PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems



Similar documents
Affordable and Reliable. Wastewater. &Rainwater Solutions for Domestic & Commercial Applications FREE. Delivery. On-site advice.

SEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE

E nv i ro n m e nta l. Biotec 5-7. Sustainable, Reliable, Affordable

BIODISC HIGH PERFORMANCE SEWAGE TREATMENT PLANT FOR DOMESTIC APPLICATIONS

SECTION 18 Kingspan Environmental

TECHNICAL BULLETIN. Location of the system. Percolation tests for drainage fields. Cesspool sizing. Suggested Information notices

PUMPSTOR COMPLETE WASTE WATER AND SURFACE WATER PUMPING SOLUTIONS

DOMESTIC WASTEWATER SYSTEMS

Foul Drainage, systems and responsibility. Environmental Protection

Pollution Control NEW! NEW! Stormwater Attenuation Systems Sustainable Urban Drainage Solutions for Domestic & Commercial Applications. klargester.

Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS

A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS

On Site Treatment Systems

Homeowners and Home Buyers Guide to Wells and Private Sewage Systems

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

Domestic Wastewater Treatment Up to 6 Population (6PE)

SEPTIC TANK SYSTEMS. Single purpose septic tank receives toilet wastes (blackwater) or sullage (greywater) only.

Georgia Department of Public Health. Georgia Onsite Sewage Management Systems. Background and Use of Onsite Wastewater Treatment Systems in Georgia

Type of Sewer Systems. Solomon Seyoum

Septic System Owner s Manual

SHORELINE SANITATION

Sewage Disposal. Dr. Benjamin P.L. Ho Department of Mechanical Engineering The University of Hong Kong

Looking after your Septic Tank System

SEPTIC TANKS AND SOAKAWAYS TO HOUSES AND THE BUILDING REGULATIONS

SEPTIC SYSTEMS. 1. Building sewer connects the building plumbing to the septic tank.

Sewerage Management System for Reduction of River Pollution

9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES. Hunter Underground Systems

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

Aeroclere CLP6 Wastewater Treatment System for Single Dwellings.

CERTIFYING DRAINLAYER

Guidance on applying for approval of installation of a commercial onsite wastewater system

On-site Treatmentt for Domestic Wastewater in Thailand Suwanna. K. Boontanon Mahidol Univ. 2

Aerated Wastewater T r eatment System

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

ALL YOU NEED TO KNOW...

A Property Owner s Guide

Fact sheet 6: for farmers

Building over or close to a public sewer

ON-LOT SEWA G E S Y S T E M S

Frequently Asked Questions about Septic Systems

Polypipe Continuing Professional Development. Rainwater Harvesting In The Sustainable Environment

The most advanced Undersink Sullage System with inbuilt controls and alarms.

ONSITE WASTEWATER TREATMENT SYSTEM Property Transfer Certification Instructions and Inspection Report

Commercial Services OVERVIEW

Septic Tank to Cistern Conversions. Saving Water & Saving Money

Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities

WaReg The Flow Regulator

SECTION 6 EXISTING WASTEWATER MANAGEMENT SYSTEMS

The Sewage Plant. The Original! Fully biological. Small sewage. wastewater treatment for. new construction. & retrofitting

water Treatment Industries Design, Manufacture & Distribution Of Sewage Treatment Systems For Domestic & Commercial

POLLUTION PREVENTION GUIDELINES DISPOSAL OF SEWAGE WHERE NO MAINS DRAINAGE IS AVAILABLE: PPG4 1. NEW PUBLIC SEWERS 2. SEPTIC TANKS

INDEX. Introduction 3. The Septic System 3. What Does The Septic Tank Do? 4. Where It All Goes 5. Problems 7. Some Dontʼs 8

Complete Solutions for On-Site Wastewater Management

MARICOPA COUNTY ENVIRONMENTAL HEALTH CODE CHAPTER II SEWAGE AND WASTES SECTION 8

The Flow Regulator. Flow regulation

Northeast Tri County Health District

Septic System. Responsibility! Is Your. You should know that:

OPERATION OF KLARGESTER SEPTIC TANKS

Understanding Septic Tank Systems

16. Storm water drainage

Improper storage of fuel on construction sites will increase the risk of water pollution that may occur as a result of leaks or spills.

MAINTENANCE AND SERVICING OF SMALL WASTEWATER TREATMENT SYSTEMS (PACKAGE PLANTS) UP TO 50 POPULATION EQUIVALENTS (PE) AND LARGER SYSTEMS UP TO 1000 PE

ACO Water Management: Civils + Infrastructure

SUMP PUMP DISCHARGES INFORMATIONAL PACKET

ON-SITE WASTEWATER TREATMENT SYSTEMS ACT

CLEARSTREAM WASTEWATER SYSTEMS, INC.

save water, save money, save the environment Monsoon domestic rainwater harvesting systems

Prepare a drainage system layout and specification notes for a low- rise building.

ENVIRONMENTAL HEALTH FACT SHEET NO. 500

FAST Owner s Manual. MicroFAST NitriFAST HighStrengthFAST RetroFAST

Final Report On the Effect of Macerating Toilets on Septic Tank Performance

Environmental Management System Procedures

research highlight Remote Monitoring and Control of On-Site Wastewater Treatment, Recycling, and Reuse Systems

YOUR SEPTIC SYSTEM UNCOVERED

FREQUENTLY ASKED QUESTIONS

UVDB empowered by Achilles

TOWN OF YARMOUTH. L.L. Pzpr

Application for Planning Permission. Town and Country Planning Act 1990

What Is An On-Lot Sewage Disposal System?

septic systems What is a Septic System? How does a Septic System Work?

FLUIDO. Fully Biological Sewage Treatment Plant. We clear it for you. according to EN Packaged Sewage Solutions with a Future (4-300 PT)

Drainage. Information for those with problem drains

Fact sheet 6: for farmers

OFFALY COUNTY COUNCIL Comhairle Chontae Uibh Fhailí

SUMMIT COUNTY COMBINED GENERAL HEALTH DISTRICT

Improving on-site domestic wastewater treatment systems - West Coast Lagoons Project

FAST Owner s Manual. MicroFAST NitriFAST HighStrengthFAST RetroFAST

Help protect our special places by maintaining your septic tank

CITY OF ST. CA THARINE S. cn- Olc.4 BY-LAW NO. WHEREAS the Council of the Corporation of the City of St. Catharines, is

Trade Waste Management Plan for Industrial Customers

National Precast Concrete Association

KAWERAU DISTRICT COUNCIL General Bylaw Part 9: On-site Wastewater Disposal Systems (2010)

Fusion Series Treatment Systems Small Scale Residential & Commercial Treatment Units

Septic System Management Plan for Below Grade Systems

GUERNSEY OIL INSTALLATION GUIDELINES

Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service

DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS

Understanding and Living With Your Septic System

Transcription:

PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems

PACKAGE SEWAGE TREATMENT SYSTEM Clearwater treatment plants are ideal for single houses and employ the well proven aerobic biological process for the treatment of sewage. Certificated to European Standard EN-12566 In 2005, a new European Performance Standard was introduced. EN-12566 requires manufacturers to submit their product to a testing regime that accurately measures the performance of treatment plants up to 50 population. These tests identify how much pollution the treatment plant removes from the sewage, what level of maintenance is required, and what power is absorbed. By holding EN-12566 certification, the Clearwater treatment plant is approved for an exemption from a permit to discharge under the new EPP2 environmental legislation. For more information on EPP2 and off-mains regulations please contact us. Three distinct process stages take place within the single tank: First, coarse solids are filtered and retained for gradual breakdown. Then the resulting liquid is continuously distributed over a plastic suspended filter by an integral lift, powered by a remotely sited blower. Finally, the solids are allowed to settle and, under normal domestic conditions, treated water of 20mg/l BOD, 0mg/l S.S., 20mg/l Ammonia can be achieved. Typical Plan Cutaway Plan 1 Treatment plant 2 1 Inspection manhole 2 Existing soil Irrigation drainage Inspection manhole Effluent suitable for discharge to watercourse with consent. 2

5 1 Inlet 2 Main body 1 Lid 5 Lockable access cover Blower 6 2 6 Outlet Integral Pump Systems Benefits Superior performance rating. Subject to consent and site conditions, the plant can discharge directly to a watercourse. No mechanical or electrical components within the plant - low running and maintenance costs. Low level visibility with a lockable child-proof pedestrian duty cover - safe for children and pets. Controlled ventilation - minimises risk of odour nuisance. Package options to all requirements and needs. Easy to install and maintain with annual desludging. Technical Details You may find that your soakaway area/watercourse area is some distance away from the outlet pipe where the treatment plant releases the treated water. If this is the case, you may need to use a model which has the ability to pump treated water. These are our Integral Pump models (IPS). Please contact us for further information. Single Pump System (50mm OD MDPE Pipe) Height to be pumped (metres) 6 5 2 1 0 0 50 100 150 200 Pumping distance (metres) Model Type 6 12 18 Model Ref. E006G10A0B E012G10A0B E018G10A0B Max. No. of Full-time Residents p/day 6 12 18 Average Flow m /day 1.20 2.0.60 BOD Load kg/day 0.6 0.72 1.10 Weight Empty kg 200 217 5 Overall Diameter m 1.85 1.85 2.70 Overall Depth m 2.20 2.70 2.60 Inlet Invert m 1.00* 1.00* 1.00* Inlet Invert to Base m 1.20 1.70 1.60 Outlet Invert m 1.10** 1.10** 1.10** Blower Motor Rating Watts 60 60 1.50 Drainage Fitting mm 110 110 110 * There are two depths of inlet in the range 1.0m and 1.5m. **0.605m on IPS models. Under normal domestic conditions a discharge of 20mg/l BOD, 0mg/l SS and 20mg/l ammonia can be achieved.

SEPTIC TANKS & CESSPOOLS Septic Tank Clearwater units are available in two shapes, spherical and cylindrical, with sizes suitable for all domestic applications. Clearwater septic tanks are designed to meet both the installation requirements and the standards of discharge specified by BS 6297: 198. Clearwater tanks are used for domestic sewage disposal where connection to a mains sewer is not practical. The septic tanks in the range all achieve a high degree of settlement, producing a quality of effluent for discharge to a land drainage system. Septic Tanks & Cesspools A septic tank consists of a two or three chamber system that retains sewage from a property for sufficient time to allow the solids to form into sludge at the base of the tank, where it is partially broken down through anaerobic digestion. The remaining liquid in the tank then overflows from the tank by means of an outlet pipe to a drainage field. Spherical septic tanks are manufactured as standard from 2,800 to,600 litres net working capacity. Cesspool Cylindrical cesspools are available with capacities from 18,000 to 26,000 litres. The cylindrical tank allows reduced depth excavation in comparison with the same size of spherical tank, offering considerable savings where ground conditions are difficult or where there is a high water table. Cesspools are designed for storage only, with their contents being emptied at regular intervals using tankers. High Level Alarms with audible and visual warnings are available for all tanks to enable level monitoring for optimum use. When sizing a storage tank for domestic properties it must be noted that under the Building Regulations it must have a minimum capacity of 18,000 litres (2 people) under Environment Agency regulations. When siting units there are a number of factors to be considered. Systems should not be positioned closer than 7 metres to any dwelling and as far as possible from any watercourse, normally not less than 10 metres. Adequate access to tankers for emptying should also be taken into consideration.

Septic Tank and Cesspool Selection Chart Septic Tanks (Spherical) Cesspools (Cylindrical) Capacity Model Capacity Diameter A Height B Capacity Diameter C Length D (litres) Ref: (gallons) (mm) (mm) (gallons) (mm) (mm) 2,800 STS0281OB 615 1,905 2,565 - - -,800 STS081OB 85 2,070 2,795 - - -,600 STS061OB 1011 2,080,05 - - - 18,000 CP2818S10CB - - -,000 2,600,20 22,000 CP2822S10CB - - - 5,000 2,600 5,090 26,000 CP2826S10CB - - - 6,000 2,600 6,190 Septic Tanks have a 1.0m standard invert depth. 1.5m inverts are available upon request. Cesspools are available with invert depths of up to 2.0m. For deeper cesspool inverts please contact our technical sales team. Septic Tank Cesspool B C A D Storage Tanks Clearwater storage tanks provide a reliable solution for the collection and retention of: Surface water; Firefighting reservoirs; Rainwater harvesting reservoirs; Animal drinking reservoirs. * For silage storage, please inquire. The spherical tank is the simplest and most economical solution to domestic sewage disposal The cylindrical tank allows reduced depth excavation, resulting in cost savings 5

PUMPING STATIONS A range of wastewater pump systems for residential developments. Applications Developments where foul drainage by gravity is not possible, including: Domestic sewage pumping; Effluent pumpsets for sewage treatment plants. Features Complete package systems delivered direct to site. Ready for immediate and simple installation. Factory built and quality assured. Maintenance free GRP chambers. High-level alarm fitted as standard. Full after sales maintenance available. Design Package pump systems are supplied with: GRP chambers; Pump(s); High-level alarm (optional fitment on effluent pumpsets); Pre-set automatic level control; Non-return valve; Discharge pipe and all connections. Delivery & Installation Units are normally delivered by flat bed vehicle and cranage facilities should be available on-site for off loading. Installation is quick and economical, the unit requiring only a concrete base and surround. Comprehensive installation instructions are supplied with every unit. Advice The information in this sales literature is, by necessity, brief. For more detailed technical literature and drawings regarding applications, installation, maintenance or specific options, please contact us. We have both internal and field sales staff who will be pleased to assist. Maintenance Clearwater package pump systems are designed for minimum maintenance. Clearwater offers a full after sales service involving planned maintenance visits. Legal Requirements Prior to installation, there is a legal requirement to obtain permission from the appropriate agencies (including connection to a public sewer). Options 1m invert. Lifting eyes. Pedestrian duty cover. Pump Selection Chart Type Invert (m) Model Ref. Single Effluent Pump 1.0 PE1S-IR Twin Effluent Pump 1.0 PE2S-IRA Single Sewage Pump 1.0 PS1S-1G 6

RAINWATER HARVESTING Rainwater harvesting systems for home and garden. HOUSEHOLD APPLICATIONS Clearwater offer a range of simplified rainwater harvesting systems controlled by a pump, suitable for either direct or gravity fed applications. Operation of the system does not require a control panel, display panel or depth sensor. Rainwater harvesting for household non-potable applications Features & Benefits Simplified system design for rapid installation. Quick-start set-up procedure. Kit in a box of key components. Delivered to site on single pallet. Easy conversion to gravity system with optional header tank. Minimal energy use in operation. Designed in accordance with BS 8515. Contact us for advice on selecting the correct size tank for your property s roof area. Rainwater Harvesting System Selection Chart Capacity Model Ref. Gravity Direct 1,200 litres AQB012GB AQB012DB 2,800 litres AQB028GB AQB028DB,800 litres AQB08GB AQB08DB,600 litres AQB06GB AQB06DB GARDEN IRRIGATION Clearwater s Garden Irrigation system comprises of a filter, an underground storage tank and a pump. Rainwater is stored in the underground tank from which it is pumped at a constant pressure to a hose connection point, as required. Garden irrigation Features Pumped water to required application, e.g. garden hose, power washer, sprinkler system. Submersible pump. Internal self-cleaning leaf filter. Benefits Inexpensive and easy to install. Simple on/off operation. Suitable for existing and new homes. Automatic rainwater diversion when tank reaches full capacity. Garden Irrigation System Selection Chart Capacity Model Ref. 2,800 litres RTA02806AAB,800 litres RTA0806AAB,600 litres RTA0606AAB 7

Sewage Treatment Systems Septic Tanks Cesspools and Storage Tanks Pumping Stations Rainwater Harvesting Systems Clearwater Pollution Control Tel: 08 225 051 Fax: 08 225 0516 Email: info@cwpc.co.uk www.cwpc.co.uk Stockist: 80% Cert no. XX-XXX-000000-XX