water Treatment Industries Design, Manufacture & Distribution Of Sewage Treatment Systems For Domestic & Commercial



Similar documents
PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems

Aerated Wastewater T r eatment System

A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS

SEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE

ENVIRONMENTAL HEALTH FACT SHEET NO. 500

What Is An On-Lot Sewage Disposal System?

Looking after your Septic Tank System

Properly maintaining your septic system will help reduce the. It s Your Septic System. Homeowner s Guide. Here s How to Take Care of It

SEPTIC TANK SYSTEMS. Single purpose septic tank receives toilet wastes (blackwater) or sullage (greywater) only.

Research of Grey Water for Use in Residential Applications Original date of publication: Updated:

Approved Aerobic Treatment Units

Understanding and Caring for Your Septic System

Septic System Care & Maintenance

Homeowner s Manual MIGHTY MAC. For: 500 Gallon-Per-Day. 600 Gallon-Per-Day. 750 Gallon-Per-Day

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

TEX-AIRE, INC Pearl Drive Bossier City, LA

Maintenance Guidelines For Homeowners

Plumbers Guide Pitt Town Water Plumbers Guide, December 21, 2012

YOUR SEPTIC SYSTEM UNCOVERED

DOMESTIC WASTEWATER SYSTEMS

CERTIFYING DRAINLAYER

FAST Owner s Manual. MicroFAST NitriFAST HighStrengthFAST RetroFAST

Homeowners and Home Buyers Guide to Wells and Private Sewage Systems

Please also see 10 golden rules for correct Saniflo installation on

FAST Owner s Manual. MicroFAST NitriFAST HighStrengthFAST RetroFAST

INSTRUCTIONS/INFORMATION HOW TO PROPERLY FILL OUT THE INDIVIDUAL MECHANICAL TREATMENT PLANT WARRANTY INSPECTION / SERVICE REPORT

Time of Transfer Step by Step

Homeowner s Guide to Maintaining a Sewage Treatment System

Septic Tank to Cistern Conversions. Saving Water & Saving Money

OWNER S MANUAL MODEL NUMBERS M-6-A M-8-A M-1050-A M-1200-A M-2000-A

Approved Aerobic Treatment Units

Help protect our special places by maintaining your septic tank

Domestic Wastewater Treatment Up to 6 Population (6PE)

Septic System Management Plan for Below Grade Systems

Complete Solutions for On-Site Wastewater Management

Home comfort: water heating

Indiana Department of Environmental Management. Well Disinfection

BIODISC HIGH PERFORMANCE SEWAGE TREATMENT PLANT FOR DOMESTIC APPLICATIONS

Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS

Septic Tank Maintenance Information

OASIS SERIES 2000 WASTEWATER TREATMENT SYSTEM

Septic Maintenance Brochure How to Care for your Septic System And Lagoon

Septic Systems Maintenance:

SEPTIC SYSTEM. Taking care of your. ... what you need to know

20. ECO-INFO SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT OPTIONS for ON-SITE SEWAGE MANAGEMENT

Frequently Asked Questions about Septic Systems

ON-LOT SEWA G E S Y S T E M S

Operation and Maintenance Guide for Homeowners

The Sewage Plant. The Original! Fully biological. Small sewage. wastewater treatment for. new construction. & retrofitting

CONDENSED CATALOG

Tanks. Manufacturing Tanks Since Home Sewage Treatment Solutions. Clear, odourless, recycled water for irrigation.

FREQUENTLY ASKED SEPTIC SYSTEM QUESTIONS

WASTEWATER TREATMENT OBJECTIVES

SepAerator. Owner s Installation and Maintenance Manual. Toll Free: The Septic Tank Aerator

Understanding Septic Tank Systems

Septic System. Responsibility! Is Your. You should know that:

ALL YOU NEED TO KNOW...

Treatment Industries. Wagga Wagga New South Wales 2650

Water Efficiency Self-Assessment Guide from

Waterwise Display Village Program

System Owner s Manual. PRO FLO WASTEWATER TREATMENT SYSTEMS For All Models: 500, 600, 800, 1000 &1500

Affordable and Reliable. Wastewater. &Rainwater Solutions for Domestic & Commercial Applications FREE. Delivery. On-site advice.

PROPAK AquaBio Complete Water Restoration Systems

PAINT REMOVAL SYSTEM PAINT REMOVAL SPECIFICATION SAFE WORK METHOD STATEMENT FOR LEAD PAINT REMOVAL

Endless Hot Water 24/7

CERTIFIED SEPTIC EVALUATION PREPARED FOR MATT HASHEM 1673 MT. MAJOR HWY, ALTON, NH 03810

ABC CIRCUITS 10 Circuit Drive Circuit Town, IN SLUG CONTROL PLAN

TECHNICAL BULLETIN. Location of the system. Percolation tests for drainage fields. Cesspool sizing. Suggested Information notices

The most advanced Undersink Sullage System with inbuilt controls and alarms.

AerobicSepticSystems.com

Planning and Installing an Onsite Wastewater Management System

OFFALY COUNTY COUNCIL Comhairle Chontae Uibh Fhailí

Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service

Your Pressure Sewerage System Guide

MAINTAINING YOUR SEPTIC SYSTEM by Wrentham Board of Health Ravi Nadkarni, Chairman William R. Domey, Agent

Pipeline HOME AEROBIC WASTEWATER TREATMENT: AN ALTERNATIVE TO SEPTIC SYSTEMS

Greywater Use. Guidelines for residential properties in Canberra. Australian Capital Territory

SHORELINE SANITATION

Nature's Cleaning Process

On-site Sewage Disposal Systems A HOMEOWNER S GUIDE

Session 2: Hot Water Supply

Lance DeClue, REHS Environmental Health Specialist II County of San Diego Department of Environmental Health

BL-DBK150A DUAL BATTERY 12v 150 AMP SMART SYSTEM

Avoiding an expensive

Hot water supply, distribution and use

Town of New Castle Utility Department Introduction

Septic System Owner s Manual

Water Storage Tanks. (Cisterns) Drinking water and your health. Water Hauling. Rainwater Collection. Construction Material

Residential Plumbing BCN 1058

research highlight Remote Monitoring and Control of On-Site Wastewater Treatment, Recycling, and Reuse Systems

Transformer Deluge Systems

6. Principles of effective plumbing systems

Revised April (May) 2015

Understanding and Living With Your Septic System

Development enquiry request

E nv i ro n m e nta l. Biotec 5-7. Sustainable, Reliable, Affordable

CARE AND FEEDING OF...

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Building over or close to a public sewer

Guidance on applying for approval of installation of a commercial onsite wastewater system

Transcription:

water Treatment Industries Design, Manufacture & Distribution Of Sewage Treatment Systems For Domestic & Commercial Dear Thank you for your enquiry concerning the 10 Person Aqua-Nova Treatment System approved by the N.S.W. Department of Health, which carries Quality Assurance certification. This AQUA-NOVA system comes with the following, which is all-inclusive in the price set out below: 1 only 3,000-litre POLYMER baffled septic tank Australian Standards Approved 1 only 3,000-litre POLYMER Sewage Treatment System (NSW Health Approved AWTS 006) TOTAL OPERATING CAPACITY = 6,000 LITRES TOTAL HOLDING CAPACITY = 9,000 LITRES EMERENCY STORAGE UP TO = 2,000 LITRES We also supply the following inclusive of the price set out below: All inter-connecting pipe work between these two tanks 100 M 2 irrigation package including 50 metres of 25mm poly pipe with 5 sprinklers and a pressure relief non-return valve for your convenience Audio/Visual Alarm system DELIVERY TO SITE AND COMMISSIONING SERVICING Your first 12 months of servicing is included in the purchase price of your wastewater system which includes commissioning of system plus 3 services to be conducted on a quarterly basis. Once your last FREE (4 th ) service has been conducted, we will automatically issue you with a service contract for the next 12 monthly period. (Please ask for more details) Please note the above quotation DOES NOT include the following: * Septic tank application fee * Any electrical * Any excavation CHOICE OF 3 DIFFERENT TANK INVERT MODELS 425MM * 750MM * 870MM COST (Including GST) 425MM $ PAYMENT TERMS ARE C.O.D. Yours truly, WARRANTY Tank 25 Years * Electrical components 2 Years * Other components 5 Years * BERNARD NEYLAN DIRECTOR

Aqua-Nova Everhard Industries An Australian Success Story Since 1926 For over 75 years the name Everhard has been at the forefront of experience, service and quality in the manufacture of innovative products designed to provide efficient solutions in the management and treatment of Wastewater. As of 31 October 1999, all wastewater treatment systems in NSW must be accredited under the new and revised NSW Health Department Aerated Wastewater Treatment Systems Accreditation Guideline 1998 to receive council approval for installation. The Aqua Nova system is accredited under these new NSW Health Department guidelines (approval numbers: Concrete System C of A AWTS 004, Polymer System C of A AWTS 006.) It has undergone a rigorous testing program and meets the specified performance criteria in all categories. You can be confident that water treated using the Aqua Nova is clean, odourless and safe. All sales inquiries will be handled by trained and experienced operators In their words the customer talks to the person who is responsible for installing, commissing and servicing the unit We will not use high pressure, untrained, commission sales people. Everhard Industries stands behind our approved distributors, and backs up all warranties and the performance of the unit. We believe this offers the convenience and peace of mind in dealing with local installers backed by the strength and technical know-how of Everhard Industries.

water Treatment Industries DAILY POWER CONSUMPTION AQUA-NOVA 2000 SEWAGE TREATMENT SYSTEM An Aqua-Nova 2000 sewage treatment system was tested at the residence of Mrs Manning at Currawarna, N.S.W in September 2000. TESTING CRITERIA Energy was metered through a Great Southern Energy supply authority kilowatt-hour meter. IRRIGATION PUMP HYDRAULIC LOADINGS Town water supply only 2 Adults & 2 children being of a minimum age of 12 years Irrigation Requirements 1. Submersible Pump servicing 5 sprays on 450mm risers attached to 50 metres of 25mm poly pipe on level ground 2. Irrigation pump size a 10-metre head submersible type. Flow 4 normal loads of washing 4 separate showers per day The dishwasher was put thru a normal daily wash cycle AERATION PUMP NITTO Aeration pump Model LA-80 that ran continuously for 24 hours in the above Aqua-Nova treatment system, which has been commissioned. RESULTS AERATION PUMP used 1.2 kilowatts of electricity IRRIGATION PUMP used 0.85 kilowatts of electricity. TOTAL ELECTRICITY USED = 2.05 Kilowatt x $0.12 cents per kilowatt hour Under the above criteria this system costs 25 cents PER DAY. This case study was conducted in conjunction with Clearwater Industries and Great Southern Energy. BERNARD NEYLAN DIRECTOR

water Treatment Industries

water Treatment Industries

water Treatment Industries ELECTRICAL INSTRUCTIONS All electrical work must be by an appropriately licensed tradesman in accordance with AS3000, and any local regulatory Authority conditions. The AWTS units must be protected by a dedicated 16-amp 8kV circuit breaker. This device must not be installed in the Earth Leakage Loop. Only a single supply line from the controlling switchboard to the AWTS Tank-Top Control Box is required. The minimum cable size is 2.5mm diameter for each of the three wires, Active, Neutral and Earth. The cable from the controlling switchboard to the AWTS Tank should be housed in a suitable protective conduit for its entire length, and buried to a safe depth. The cable location should be noted and marked on the site layout drawings, and a copy supplied to the householder. A section of flexible conduit must be used where the cable emerges from the ground beside the tank, with a loop of cable to allow for ground settlement. The Tank-Top Control Box is fitted with an external Alarm Plate to warn of system failure through loss of electrical power to the air compressor and irrigation pump. This will NOT be activated by a general loss of power to air compressor and the irrigation pump. This will NOT be activated by a general loss of power to the whole installation. No other alarm will be supplied unless specified. Internal

water Treatment Industries LISTED BELOW IS A PARTIAL LIST OF REFERENCES & ACKNOWLEDGEMENTS IN BOTH DOMESTIC AND COMMERICAL SEWAGE TREATMENT EPA (Vic) Approval No CA 040/94 Bargo Caravan Park 15,000 litres per day Dept of Defence Kapooka Army Base 9,000 litres per day Riverina Anglican College 3,000 litres per day Environmental Australia Building Australian Greenhouse Office Transgrid Australian Federal Police Dog on the Tuckerbox Tourist Facility Totalcare (ACT) Civil & Civic Project CO Ordination Tyco Group Caltex Australia Hughes Trueman Pty Ltd

DATE REVISION By CLEARWATER TREATMENT INDUSTRIES PTY. LTD. 17/12/97 Updated RP A.C.N. 07644671 SEPTIC TANK INFORMATION SHEET No.1 DRAWN CHECKED SCALE DRAWING No. B.N. 25/1/97 STI

water Treatment Industries The statements below are known to be true and can be verified by the NSW Health Dept despite claims by some manufacturers in an effort to make quick sales. If you require wastewater-recycling system phone someone who will be here for the long term. The Aqua-Nova system has a factory backing of Everhard Industries 80 year old Australian company with an 80 year old good reputation. FACT All modern systems, no matter what make or brand name, use naturally occurring bacteria to break down and digest waste as a food form. These helpful bacteria when given ideal conditions inside the treatment system will multiply and convert harmful waste products into clean garden irrigation water. FACT Despite the claims of some manufacturers it is extremely inadvisable to dispose of harsh antibacterial cleaners such as bleaches and other chlorine based products as well as strong disinfectants into either septic tanks or treatment systems. These household chemicals cannot differentiate between harmful and helpful bacteria and destroy them all. This is greatly affects the processing of wastewater in all treatment systems. A fact easily verified by your local council health officer. FACT The household use of biodegradable and environmentally friendly cleaners that are low on sodium and phosphorous will reduce the build up of these harmful elements in the soils around your home. FACT All treatment systems require that the water loads from your home spend a given time within the treatment system in order for the treatment process to work. Common sense really! If your washing machine processes and discharges multiple loads, then a huge load of wastewater can prove too much in a short time for the helpful bacteria to properly treat. SIMPLE SOLUTION: Spread your washing loads over several days. *FICTION* - Household treatment systems never need desludging FACT All waste contains some non-organic components and while it is true that aerobic bacteria do digest a large range of waste, eventually an undigested sludge layer will occur. (Ask the owner of a system 7-8 years old) *FICTON* - Homeowners can discharge the treated water anywhere through sprinklers FACT If there were a system malfunction or power failure this discharge could be a health risk, so most Council Health Depts require dripper discharge to your garden, either below soil or a mulch layer. Each Council has its own regulations so give them a call. We are a licensed Everhard approved Local Aqua nova agent with code compliance. Licence No 15047