OPHTHALMIC EQUIPMENT YOU WILL MEASURE OUR DIFFERENCE. www.essilor.ca



Similar documents
Phoroptor VRx Digital Refraction System

CR-2 AF and CR-2 PLUS AF Non-Mydriatic cameras. Designed for the highest possible image quality. See the smallest details, don t miss pathology.

HRK-7000 / HRK-7000A Auto Ref-Keratometer

SLIT LAMP BQ 900 Sophisticated microscopy

SCHWIND CAM Perfect Planning wide range of applications

Product Range Overview

DISTANCE LEARNING COURSE. Anatomy of the Patient Exam , BSM Consulting All rights reserved.

Smallest design. Biggest impression. Impressively thin. Retractability. See more of your patient. See more patients. Thinnest Phoroptor yet.

ALL-IN-ONE Optical Biometry, Dual Scheimpflug Tomography and Placido Topography

ABrand New Refraction Meas urement Instrument

Vision Glossary of Terms

LOUPES AND HEADLIGHTS HEADLIGHTS. HEINE Headlights. Type of Light LED LED F.O. Light Intensity (at 250 mm working distance)

Trends in Ophthalmology a Market Perspective. Matthias Karl, Michael Kempe

Essential Line from ZEISS Simplicity in basic diagnostics NEW

Ultimate ease of use, menuless with large icons Easy output to , print or file

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

Smart Refractor RT-3100

Customized corneal ablation and super vision. Customized Corneal Ablation and Super Vision

TAGARNO AS Sandøvej Horsens Denmark Tel: Mail: mail@tagarno.com

Inspection and Illumination Systems for Visual Quality Assurance. Large selection Attractive prices Tailored solutions. optometron.

microscope OP-Dent-5

Contents. Introduction 2. Features and Benefits 3. Freeform Design Range 10. Custom 14/16/ Custom U 15. Custom V 17.

The best lab standard. 1,4 Megapixels 2/3 inch sensor Giant pixel size 6 times optical zoom Massive 16-bit imaging for enhanced dynamic

SCHOOL ACCREDITATION DOCUMENT

Three pearls in one shell. Heidelberg Retina Tomograph

MODERN CLINICAL OPTOMETRY BILLING & CODING THE MEDICAL EYE EXAMINATION. Definitions of Eye Examinations. Federal Government Definition

M.OPTOM. FIRST YEAR. Subject Code 101 Part 1. VISUAL AND CLINICAL OPTICS

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Fundus Photograph Reading Center

M A R C O. CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual

CHEMALUX 100OD SYSTEM. CHEMAT VISION - partner in vision care

Welcome to the Verisyse Seminar

LOCSU Enhanced Services

LASER VISION CORRECTION: WHAT YOU SHOULD KNOW.

Cataract Testing. What a Patient undergoes prior to surgery

ReLEx smile Minimally invasive vision correction Information for patients

OCULUS PENTACAM BASIC CLASSIC HR

MAke A difference in someone s life

How To Use Trackeye

// SUPER technology for precise web viewing: SUPER HANDYScan Be inspired. Move forward.

The Eye Care Center of New Jersey 108 Broughton Avenue Bloomfield, NJ 07003

Advanced Eyecare of Orange County Kim Doan, M.D. Eye Physician & Surgeon

2WIN Binocular Mobile Refractometer and Vision Analyzer

Informed Consent For Cataract Surgery And/Or Implantation of an Intraocular Lens

IMAGE ASSISTANT: OPHTHALMOLOGY

A new advance in routine inspections INVERTED MICROSCOPE CKX41/CKX31

Flat-Field IR Mega-Pixel Lens

Alexandria s Guide to LASIK

Design your own vision

Advanced Ortho-K Technology. Proudly brought to you by. Australian Contact Lenses

AUTO PHOROPTOR. Auto Refraction System. User s Guide

Administrative Code. Title 23: Medicaid Part 217 Vision Services

CORNEAL TOPOGRAPHY. Refractive power of the eye

Schedule of Benefits. for Optometry Services (April 1, 2009) Ministry of Health and Long-Term Care

Page: 1 of 6. Corneal Topography/Computer-Assisted Corneal Topography/ Photokeratoscopy

Excimer Laser Refractive Surgery

Rediscover quality of life thanks to vision correction with technology from Carl Zeiss. Patient Information

Marco Products. When Seymour Marco, OD founded the. Manual & Digital Refractors. Xfraction sm. Refractive Workstations. Lensmeters

Your one stop vision centre Our ophthalmic centre offers comprehensive eye management, which includes medical,

INFORMED CONSENT FOR PHOTOREFRACTIVE KERATECTOMY (PRK)

I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit

Application Report: Running µshape TM on a VF-20 Interferometer

Informed Consent for Cataract Surgery and/or Implantation of an Intraocular Lens (IOL)

Rodenstock Photo Optics

NEW HORIZONS IN CORNEAL SURGERY VERSATILE FEMTOSECOND LASER WORKSTATION WE FOCUS ON PERFECTION

AcrySof IQ Toric IOL (SN6ATT) Surgeon Keys for Success & Acknowledgement

Detachable DIY Door Viewer Camera for Home / Office Safety. Installation Manual. (* This is a patented product, do not copy) IA Technologies Inc.

TRUMPF I iled The new era of LED surgical lights

THE EYES IN MARFAN SYNDROME

VarioCAM high resolution

Consumer s Guide to LASIK

Dinion XF the high-performance, smart surveillance camera. Dinion XF the flagship of the Dinion family

LASIK & Refractive Surgery

Case Report: Fitting of a Mini-Scleral Lens on a Post-RK and Post-LASIK Irregular Cornea

Our Commitment To You

Visual Acuity, Impairments and Vision Insurance Plan Provisions. Stuart West Specialty Sales Manager Virginia CE Forum 2009 Course #

femtosecond laser platform Exceptional versatility without compromise

Seeing Beyond the Symptoms

// ipq-view Digital web viewing for your quality assurance. Be inspired. Move forward.

How To Use The Dc350 Document Camera

Make a difference in someone s life FITTING GUIDE

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Care and Use of the Compound Microscope

9.7" Microscope Tablet Camera (REALPAD 5.5) Introduction. Feature

Servo/Hydraulic Press Brake. HG Series HG 5020, HG 8025, HG 1303, HG 1703 HG 1704, HG 2203, HG 2204

Capacities Overview: 9.7 MultiTouch Screen with IPS technology Access to AndroidTM apps HD Multimedia playback

OMNI EYE SPECIALISTS. The Intraocular Lens

DCN Next Generation The next step in digital congress management

SNC-VL10P Video Network Camera

EyeMag Medical Loupes from ZEISS Seeing is believing NEW! LED illumination

GENERAL CODING INFORMATION. Use of Modifiers for Identifying Specific Eye

One Focus: Ophthalmology

Keratoconus Detection Using Corneal Topography

ZEISS Compact Prime and Zoom lenses Flexibility and performance in a winning combination.

Ophthalmic Equipment Guide

Pediatric and Binocular Vision Examination and Billing Protocols

Optical Digitizing by ATOS for Press Parts and Tools

Refractive errors are caused by an imperfectly shaped eyeball, cornea or lens, and are of three basic types:

Transcription:

OPHTHALMIC EQUIPMENT YOU WILL MEASURE OUR DIFFERENCE www.essilor.ca

Essilor the world leader in corrective lenses owes its success to its strategy which has been driven by innovation for over 160 years. Its objective is to enable everyone to have lenses suited to their needs. With you, the Essilor Instruments Division is helping the Group achieve this goal. This entity, which is a leader in edging solutions, offers you dedicated solutions to optimise your sales outlet. Today, Essilor Instruments has decided to renew its optometry range, to further assist you in the daily performance of your work. This purposely broad, high-quality range will meet all your needs in terms of refraction, contact lens adaptation, eye disease screening and diagnosis. It is completed by a range of services which includes training, image analysis software & data transfer.

4 r easons for choosing ESSILOR 1 Quality and performance 2 Variety and modularity 3 Comfort and connectivity 4 Service and training Products which A flexible range which Products offering a wide A comprehensive range performances turn each adapts to different range of connections of services to take vision test into a requirements depending and software to full advantage of high quality service. on practices and optimise the entire the potential of each available space. refraction and test instrument. chain. 3

An optimisation of the refraction chain and the management of customers data Objective refraction Visual exam Previous prescription Optotypes projection 4

C O N T E N T S 1 2 3 4 Subjective refraction Acuity measurement APH 500 MPH 100 Projection of optotypes CS pola 700 CS pola 600 CS 500 CS 100 Objective refraction, contactology & diagnosis AKR and tonometer AKR medica 500 AKR cornea 500 AKR 700 AKR 500 ATNC 500 Slit lamps SL 7 medica + Software Eye Capture Units & table Tables SL 5 cornea + SL 3 cornea DC 500 5

S u b j e c t i v e r e f r a c t i o n

Acuity measurement APH 500 - - - - - - - - 1.2 MPH 100 - - - - - - - - 1.4 Projection of optotypes CS pola 700 - - - - - - 1.5 A wide range to perform easy and accurate prescription checks and comprehensive optometric tests. For even greater speed and precision, Essilor products easily interconnect and enable you to customize test sequences according to your own practices. CS pola 600 - - - - - - 1.6 CS 500 - - - - - - - - - 1.7 CS 100 - - - - - - - - - 1.8 1

Light, compact design for perfect interaction with the customer. Extremely fluid refraction thanks to the high rotation speed of the lenses. Optimised management of near-vision test, for acuity measurement as well as final verification. Customer information and sales support functions. Fully interconnected system for an optimisation of the refraction chain. Leading-edge technology for vision professionals The APH 500 automatic refractor is a top-of-the-range instrument offering speed and comfort for all types of tests. With its control and interconnection possibilities, it is the ideal instrument for those who want to optimise the refraction chain. 1.2 e s s i l o r o p t o m E t r Y

EASE OF USE All prescription and optotype data managed in the twinkling of an eye. Assisted search for astigmatism and prisms, to perform thorough, customized tests in record time (patented technologies). Great ease of navigation and user comfort through the integrated help and recording of pre-programmed sequences. Compact design which gives an excellent perception of the patient s expressions. NEAR-VISION PERFORMANCE Tilting and convergence capacity promoting a natural reading position. Integrated LED lighting. Daily scen simulation and reading tests to check the final prescription (available on the KB 500). TWO CONTROL MODES Reception of objective refraction and lensmeter data. Simultaneous control of the refractor head and optotypes. APH 500 1 S u b j e c t i v e r e f r a c t i o n APH 500 with controller keyboard With its adjustable screen, the KB 500 offers mobility, user comfort and conviviality with the patient. In addition, its touchscreen interface offers unequalled handling and navigation comfort. APH 500 with PC Simple and economical, it allows the centralisation of all software on an existing PC. 1.3

1 S U B J E C T I V E R E F R A C T I O N MPH 100 AVAILABLE SOON refractions in far and near vision. Automatic convergence in intermediate and near vision. Rapid advance of lenses through a simple knob with automatic driving of the discs. Easy installation on self-balancing arm or on a wall-mounted arm. T H E BENCH M A R K M A N u A L R E F R A C T O R The MPH 100 manual refractor is a robust all-inclusive instrument for those who look 1.4 E S S I L O R O P T O M E T R Y

Excellent screen contrast and luminosity. Extensive choice of tests (contrasts, binocular vision ) and optotypes (Snellen, Landolt C, symbols for children, etc.), including ETDRS. Optotypes randomisation and reversible tests fo mirroded room. Possibility to project situation tests to ensure final prescription appropriation. Connection to the APH 500. CS pola 700 offers a circular polarisation technology allowing 100% image separation, without any parasite image. CS 500 features a version without polarisation. CS pola 700 1 S u b j e c t i v e r e f r a c t i o n high-definition screen to perform all tests in total comfort CS pola 700 The CS Pola 700 LCD screen is ideal fo those who want an optimised solution to work with the APH 500 automatic phoroptor. It is available in 2 versions: With circular polarisation (CS pola 700) or without polarisation (CS 500). e s s i l o r o p t o m e t r y 1.5

1 S u b j e c t i v e r e f r a c t i o n CS pola 600 Large choice of tests: binocular balance and fusion, aniseikonia, stereopsis, strabismus, phoria, color blindness, Amsler grid test, etc. Wide viewing angle to provide clear chart and remove image distortion. User convenience in dark rooms ensured thanks to remote control built-in LCD panel. Random function to avoid patient optotypes memorisation. Connection to the APH 500 for combined management of lenses and optotypes. Universal screen for all refraction rooms 8 The CS Pola 600 is a large lcd screen which adapts to all refraction rooms. Its design and ergonomics combined with its great possibilities of customisation, are highly appreciated by ECP s. 1.6 e s s i l o r o p t o m e t r y

1 S u b j e c t i v e r e f r a c t i o n CS 500 Excellent screen contrast and luminosity. Extensive choice of tests (contrasts, binocular vision ) and optotypes (Snellen, Landolt C, symbols for children, etc.), including ETdrs. Capacity to project images and videos. Daily scene simulation useful for checking the final prescription. Connection to the APH 500 for combined management of lenses and optotypes. Universal screen for all refraction rooms The CS 500 LCD optotype screen is ideal for those who want a screen with numerous testing and customization options. With its carefully studied design, it will fit into all refraction rooms. 1.7 e s s i l o r o p t o m e t r y

Large range of tests (Snellen, fixation point, binocular vision, stereoscopic, children s tests, etc.) 2 specific programmable test sequences. Large choice of options: telescopic lens, projection plate, wall-mounted arm. Connection to the APH 500 for combined management of lenses and optotypes. CS 100 1 S u b j e c t i v e r e f r a c t i o n The quick and EASy multi function projector The CS 100 is an optotype projector capable of displaying very sharp high-contrast images in a fluid way through the quick rotation of the tests. With its compact design and tilting system, it adapts to all refraction rooms. e s s i l o r o p t o m e t r y 1.8

Objective refrac t contactology & eye disease dia

AKR and tonometer tion, gnosis AKR medica 500 - - - 2.2 AKR cornea 500 - - - 2.4 AKR 700 - - - - - - - - 2.6 AKR 500 - - - - - - - - 2.8 ATNC 500 - - - - - - - 2.9 Slit lamps SL 7 medica + - - - - 2.10 SL 5 cornea + - - - - 2.11 This range offers numerous solutions in terms of objective refraction, contactology and eye disease diagnosis. SL 3 cornea - - - - - 2.12 DC 500 - - - - - - - - 2.13 Depending on practices and available space, you can choose the appropriate function level and be sure of reliable measurements, even in the most complex cases. 2

Fully automatic objective refraction, keratometry, tonometry and pachymetry. Calculation of intraocular pressure taking into account the thickness of the cornea. Rotary prism technology applied to objective refraction. Connection to the APH 500 for automatic transmission of objective refraction data. THE 4 - I N-1 U L T R A COM P A C T A ND U L T R A P RECISE S O L U T I O N The AKR Medica 500 is an auto-kerato-refractometer tonometer pachymeter with an ultra compact design combining 4 essential measurements to optimise the workspace and working time. 2.2 E S S I L O R O P T O M E T R Y

TIME & SPACE SAVER A comprehensive, easy-to-use 4-in-1 tool which performs all measurements in a totally automatic way. Compact design for optimal integration in all workspaces. Transfer of objective data to the APH 500 for easier subjective refraction COMFORT Large adjustable colour screen and original user interface simplifying the operating process. Patient stress is minimised, thanks to the tonometer regulated air flow. For complex cases, 2 complementary modes: manual and semi-automatic. Corneal Thickness (µm) (Compensated IOP) = (measured IOP) - (CCT-A) x B CCT : Central Corneal Thickness 600 550 500 450 400-2 -1 0 1 2 IOP Compensation (mm Hg) UNEQUALLED PRECISION Extremely precise objective data, even on small-diameter pupils and damaged retinas (rotary prism technology). More reliable tonometry tests through pachymetry. The intraocular pressure measurement is adjusted to take account of the thickness of the cornea (calculation rule based on several medical studies). AKR medica 500 2 Objective refraction, contactology & eye disease diagnosis 2.3

2 Objective refraction, contactology & eye disease diagnosis AKR cornea 500 Ideal synthesis of objective refraction and corneal topography The AKR Cornea 500 is an auto-kerato-refractometer-topographer which gives precise and reliable results. Easy to use, it is an ideal solution to optimise available space. High-precision objective refraction thanks to rotary prism technology. Screening for corneal problems (keratoconus, corneal degeneration, irregular astigmatism) or problems in adapting to special contact lenses (orthokeratology, gas-permeable contact lenses). Display and analysis of corneal topography with the Cornea Topographer software supplied (refer to Section 3). Connection to the APH 500 for automatic transmission of objective refraction data. 2.4 e s s i l o r o p t o m e t r y

TECHNOLOGICAL FOCUS ROTARY PRISM A TECHNOLOGy WHICH MAKES THE DIFFERENCE, EVEN IN THE MOST COMPLEx CASES The rotary prism method a unique technology used in all AKRs of this range ensures objective measurement reliability, precision and regularity. An original optical system: mesuring a wider area on the retina to ensure optimal results, even on small-diameter pupils. Rotary prism Mirror Measuring Ring AKR 700 Rotary Ring image Sensor AKR cornea 500 Patented technology. Extremely precise refraction and keratometry. Extended measurement capacity, covering pupils as small as 2 mm. Improved ease of measurement and reliability in cases of glaucoma, asymmetric pupils or age-related retinal pathologies. AKR 500 2.5

Great freedom of movement provided by the swivelling touch screen. Astonishing capacity to adapt to all environments. Rapid and reliable results in comfort. Fully automatic. Connection to the APH 500 for automatic transmission of objective refraction data. The ultimate comfort for users as well as patients The AKR 700 is a latest-generation auto-kerato-refractometer allowing high-quality measurement through its revolutionary ergonomic design and automatic operation. 2.6 e s s i l o r o p t o m e t r y

AUTOMATION A totally automatic process from alignment to printing. Automatic detection of abnormal measurement conditions. COMFORT & CONVENIENCE Easily fits into the smallest spaces, thanks to its swivelling touch screen. Interaction and closeness with the patients, notably elderly people and children. Chinrest with a 5 tilt for greater comfort. MEASUREMENT PRECISION Fast and precise measurement thanks to the rotary prism technology. Central and peripheral keratometry ensuring thorough evaluation of the cornea for adaptation of contact lenses. AKR 700 2 Objective refraction, contactology & eye disease diagnosis 2.7

2 Objective refraction, contactology & eye disease diagnosis AKR 500 High-precision objective refraction thanks to rotary prism technology. Compact optical head improving interaction with the patient and visibility of his position. Quick, easy and stress-free measurement, particularly in burst mode. Measurement of corneal diameter. Automatic transmission of objective refraction data to the APH 500. Ultra precision in total simplicity Quick, easy and ultra precise thanks to its rotary prism technology, the AKR 500 autokerato-refractometer is a must for all vision professionals. 2.8 e s s i l o r o p t o m e t r y

2 Easy to use. Auto-control function for easy maintenance. OBJECTIVE REFRACTION, CONTACTOLOGY & EYE DISEASE DIAGNOSIS ATNC 500 Totally automatic cycle: alignment, adjustment and measurement. Air puff regulated according to the amount GENTLE AND PRECISE TONOMETRY The ATNC 500 non-contact tonometer is a must for measuring intra-ocular pressure in glaucoma screening. Patient discomfort is minimised thanks to the use of a gentle, E S S I L O R O P T O M E T R Y 2.9

2 Objective refraction, contactology & eye disease diagnosis SL 7 medica + The high-end benchmark for all types of tests Yellow filter* Observation tube* Background lighting* Hruby lens* Excellent image and colour rendering thanks to its binocular convergence system. Possibility of examining all eye structures (cornea, retina, crystalline lens, etc.) thanks to its light tilting feature and numerous slit adjustments and light intensity settings. 5 magnification levels allowing comprehensive examination of the state of all anterior eye structures. Combined with the DC 500, possibility of capturing images and video sequences. 8 MP photo 1 MP video The SL7 medica + slit lamp is aimed at demanding professionals wishing to carry out complete eye examinations. With its wide range of filters, magnification capacities and Range of filters 13 % ir uv ha many options, it is the benchmark instrument in its field. Magnifications x6 x10 x16 x25 x40 2.10 e s s i l o r o p t o m e t r y

Yellow filter* Observation tube* Background lighting* Hruby lens* Excellent image and colour rendering thanks to its binocular convergence system. Increased quality of contrast with the amber filter, for optimal examination conditions. Accurate assessment of the state of the eye s anterior structures thanks to 5 magnification levels. Combined with the DC 500, possibility of capturing images and video sequences. 8 MP photo 1 MP video Versatility and performance in contactology SL 5 cornea + 2 Objective refraction, contactology & eye disease diagnosis Range of filters ir uv The SL5 cornea + slit lamp is a high-performance contactology equipment. With its 5 magnification levels, it is a versatile instrument suited to all tests. Magnifications x6 x10 x16 x25 x40 e s s i l o r o p t o m e t r y 2.11

2 Objective refraction, contactology & eye disease diagnosis SL 3 cornea Yellow filter* Fixation target* Hruby lens* Excellent optical quality for optimal examination conditions. 3 magnification levels for accurate examination of the anterior parts of the eye. Instant access to the different functions thanks to its compact, ergonomic design. Thanks to its LED technology, the light lasts 100 times longer than on conventional equipment. All the essentials in a compact version The SL3 cornea is the ideal compact slit lamp for those who want the essential eye examination functions in a small-size instrument. Range of filters ir Magnifications x10 x16 x25 uv 2.12 e s s i l o r o p t o m e t r y

Easy capture of images and videos thanks to a trigger on the joystick and multiple-shot mode. 8-million pixel CCD sensor for photos and resolution of 1 million pixels for videos. Plug and play installation. Comes with the Eye Capture software (refer to Section 3). DC 500 2 Objective refraction, contactology & eye disease diagnosis 8 MP photo 1 MP video High-performance digital imaging The discrete, high-performance DC 500 digital camera is easy to install and is totally compatible with the SL7 medica + and SL5 cornea + slit lamps. The high-resolution images can be saved. e s s i l o r o p t o m e t r y 2.13

S o f t w a r e

Image management and analysis Eye Capture - - - - - - 3.2 This software range offers solutions for digital image acquisition, analysis and archiving. 3

3 S o f t w a r e Eye Capture Automatic indexing of files by date, folder and/or patient name. First level of analysis thanks to the contrast adjustments and camera settings. Export of various digital file formats. Photo formats: JPEG, TIFF, PNG, BMP. Operating system: Microsoft Windows XP Pro, Windows 7 Pro. Software included with the DC 500. High-definition digital capture 8 MP photo 1 MP video In combination with the DC 500, the Eye Capture software generates digital photos and videos of the anterior parts of the eye. It allows to record them and provides a first level of analysis by adjusting the contrast and camera settings. 3.2 e s s i l o r o p t o m e t r y

R e f r a c t i o n f u r n i t u r e

tables - - - - - - - - - - 4.2 4

2-position footrest (centre and side). Elevation: 590 to 840 mm. Tabletop dimension: 700 x 450 mm. Auxiliary electric socket. 830 mm 520 mm Table 4 Refraction furniture A perfect solution to complete an installation This motorised side table is ideal to install any type of instrument and expand an optometry installation. e s s i l o r o p t o m e t r y 4.2

fixed side table 2 instruments - TAM 020 - translating side table 2 instruments - TAM 010-560 mm Tables 550 mm 4 Refraction furniture 1000 mm 1000 mm 4.3

Gloss ary SUBJECTIVE REFRACTION Connection with automatic phoroptor APH 500 OBJECTIVE REFRACTION, CONTACTOLOGY & DIAGNOSIS Data transfer to APH 500 Measurement Range - sphere and cylinder Measurement range - Prism Rotary prism technology Product functions: K: Keratometry R: Objective Refraction Tp: Topography Tn: Tonometry P: Pachymetry Cross Cylinder Regulated air puff Polarisation Video resolution Projection distance Photo resolution Screen size Software

As improvements are made, these specifications may be changed without prior notice. APH 500 PC: Computer, screen and keyboard are not provided by Essilor. *Available in option.

ESSILOR INTERNATIONAL - R.C.S. Créteil B712 049 618-12/2011 - PI002E - Hakuhodo France