Dharam V. Punwani President, Avalon Consulting, Inc. Presented at Turbine Inlet Cooling Association Webinar April 9, 2014



Similar documents
Turbine Inlet Cooling

GENERATION TECHNOLOGY ASSESSMENT

GLOBACON 05 HVAC Systems for Cogen

THE EUROPEAN GREEN BUILDING PROGRAMME. Technical Module on Combined Heat and Power

Renewable Technologies

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

CRITICAL COOLING FOR DATA CENTERS

RESOURCE GUIDE Updated: March 2015

GAS TURBINE INLET AIR CHILLING FOR LNG

The Technology and Business of Power Andrew Valencia, P.E. Lower Colorado River Authority

Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle

CHP - The Business Case

Big Buildings lead to big savings

ALONE. small scale solar cooling device Project No TREN FP7EN Project No TREN/FP7EN/ ALONE. small scale solar cooling device

Dallas/Fort Worth International Airport District Energy Plant Upgrades Project Making More with Less Sustainable Communities Conference Dallas, TX

Energy Storage Activities at New York Power Authority

This presentation is posted for public use. ACEEE does not endorse any product or service.

Princeton University Microgrid

SOLEL SUNCOOLER SOLAR-POWERED AIR-CONDITIONING / HEATING SYSTEM

Green Development of Infrastructure and Campus: Modern Practice and Approach in District Heating and Cooling System

COGENERATION. This section briefly describes the main features of the cogeneration system or a Combined Heat & Power (CHP) system. 36 Units.

Study and Comparison of Inlet Air Cooling Technique of Gas Turbines and Their Effects on Increase of the Efficiency and Outlet Power

Gas Absorption Heat Pumps. Future proofing your heating and hot water

GE Energy LMS100. Flexible Power

SGT5-4000F Trusted Operational Excellence

Emissions Comparison for a 20 MW Flywheel-based Frequency Regulation Power Plant

New absorption chillers for high efficient solar cooling systems

Optimization of Water - Cooled Chiller Cooling Tower Combinations

Combined Heat & Power. Discussion with Connecticut Energy Advisory Board. February 23, 2010

Self-benchmarking Guide for Data Center Infrastructure: Metrics, Benchmarks, Actions Sponsored by:

PREVENTIVE MAINTENANCE PROGRAM AND NOVEL TECHNIQUES TO REDUCE DOWNTIME AND INCREASE OPERATING EFFICIENCY AT DISTRIBUTED COGENERATION FACILITIES

Chapter 3.4: HVAC & Refrigeration System

Wet Bulb Temperature and Its Impact on Building Performance

How To Evaluate Cogeneration

RosevilleProject. LoE _ 2 Glass Products. You can reduce your cooling energy usage by 25% or more. Here is the proof.

Building Energy Systems. - HVAC: Heating, Distribution -

A heat pump system with a latent heat storage utilizing seawater installed in an aquarium

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

Design and Test Operation Performance of 1,500 C Class Gas Turbine Combined-Cycle Power Plant:

Evaluation of mobile storage systems for heat transport. G. Storch, A. Hauer, A. Krönauer ZAE Bayern, Walther-Meißner-Str. 6, Garching, Germany

Energy Saving by ESCO (Energy Service Company) Project in Hospital

ANALYSIS OF SOLAR THERMAL POWER PLANTS WITH THERMAL ENERGY STORAGE AND SOLAR-HYBRID OPERATION STRATEGY

Evaporative Cooling for Residential and Light-Commercial

Case Studies of District Cooling Operating and Capital Cost Savings Using Chilled Water and Low Temperature Fluid TES

GEOTHERMAL HEAT PUMP SYSTEMS ARE RED HOT BUT ARE THEY REALLY GREEN?

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Data Center Analysis and Design Analysis of SU s Green Data Center Performance

Performance Monitoring For Gas Turbines

Gas-Fired Power HIGHLIGHTS

INFO HTK. Hybrid dry cooler. The reference for hybrid dry cooling ,000 kw

Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics

TES for Medical Center

Feasibility Study for Mobile Sorption Storage in Industrial Applications

Source: EIA Natural Gas Issues and Trends 1998

SIMULATION OF RADIANT COOLING PERFORMANCE WITH

Your partner of choice for integrated energy solutions

Typical Cooling Load Profile

Physics and Economy of Energy Storage

Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.

Good Practice Form

Half the cost Half the carbon

Energy Strategic Plan Los Angeles Community College District Community College League Conference

Waste Energy Recovery Opportunities for Interstate Natural Gas Pipelines

GAS TURBINE PERFORMANCE UPGRADE OPTIONS

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Large Energy Savings Per Installation VFDs for Large Chillers

How To Reduce Energy Use

Top Technology for Industry, Agriculture, Business and Communities

Drives and motors. A guide to using variable-speed drives and motors in retail environments

CHP Strategies and Options / Stored Energy ENERGY SYMPOSIUM April8, 2014 Reading Country Club

Hybrid Power Generations Systems, LLC

Energy Recovery Systems for the Efficient Cooling of Data Centers using Absorption Chillers and Renewable Energy Resources

DISTRIBUTED GENERATION AND EMERGING TECHNOLOGIES

October 8, WHP Waste Heat-to-Power Fuel and Emission Free Power

Chapters 7. Performance Comparison of CI and SI Engines. Performance Comparison of CI and SI Engines con t. SI vs CI Performance Comparison

2B.1 Chilled-Water Return (and Supply) Temperature B.3 Cooling-Water Supply Temperature / Flow

ENERGY STAR Data Verification Checklist

How To Power A Power Plant With Waste Heat

ABSTRACT DCMCCT PROJECT OVERVIEW

Air Conditioning, Comfort and Energy in India s Commercial Building Sector

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Growing your greenhouse business faster with gas engines.

COMPARISON OF PROCESS FLOWS: FLUID BED COMBUSTOR AND GLASSPACK

Indirect Evaporative Cooling (IDEC) Unit for Data Centers

LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air. Trevor Wende Vice President, Marketing Advantix Systems, Inc.

Coop City Riverbay Corp. Site - Data Integrator Notes

Texas State Capitol Complex:

DATA CENTRE DESIGN AND

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Boilers and cogeneration/trigeneration. Abhi Sawant Business Development Manager Simons Green Energy

David Mezzacappa, P.E. SCS Engineers Contractor to U.S. EPA on LMOP

UTILITIES DEPARTMENT NORTH CAMPUS DISASTER RECOVERY PLAN

DEMONSTRATION OF COMBINED HEAT AND POWER TECHNOLOGY AT A DATA CENTER

Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

New technical solutions for energy efficient buildings

University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Benefits of Water-Cooled Systems vs. Air-Cooled Systems for Air-Conditioning Applications

Solid Oxide Fuel Cell Gas Turbine Hybrid Power Plant. M. Henke, C. Willich, M. Steilen, J. Kallo, K. A. Friedrich

Transcription:

Dharam V. Punwani President, Avalon Consulting, Inc. Presented at Turbine Inlet Cooling Association Webinar April 9, 2014

Background: What is the problem that needs a solution? What is Turbine Inlet Cooling (TIC)? TIC Technologies Economic Benefits of TIC Environmental Benefits of TIC Factors Affecting the Performance of TIC Technologies Factors Affecting the Economics and Selection of TIC Technology Summary of the Presentation

Price of electric energy for the ratepayers goes up during the peak demand period: as much as 7 times that during the offpeak period

1 0.9 0.8 0.7 0.6 0.5 0.4 SCE PG&E SDG&E 12 :0 0 2: AM 00 4: AM 00 6: AM 00 8: AM 00 10 AM :0 0 12 AM :0 0 2: PM 00 4: PM 00 6: PM 00 8: PM 00 10 PM :0 0 PM 0.3 Y-Axis Unit: CO2 Emissions, lbs/kwh (California) Source: Scot Duncan Presentation at ASHRAE June 2007

During hot weather, just when power demand peaks, 1. Power output decreases Up to 35% below rated capacity Extent of the decrease depends on the CT design 2. Efficiency decreases leading to increased fuel consumption (higher heat rate) and increased emissions per kwh Up to 15% below rated capacity Extent of the decrease depends on the CT design

EFFECTS OF COMPRESSOR INLET AIR TEMPERATURE ON GAS TURBINE POWER OUTPUT 105% % OF RATED POWER PERIOD OF GREATEST DEMAND Up to 19% capacity loss at peak demand for this CT 100% 95% ISO DESIGN POINT 90% OLD "FRAME" POWER OUTPUT Compression Ratio = 10 NEW AERO-DERIVATIVE POWER OUTPUT Compression Ratio = 30 85% 80% 50 55 60 65 70 75 80 85 90 COMPRESSOR INLET AIR TEMPERATURE, degrees F 95 100

Heat Rate, Percent of Design 105 104 Aeroderivative 103 102 Frame Fuel Use Increase (i.e. Energy Efficiency loss) at peak demand 101 100 99 98 97 40 50 60 70 80 Ambient Dry-Bulb Temperature, F 90 100

Efficiency loss of over 8 % from HR of ~ 11,100 to ~12,000 Btu/kWh Capacity Loss of over 21% from ~10,750 kw to ~8,500 kw Source: Solar Turbines

Fuel Winter Capacity, MW Summer Capacity, MW Summer Capacity Loss, MW Petroleum 60,878 56,781 4,097 Natural Gas 432,309 401,272 31,037 Source: U.S. Department of Energy s Energy Information Agency 2012 Database * Most of it is due to the reduced capacity of combustion turbine

Power output of a turbine is proportional to the mass flow rate of hot gases it receives from the combustion section Mass flow rate in the combustion section is proportional to the mass flow rate of the compressed air it receives from the compressor Mass flow rate capacity of a compressor is limited by its volumetric capacity for sucking in the inlet air Increase in ambient temperature reduces the air density that decreases the mass for the same volumetric flow rate through the compressor Reduced mass flow rate of compressed air reduces the mass flow rate of the hot combustor gases that leads to reduced power out put of the combustion turbine

Compressor power requirement increases with increase in air temperature Compressor of a CT system consumes almost two-third of the turbine s gross output Increased power required of the compressor reduces the net electric power available from the CT system

Cooling the inlet air before it enters the compressor or during its compression

Direct Evaporation - Wetted Media, Fogging Indirect Evaporation Chilled Fluid using mechanical or absorption chillers: - Indirect or Direct Heat Exchange 16

Thermal Energy Storage (TES) - Chilled Fluid or Ice Wet Compression LNG Vaporization Hybrid - Some combination of two or more cooling technologies Last year TICA completed a series of webinars on each technology. 17

Each TIC technology has its pros and cons No one technology is best for all applications Evaporative cooling systems can not cool the inlet air to lower than the wet-bulb temperature but require least capital cost and have least parasitic power need Chiller systems can be designed to cool the air to any desired temperature but require more capital cost and have high parasitic power need

TES systems shift chiller parasitic load to offpeak period Wet compression improves compression efficiency and low parasitic load Hybrid systems minimize the parasitic load to achieve a desired inlet air temperature LNG vaporization only applicable where the power plant is located at/or need an LNG vaporization facility

Thousands of plants already benefiting from TIC TICA web site database of 100+ plants worldwide that are using TIC www.turbineinletcooling.org/database.html

Available on the TICA Website http://www.turbineinletcooling.org/calculation_n onmem.php5 Member Version (Full Version) Public Version (Partial Features)

TIC Technology CT Design Characteristics Weather Data (dry-bulb and coincident wet-bulb temperatures/humidity) for the Geographic Location of the CT Design Ambient Conditions Design Cooled Air Temperature (if allowed by the TIC technology)* * Cooling achieved by evap technologies is limited by the humidity

Increased Capacity Increased Efficiency Reduced Emissions Reduced Unit Capital Cost ($/kw of capacity increase)

Net Output Enhancement, MW 60 56 95F DB and 80F WB 49 52 55 95F DB and 60F WB 50 43 41 Combined-Cycle System: Two 501FD1 and one ST 40 30 20 19 18 10 Wetted Media Fogging Electric Chiller Wet Compression Sources: Wet Compression: Caldwell Energy, Inc. All Others : D.V. Punwani Presentation, Electric Power 2008

Reduces on-site emissions* by increasing the efficiency of the turbine being cooled Reduces grid-wide emissions* by reducing the need for operating less-efficient and higher-emission power plants * lb/kwh of all emissions including, CO2, NOx, Sox

7FA in Combined Cycle (1 Gas Turbine and 1 Steam Turbine) Las Vegas, NV (108oF and 8.6% RH): Solid Anniston, AL (95oF and 42.5 RH): Shaded Cooled Air Temperatures: Wetted-Media Chiller Las Vegas, NV 70.3 50F Anniston, AL 77.9 50F

7FA in Combined Cycle (1 Gas Turbine and 1 Steam Turbine)

Example TIC on a nominal 500 MW CC plant eliminates the need for siting a new or operating an existing 75-95 MW SC peaker - Eliminates costs associated with siting, construction and interconnections of a new plant - Reduce long lead time for a new plant (TIC requires <1yr)

(316 MW Cogeneration Plant Near Houston, TX) Evaporative Cooling is a Wetted Media system Single-Effect and Double-Effect Refer to Absorption Chillers Source: D.V. Punwani et. al. Presented at ASHARE 2001

TIC Technology Annual Operating Hours CT Characteristics 8,760 Hours Annual Weather Data for the Geographic Location of the CT Market Value of the Additional Electric Energy Produced Fuel Cost

Capacity Enhancement Capital Cost, $/MW 1,000,000 832,941 800,000 600,000 400,000 183,421 200,000 15,660 14,797 95,215 No Cooling Wetted Media Fogging Wet Electric Chiller Compression 317 MW Cogeneration System Snapshot at 95oF DB and 80oF WB Source: Punwani et al ASHRAE Winter Meeting, January 2001

7FA in Combined Cycle (1 Gas Turbine and 1 Steam Turbine) Las Vegas, NV (108oF and 8.6% RH) 317 MW Cogeneration System Snapshot at 95oF DB and 80oF WB Source: Punwani et al ASHRAE Winter Meeting, January 2001

Generates more MWh during peak demand periods when electric energy value is high Reduces capital cost per unit of the increased generation capacity compared to new power plants Reduces fuel cost of electric energy generation compared to the low energy efficiency peakers Reduces cost for ratepayers by potentially lower capacity payments to be provided by the independent system operators (ISOs) to power producers

Regulators should recognize TIC is a valuable solution to their supply problem during hot weather and Use the full potential of existing combustion turbine plants Require TIC use before allowing construction of new capacity Ensure capacity payments provide appropriate returns for systems using TIC Policymakers should recognize the value of TIC for reducing emission and Exempt the TIC from environmental re-permitting Create incentives for plant owners to use TIC technology

Turbine Inlet Cooling Significantly increases CT power output during hot weather Multiple options of commercially-proven technologies are available Generally economically attractive for the plant owners and rate payers Helps reduce emissions and thus, good for the environment

June 11, 2014: Wetted-Media Evaporative Cooling August 13, 2014: Fogging October 8, 2014: Chiller Systems December 12, 2014: Thermal Energy Storage February 11, 2015: Wet Compression April 8, 2015: Hybrid Systems

Dharam V. Punwani dpunwani@avalonconsulting.com 1-630-983-0883