AerobicSepticSystems.com
|
|
|
- Fay Sanders
- 9 years ago
- Views:
Transcription
1 WHITEWATER AEROBIC WASTWATER TREATMENT UNITS DF SERIES Distributed in Oregon by: For information on sales or service: Randy Arts (541) or Mike Arts (541) AerobicSepticSystems.com
2 Principle Components of a System DF Series aerobic treatment unit Delta effluent pump station or State approved pump filter vault Pump control panel with alarms Delta air compressor(s)
3 General Operation of DF Series Raw wastewater enters the primary septic tank Primary treated wastewater either gravity flows or is pumped to the DF Series unit Aerobic microorganisms oxidizes the organic matter Organic matter is converted to water and carbon dioxide creating mixed liquor and suspended solids (MLSS) MLSS separate in the clarifier, the clear water exits the treatment unit and the remaining MLSS settles and returns to the aeration chamber Secondary treated wastewater gravity flows or is pumped to the drain field depending on the required configuration
4 Delta s DF Series Flow Diagram Air In Sewage In Effluent Out Grade Elev. Plan View (with cover removed) Air In Sewage In Effluent Out Clarifier Aeration Chamber Dirty Water Zone
5 Why Choose Delta? Initial 2 year maintenance contract included Maintained by factory trained, licensed service providers. No mandatory phone line Simple by design = less maintenance - Treatment process is not overly complex, simple to service, less expensive to maintain. Different sizes available 500, 600, 1000 & 1500 gpd. Fast installation Durable fiberglass construction, quick setup, easy to haul and handle Proven process - Same basic principle used in many municipal plants Versatility - Multiple configurations allow for most possible system design Replaces class 1 sand filters -New construction or repair (w/o replacing existing septic tank if approved)
6 Three Approved Installation Configurations* Achieves ATT malfunction prevention compliance Allows for best configuration per site requirements *DF100 & 150 only available in configurations 2 & 3
7 Configuration 1 State approved septic/primary tank DF Series Whitewater unit with Delta air compressor Delta effluent pump station Pump control panel with alarm
8 Configuration 1
9 Configuration 2 State approved septic/primary tank State approved pump filter vault DF Series Whitewater unit with Delta air compressor(s) Pump control panel with alarm
10 Configuration 2
11 Configuration 3 State approved septic/primary tank DF Series Whitewater unit with Delta air compressor(s) State approved dosing tank Effluent pump Pump control panel with alarm
12 Configuration 3
13 ~~Basic Installation notes~~ Maximum burial depth is two feet from tank flange to surface. (12 above riser) These systems will need to be preceded by a septic tank approved for use in Oregon - OAR (3) Dosing tank (if used) must be approved for use in Oregon - OAR (6) Anti-buoyancy is provided by design thru vertical wall sidewall friction.
14 Basic Installation 1. Excavate a hole that allows one foot clearance on all sides of the tank (if space allows) and a depth that will allow approximately 3 inches of the lid to extend above normal ground level. Bed the bottom with a 6 inch layer of sand or gravel if otherwise unable to provide a smooth, level, compact base with native soil. 2. Using the lifting lugs provided, place the unit in the hole. The inlet line from the septic tank can be level with the unit (with minimal fall if necessary). The outlet line should be level with the pump chamber or dosing tank in configurations 1 and 3. The outlet line should slope away from the plant as necessary (a minimum of 1%) in configuration 2. The plant should be level within 1 inch, edge to edge.
15
16 Basic Installation Cont. 3. Open lid and make sure discharge tee assembly is level and centered in clarifier prior to attaching discharge piping. Fill the tank with water up to the discharge before backfilling. Back fill around the treatment plant up to the bottom of the discharge connections. 4. Do not install the air compressor in a low lying area where water may accumulate. The air compressor should be installed near the control panel and within 100 ft. of the tank. The compressor should be installed outdoors in a accessible location in provided enclosure. If the air compressor is to be installed in an alternative enclosure, the enclosure must be approved by Delta in writing.
17 Basic Installation Cont. 5. Mount the control panel in an area so the alarm can be heard and be readily seen*. A 20 amp, 3-wire grounded circuit is required. Install a physical disconnect switch near the control panel if the circuit breaker is not easily accessible. All electrical work shall be done according to NEC and local code requirements. >The control panel must be grounded< *The visual alarm must be conspicuous at a distance of 50 feet and audible alarm must be discernable at a distance of 50 feet. 6. Attach the control panel to secure mounting surface using flange on box. Do not place it where it can be immersed in rising water or where run-off water, such as from a roof, will pour on it. Do not mount it where it is subject to wetting from sprinklers, hoses, etc.
18 Basic Installation Cont. 7. After the control panel is properly mounted, connect conduit for wiring as shown on drawings. 8. Keep sufficient distance between air and electrical lines to avoid confusion of pipes or damage to wiring during installation or repair of air piping. 9. Connect the clear pressure air tubing from the control panel to the compressor or delivery line. 10. Install 3/4" schedule 40 PVC piping between air pump and treatment unit. A minimum of 12" ground cover is recommended. 11. Turn on power to control panel. Air compressor should start.
19 Basic Installation Cont. 12. Check air piping joints for leakage using a soapy water solution. Repair if necessary and then carefully compact bedding under air line, inlet and discharge piping to minimize settling. 13. Test low air alarm circuit by disconnecting clear air tubing from compressor or feed line, alarm should sound in a few seconds. Reconnect air tubing, press reset and alarm should stop. Lift float in Whitewater unit to horizontal position, alarm should sound. Release float, press reset and alarm should stop. Repeat procedure with top float in pump chamber if present. 14. Plant is ready to receive incoming sewage. No special start-up procedures are required. The process is naturally occurring and does not require any special additives.
20 Basic Installation Cont. 15. In the event that a fuse blows, replace with time delay or slow blow, 125 volt minimum voltage rating and the same amp rating as the existing fuse. 16. Check for air discharge into unit, should be obvious gurgling sound. 17. Spend some time to educate your customer whenever possible. Review operation instructions. Be sure that the customer has a manual to keep. This saves valuable time and helps eliminate return visits. 18. Retain these instructions for future reference.
21 Ready for inspection Fill unit with water to outlet. Check level. Make sure there has been no settlement Backfill with suitable material. Leave all piping exposed to view. Have electrical hookup completed. (temp. power if necessary). Start system and listen at vent for heavy gurgling sound. Activate alarms low pressure and both high waters.
22 Delta s Control Panel Features Upon air compressor failure or high water alarm status controller will lock out influent or effluent pump operation Pump lock out feature will stay locked out until reset Alarm lights and audible alarms will indicate which failure is occurring Visual and audible signals are noticeable at 50 feet Audible is between 70 and 90 dba at 5 feet Visual and audible signals are separate from mechanical functions and remain activated during malfunctions except when there is loss of electrical service A visual label with instructions for obtaining service will be attached to control panel
23 Delta s Effluent Pump Station Installation The basin is plastic pipe with sealed fiberglass bottom and optional anti-floatation concrete ring for high water conditions. Do not leave basin in unfilled hole without being filled with water or concrete ring installed as ground water may float basin upwards breaking connections. A 24 w x 4 thick concrete base is recommended for these conditions. Electrical Assembly Install junction box snug to inside of basin to maximize access to other components. Install at a high enough elevation to allow reasonable access for installation and service. Connect pump and float wires with waterproof connectors. Run wires to control panel in conduit using wiring diagram included in control panel. Starting System Open ball valve, fill basin until ON float (second from top) is level and starts pump. The pump should operate until the OFF float (third from top) is level.
24 Basic Service Remove vent, smell for obnoxious odor. Sample mixed liquor suspended solids (MLSS), place in clear quart jar. Clean the compressor lid & filter, check general condition & area for pest invasion. Open lid, break up any scum mat, wash sides of clarifying cone. Check settle ability sample, dump back in system, replace vent cap & lid.
25 SOLIDS REMOVAL The Whitewater Treatment System is designed to provide years of trouble free operation. Determination of the need for solids removal can be done through a simple test. A one quart sample should be pulled from the aeration tank and can be done so through the 4" sample port/vent. Allow the sample to settle in a clear one quart jar for thirty minutes. If the solids content exceeds 50% of the total volume after settling, the treatment plant should be pumped out. Call your local authorized sewage disposal service to have the tank contents pumped out and disposed of properly. The method of pumping out should be as follows: Remove any floating solids by skimming. The air pump must be operating to keep the solids in suspension. Pump out two thirds of the tank volume with the suction pipe opening being placed at the tank bottom. After the pump-out process is complete, fill the tank with fresh water to normal operating level. Refer to the Installation Instructions to get the treatment plant back into operation. Should indication of improper operation be observed at any point in time, contact your local distributor. NOTE: THE COST ASSOCIATED WITH PUMPING THE TREATMENT SYSTEM IS NOT COVERED UNDER WARRANTY AND IS NOT INCLUDED IN THE SERVICE POLICY.
26
27 GENERAL COMMENTS Only factory approved equipment can be used for replacement on treatment system & components. If the decision is made to pump out a system, be sure to contact a licensed waste-hauler. If a chronic problem develops and all items have been checked, consult with the factory representative. Educate the consumer as much as possible, this will limit future frustration. Keep good records, pictures before and after help with locating possible problems.
28 Troubleshooting compressor alarm 1. Air compressor does not run: a. Check main service for power - reset breaker. b. Check fuse - replace with same rating. c. Check if GFCI outlet has tripped - reset 2. Alarm does not occur when air compressor is off: a. Malfunctioning pressure switch - replace. b. Malfunctioning light or buzzer - replace. 3. Alarm occurs continuously even when air compressor is running a. Air leak in main air system or air tubing to pressure switch - repair leak or replace air line. b. Malfunctioning pressure switch - replace. NOTE: All replacement parts are available from your service provider. CAUTION: Electrical shock or hazard may occur if unit is not serviced properly. The manufacturer recommends that a licensed electrician be called when electrical problems occur.
29 HOMEOWNER CARE AND OPERATION INSTRUCTIONS The Whitewater System has been designed and built to provide long term, reliable and efficient service. Once the unit has been installed, it will operate with a minimum amount of attention. Please reference the system s Data Plates that are located on the aerobic tanks 24" cover, air pump, and the alarm panel in the event that a problem arises or service is required. The following should be accomplished as checks for system failure: Daily - Observe the control panel warning device, which comes on when the power to the air compressor has been interrupted, when the air supply system has malfunctioned or a high water situation has occurred. If the alarm is activated, check for a blown fuse or thrown circuit breaker. Weekly - Check air compressor for unusual noise, once accustomed to the soft humming sound of a properly operating unit, any unusual noise is an indication of malfunction. Check for any persistent obnoxious or rotten egg smell coming from the units vent.
30 HOMEOWNER CARE AND OPERATION cont. If any of the problems develop in the daily or weekly sections contact your contract service provider. Twice a year (This will taken care of your contracted service provider) Inspect and make any necessary adjustments to mechanical and electrical components. Inspect effluent quality, color, and check for any odor. Take a sample from the aeration tank and perform a settle ability test described in the Solids Removal section. Break up any sludge that may have developed in the clarifier so it can return back to the aeration zone. Care should be taken to prevent solids from leaving the unit. The homeowner must be notified in writing if any improper operation is observed and can not be corrected at the time of service.
31 ITEMS NOT PERMITTED IN THE SYSTEM Strong disinfectants or bleaches, other than small amounts normally utilized in day to day cleaning and laundry (be conservative). Laundry detergents recommended for use are low-sudsing, low phosphates and biodegradable. Discharge from water softener Any type of oils, greases, or other chemical wastes Disposable baby diapers and wipes Sanitary napkins, condoms or other similar items Hair, bandages, rags, or string Latex, plastic, or metallic objects Coffee grounds or cigarette butts Mud or sticks Paper towels, napkins, or Kleenex Tidy Bowl type products Beer waste or any other rich liquids Garbage disposal should be used sparingly, not as a method of disposing all solid food waste. In order to ensure good plant operation, waste should be disposed of in the garbage container. The Whitewater System is designed to handle domestic wastewater and nothing else should go into it. For anything other than domestic contact: Delta Environmental Products
32 WARNINGS The proper operation of this or any other home sewage system depends upon proper organic loading and the life of the microorganisms inside the system. Delta is not responsible for the in-field operation of a system, other than the mechanical and structural workings of the plant itself. We cannot control the amount of harsh chemicals or other harmful substances that may be discharged into the system by the occupants of a house hold we can only provide a comprehensive owner's manual that outlines substances that should be kept out of the system. Hydraulic overloading (flows in excess of design flow) may cause the sewage treatment system not to perform to the fullest capabilities. Ants have been shown to be destructive to the air compressor. Regular care should be taken to prevent infestation of ants near the system. Damage or destruction by ants is not covered under manufacturer's warranty. Your State or Local Health department may require other pieces of equipment to function separately or in conjunction with equipment manufactured by Delta Environmental Products. Delta Environmental Products is not responsible for the mechanical or electrical safety of equipment it does not manufacture or supply with its aerobic treatment units. Particular care should be used in evaluating the electrical or mechanical safety of equipment manufactured by others. This may include but not be limited to electrical control panels or air pumps. If electrical service has not been installed for checking air distribution system during installation, and if an extension cord is used to test the air compressor, never leave the extension cord plugged in. Remove it after testing is completed. Due to a possible fire hazard, DO NOT plug into service equipment on power pole and DO NOT use extension cords. All electrical work performed by the installer or others must be in accordance with the National Electrical Code and Local Codes. The operation & maintenance outlined in this manual applies to normal operating conditions. Extreme conditions such as frigid cold temperature, extreme heat and high altitudes may effect the operation and maintenance of this unit. Consult Factory regarding these extreme conditions.
33 LIMITED WARRANTY Delta Environmental Products, Inc. warrants the parts in each treatment system as follows: air pump: limited pro-rated five (5) years* first two (2) years 100%, third (3) year 75%, fourth (4) year 50%, fifth (5) year, 25%; fiberglass tanks: limited ten (10) years, metal tanks: limited two (2) years, and concrete tanks: limited two (2) years. All warranty questions shall be resolved through Delta Environmental Products, Inc. The warranty on the treatment device is that the device is free from defects in material and workmanship from the date of installation treating household wastewater. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply. The sole obligation under this warranty is as follows: Delta Environmental Products, Inc. shall fulfill this warranty by repairing or exchanging any component part, F.O.B. factory that in Delta Environmental Products, Inc. judgment shows evidence of defects, provided said component part has been paid for and is returned through an authorized dealer, transportation prepaid. The warrantee must also specify the nature of the defect to the manufacturer. The warranty does not cover treatment processes/devices that have been flooded, by external means, or that have been disassembled by unauthorized persons, improperly installed, subjected to external damage or damaged due to altered or improper wiring or overload protection. This warranty applies only to the treatment process/device and does not include any of the house wiring, plumbing, drainage, or disposal system. Delta Environmental Products, Inc. is not responsible for any delay or damages caused by defective components or material, or for loss incurred because of interruption of service, or for nay other special or consequential damage or expenses arising from the manufacture, sale or use of this process/device.
34 LIMITED WARRANTY CONT. Delta Environmental Products, Inc. reserves the right to revise, change or modify the construction and design of the treatment process/device for household wastewater or any component part or parts thereof without incurring any obligation to make such changes or modifications in previously sold equipment. Delta Environmental Products, Inc. also reserves the right, in making replacements of component parts under this warranty, to furnish a component part which, in its judgment is equivalent to the part replaced. Under no circumstances will Delta Environmental Products, Inc. be responsible to the warrantee for any other direct or consequential damages, including but not limited to lost profits, lost income, labor charges, delays in production, and/or idle production, which damages are caused by a defect in material and/or workmanship in its parts. Some states do not allow the exclusion of limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The warranty is expressly in lieu of any other express or implied warranty, excluding any warranty of merchantability or fitness and of any other obligation on the part of Delta Environmental Products, Inc. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. *The 3, 4, and 5 year pro-rated portion of this warranty is only valid with a continuing Service Policy in effect. Proof of this continuing Service Policy must be provided.
TEX-AIRE, INC. 1076 Pearl Drive Bossier City, LA 71111 318-752-3700
TEX-AIRE, INC. 1076 Pearl Drive Bossier City, LA 71111 318-752-3700 MIGHTY MAC Aerobic Wastewater Treatment Homeowner s Manual For MIGHTY MAC 500 Gallon-Per-Day MIGHTY MAC 600 Gallon-Per-Day MIGHTY MAC
Homeowner s Manual MIGHTY MAC. For: 500 Gallon-Per-Day. 600 Gallon-Per-Day. 750 Gallon-Per-Day
Homeowner s Manual For: MIGHTY MAC 500 Gallon-Per-Day 600 Gallon-Per-Day 750 Gallon-Per-Day Table of Contents I. Introduction II. About Your MIGHTY MAC System III. Homeowner (System Owner) Responsibilities
Understanding and Caring for Your Septic System
Understanding and Caring for Your Septic System Summit County Public Health 1867 W. Market Street Akron, Ohio 44313 330-926-5600 www.scphoh.org The purpose of a home's subsurface septic system is to dispose
A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS
GEORGIA DEPARTMENT OF HUMAN RESOURCES ENVIRONMENTAL HEALTH SECTION A HOMEOWNERS GUIDE TO ON-SITE SEWAGE MANAGEMENT SYSTEMS March 12, 2002 WHAT IS AN ON-SITE SEWAGE MANAGEMENT SYSTEM An on-site sewage management
OWNER S MANUAL MODEL NUMBERS M-6-A M-8-A M-1050-A M-1200-A M-2000-A
OWNER S MANUAL MODEL NUMBERS M-6-A M-8-A M-1050-A M-1200-A M-2000-A Consolidated Treatment Systems, Inc. 1501 Commerce Center Drive Franklin, OH 45005 Tel: 937-746-2727 Fax: 937-746-1446 www.consolidatedtreatment.com
ECOFILTER PUMP VAULT
ECOFILTER PUMP VAULT SEPTIC TANK PUMP VAULT FILTER SYSTEM SAFETY INSTRUCTIONS, INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip
FAST Owner s Manual. MicroFAST NitriFAST HighStrengthFAST RetroFAST
FAST Owner s Manual FOR USE WITH (NSF Std 40 & 245) MicroFAST 0.5, 0.625, 0.75, 0.9, 1.5 (non NSF certified) MicroFAST 3.0, 4.5, 9.0 (ETV/EPA tested) RetroFAST 0.150, 0.250, 0.375 NitriFAST 0.5, 0.625,
FAST Owner s Manual. MicroFAST NitriFAST HighStrengthFAST RetroFAST
FAST Owner s Manual FOR USE WITH (NSF Std 40 & 245) MicroFAST 0.5, 0.75, 0.9, 1.5 (non-nsf certified) MicroFAST 3.0, 4.5, 9.0 (ETV/EPA tested) RetroFAST 0.150, 0.250, 0.375 NitriFAST 0.5, 0.75, 0.9, 1.5,
Homeowner s Guide to Maintaining a Sewage Treatment System
Homeowner s Guide to Maintaining a Sewage Treatment System Warren County Combined Health District 416 South East Street Lebanon, OH 45036 513-695-1220 Sewage Treatment Systems Septic Tank and Soil Absorption
CLEARSTREAM WASTEWATER SYSTEMS, INC.
CLEARSTREAM WASTEWATER SYSTEMS, INC. P. O. Box 7568 Beaumont, Texas 77726-7568 (409) 755-1500 Fax: (409) 755-6500 www.clearstreamsystems.com OWNER S MANUAL PARTS LIST OPERATING MANUAL FLOW DIAGRAM INSTALLATION
INSTRUCTIONS/INFORMATION HOW TO PROPERLY FILL OUT THE INDIVIDUAL MECHANICAL TREATMENT PLANT WARRANTY INSPECTION / SERVICE REPORT
INSTRUCTIONS/INFORMATION HOW TO PROPERLY FILL OUT THE INDIVIDUAL MECHANICAL TREATMENT PLANT WARRANTY INSPECTION / SERVICE REPORT Section 1. SITE INFORMATION: All fields in this form must be filled in accurately
System Owner s Manual. PRO FLO WASTEWATER TREATMENT SYSTEMS For All Models: 500, 600, 800, 1000 &1500
PRO FLO WASTEWATER TREATMENT SYSTEMS For All Models: 500, 600, 800, 1000 &1500 IMPORTANT! It is important that you read and understand your System Owner s Manual. This manual contains information you should
NAYADIC TROUBLE-SHOOTING CHECKLIST
(IMPORTANT: Disconnect power to compressor or alarm before attempting repairs.) I. COMPRESSOR A. New compressor will not start but 1. Rotary assembly is locked up due 1. Remove internal filters, muffler
31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE
31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE Edited 21/12/01 Wyong Shire Council has many non sewered areas that
Septic Tank Use & Maintenance Tips
Yellowhead County Hamlet of Cadomin Septic Tank Use & Maintenance Tips This guide gives an overview of the responsibilities for property owners in Cadomin. For Seasonal, Permanent & Vacationing Cadomin
SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL
SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN
S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN AUTOMATIC S33A1 & S33A1C R WARNING risk of electric shock.
SEPTIC SYSTEMS. 1. Building sewer connects the building plumbing to the septic tank.
SEPTIC SYSTEMS Who Has A Septic System? Approximately 30 percent of Connecticut s population is served by on-site subsurface sewage disposal systems (a.k.a. septic systems). This means a large percentage
ON-LOT SEWA G E S Y S T E M S
ON-LOT SEWA G E S Y S T E M S An Owner s Manual Chester County Health Department Bureau of Environmental Health Protection TABLE OF CONTENTS Page What is an on-lot sewage system 1 Types of on-lot systems
Septic Tank Maintenance Information
Septic Tank Maintenance Information This section has been adapted from materials developed by the Rouge RAP Advisory Council On-site Septic Subcommittee, which included representatives from Oakland, Wayne
SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT
SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT The following are minimum requirements for installation of conventional trench sewage disposal systems in St. Mary s County,
SepAerator. Owner s Installation and Maintenance Manual. www.septicaerator.com. Toll Free: 1-877-925-5132. The Septic Tank Aerator
SepAerator TM The Septic Tank Aerator Developed By Septic Solutions, Inc. Owner s Installation and Maintenance Manual Patent 7,513,995, Patent 7,708,259 and Patent Pending. Innovative! Inexpensive! Incredible
Frequently Asked Questions about Septic Systems
What is a septic tank? Where is my septic tank located? Do septic tanks last forever? What should and should not go into my septic tank? How can I tell if my septic tank is working properly? Why should
SEPTIC TANK SYSTEMS. Single purpose septic tank receives toilet wastes (blackwater) or sullage (greywater) only.
SEPTIC TANK SYSTEMS There are three common types of septic tank systems in Tasmania Single purpose septic tank receives toilet wastes (blackwater) or sullage (greywater) only. Dual purpose (or all-waste)
SEPTIC SYSTEM. Taking care of your. ... what you need to know
Taking care of your SEPTIC SYSTEM... what you need to know For more information, please call: WATER & WASTE MANAGEMENT PROGRAM (909) 387-4666 Visit our web site: www.sbcounty.gov/dehs A:\Septic System
ALL YOU NEED TO KNOW...
ALL YOU NEED TO KNOW... What do you know about your septic tank system? For the purposes of this booklet, a septic tank system refers to any kind of on-site sewage management system including traditional
Operation and Maintenance Guide for Homeowners
LAGOON SEWAGE TREATMENT SYSTEMS It s Your On-Site System Operation and Maintenance Guide for Homeowners OKLAHOMA DEPARTMENT OF ENVIRONMENTAL QUALITY ENVIRONMENTAL COMPLAINTS AND LOCAL SERVICES P.O. Box
Looking after your Septic Tank System
Looking after your Septic Tank System Name: Bought to you by Address: File this in your property file. 0800 TO FLUSH Call 0800 TO FLUSH 1 What do you know about your septic tank system? Just like your
Septic System Owner s Manual
Septic System Owner s Manual Sponsored by: copyright 2013 No part of this publication may be reproduced without our consent. www.callbrownies.com Brownie s Septic and Plumbing has provided quality service
MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.
Specifications for Residential Property Owners Connection to New Public Sewer
Specifications for Residential Property Owners Connection to New Public Sewer Spalding Tract property owners are required to connect to the community sewer system when construction is complete and the
WASTEWATER MANAGEMENT SYSTEM
WASTEWATER MANAGEMENT SYSTEM PROTECT WHAT S MOST IMPORTANT TO YOU... Choosing to live in a suburban or rural area without a municipal sewer no longer means having to live with the problems associated with
860-7668 KNOWING AND MAINTAINING YOUR SEPTIC SYSTEM. Carleton Pumping Services We look forward to hearing from you! DON T PANIC!
DON T PANIC! WE LL SAVE YOU FROM YOUR PROBLEMS... Drain Cleaning Pipe Locating Water Jetting Maintenance Camera Inspect ion Plumbing KNOWING AND MAINTAINING YOUR SEPTIC SYSTEM 860-7668 Carleton Pumping
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
WASTEWATER TREATMENT OBJECTIVES
WASTEWATER TREATMENT OBJECTIVES The student will do the following: 1. Define wastewater and list components of wastewater. 2. Describe the function of a wastewater treatment plant. 3. Create a wastewater
Properly maintaining your septic system will help reduce the. It s Your Septic System. Homeowner s Guide. Here s How to Take Care of It
Homeowner s Guide for Maintenance and Care of On-Site Sewage Systems It s Your Septic System Here s How to Take Care of It Properly maintaining your septic system will help reduce the possibility of health
Ceiling Mount Air Handler Manual
www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty
What Is An On-Lot Sewage Disposal System?
What Is An On-Lot Sewage Disposal System? Most rural homes and communities in Monroe County are not served by a public sewer system. In order to dispose of the wastewater (sewage) generated by homes and
Checklist for plans to Construct, Alter or Repair An Individual Subsurface Sewage Disposal System
Checklist for plans to Construct, Alter or Repair An Individual Subsurface Sewage Disposal System An application for the construction or alteration of an individual subsurface sewage disposal system shall
septic systems What is a Septic System? How does a Septic System Work?
septic systems What is a Septic System? A septic system is a private sewage treatment system. They are common in rural areas where there are no municipal sewage pipes for homes, farms, businesses or other
Septic System Management Plan for Below Grade Systems
The goal of a septic system is to protect human health and the environment by properly treating wastewater before returning it to the environment. Your septic system is designed to kill harmful organisms
Nature's Cleaning Process
Nature's Cleaning Process Students learn how a septic system cleans wastewater by performing an experiment. Level(s): 6-8 Subject(s): Physical Science, Chemistry, Life Science Virginia SOLs: 6.5 f, g;
Electric Panel Pump Control System. Operation, Maintenance and Installation Manual
Manual No. 5EP-OM1-1 Electric Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 SEQUENCE
Puraflo Peat Fiber Biofilter
Puraflo Peat Fiber Biofilter Owner s Manual Only modules bearing the NSF logo and designated P150N*XX are certified to NSF/ANSI Standard 40 2014 Anua 10-2014 Table of Contents 1.0 Classification Statement
Septic System. Responsibility! Is Your. You should know that:
Southwest Florida Water Management District Septic System Your Is Your Responsibility! PIPE SEPTIC TANK DRAIN FIELD SOIL You should know that: As a homeowner you re responsible for maintaining your septic
MODEL NO. QWIK JON 100/101/102 SYSTEMS DATE CODE: INSTALLATION INSTRUCTIONS DATE INSTALLED: PREINSTALLATION CHECKLIST
NOTICE TO INSTALLER: Instructions must remain with installation. SECTION: 6.10.065 FM1469 Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies
MAINTAINING YOUR SEPTIC SYSTEM by Wrentham Board of Health Ravi Nadkarni, Chairman William R. Domey, Agent
INTRODUCTION MAINTAINING YOUR SEPTIC SYSTEM by Wrentham Board of Health Ravi Nadkarni, Chairman William R. Domey, Agent To most people, a septic system (or a cesspool) is out of sight and out of mind.
Electric Water Heater
Electric Water Heater Operation and Installation Manual (LIMITED WARRANTY AND TANK REPLACEMENT POLICY) The following information should be noted at time of installation and retained for future reference.
Town House 11265 Center Highway North Huntingdon, PA 15642
APPENDIX C SPECIFICATIONS FOR THE CONSTRUCTION OF BUILDING LATERAL SANITARY SEWERS DECEMBER 2004, INCLUDING AMENDMENTS ADOPTED ON FEBRUARY 6, 2008 AND APRIL 2, 2008; EFFECTIVE ON MAY 1, 2008 Town House
Septic Records and Maintenance Guidelines
1 Septic Records and Maintenance Guidelines Proper design, installation, and maintenance of your septic system will maximize your system's life. It will prevent failures that can be unsightly, foul-smelling,
CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13
CONTROL PANEL INSTALLATION INSTRUCTIONS Single Phase Simplex Page 2-7 3-Phase Simplex Page 8-13 Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions
Homeowners and Home Buyers Guide to Wells and Private Sewage Systems
Homeowners and Home Buyers Guide to Wells and Private Sewage Systems What every homeowner should know about living with a well and a private sewage system. YOUR ENVIRONMENTAL SYSTEMS Out of sight out of
402-475-2462. Septic Maintenance Brochure How to Care for your Septic System And Lagoon
Septic Maintenance Brochure How to Care for your Septic System And Lagoon Check out our website at www.southwickliquidwaste.com Jason and Jaime Kubik (owners) 105 Locust Street Hickman, NE 68372 402-475-2462
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
ONSITE WASTEWATER TREATMENT SYSTEM Property Transfer Certification Instructions and Inspection Report
ONSITE WASTEWATER TREATMENT SYSTEM Property Transfer Certification Instructions and Inspection Report These instructions are for homeowners and inspectors completing the onsite wastewater treatment system
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
Instruction Manual. Image of SP-3015 & SP-3815. Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function
Important Safeguards READ ALL INSTRUCTIONS BEFORE USE. Instruction Manual Automatic Dispensing Hot Water Pot with Reboil Function Image of SP-3015 & SP-3815 SP-3015: 3.0L SP-3815: 3.8L SP-3017: 3.0L (Stainless
CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION
CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION Grease, So What's the Problem? Does your facility produce grease? All commercial cooking facilities generate Fats, Oil, and Grease
Wilo SP Series Submersible Sump Pumps ECS. ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions
Wilo SP Series Submersible Sump Pumps ECS ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions PREINSTALLATION CHECK Inspect this pump before it is used. Occasionally, pumps can
CERTIFIED SEPTIC EVALUATION PREPARED FOR MATT HASHEM 1673 MT. MAJOR HWY, ALTON, NH 03810
DATE: May 31, 2013 N.H. LICENSED DESIGNER OF SUBSURFACE DISPOSAL SYSTEMS 216 Hill Road Phone & Fax: 934-6206 Franklin, NH 03235 Cell: 393-3085 CERTIFIED SEPTIC EVALUATION PREPARED FOR MATT HASHEM 1673
Installation Manual DIAPHRAGM WELL TANK
Installation Manual DIAPHRAGM WELL TANK IN-LINE SERIES: 2-5 & 7 GALLON VERTICAL SERIES: 14-20-25-32-36-52-65-86-96-119 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON NO LEAD NO LEAD: The weighted average of
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT
SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT The purpose of these specifications is to insure that there are minimum
OASIS SERIES 2000 WASTEWATER TREATMENT SYSTEM
OASIS SERIES 2000 WASTEWATER TREATMENT SYSTEM OWNERS MANUAL IMPORTANT: ALL WORK MUST CONFORM TO LOCAL BUILDING, ELECTRICAL AND PLUMBING CODES 010312 1 Oasis Series 2000 Owners Manual PLEASE READ We urge
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
Septic System Owner s Manual
Septic System Owner s Manual How your septic system works and how to keep it working for you and the environment CORPORATION Innovative Environmental Products and Solutions Since 1970 Table of Contents
English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...
2 Contents Components Attachments Guidance Installation Operation Maintenance Service Technical Troubleshooting Symbols used to mark instructions...3 Included Attachments...4 Congratulations...5 Getting
1/3 HP Submersible Sump Pump with Vertical Float Switch
1/3 HP Submersible Sump with Vertical Float Switch Item 68476 Specifications Float Switch Operation Height 7.1 IN. ON / 2.8 IN. OFF Electrical Requirements 120V~ / 60Hz / 7.6A Power Length Maximum Capacity
Septic System Care & Maintenance
Septic System Care & Maintenance A User s Guide for Home/Cottage Owners Spring 2003 Preventing Septic Failure & Malfunction How many of us know how our septic system works, or think we know? We expect
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
ClearView 100. Instruction Manual
ClearView 100 Instruction Manual Important Safeguards This appliance is not intended for use by children or infirm persons without supervision. Young children should be supervised to ensure that they do
Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service
Experts Review of Aerobic Treatment Unit Operation and Maintenance Bruce Lesikar Texas AgriLife Extension Service Overview Overview of Aerobic Treatment Units Installing for accessibility to system components
Protect Your Home From Flooding. A guide for Lethbridge Residents
Protect Your Home From Flooding A guide for Lethbridge Residents Every year, millions of litres of water flow into the City of Lethbridge s stormwater and wastewater collection systems from residential
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
WHITEWATER AEROBIC TREATMENT UNIT
WHITEWATER AEROBIC TREATMENT UNIT DF DESIGN MANUAL P.O. BOX 969, DENHAM SPRINGS, LA 70727 (225) 665-6162 Telephone (225) 664-9467 Fax Revised 03/01/06 DELTA ENVIRONMENTAL PRODUCTS, INC. WHITEWATER HOME
OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE
OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:
WHAT YOU NEED TO KNOW...
A GUIDE TO OPERATING & MAINTAINING YOUR SEPTIC SYSTEM WHAT YOU NEED TO KNOW... The way you treat your septic system will influence how long the system lasts and how well it functions. If you own or rent
Utility Distribution Systems
Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Indiana State Department of Health Construction Guidelines for Gravity and Flood-Dose Trench Onsite Systems
Indiana State Department of Health Construction Guidelines for Gravity and Flood-Dose Trench Onsite Systems The septic tank-absorption field sewage treatment system is composed of two major elements; the
Septic Systems Maintenance:
Septic Systems Maintenance: A typical septic system consists of two basic components: a septic tank and an underground disposal field. Wastewater flows from the house to the septic tank. Effluent, after
THURSTON COUNTY SEPTIC TANK PUMPERS' MANUAL
THURSTON COUNTY SEPTIC TANK PUMPERS' MANUAL PREPARED BY: Environmental Health Division, Thurston County Public Health and Social Services Department WITH FUNDING FROM: The Puget Sound Water Quality Authority
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075
Part No. 89047 Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075 Cincinnati, OH 45241-4807 USA ELECTRIC FRYER SAFETY PRECAUTIONS Installation
FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL
FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL Please follow instructions for repairing if any otherwise do not alter or repair any parts of device except specified. IMPORTANT SAFETY INSTRUCTIONS
Maintenance Guidelines For Homeowners
ON-SITE WASTEWATER SYSTEMS Maintenance Guidelines For Homeowners PROTECTING YOUR HEALTH, YOUR ENVIRONMENT, YOUR INVESTMENT PRODUCED BY: SWANS-SIG The Small Wastewater And Natural Systems Special Interest
FREQUENTLY ASKED SEPTIC SYSTEM QUESTIONS
FREQUENTLY ASKED SEPTIC SYSTEM QUESTIONS What is an OSSF (On-Site Sewage Facility)? This is the term used when referring to "septic systems". What is septic system? A septic system is a method of dealing
Wine Cooler with Thermo-Electric Cooling & Heating Technology
Wine Cooler with Thermo-Electric Cooling & Heating Technology Model number: WC-0888H (8-bottles capacity) Instruction Manual Please read carefully and follow all safety rules and operating instructions.
Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
CONDENSED CATALOG WWW.DELTAENVIRONMENTAL.COM
DELTA ENVIRONMENTAL RESIDENTIAL TREATMENT CONDENSED CATALOG WWW.DELTAENVIRONMENTAL.COM DELTA ENVIRONMENTAL The Difference is Clear Introduction to Delta Environmental Founded in 1985, Delta Environmental
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling
Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling February 2001 contents General Information 3 Inspection 4 New Drain and Vent Installations
MASTER. Installation and Operation Manual. Water Conditioning Corp. MCA Time Clock Series Residential Softeners. February 2011 Version
MASTER Water Conditioning Corp. Installation and Operation Manual MCA Time Clock Series Residential Softeners February 2011 Version Table of Contents Page No. Topic Description 1 Model # and Packaging