CAPACITIVE LEVEL METERS CLM 36



Similar documents
Technical Data. Dimensions

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Inductive sensor NI10-M18-Y1X-H1141

Relative pressure transmitter type 520

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Compact pressure switch Flameproof enclosure Ex d Model PCA

HERZ-Thermal Actuators

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Conductive Level Switch FK 2 Technical Data:

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

How To Use A Flowmeter

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Cable Plug acc. to DIN EN , Form A

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Plastic tube flowmeters Series PT/PS

Safety instructions VEGADIS DIS81.CEIA/V****

SEISMIC VELOCITY TRANSDUCER T1-40

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Digital inductive conductivity transmitter

Series 8146/5-V37 and Series 8150/5-V37

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Pressure transmitter For general industrial applications Model A-10

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

3/2-way Solenoid Valve, direct-acting, NC or NO

Differential-Hall-Effect based Sensors Series A5S

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Flow switches Series AD/VH

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Solenoid valves 2/2-way direct-operated Type EV210A

SITRANS F flowmeters SITRANS F M

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Assisted lift operated 2/2-way solenoid valves Type EV250B

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

4 Posiflow Proportional Solenoid Valves

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

Floodlight Range Installation Guide

Electronic Pressure Switch EDS 3000

Electronic Pressure Switch EDS 300

Technical data sheet TDS0070

Explosion proof enclosures

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

INSTALLATION AND OPERATING INSTRUCTIONS LEVEL SENSOR

Safety at a high level!

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Digital display DA 48

Contents. Document information

2.12. page Products for Explosion hazardous Environment

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

Instruction Manual. T3111 T3111L T3111P T3111Ex

Operating Instructions

Relative and absolute pressure switch type 529

Reaction Torque Sensor

Fluxi 2000/TZ Turbine Gas Meter

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

UM-X Field display for continous level sensors

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Duct Humidity Transmitter

Capacitive Prox E2K-X

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

7 Lighting Technology

Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve

Pluggable interface relays CR-P Pcb relays

Terminal Boxes Series 8146

Transcription:

CAPACITIVE LEVEL METERS CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and quick connecting by connector Continuous adjustment of initial capacity Version for usage in explosive areas, high temperature performance Current (4 20 ma) or voltage (0 10 V) output Capacitive level meters CLM are designed for continuous level measurement of liquids, powders and bulk-solid materials in vessels, tanks, sumps, containers, silos, etc. CLM consists of the stainless steel housing with electronic module and the measuring electrode. Type of measuring electrode is defi ned by kind of use and type of measured media. Sensitivity (SPAN) and initial capacity compensation (ZERO) can be fl uently set. CLMs are offered in version (N) for non-hazardous environments or (Xi) version to explosive areas up to zone 0 or zone 20, high temperature performance and several types of process coupling are also available. FEATURES OF VARIANTS CLM 36_ 10 CLM 36_ 12 CLM 36_ 20 CLM 36_ 22 CLM 36_ 30 CLM 36_ 31 CLM 36_ 32 CLM 36_ 40 With uncoated rod electrode for level measurement of non-conductive liquids (oils, diesel, petrol) and powder or bulk-solid materials (fl our, sand, cement, plastic granulates, etc.). Max. length 5 m. With fully (FEP) coated rod electrode for level measurement of water and conductive liquids incl. wasted liquids in metallic vessels, concrete sumps, reservoirs, etc., better behaviour against aggressive media, lower adhesion to some complicated media, chemical resistance. Max. length 3 m. With uncoated rod electrode and reference tube for accurate level measurement of clean nonconductive liquids (oils, diesel, petrol). By means of reference tube the output signal does not depend on the dimensions and shapes of a vessel. Max. length 3 m. With fully FEP coated rod electrode and reference tube for accurate level measurement of conductive liquids. Main use is for measurement in plastic vessels or tanks. Impossible to use for waste and high viscosity liquids and bulk-solid materials. Max. length 3 m. With uncoated stainless steel rope electrode and uncoated weight for level measurement of bulk-solid materials (grains, sand, fl our, cement, etc.). Max. length 20 m. With uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos. Max. length 20 m. With fully coated rope electrode and coated weight (rope insulation FEP, weight insulation PTFE), for level measurement of electrically conductive and non-conductive liquids. Max. length 20 m. With two coated electrodes (rode insulation FEP, head fully PTFE), for level measurement of aggressive liquids. Performance for non-explosive areas only. Max. length 2 m. CLM-dat-1.7

DIMENSION DRAWINGS Version with rod electrode CLM 36_ 10 CLM 36_ 12 Version with rod electrode and reference tube CLM 36_ 20 CLM 36_ 22 Z* - var. M - metric thread M-36x2 - var. G - thread G1 Version with rope electrode CLM 36_ 30 CLM 36_ 32 connector high temperature performance CLM 36_T acc. to concrete version Version with two coated electrodes CLM 36N 40 G housing with electronic module anchor with spherical joint high temperature segment steel anchor bushing or dusttight bushing wall of container spring reference tube weight rope electrode weight rope electrode var. M, G - housing with threads var. Cl - housing with Triclamp coupling CLM-dat-2.7 Version with rope electrode with anchor CLM 36_ 31 CLM-dat-2.7

TECHNICAL SPECIFICATION Supply voltage: CLM 36N(T) _ I CLM 36N(T) _ U CLM 36Xi(T) _ I 9... 36 V DC 16... 36 V DC 9... 30 V DC Current output Voltage output 4... 20 ma 0... 10 V Max. internal values of Xi version Ui = 30 V DC; Ii = 132 ma; Pi = 0.99 W; Ci = 370nF; Li = 0.9mH Sensitivity ranges 20 ; 30 ; 50 ; 100 ; 150 ; 300 ; 500 ; 1000 pf Initial capacity regulation ratio min. 1:2 Nolinearity max. 1 % Temperature error max. 0.05% / K Voltage error for current and voltage output max. 0.3 μa/v a 0,1 mv/v Internal resistance / electric strength (electrode - housing) 1 MΩ / 250 V AC Coupling capacity / electric strength (housing - supply leads) var. N : 51 nf / 250 V AC var. Xi : 26 nf / 500 V AC Allowed temperature range in zone 0, var. Xi (EN 50284) -20... +60 C Allowed pressure range in zone 0, var. Xi (EN 50284) 0.8... 1.1 bar (0.08 to 0.11 MPa) Protection class: - Housing - Connector GDM 2009 (current output), GDM 3009 (voltage output) - Connector GAN-DADE 7A (current output), GAN-DAEE 7A (voltage output) IP67 IP65 (standard) IP67 (optional) Max. load (serial) resistance for current output (U = 24 V) R max = 750 Ω Max. load current of voltage output R min > 1 kω Weight of the housing: ca. 0.5 kg Weight of high temperature performance NT, XiT: ca. 1 kg TEMPERATURE AND PRESSURE DURABILITY Variants / Performance Operation temp. range (on electrode) Ambient temperature range t a on housing Version N Version Xi Max. operation press. for t a = - 40... +20 C Max. oper. press. for t a = - 40... +85 C CLM 36_ 10, 20-40... +200 C - 40... +85 C - 40... +75 C 3 MPa 1 MPa CLM 36_ 12, 22-40... +120 C - 40... +85 C - 40... +75 C 3 MPa 1 MPa CLM 36_ 30-40... +200 C - 40... +85 C - 40... +75 C 1 MPa 0.5 MPa CLM 36_ 31, 32-40... +120 C - 40... +85 C - 40... +75 C 1 MPa 0.5 MPa CLM 36_ 40-40... +120 C - 40... +85 C 0.1 MPa 0.1 MPa MAXIMUM OPERATIONAL TEMPERATURE FOR HIGH TEMPERATURE PERFORMANCE Temperature in coupling place 100 C 120 C 150 C 180 C Max. pressure 3.0 MPa 2.0 MPa 1.5 MPa 0.5 MPa USED MATERIALS Part of the CLM Variants Standard material Optional (on request) St. Steel W. Nr. 1.4571 (AISI 316 Ti) All types, except CLM 36_ 40 St. Steel W. Nr. 1.4301 (AISI 304) Housing St. Steel W. Nr. 2.4858 (Incoloy 825) CLM 36_ 40 PTFE Insulating bushing All types, except CLM 36_ 40 PTFE CLM 36_ 10, 12, 20, 22, 40 St. Steel W. Nr. 1.4301 (AISI 304) St. Steel W. Nr. 1.4571 (AISI 316 Ti) Electrode CLM 36_ 30, 31 St. Steel W. Nr. 1.4404 (AISI 316 L) CLM 36_ 32 Zinc Steel rope Electrode coating CLM 36_ 12, 22, 32, 40 FEP CLM 36_ 31 Polyolefi n (modifed PE) PTFE Weight insulation CLM 36_ 32 PTFE Weight / Anchor mechanism CLM 36_ 30, 31, 32 St. Steel W. Nr. 1.4301 (AISI 304) Reference tube CLM 36_ 20, 22 St. Steel W. Nr. 1.4301 (AISI 304) St. Steel W. Nr. 1.4571 (AISI 316 Ti) CLM-dat-3.7

WORKING AREAS (acc. to EN 60079-14 and EN 50281-1-2) CLM 36N Performance for non-explosive areas CLM 36NT High temperature performance, for max. temperatures in coupling place 200 C Performance for explosive areas (combustible dusts, gases or vapours) CLM 36Xi II 1 GD T 83 C Ex ia IIB T5 with isolating repeater (e.g. IRU-420) Whole CLM in zone 0 and 20 High temperature performance (max. 200 C) for explosive areas CLM 36XiT II 1/2 GD T 83 C Ex ia IIB T5 isolating repeater (e.g. IRU-420) Electrode part zone 0 and 20, housing zone 1 and 21 PROCESS CONNECTION CLM 36 M _ Thread process coupling M36x2 CLM 36 G _ Thread process coupling G1" (CLM 36_ 40: G1½") CLM 36 Cl _ Sanitary Triclamp process coupling INSTALLATION Level meters are designed to mounting in vertical position on the top lid of a tank or a container by means of welding fl anges, stainless steel fixing nuts or Triclamp coupling. When installed into metallic wall vessel it is not necessary to ground the housing of CLM. In the case of use in concrete basins or silos it is recommended to install the CLM on metallic bracket or auxiliary metallic construction electrically connected with the liquid (water), or connected with metallic armour of silo. In the case of measuring in glass or plastic vessels by CLM without the reference tube (electrode) it is necessary to build up an auxiliary electrode (metallic tape) on outer wall of a vessel and connect it with CLM housing (by screw located on the housing). Material of auxiliary electrode is necessary to choose in accordiance with working environment or character of measured material. Orientation dimension drawings for mounting you can see below. INFLUENCE OF THE TANK SHAPE TO LINEARITY OF MEASURED CAPACITY In curved tanks (most frequently horizontal cylinder) capacity change during measurement of electrically non-conductive material is nonlinear. Linearity is done by the use of reference tube (CLM 36_ 20, 22). Linearization can be done also by reference electrode (CLM 36_ 40). In the tank with straight wall and with the sensor placed parallel with the wall is the capacity change linear For sensors with two electrodes in the tank with straight wall is the capacity change linear (CLM 36 40 _ _). CLM-dat-4.7

MOUNTING RECOMMENDATION CLM 36_ 10, 12 Installation in metallic or Non-metallic vessels CLM 36_ 20, 22 Variants with Ref. tube Auxiliary electrode Width = min.30mm (necessary only for Non-metalic vessels) E - The length of electrode - the lower end of the electrode has to be dipped min. 20 mm below the lowest measured level h - The distance from the bottom - min. 50 mm a - The distance from the wall - min. ca. E/20 d - The diameter of auxiliary tube vessel - min. 40 + E/20 h - The distance from the bottom - min. 50 mm - The distance from the wall - arbitrary CLM 36_ 31 Installation of rope electrode with anchor CLM 36_ 30 CLM 36_ 32 Installation in containers and silos Installation in deep vessels and sumps E - The length of electrode - the lower end of the electrode has to be dipped - min. 20 mm below the lowest measured level h - The distance from the bottom - min. 100 mm a - The distance from the wall - approx. the same as the distance from the inlet E - The length of electrode c - The distance from the axis of the silo (has to be minimised) - The length of the conduction rod ca. 500 mm - The length of the press spring ca. 200 mm - Steel anchor welding cylinder or dust-tight bushing (to be welded into the conical bottom wall) CLM 36_ 40 Non-metallic vessels and aggressive liquids E - the length of electrodes - the lower end of the electrodes have to be dipped min. 20 mm below the lowest measured level h - the distance from the bottom - min. 30 mm a - the distance from the wall - min. cca E/20 CLM-dat-5.7

ELECTRICAL CONNECTION The CLM is designed to be connected to supply unit or to controller through cable with outer diameter 6 to 8 mm (recommended cross section of cores 0.5 to 0.75 mm 2 ) by means of connector which is included in delivery. The scheme and the inside of the connector are on pictures. Shielded cable is necessary to use when the cable length is over 30 m. Connect shielding to the socket to the power panel. +U (Brown) Shielding (Green-Yellow) Uout (Black) shielding do not con nect +U (Brown) Shielding (Green-Yellow) 0V (Blue) 0V (Blue) Connection scheme and inside of the connector socket ADJUSTMENT ELEMENTS The adjustment of level meter is by DIP switches and two trimmers 4 ma and 20 ma (to set min. and max. level). These adjustment elements are placed under outlet nut of level meter. For detailed information please read at the instructions. Green-yellow wire (shielding) Blue wire (-) Brown wire (+) Green-yellow wire (shielding) Black wire (Uout) Blue wire (-) Brown wire (+) Trimmer 4 ma (Zero) Trimmer 20 ma (Span) Trimmer 0 V (Zero) Trimmer 10 V (Span) DIP switches (For range select) 0V 10V DIP switches (For range select) Brass tie (For pull out of electronic module) Brass tie (For pull out of electronic module) The top view on the internal electronic module for current output (var. I) The top view on the internal electronic module for voltage output (var. U) ORDER CODE CLM 36 E Performance: N - Normal - for non-explosive areas Xi - Explosion proof - intrinsically safe for hazardous (explosive) areas, only with "I" output (except CLM 36_ 40) NT, XiT - High temperature performance Length of electrode in mm Type of output: I - Current (4 20 ma), U - Voltage (0 10 V) Process connection: M - Thread M36x2, Cl - Triclamp G - Thread G1", G - Thread G1½" for CLM 36N 40 Electrode performance: 10 - Rod, uncoated 12 - Rod, FEP coated 20 - Rod, uncoated, with reference tube 22 - Rod, FEP coated, with reference tube 30 - Rope with uncoated weight 31 - Rope with uncoated weight and anchor 32 - FEP coated rope, PTFE coated weight 40 - Two rods, FEP coated CORRECT SPECIFICATION EXAMPLES CLM 36N 10 G I E1100 CLM 36NT 12 M I E1500 CLM 36N 32 G U E6000 CLM 36Xi 20 M I E900 CLM 36Xi 30 M I E12000 CLM 36N 12 Cl I E2000 CLM-dat-6.7

ACCESSORIES Standard included in the level meter price 1x of seal, other seals are on request (PTFE, Al, etc.) 1x connector socket 1x screwdriver for adjustment (each 5 pcs) Distance element for rods longer than 50 cm (for CLM 36_ 40) Optional (see datasheets "Accessories") Connector with protection class IP67 (GAN DADE 7A) with 5 m cable (current output) Connector with protection class IP67 (GAN DAAE 7A) with 5 m cable (voltage output) Steel welding fl ange ON 36x2 Stainless steel welding fl ange NN 36x2 Stainless steel fi xing nut UM 36x2 SAFETY, PROTECTIONS, COMPATIBILITY AND EXPLOSION PROOF Level meter CLM 36 is equipped with protection against electric shock on electrode, reverse polarity, output current overload, short circuit and short time over voltages. Electromagnetic compatibility is provided by conformity with standards: EN 55022/B, EN 61326-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6. Explosion proof of CLM 36Xi is examined by FTZÚ-AO 210 Ostrava - Radvanice certifi cate No.: FTZÚ 02 ATEX 0235X. version 04/2009 CLM a Dinel are registered trademark of company Dinel s.r.o. Dinel, s.r.o. U Tescomy 249 760 01 Zlín, Czech Republic CLM-dat-7.7 Phone: Fax: +420 577 002 003 +420 577 002 007 sale@dinel.cz www.dinel.cz