ENVIRONMENTAL TESTING & MONITORING: Deciphering Compliance Requirements for Pharmaceutical and Medical Device Manufacturers A WHITE PAPER



Similar documents
The use of risk assessment tools for microbiological assessment of cleanroom environments. by Tim Sandle

Qualification of an Environmental Monitoring Program

THE MICROBIAL ID BREAKTHROUGH: How DNA Sequencing Services Help Prevent Catastrophic Cleanroom Shutdowns

Manufacturing. Environmental Monitoring Particle Counts Are Easy B IOP ROCESSTECHNICAL. Scott E. Mackler

Particle Monitoring Requirements in Pharmaceutical Cleanrooms

Risk-Based Environmental Monitoring. Marsha Stabler Hardiman Senior Consultant Concordia ValSource Wednesday September 17, 2014 FDA/PQRI

DRAFT GUIDANCE. This guidance document is being distributed for comment purposes only.

Sterile Cleanroom Management

Environmental Monitoring

Medical Device Packaging and Sterilization: What you need to know to protect your product

TSI BIOTRAK REAL-TIME VIABLE PARTICLE COUNTER FACILITY MONITORING SYSTEMS

On-Site GMP Training GMP COMPLIANCE TECHNICAL

ENVIRONMENTAL MONITORING

Raleigh, NC May 12 th & 13 th Meeting The New ISO Cleanroom Standards And Changing EU Guidance How Will You Comply?

GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE OF STERILE MEDICINAL PRODUCTS

Design, Construction, Commission, and Qualification of Critical Utility Systems: Part III

Environmental Monitoring of Clean Rooms

Practical Series Seminars and Workshops INTENSIVE TRAINING IN ENVIRONMENTAL MONITORING, DISINFECTANT QUALIFICATION AND CLEANROOM CONTAMINATION CONTROL

Cleanroom. For. Sterile Manufacturing Facilities

Gamma Sterilisation Validation according to ISO Sterilising dose -

Risk Based Environmental Monitoring (EM) and EM Data Management and Trending

Basic Requirements For Aseptic Manufacturing Of Sterile Medicinal Products A Comparison Between Europe And USA

Regulations Concerning

Understanding USP 797

FDA and the Compounding Pharmacy

Workflow System for Paperless Air Monitoring Powered by MODA. Presented by

USP <797> Cleanroom Design and Environmental Monitoring. Andrew King, USP <797> Specialist CETA Member RCCP-SC

CLASSIFICATION OF CLEANROOMS

The Microbial Bioburden of USP 797 Compliance. Simplifying Environmental Quality and Control Practices for Pharmaceutical Compounding

New changes to cleanroom & clean air device classifications: ISO & 2

Everything you want to know about USP 797

CLEAN ROOM MONITORING REGULATORY STANDARDS

Environmental Monitoring Risk Assessment

Building the Business Case for Automated Rapid Testing: Translating the benefits of rapid automated microbial testing into dollars saved

patient safety A commitment to GE Healthcare

Cleaning Validation in Active pharmaceutical Ingredient manufacturing plants

ANALYTICAL OUTSOURCING WHY SHOULD YOU OUTSOURCE?

Validating and Monitoring the Cleanroom

Terminal Sterilization. vs. Aseptic Processing

White Paper. The Gap Between LIMS Capabilities and Environmental Monitoring Needs. Abstract. The Environmental Monitoring Workflow

Cleaning. By the end of this chapter, you will be able to: Introduction. Definitions. Chapter 9

Library Guide: Pharmaceutical GMPs

The Perfect Partnership for GMP Cleaning Services. Total Cleaning Solutions from Micronclean & Isocleanse

Hazardous Drug. Cleanroom. Standards

Auditing as a Component of a Pharmaceutical Quality System

To be taught at the Ausia Biotech Aseptic Training Center in Hangzhou China

Pharmagraph. GMP/GLP Monitoring System

ISO A Standard Methodology to Optical Particle Counter Calibration and What It Means to Cleanroom Owners

Guidance for Industry

PEOPLE > SCIENCE > SOLUTIONS

The Financial Benefits of the MicroSEQ Microbial Identification System

SERVICES FOR. Devices and Combination Products

Cord Blood Licensure. Session 2C: Advanced Cell Therapies April 11, 2013

Pharmaceutical Companies: Outsourcing Combination Product Manufacturing. Phillips-Medisize Corporation October 2010

EU GMP Annex 1 Update 2008: Airborne Particle Counting

VALIDATION OF ASEPTIC PROCESSES

INTEGRATING COMPLIANCE, CLEANLINESS, AND SAFETY IN CONTROLLED ENVIRONMENTS CONTROLLED ENVIRONMENTS MANAGEMENT SERVICES

DISCUSSION TOOL PRESENTED TO THE AABB CT REGULATORY AFFAIRS SUBSECTION

Preparing for the Pre-Approval Inspection What to do Before the FDA Arrives. Barry A. Friedman, Ph.D. Consultant

EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL. EudraLex The Rules Governing Medicinal Products in the European Union

On-Site GMP Training GMP COMPLIANCE TECHNICAL

The Environmental Monitoring Program In a GMP Environment

Air and Water Balancing - Sound and Vibration Testing - Cleanroom Services - Building Commissioning Building Envelope Testing Thermal Imaging

Process Validation Guidance Requirements (FDA and EU Annex 15: Qualification and Validation)

Annex 6 WHO good manufacturing practices for sterile pharmaceutical products

Guidance for Industry Quality Systems Approach to Pharmaceutical CGMP Regulations

Media fills Periodic performance qualification (Re-Validation)

International Standard ISO 14644

How CMOs are Turning Their Training Programs into Market Differentiators

RE: Comments on USP 800 Hazardous Drugs Handling in Healthcare Settings

PERFORMANCE QUALIFICATION OF A CLEAN ROOM FROM A QUALITY PERSPECTIVE

Environmental Monitoring

Managing Compliance Risks with EAM / CMMS

Open Microphone Meeting:

Mycoplasma Testing Products & Services. M-175 CELLshipper Mycoplasma Detection Kit (In-house sample preparation and slide fixation)

Guidance for Industry: Starting Material Supplier Management

CONCEPTS OF FOOD SAFETY QUALITY MANAGEMENT SYSTEMS. Mrs. Malini Rajendran

Quality risk management and the economics of implementing rapid microbiological methods

Quality Management System MANUAL. SDIX, LLC Headquarters: 111 Pencader Drive Newark, Delaware 19702

Quality Management System MANUAL. SDIX, LLC Headquarters: 111 Pencader Drive Newark, Delaware 19702

Particle Counting and Environmental Monitoring In Pharmaceutical / Life Sciences

EXPANDING OPPORTUNITIES WITH

Pharmaceutical Wholesaler Site Inspection Checklist

Interactive Response Technologies

Monitoring. Compliant and Reasonable. 5-6 May 2015, Berlin, Germany

Biological Indicators and

Steam Sterilization and the 2007 Revision of PDA Technical Report 1

Guidance for Industry Circumstances that Constitute Delaying, Denying, Limiting, or Refusing a Drug Inspection

Rules for Compounded Sterile Preparations (CSPs)

USP Guidances on Environmental Control including related USP, FDA, EMEA & PDA Activities. James Agalloco Agalloco & Associates

Monitoring the autoclaving process in the pharmaceutical industry

Annex 2. WHO good manufacturing practices for pharmaceutical products: main principles 1

SPECIFICATIONS AND CONTROL TESTS ON THE FINISHED PRODUCT

Design, Operation and Management of GTP/GMP Cell Engineering Facilities

Fly. Wealth and Retirement IT Hosting

Overview of Medical Device Design Controls in the US. By Nandini Murthy, MS, RAC

One Detection Technology. Three Applications. One Automated Platform.

Department of Food Science Food Processing FSE98(10-99)

Transcription:

A WHITE PAPER ENVIRONMENTAL TESTING & MONITORING: Deciphering Compliance Requirements for Pharmaceutical and Medical Device Manufacturers By Scott Mackin

A WHITE PAPER ENVIRONMENTAL TESTING & MONITORING: Deciphering Compliance Requirements for Pharmaceutical and Medical Device Manufacturers Scott Mackin ABSTRACT Industrial sterilization and contamination control programs are critical in pharmaceutical and medical device manufacturing. This article reviews the key elements of a best practice environmental testing program, including sterilization standards, FDA requirements, and the critical factors in maintaining controlled environments. In this paper, the author draws on his extensive experience assisting clients with program development. He reviews strategies that range from the essentials of compliance to budget development and management. CHALLENGES FACING MANUFACTURERS JUST WHAT IS REQUIRED? Having assisted scores of medical device manufactures in designing, implementing, and maintaining both their sterilization and environmental monitoring programs, we have found that the biggest challenge for the manufacturer is determining what exactly is required for compliance. For parenteral manufacturers, the environmental control parameters are highly stringent. The collaborative effort between the Office of Compliance in the Center for Drug Evaluation and Research (CDER), the Center for Biologics Evaluation and Research (CBER), and the Office of Regulatory Affairs (ORA) has produced and continues to develop the guidance for industry Sterile Drug Products Produced by Aseptic Processing Current Good Manufacturing Practice [1]. While the primary focus of the guidance is on cgmps in 21 CFR 210 and 211, considerable attention has been given to environmental control. USP <1116> Microbiological Evaluation of Clean Rooms and Other Controlled Environments [2] also offers these manufacturers guidance that can be used as a framework for development of programs for personnel training and environmental monitoring. The informational chapter also reviews guidelines, equipment, and statistical methods which have been adopted as industry standard. The PDA TR13 Fundamentals of a Microbiological Environmental Monitoring Program document is also a mainstay and offers solid guidance to all categories of manufacturers. Conversely, device manufacturers have historically been forced to piece together a coherent and defensible strategy by choosing bits and pieces from an array of different standards, guidance documents, and corporate policies. For anyone other than a device manufacturing veteran, the task is daunting, and many times there is no concrete program implemented. Frequently, when programs are implemented, there is little confidence in their practicality or regulatory muster. When production operators do not buy into the value of the program, it often transitions to a system of documenting control failure rather than a program that demonstrates continued control and compliance. Drift from a state of control at any point within the program will likely negatively impact the entire system ultimately resulting in loss of production. Typically, larger companies will already have solid programs in place for commissioning new production areas, continued monitoring, and sterilization validation. Additionally, since many of these companies are experienced in satisfying a variety of regulatory environments to market their products globally, their programs tend to be more comprehensive. Fortunately for Microtest, the quantity and range of controlled environments, and the associated variety of activities they are used for, has given us an advantage in continued improvement to associated systems. We have a unique understanding of a wide range of regulatory environments and applications, enabling us to seamlessly identify and respond to the day-to-day challenges encountered by our staff and clients. 1.

PARTICULATE CHARACTERIZATION: VIABLE VS. NON-VIABLE Since the early days of Federal Standard 209 (FS 209), cleanliness classes have been assigned to clean zones using measured levels of non-viable particulates. Initially, microbiologists and regulatory professionals struggled to draw some correlation between the levels of non-viable particles and viable particles present in the environment. But a general consensus was reached acknowledging that no direct relationship could be defined. However, because of the relative ease and practicality of continuous monitoring for non-viables it remains the most reliable method for real-time assessment of environmental control. For anything other than the Class 100 (ISO Class 5) area, determining what satisfies the microbial sampling requirement called out in many standards is often an ambiguous matter. There are no commonly accepted levels of environmental bioburden, especially in Class 10,000 (ISO Class 7) and 100,000 (ISO Class 8) areas. Since FS 209 has been sunset and the ISO 14644 series of documents have taken its place, ISO 14644 [3] is currently recognized as the worldwide standard for designing and validating controlled environments. The drafting of the ISO 14698 [4] series of documents has provided manufacturers with concrete guidance in setting up the microbial portions of their programs. Still, the ISO 14698 (microbial) document stops short of providing a definitive method for determining just how much microbial sampling is sufficient. Many manufacturers elect to utilize the same calculation for their microbial sampling that is set forth in 14644 to sample for non-viable particulate. Even so, this still leaves the questions of what sample locations in the environment are most critical and what type of organisms (aerobic, anaerobic, fungal) must be recovered. This is open to interpretation and written justification must be provided in the overall environmental monitoring plan. Unfortunately, as sterilization validation programs rely more and more upon bioburden control and monitoring, this missing piece becomes even more critical. At Microtest, we have been fortunate to have the opportunity to collect and analyze volumes of data that correlate environmental bioburden, product contamination, and sterilization efficacy. Our off-site Environmental Services group has encountered virtually every type of manufacturing scenario imaginable. From Class 5 Fill/Finish lines to extruding, to non-wovens, to packaging our clients benefit from Microtest s understanding of program development for cleaning, qualifying, monitoring, and training in any environment. SAMPLE PLANS: WRITTEN JUSTIFICATION VS. SELECTING SAMPLE FREQUENCIES AND VOLUMES FROM GUIDANCE DOCUMENTS Regulatory agencies almost always prefer to defer to a table or calculation for determining these parameters. They provide a comfort factor. It s reassuring to point to a document during an audit. Often the manufacturer must design an environmental sampling scheme by identifying critical areas of product contact or manufacturing activities. The tendency is to err on the side of over-sampling. At first glance, this sounds like an easy solution. But for many manufacturers, it is simply not a feasible approach with respect to budgetary or personnel resources. The expense associated with purchasing, validating, and maintaining sampling equipment, plus buying supplies and training personnel often is prohibitive. Especially since many sampling schemes and/or control parameters are verified somewhat infrequently, such as quarterly or semi-annually as set forth in ISO 14644 [5] (especially in Class 100,000 (ISO Class 8) areas). For manufacturers in this group, especially smaller companies and start ups, it makes sense to outsource. There is an attractive opportunity to draw on resources and expertise that would be too expensive to staff internally. VALIDATION: CONTROLLING COST AND VALIDATION DATA Microtest has developed innumerable monitoring programs, internally and for clients, that are both fiscally reasonable and pass regulatory muster. The nature of our business models gives us the opportunity to continually improve through client audits of our facility. In a way, we have been able to collect our customers input and construct a program that emulates the best of what all of their programs have to offer. This gives our clients a great opportunity to leverage the sum of our learning. We know what works and we know what is cost effective. Consider that before a room is commissioned, it s necessary to plan for collection of data required for validation, as well as the source for that data 1. Vendor responsibilities and agreements need to be clearly 1 ISO 14644 [6] offers an overview of important parameters of performance. It also provides guidance including requirements for start-up and qualification. 2.

defined, managed, and documented to avoid costly retesting. For example, during HEPA filter installation, most vendors will scan the filters and seals for leaks. We are often asked to perform this service when it has already been done, adding time and expense. Having a clear understanding of the regulatory requirements and managing vendor activities effectively will shorten project timelines, reduce expenses and get production going. ISO 14644 [6] offers an overview of important parameters of performance. It also provides guidance including requirements for start-up and qualification. Microtest is able to streamline the entire process for our customers by combining expertise with a wide range of services. We offer a tried-and-true approach that minimizes the time and stress involved with project management and completion. CASE STUDY: STERILIZATION METHOD SELECTION - COORDINATING MULTIPLE PROGRAMS This is probably the most common example of how environmental control can impact other programs in an organization. The method of selecting the most appropriate environmental monitoring and terminal sterilization programs should not only be a function of product materials (gamma vs. EO); it should also take the level and nature of both the environmental and product bioburden into account. Indeed there seems to be a growing awareness among device manufacturers that there is an important relationship between their environmental monitoring and sterilization programs. This is especially true given the rising popularity of using the VDmax method for sterilizing products. In fact, ISO 11137 [7], 11737 [8], 13409 [9], and TIR 33 [10] all refer to the need to have an environmental monitoring program in place. The VDmax [11] method for sterilization validation and control was developed by major companies in the industry. These were large, well established manufacturers with numerous historical data regarding the normal ranges of environmental and product bioburden. It was easy to document justification for using the newer method, since they could review the trends and had a good understanding of what could be considered a state of control. Experienced manufacturers could feel confident that the environmental programs they had in place were sufficient to support product bioburden control, reducing the potential of verification dosing failures. Today, we are seeing more and more start-ups and component manufacturers using the VDmax method on new product validations. IMPACT ON COST The above example of VDmax program integration reduces the amount of product required during quarterly dose audit testing, which in turn reduces the annual cost of product release testing. This makes the method especially attractive to start-up manufacturers. However, the method is not always the best fit for every manufacturer, especially for companies with limited experience with controlling bioburden. AAMI TIR 33-2005 clearly states that this method cannot be used when the estimated average bioburden for product is >1000 cfu. Cost and/or product savings can also quickly vanish during quarterly audits if problems due to high bioburden are encountered. It s important to remember that the verification dose is performed at an SAL [12] of 10-1, and on a statistically smaller sample set. An influx of unobserved resistant organism can ultimately result in retests, if not revalidation to another method, even in situations where the bioburden count itself did not increase over historical levels. This makes understanding the nature of the typical bioburden as important as the levels themselves. Trending seasonal bioburden variations and identifying in-house isolates are two examples of how to gain this understanding. For situations such as these, Microtest s qualification of its MicroSeq system for microbial identification has proven invaluable. It is fast and cost effective obvious advantages when considering resolution of environmental excursions. CRITICAL FACTORS There are a number of other factors not always obvious to manufacturers that are an integral part to any bioburden control. Raw Materials: Precautions should be taken to ensure that external bioburden does not travel into production areas along with components and materials. These materials should typically be removed from their original shipping containers, cleaned, and stored for staging in controlled areas within or adjacent to manufacturing 3.

suites. For example, every effort should be made to reduce or eliminate cardboard and paper products from the controlled environment. Process flow should be clearly defined and qualified. Adhering to the plan helps to avoid surprises and dealing with unknowns. Personnel Activities and Hygiene: There should be written and posted procedures for support of operations regarding proper gowning, hand washing, and basic microbiological principles involved in minimizing contamination from manufacturing personnel and their activities. Microtest has great experience performing smoke studies to correlate airflow concepts as simple as placement of equipment and personnel and the risk of product contamination. We also commonly help clients put together protocols with pictures from smoke studies for subsequent use in personnel training. Training documentation should be in place for all personnel who will work in the manufacturing area. For example, it is common to require manufacturing personnel to execute some type of gowning validation, using touch plates or swabs, before they are deemed competent to work in the controlled environment. An understanding of what types of house garments are appropriate to the specific activities and environment is important as well. This issue can impact cost and operator performance as well as environmental bioburden. Housekeeping: Similar to personnel hygiene, there should be written and posted housekeeping procedures and training documentation. Close attention should be paid to cleaning materials such as mop heads and disinfectants, frequency of cleaning, and documentation of cleaning activities. Microtest has worked with most commercially available disinfectants with respect to cleaning, disinfectant validation, and challenging in-house isolates. We have assisted scores of companies with cleaning efficacy studies, disinfectant rotation programs, and use-dilution expiry. SUMMARY Unfortunately, there is not yet a single reference document for manufacturers to rely upon to design, validate, and demonstrate room class compliance. It s not likely that one will be drafted any time soon. As anyone who s been involved in the validation and monitoring process knows, the task would be monumental. The ISO 14644 series and the ISO 14698 documents have eased the task enormously and are indispensable resources for manufacturers of terminally sterilized products. The key is to keep in mind at all times that the issue is all about bioburden. We must step back and look at the manufacturing process, people, and environment as a whole when drafting our validation programs. By defining traffic patterns and identifying and limiting product and personnel contact areas, we can attain a solid understanding of bioburden. Characterizing, controlling, and understanding environmental bioburden levels and trends are the cornerstones to defining and implementing a solid environmental monitoring program which fully supports sterilization validation and release activities. 4.

About Microtest Microtest is a leader in testing services and contract manufacturing for medical devices, pharmaceuticals, and biotechnology. Founded in 1984, the company s expertise and flexible processes enhance product safety and security, speed time to market, and minimize supply chain disruption. Mictrotest s unique single-source capability to provide testing and manufacturing solutions allows the company to support a full pharmaceutical or medical device product release. Our facilities in Agawam, Massachusetts, include state-of-the-art aseptic manufacturing areas; analytical chemistry, microbiological, and virological laboratories; Class 100 clean rooms; onsite steam and ethylene oxide sterilization, plus depyrogenation capabilities; purified water systems; and voice/data systems. About the Author Scott Mackin is a Project Manager at Microtest Laboratories Inc., He can be reached at 413-786-1680 or at smackin@microtestlabs.com. References 1 Guidance for Industry, Sterile Drug Products Produced by Aseptic Processing Current Good Manufacturing Practices 2 USP <1116>, Microbiological Evaluation of Clean Rooms and Other Controlled Environments 3 ISO 14644, Cleanrooms and associated controlled environments: Part 1: Classification of air cleanliness 4 ISO 14698, Cleanrooms and associated controlled environments: Part 1: Biocontamination Control General Principles and Methods 5 ISO 14644, Cleanrooms and associated controlled environments: Part 2: Specifications for testing and monitoring to prove continued compliance with ISO 14644-1 6 ISO 14644, Cleanrooms and associated controlled environments: Part 4: Design, construction and start-up 7 ISO 11137-1:2006 Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices 8 ISO 11737-3:2004, Sterilization of medical devices: Microbiological methods: Part 3: Guidance on evaluation and interpretation of bioburden data 9 ISO/TS 13409:2002, Sterilization of health care products: Radiation sterilization: Substantiation of 25 kgy as a sterilization dose for small or infrequent production batches 10 AAMI TIR33:2005 Sterilization of health care products Radiation Substantiation of a selected sterilization dose Method VDmax 11 VDmax: Maximum acceptable verification dose for a given bioburden and verification dose sample size. 12 Sterility Assurance Level: The probability of a microorganism being present on a product unit after sterilization www.microtestlabs.com 1-800-631-1680 1-413-786-1680 fax: 1-413-789-4334 Microtest Laboratories, Inc. 104 Gold St P.O. Box 848 Agawam, MA 01001 Microtest is a trademark of Microtest Laboratories, Inc. All other brands may be trademarks of their respective holders. 2007 Microtest Laboratories, Inc. All rights reserved. Printed in U.S.A. 0750504 4/07 5.