PoweredUSB on the bottom panel

Artikel-Detailinformationen

NEC Express5800/T110f-E System Configuration Guide

QuickSpecs. HP Integrity cx2620 Server. Overview

Environmental data Temperature: -20 C to +55 C (Operating) -55 C to +85 C (Storage) Humidity: 0 95%

Rack mounted telephone- and leased line modem for industrial applications

Product Specifications. Shuttle Barebone D10. Shuttle Mini-PC with 7" Touchscreen. Feature Highlight.

QuickSpecs. Models HP Server Console Switches

firemon Powering Proactive Security Appliance Features: Meet the Family Quick initial setup Hardened O/S

Cisco MCS 7845-I2 Unified Communications Manager Appliance

FOR IMMEDIATE RELEASE

HP Server Console Switch with Virtual Media Overview

NGSS Data Consolidator (DC)

Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000

ORACLE EXALYTICS IN-MEMORY MACHINE X3-4

Data Sheet FUJITSU Server PRIMERGY TX1310 M1 Tower Server

QUESTIONS & ANSWERS. ItB tender 72-09: IT Equipment. Elections Project

SAN TECHNICAL - DETAILS/ SPECIFICATIONS

Views. Specifications

Data Sheet ESPRIMO P3510. Your flexible economic PC ESPRIMO P3510

EVGA Z97 Classified Specs and Initial Installation (Part 1)

SUN FIRE X4170 SERVER

Ultra Thin Client TC-401 TC-402. Users s Guide

Part-1: SERVER AND PC

North America, Inc. AFFICHER. a true cloud digital signage system. Copyright PDC Co.,Ltd. All Rights Reserved.

Data Sheet. CELSIUS W370 E80+ Your gateway to workstation power

Be ready for emergencies

DS-9500NI-ST Series NVR. Technical Specification

Matrox 4Sight GP. Industrial imaging computer with desktop-level performance and expansion. The right fit for machine vision or medical imaging

Executive Series. Intel Desktop Board DB75EN Executive Series MicroATX Form Factor

Transcription:

8 58 PLD.TOWER PLD.RACK VISONIK DCS Data and communication server PLD.TOWER PLD.RACK Data and communication servers (DCS) are used as management stations in building automation and control (BAC). With DDC technology, the DCSs, as superposed system components, allow for customer-specific solutions of all building automation and control tasks. Use The DCS' application range comprises a large number of building automation and control tasks such as: Process station communication at the subsystem level. Processing of acquired process data in real time. Continuous storage of selected process values (temperatures, setpoints, etc.). Monitoring of technical installations. Output of higher commands (e.g. peak load control, emergency power and network restoration). Logging of plant faults. Alarming of internal and external service organizations. Sending clear text messages based on technical plant events. Triggering reactions based on various causes: Time, date, process value changes and operating hours (maintenance). Simultaneous execution of various BAC tasks (multitasking). CMN858en 05.03.00 Building Technologies

Presentation of process values, consumption variables, efficiency degrees and further operational and technical system information in transparent displays. Operation of system-wide BAC functions via graphical user interfaces. Connection of linked and third-party systems. Operation of building automation and control systems via networks. Type summary The PLD-series of the DCS data and communication server consists of two housing types with scalable software licenses and hardware options. Tower housing: 9 rack housing: PLD.TOWER PLD.RACK DCS for 0 00 subsystems Option : Number of subsystems 0, 5, 5, 50, 75, 00, 50, 00 Option : VISONIK Version V Option : R-server redundant server operation System configuration Example for a VISONIK system configuration: Printer Insight Printer Printer System link via SDLC Ring, V. port or network Operating Level (Management Level Network) DCS PLD... BPS Building Level Network (SDLC) BPS BPS PVS PRV CFE TEC controllers Floor level Network (FLN) Link to foreign system NetBPS EcuBPS PRV BPS CFE / Siemens DCS Data and communication server PLD.TOWER / RACK CMN858en Building Technologies 05.03.00

Basic hardware The data and communication server is delivered with the following hardware components: We reserve the right to make changes to the basic hardware configuration. Required number of server types PLD... Basic PC Caution: The computers are delivered without keyboard and monitor! Tower Rack Order number Housing tower PLD.TOWER Housing rack PLD.RACK Mouse CPU hard drive supporting - mouse - keyboard - LAN, x RJ5 - COM serial RS-3-C (9-pin) - 0 USB interfaces (3 x front, x back, 3 x internal) - RAID5/ controller for SAS base units - I/O slots PCI-Express x - I/O slot PCI-Express x - I/O slots PCI-Express x8 - I/O slot PCI 3-bit / 33MHz, x long, 5V - SATA controller ( ports used for accessible drives) - VGA graphics (5-pin) Intel XENON processor X350 / memory. GHz Quad Core / GB DDR3 PC-M multifunction card with: - Watchdog - Radio clock - Auto reset WD - Front control panel including cable set Network card on main disk Storage media: DVD-RW 5.5 Hot plug hard drive SAS GB.5 ALD.F Basic software The data and communication server is delivered with the following preinstalled software: Server type PLD. Tower Rack Microsoft Windows Server 008 3 Bit VISONIK software (functionality according to version and computer type) VISONIK DCS license for 0 process stations VT00 emulator to connect terminals in a window to $T Siemens DCS Data and communication server PLD.TOWER / RACK CMN858en Building Technologies 05.03.00 3/

Options The following software and hardware components can be installed in addition to the basic installation. We reserve the right to make changes to the basic hardware configuration. Possible number for server types PLD... Tower Rack Order number PCIe- graphics card, 5 MB for higher performance PCI analog modem with USB interface PCI ISDN modem with USB unterface PCI audio card PLD.G5/E ALD.ANALOG ALD.ISDN ALD.AUDIO Uninterrupted power supply (UPS) APC SU-000 Redundant power supply ALD.USV ALD.RPS Equipment for connection of BLNs. SDLC/FSK kit to operate SDLC rings incl.: - PC-S express card - Connection cable to SDLC plug panel - SDLC plug panel x5 D-sub ALD.S/KIT Equipment for additional interfaces: Terminal server ( x V. interfaces), incl. - power supply (30 VAC / VDC) - adapter cables CBL-RJ5M9-50. Terminal server ( x V. interfaces), incl. - power supply (30 VAC / VDC) Terminal server (8 x V. interfaces), incl. - mains cable (30 VAC) - adapter cables.5m, type CBL-RJ5M5-50 - adapter cables.5m, type CBL-RJ5M9-50 - RJ5 loopback test plug - mounting brackets for 9 - rubber bases Terminal server ( x V. interfaces), incl. - mains cable (30 VAC) - 8 adapter cables.5m, type CBL-RJ5M5-50 - 8 adapter cables.5m, type CBL-RJ5M9-50. - RJ5 loopback test plug - mounting brackets for 9 - rubber bases ALD.TS ALD.TS ALD.TS8 ALD.TS Storage media: RDX drive 80-0 GB for upgrades and data backup, incl. - RDX cartridge 0/30 GB DAT drive DDS-5 incl. - mounting kit - 3 tapes ALD.RDX ALD.DAT Hot plug hard drive GB SAS for expansion to RAID Hot plug hard drive GB SAS for expansion to RAID5 3 3 ALD.F ALD.F / Siemens DCS Data and communication server PLD.TOWER / RACK CMN858en Building Technologies 05.03.00

Computer performance characteristics Below is a list of performance features not readily apparent from the list of components and accessories above. Furthermore, a few important VISONIK system variables are listed. Options are printed in parentheses. Server types PLD... Tower Rack Basic feature: Upgradeability to higher PLD types and options Yes Yes Watchdog, reset, radio clock, control panel Yes Yes RAID or 5 (redundant array of independent disks) Yes Yes Interfaces: Serial interfaces - Terminal server x V. interfaces (RS3) - Terminal server x V. interfaces (RS3) - Terminal server 8 x V. interfaces (RS3) - Terminal server x V. interfaces (RS3) Standard 0 8 0 8 Operation: Total number of terminals, printers and modems Standard Maximum* (5) (5) Maximum number of dial modems Operating system languages (3) (3) Number of access levels 5 5 Maximum number of concurrent users 5 5 System variables: Maximum number of connections for SDLC rings Maximum number of process stations 00 00 (EKL-X, PRV, PRV, BPS, CFE ) on BLN (SDLC, Ethernet) or via modem Addressing (alphanumeric user address), number of characters Linked system: Number of VISONIK computers within linked system 0 0 Alarm printer for messages from various systems possible in each system Yes Yes Security VISONIK computer as R-server; redundant operation of VISONIK server possible as an option via network. Yes Yes *) The maximum number of 5 messaging channels or 8 terminal channels respectively per DCS cannot be exceeded. The indicated standard characters represent a recommendation. We reserve the right to make changes to the computer configuration. Documentation See the following data sheets for information on VISONIK subsystems: BPS process station Building process station BPS/NetBPS EcuBPS CMN830 CMN830 CMN8307 Siemens DCS Data and communication server PLD.TOWER / RACK CMN858en Building Technologies 05.03.00 5/

Technical data If not mentioned specifically, the following information applies to all computer types. Power supply Mains supply PLD.TOWER and PLD.RACK Mains frequency 00-0 V 50-0 Hz Dimensions Max. rated current: PLD.TOWER and PLD.0.RACK Active power W x D x H PLD.TOWER PLD.RACK PLD.RACK (installation depth) 00 V 0 V / A 3 A 58 W 05 x 58 x mm 8 x 570 x 0 mm 5 height units (U) Weight PLD.TOWER and PLD.RACK ca. 8 Kg (depending on configuration). Ambient conditions Operating temperature 0-35 C BLN data transmission System bus protocol SDLC/FSK V. data transmission Transmission rates for terminals, INSIGHT, printers and modems As per the specifications Network data transmission Europe conformity CE label according to EU directivies Global Transmission protocol Networks Rate of transmission EMC directive Low voltage guideline TCP/IP, NetBIOS via TCP/IP Ethernet 0/00/000 Mbps 00/08/EC 00/95/EC EN 30038, EN 5037, EN55 0, EN 550, EN 0950-, EN 000-3-, EN 000-3-3 CB, RoHS, WEE / 00 Siemens Switzerland Ltd Subject to change Siemens DCS Data and communication server PLD.TOWER / RACK CMN858en Building Technologies 05.03.00