EARTH PRESSURE AND HYDRAULIC PRESSURE



Similar documents
Worked Example 2 (Version 1) Design of concrete cantilever retaining walls to resist earthquake loading for residential sites

Module 7 (Lecture 24 to 28) RETAINING WALLS

Drained and Undrained Conditions. Undrained and Drained Shear Strength

REINFORCED CONCRETE. Reinforced Concrete Design. A Fundamental Approach - Fifth Edition. Walls are generally used to provide lateral support for:

PART TWO GEOSYNTHETIC SOIL REINFORCEMENT. Martin Street Improvements, Fredonia, Wisconsin; Keystone Compac Hewnstone

DESIGN SPECIFICATIONS FOR HIGHWAY BRIDGES PART V SEISMIC DESIGN

Earth Pressure and Retaining Wall Basics for Non-Geotechnical Engineers

Figure CPT Equipment

c. Borehole Shear Test (BST): BST is performed according to the instructions published by Handy Geotechnical Instruments, Inc.

Numerical Simulation of CPT Tip Resistance in Layered Soil

Load and Resistance Factor Geotechnical Design Code Development in Canada. by Gordon A. Fenton Dalhousie University, Halifax, Canada

Soil Strength. Performance Evaluation of Constructed Facilities Fall Prof. Mesut Pervizpour Office: KH #203 Ph: x4046

ESTIMATION OF UNDRAINED SETTLEMENT OF SHALLOW FOUNDATIONS ON LONDON CLAY

vulcanhammer.net This document downloaded from

DYNAMIC RESPONSE OF CONCRETE GRAVITY DAM ON RANDOM SOIL

Appendix A Sub surface displacements around excavations Data presented in Xdisp sample file

VERTICAL STRESS INCREASES IN SOIL TYPES OF LOADING. Point Loads (P) Line Loads (q/unit length) Examples: - Posts. Examples: - Railroad track

4.3 Results Drained Conditions Undrained Conditions References Data Files Undrained Analysis of

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars

EN Eurocode 7. Section 10 Hydraulic Failure Section 11 Overall Stability Section 12 Embankments. Trevor L.L. Orr Trinity College Dublin Ireland

SEISMIC DAMAGE ESTIMATION PROCEDURE FOR WATER SUPPLY PIPELINES

K x ' Retaining. Walls ENCE 461. Foundation Analysis and Design. Mohr s Circle. and Lateral Earth. Pressures. Lateral Earth Pressure.

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing

PDCA Driven-Pile Terms and Definitions

Open channel flow Basic principle

Chapter 2. Derivation of the Equations of Open Channel Flow. 2.1 General Considerations

ENCE 4610 Foundation Analysis and Design

Cone Penetration Testing in Geotechnical Practice. Tom Lunne Peter K. Robertson John J.M. Powell

CHAPTER 9 CHANNELS APPENDIX A. Hydraulic Design Equations for Open Channel Flow

INTRODUCTION TO SOIL MODULI. Jean-Louis BRIAUD 1

When to Use Immediate Settlement in Settle 3D

SEISMIC DESIGN OF HIGHWAY BRIDGES

EVALUATION OF SEISMIC RESPONSE - FACULTY OF LAND RECLAMATION AND ENVIRONMENTAL ENGINEERING -BUCHAREST

Chapter 11 Equilibrium

Important Points: Timing: Timing Evaluation Methodology Example Immediate First announcement of building damage

Swedge. Verification Manual. Probabilistic analysis of the geometry and stability of surface wedges Rocscience Inc.

Reinforced Concrete Design

SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT

Module 5 (Lectures 17 to 19) MAT FOUNDATIONS

CHAPTER 2 HYDRAULICS OF SEWERS

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

DIRECT SHEAR TEST SOIL MECHANICS SOIL MECHANICS LABORATORY DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF MORATUWA SRI LANKA

Analysis of Retaining Wall Subjected to Earthquake Loading

SEISMIC SETTLEMENT OF SHALLOW FOUNDATIONS

CE 366 SETTLEMENT (Problems & Solutions)

Washington ,

CH. 2 LOADS ON BUILDINGS

Evaluation of Post-liquefaction Reconsolidation Settlement based on Standard Penetration Tests (SPT)

Physics Notes Class 11 CHAPTER 3 MOTION IN A STRAIGHT LINE

METHODS FOR ACHIEVEMENT UNIFORM STRESSES DISTRIBUTION UNDER THE FOUNDATION

Program COLANY Stone Columns Settlement Analysis. User Manual

Soil Mechanics. Outline. Shear Strength of Soils. Shear Failure Soil Strength. Laboratory Shear Strength Test. Stress Path Pore Pressure Parameters

A study on the causes of troubles in shield tunneling site with numerical analysis

Fric-3. force F k and the equation (4.2) may be used. The sense of F k is opposite

Soil Mechanics SOIL STRENGTH page 1

Period #16: Soil Compressibility and Consolidation (II)

Secondary Consolidation and the effect of Surcharge Load

Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur

When the fluid velocity is zero, called the hydrostatic condition, the pressure variation is due only to the weight of the fluid.

STRUCTURAL DAMAGE OF A 5-STOREY BUILDING: DIFFERENTIAL SETTLEMENT DUE TO CONSTRUCTION OF AN ADJACENT BUILDING OR BECAUSE OF CONSTRUCTION DEFECTS?

Copyright 2011 Casa Software Ltd. Centre of Mass

INDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode

DEVELOPMENT AND APPLICATIONS OF TUNED/HYBRID MASS DAMPERS USING MULTI-STAGE RUBBER BEARINGS FOR VIBRATION CONTROL OF STRUCTURES

Seismic Analysis and Design of Steel Liquid Storage Tanks

MITIGATION OF EARTHQUAKE INDUCED GEOTECHNICAL DISASTERS USING A SMART AND NOVEL GEOMATERIAL

IMPROVING THE STRUT AND TIE METHOD BY INCLUDING THE CONCRETE SOFTENING EFFECT

MECHANICS OF SOLIDS - BEAMS TUTORIAL 2 SHEAR FORCE AND BENDING MOMENTS IN BEAMS

ANNEX D1 BASIC CONSIDERATIONS FOR REVIEWING STUDIES IN THE DETAILED RISK ASSESSMENT FOR SAFETY

NOTES on the CONE PENETROMETER TEST

Seismic Risk Prioritization of RC Public Buildings

6 RETROFITTING POST & PIER HOUSES

EUROCODE 7 & POLISH PRACTICE

PREDICTING THE HYDRAULIC CONDUCTIVITY OF MAKASSAR MARINE CLAY USING FIELD PENETRATION TEST (CPTU) RESULTS

THE REPORT ON THE INVESTIGATION OF THE REACTORS AT FUKUSHIMA DAIICHI NUCLEAR POWER STATION (NO. 1)

COSMOS 2012: Earthquakes in Action COSMOS 2012

Dimensional and Structural Data for Elliptical Pipes. PD 26 rev D 21/09/05

SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission.

CONE PENETRATION TESTING AND SITE EXPLORATION IN EVALUATING THE LIQUEFACTION RESISTANCE OF SANDS AND SILTY SANDS ABSTRACT

MODULE VII LARGE BODY WAVE DIFFRACTION

CHAPTER III GRAVITY DAMS. (Revised October 2002)

Hydraulics Laboratory Experiment Report

CHAPTER: 6 FLOW OF WATER THROUGH SOILS

NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES

THE DEVELOPMENT OF DESIGN METHODS FOR REINFORCED AND UNREINFORCED MASONRY BASEMENT WALLS J.J. ROBERTS

Control of Seismic Drift Demand for Reinforced Concrete Buildings with Weak First Stories

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

Soil Mechanics. Soil Mechanics

A perforated conduit such as pipe, tubing or tile installed beneath the ground to intercept and convey ground water. or structures.

EM Oct US Army Corps of Engineers ENGINEERING AND DESIGN. Slope Stability ENGINEER MANUAL

Interpretation of clogging effects on the hydraulic behavior of ion treated geotextiles

Physics 9e/Cutnell. correlated to the. College Board AP Physics 1 Course Objectives

Constant Rate of Strain Consolidation with Radial Drainage

Advanced Natural Gas Storage (ANGAS) Project and Verification Tests of Experimental Lined Rock Cavern in Japan

Nonlinear analysis and form-finding in GSA Training Course

The advantages and disadvantages of dynamic load testing and statnamic load testing

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

AP Physics - Chapter 8 Practice Test

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Consolidation and Settlement Analysis

Transcription:

CHAPTER 9 EARTH PRESSURE AND HYDRAULIC PRESSURE - C9-1 - CHAPTER 9 EARTH PRESSURE AND HYDRAULIC PRESSURE General This chapter deals with earth pressure and hydraulic pressure acting on exterior basement walls of buildings and retaining walls. AIJ's Recommendations for the Design of Building Foundations (2001) (hereafter referred to as the "RDBF") describes in detail the concept of basic load values that reflect the limit state design method more clearly than those in the past. In general, earth pressure acting on exterior basement walls is assumed to be earth pressure at rest. At depths below the groundwater level, the influence of hydraulic pressure is taken into consideration, and if there is surcharge on the ground surface, its influence is also taken into account. In the design of an exterior basement wall, serviceability limit states under earth pressure and hydraulic pressure that act permanently on the wall are taken into consideration. Earth pressure may increase under the influence of the dynamic interaction between the soil and the wall during an earthquake. Since, however, experience has shown that major damage does not occur even during an earthquake if the wall is designed taking into account the serviceability limit states under the earth pressure and hydraulic pressure that act permanently, checks on ultimate limit states under earthquake loading may be omitted. In general, earth pressure acting on a retaining wall is assumed to be active earth pressure, and is determined taking into account the influence of surcharge on the ground surface behind the wall and the influence of hydraulic pressure (if any). When retaining walls are designed, serviceability limit states under the earth pressure and hydraulic pressure that act permanently and ultimate limit states under active earth pressure during an earthquake are examined. The permanent earth pressure is calculated by using Coulomb's active earth pressure, and the earth pressure during an earthquake is calculated by using, for example, Mononobe and Okabe's formula for active earth pressure during an earthquake. The basic load values used in this guideline are values corresponding to those of the return period of 100 years or those corresponding to the 99-percent probability of non-exceedance. The basic values of hydraulic pressure dealt with in this chapter are values corresponding to a return period for the annual highest free water level of 100 years, and those values are determined taking into account time-dependent variations appropriately. Earth pressure that acts permanently varies very little over time but is strongly influenced by calculation accuracy and the uncertainty of geotechnical parameters. It is therefore necessary to determine basic values corresponding to a 99 percent probability of non-exceedance, assuming that such uncertainty is a main factor. As an example, this chapter describes the method of using the geotechnical parameter values at the site under consideration corresponding to a 99 percent probability of non-exceedance. In reality, however, a sufficient amount of data is often not available. In such cases, use of empirical values as basic values is permitted.

- C9-2 - Recommendations for Loads on Buildings Symbols Main symbols used in this chapter are as follows: Uppercase letters K 0 : coefficient of earth pressure at rest K A : coefficient of active earth pressure K EA : coefficient of active earth pressure during earthquake Lowercase letters c : cohesion of soil (kn/m 2 ) c! : cohesion of soil (kn/m 2, expressed in terms of effective stress) k h : design lateral seismic coefficient h : depth of groundwater level depth (m) p : earth pressure per unit area at depth z (kn/m 2 )! p : increase in earth pressure due to surcharge on the ground surface behind the retaining wall (kn/m 2 ) q : uniformly distributed load acting on the ground surface behind the retaining wall (kn/m 2 ) Greek Alphabet! : inclination of ground surface behind the retaining wall (deg)! t : wet unit weight of soil (kn/m 3 )! " : submerged unit weight (kn/m 3 )! w : unit weight of water (kn/m 3 )! : angle between the back of the retaining wall and the vertical plane (deg)! k : resultant incidence angle of earthquake ( tan 1 k h, deg)! : friction angle of retaining wall (deg)! : internal friction angle of soil (deg) 9.1 Overview (1) Earth pressure and hydraulic pressure In the design of an exterior basement wall or retaining wall, earth pressure reflecting the wet unit weight of the soil is assumed to be the load at depths above the groundwater level, and earth pressure and hydraulic pressure reflecting the submerged unit weight of the soil is assumed to be the load at depths below the groundwater level. In the case of a building with a basement, if the bottom of the foundation is below the groundwater level, buoyancy is considered as a load applied to the underside

CHAPTER 9 EARTH PRESSURE AND HYDRAULIC PRESSURE - C9-3 - of the foundation. This chapter describes the methods of calculation and concepts of these earth pressures, hydraulic pressures and buoyancy. As shown in Fig.9.1.1, the amount of earth pressure varies with the relative displacement between the building and the soil. Active earth pressure is the earth pressure that occurs when the soil behind the building reaches a plastic state as it pushes the wall forward. Passive earth pressure is the earth pressure that occurs when the soil behind the building reaches a plastic state as it is pushed back by the wall. Both active earth pressure and passive earth pressure occur in a state of plastic equilibrium in which the strength of the soil behind the wall is fully exerted. Earth pressure at rest is the earth pressure that occurs when the wall in contact with the soil is at rest. Earth pressure at rest is an intermediate state between active earth pressure and passive earth pressure. In general, as a retaining wall is displaced under the influence of the soil behind the wall, the earth pressure decreases with the progress of displacement and a state of earth pressure at rest tends to approach a state of active earth pressure. Theories proposed to calculate earth pressure in a plastic state include Coulomb's earth pressure theory and Rankine's earth pressure theory. The former derives earth pressure from the equilibrium conditions by assuming a limit state in which the soil behind the wall fails and a wedge of soil slips as the wall is moved. The latter derives earth pressure by assuming a plastic state that occurs when the entire soil block behind the wall fails. Coulomb's earth pressure theory is a practical method because it takes into consideration such parameters as the friction between the wall and the soil, the inclination of the wall and the inclination of the ground surface behind the wall. It is generally known that earth pressure values derived by Coulomb's method agree with the values derived by Rankine's method when these parameters take certain values. Figure 9.1.1. Relationship between displacement and earth pressure (2) Earth pressure that acts permanently on exterior basement walls It is common practice to examine the serviceability limit state of exterior basement walls by giving consideration to earth pressure and hydraulic pressure that act permanently. Since the displacement of

- C9-4 - Recommendations for Loads on Buildings exterior basement walls is small under normal conditions, earth pressure that acts permanently is calculated as earth pressure at rest. When designing exterior basement walls, the possibility of ultimate limit states in which earth pressure or hydraulic pressure that acts permanently predominates cannot be precluded. Ultimate limit states of this type may be neglected, however, because not much is known about the variability of the coefficient of earth pressure at rest and because no major damage was experienced in the past if serviceability limit states were examined against permanently acting earth pressure and hydraulic pressure. (3) Earth pressure that acts permanently on retaining walls It is generally said that although earth pressure acting on ordinary retaining walls varies depending on the soil behind them, the transition from earth pressure at rest to active earth pressure is caused by a very small amount of displacement. In the case of sandy soil, for example, the transition to active earth pressure can be caused by a very small forward horizontal displacement of the top of the retaining wall that is equal to only about 1/1,000 of the wall height. Even when earth pressure increases and approaches the earth pressure at rest because of seepage flow such as rainwater infiltration occurring over a long period of time, the retaining wall tends to be inclined again so that active earth pressure results. When designing ordinary retaining walls, therefore, it is acceptable to examine serviceability limit states by using active earth pressure as permanently acting earth pressure. If, however, very little displacement of the retaining wall under consideration is expected as in the case of a retaining wall in a dry area whose top and bottom are connected to a building, it is better practice to use earth pressure at rest instead of active earth pressure. In the design of retaining walls, the possibility of an ultimate limit state in which permanently acting earth pressure and hydraulic pressure are principal loads cannot be precluded. By the same reason as in the design of exterior basement walls, however, the examination of ultimate limit states in such cases may be omitted. In the case of a retaining wall, it is important to examine ultimate limit states, taking into consideration the influence of earthquakes described in Item (4) below. (4) Earth pressure during earthquake Earth pressure acting on exterior basement walls during an earthquake may become greater than the earth pressure at rest depending on the differences in the vibration properties of the surrounding ground and the building. No measurement result or damage that verifies such behavior has been reported, however, and it is thought that ignoring earth pressure increases during earthquakes is not likely to cause major problems if cross sections conforming to conventional allowable stress design criteria for sustained loading are used. When designing exterior basement walls in nonliquefiable soils, therefore, it is acceptable to examine serviceability limit states against permanently acting earth pressure and hydraulic pressure and omit the evaluation of ultimate limit states that takes into consideration earth pressure increases during earthquakes.

CHAPTER 9 EARTH PRESSURE AND HYDRAULIC PRESSURE - C9-5 - In soils that could liquefy during an earthquake, earth pressure and hydraulic pressure acting on the wall could increase considerably. In such cases, it is necessary to examine ultimate limit states by assuming that a soil water mixture with a unit weight of 18 to 20 kn/m 3 applies pressure on the wall. When liquefaction occurs, buoyancy acting on the underside of the foundation increases considerably. It is therefore necessary to examine safety against buoyancy in the case where a building is floating in a soil water mixture with a high specific gravity. Cases of major earthquake-induced damage to retaining walls not accompanied by the liquefaction of the soil behind the walls have been reported. There is a need, therefore, for the evaluation of ultimate limit states during a major earthquake in addition to the examination of serviceability limit states under permanently acting earth pressure and hydraulic pressure. In the case of a retaining wall, stability of the entire ground behind the retaining wall including the wall is often an important consideration. In such cases, it is necessary to perform stability evaluation by an appropriate method such as the circular slip method in addition to the examination of stability under active earth pressure during an earthquake. (5) Basic values of earth pressure and hydraulic pressure and their uncertainty Earth pressure is calculated by appropriately taking into account the influence calculation accuracy and the uncertainty geotechnical parameters (unit weight and strength parameters of soil). Fluctuations of groundwater level are also taken into account as appropriate. This guideline uses the values corresponding to the 100-year return period or the values corresponding to a probability of non-exceedance of 99 percent as basic load values. Earth pressure that acts permanently does not change over time, and earth pressure values are greatly dependent on the degree of uncertainty determined by the accuracy of calculation methods and the variability of geotechnical parameters. When considering earth pressure, therefore, it is necessary to determine basic values corresponding to a probability of non-exceedance of 99 percent, assuming that these types of uncertainty are primary factors. As an example of such a method, Section 9.6 describes the method of using geotechnical parameter values for the soil at the site consideration corresponding to a probability of non-exceedance of 99 percent. In reality, it is often not possible to obtain a sufficient amount of geotechnical data. In such cases, values recommended in, for example, the Recommendations for the Design of Building Foundations (backfill-related parameter values shown for reference in the RDBF's Table 3.4.2) are used. These values are considerably conservative values that have been calculated so that they can be used in cases where detailed surveys are not conducted. For the time being, therefore, these values are assumed to be comparable to the values corresponding to a probability of non-exceedance of 99 percent. In the calculation of earth pressure during an earthquake, values corresponding to the 100-year return period are used as basic values, taking into consideration not only the degree of uncertainty resulting from the accuracy of calculation methods and the variability of geotechnical parameters but

- C9-6 - Recommendations for Loads on Buildings also changes caused by earthquake motions. It should be kept in mind, however, that as explained in Section 9.4, at present, highly accurate estimation for earthquake motions of various sizes is not necessarily possible. For example, the Mononobe Okabe equation 2),3) is used to calculate active earth pressure acting on retaining walls during an earthquake. It should be noted, however, that the design horizontal seismic coefficient substituted in the Mononobe Okabe equation does not necessarily correspond to the value obtained by dividing the maximum horizontal acceleration amax by gravitational acceleration g. The reason is that the accuracy of the calculation method applied to earth pressure during a strong earthquake is not sufficiently high. Although the Mononobe Okabe equation is used in design, but in cases involving a strong earthquake, the design horizontal seismic coefficient is determined by reference to, for example, the values back-calculated from the data on the damage caused by the Hyogo-ken Nanbu Earthquake. In view of these circumstances, it has been decided to permit the method of using empirical values for the design horizontal seismic coefficient in the Mononobe Okabe equation and assume that the active earth pressure calculated from the Mononobe Okabe equation has been obtained by using a value corresponding to the 100-year return period. It should be noted, however, that the concepts of basic values of earth pressure recommended in this guideline are provisional ones intended for use before the transition to the limit state design method. Depending on the accumulation of research findings in the coming years, it is necessary to make the method for calculating the basic values of earth pressure more straightforward and clear-cut. For the method of hydraulic pressure calculation, refer to Section 9.5. 9.2 Earth Pressure and Hydraulic Pressure acting on Exterior Basement Walls As shown in Fig.9.2.1, earth pressure that act on exterior basement walls is assumed to be earth pressure at rest, and hydraulic pressure is also taken into consideration at depths below the groundwater level. If there is surcharge on the ground surface, its effect is also taken into account. (1) Coefficient of earth pressure at rest, K 0 The use of the results of field measurements and laboratory tests on collected samples has been considered for the determination of the coefficient of earth pressure at rest, K 0. Although the amount of field measurement data obtained for the determination of the coefficient of earth pressure at rest is limited, it is generally said that there a substantial amount of data indicating a value of around 0.5. Laboratory tests conducted to measure the coefficient of earth pressure at rest include compression tests, and triaxial compression tests in which lateral displacement is restricted. The coefficient of earth pressure at rest varies depending on such factors as soil type, strength and stress history. Many have reported, however, that in a state of normal consolidation, measured values for both sand and clay show fairly good agreement with the values given by the equation proposed by Jàky. 4)

CHAPTER 9 EARTH PRESSURE AND HYDRAULIC PRESSURE - C9-7 - K = 1# sin!" (9.2.1) 0 Figure 9.2.1. Earth pressure and hydraulic pressure acting on exterior basement wall In this equation, if the internal friction angle!" expressed in terms of effective stress is 30, then K 0 is 0.5. Eq.(9.2.1) was obtained by solving the stress at rest in the central vertical plane of a two-dimensional triangular fill and simplifying the obtained equation. At present, therefore, data that clearly show the relationship with the actual state of exterior basement walls are lacking although there are some theoretical bases. In view of these circumstances, it is deemed reasonable to use a value of 0.5 or so for the coefficient of earth pressure at rest for both sand and clay except in cases where highly reliable laboratory test or field measurement results are available. The above discussion concerns the coefficient of earth pressure at rest in the case where the ground surface behind the wall is horizontal. If the ground surface behind the wall is inclined, the following equation has been proposed 5) : K 0! = K 0 (1 + sin!) (9.2.2) where K0! is the coefficient of earth pressure at rest K0 for an inclined backfill; K 0, the coefficient of earth pressure at rest for normally consolidated soil; and!, the inclination of the backfill surface (deg). Knowledge that has been gained about the nature of the coefficient of earth pressure at rest includes the following. It is generally known from laboratory test results that the value of coefficient of earth pressure at rest, where K ou, for overconsolidated soil can be estimated by using the equation 6) : sin!" 0 = K 0 (OCR) K u (9.2.3) K ou is the coefficient of earth pressure at rest for overconsolidated soil; K 0, the coefficient of earth pressure at rest for normally consolidated soil;!", the internal friction angle expressed in

- C9-8 - Recommendations for Loads on Buildings terms of effective stress (deg); and OCR, the overconsolidation ratio (the value obtained by dividing the maximum effective stress experienced in the past by the present effective vertical stress). Ladd et al. 7) report that the coefficient of earth pressure at rest for normally consolidated undisturbed clay is strongly correlated with the plasticity index when I p =15, and K 0 tends to converge to 0.8 as I p I p. According to them, K 0 =0.5 increases. Kikuchi et al. measured the coefficient of earth pressure at rest K 0 for clay and showed that it was about 0.5 regardless of the value of I p. These results indicate that the relationship between I p and the coefficient of earth pressure at rest varies considerably, and at present it is difficult to find out a general tendency. In Kikuchi et al.'s study, too, the relationship between K 0 and!" is explained by Jàky's equation. 8) Hatanaka et al. conducted a study on the K 0 of gravelly soil. According to that study, K 0 is strongly correlated with the in situ shear wave velocity proposed 9) : (2) Case in which load acts on ground surface K V SF, and the following equation has been = 0.0058V " 0.5( V 300m / ) (9.2.4) 0 SF SF! s In the case where a concentrated load acts on the ground surface, the following equation can be used to calculate the amount of increase in horizontal stress at the location of the exterior basement wall (Fig.9.2.2):! p 0 = " 3Px 2 z 2 2 ( r + z ) 5 2 (9.2.5) where P is a concentrated load (kn); r, the horizontal distance from the point of action of the load to the location of interest (m); x, the shortest distance from the point of action of the load to the exterior basement wall; and z, the vertical distance from the point of action of the load to the location of interest (m).

CHAPTER 9 EARTH PRESSURE AND HYDRAULIC PRESSURE - C9-9 - Figure 9.2.2. Horizontal stress components acting on exterior basement wall Equation(9.2.5) calculates the horizontal stress acting on a displacement-free exterior basement wall by assuming that the ground is a semi-infinite elastic body, determining the horizontal stress in the ground in the case where a concentrated load acts on the ground surface by use of the Boussinesq solution and multiplying the obtained value by two by use of the principle of reflection. The calculation method is described in detail in the RDBF. 1) If the load is distributed in a certain part of the ground surface, incremental increases in earth pressure can be calculated by integrating Eq.(9.2.5). If a uniformly distributed load acts on the ground surface, the earth pressure obtained by multiplying the amount of increase in vertical stress by the coefficient of earth pressure is taken as an incremental earth pressure,! p0. If the increment of vertical earth pressure is assumed, by way of approximation, to be equal to the uniformly distributed load q acting on the ground surface, Eq.(9.2.6) can be obtained:! K q (9.2.6) p0 = 0 where q is a uniformly distributed load (kn/m 2 ). 9.3 Earth Pressure that acting Permanently on Retaining Walls As shown in Fig.9.3.1, earth pressure that acts permanently on a retaining wall is assumed to be active earth pressure. The active earth pressure resultant per unit width is 2 p 0.5p H, and it acts at the location of H 0 3 from the bottom of the raining wall at an angle of " +!. Equation(9.4) is the Coulomb coefficient of active earth pressure derived from the rigid plastic theory. When the ground surface is horizontal and the back of the wall is vertical and therefore friction can be ignored, the Coulomb coefficient of active earth pressure is expressed as shown below and is equal to the Rankine coefficient of active earth pressure. & # = tan 2 ( K A $ 45 '! (9.3.1) % 2 " The incremental earth pressure in the case where a uniformly distributed load acts on the ground surface can be calculated from the following equation: where q is a uniformly distributed load (kn/m 2 ); and A =! p 0 = K q (9.3.2) A K A, the coefficient of active earth pressure. A 0

- C9-10 - Recommendations for Loads on Buildings Figure 9.3.1. Earth pressure acting permanently on retaining wall Total earth pressure is calculated by calculating the incremental earth pressure from Eq. (9.3.2) and adding the result to Eq.(9.3). Vertical stress transferred to the soil decreases with depth depending on the angle of wall friction. This is usually not taken into consideration, and Eq.(9.3.2) is used regardless of depth. If necessary, the influence of hydraulic pressure is taken into consideration. The calculation procedure is the same as the procedure used for Eq.(9.2) for exterior basement walls. When designing retaining walls, it is standard practice to provide drainage facilities. During long periods of wet weather such as localized heavy rains and seasonal rains during tsuyu (rainy season in Japan), the backfill may become saturated so that the backfill fails because of high hydraulic pressure. If, therefore, such cases are anticipated, it is necessary to conduct a study using the unit weight of soil in a saturated state and the strength parameters for saturated soil and examine ultimate limit states under unusual water level conditions. 9.4 Earth Pressure acting on Retaining Walls During Earthquake (1) Mononobe Okabe formula for active earth pressure during earthquake When calculating earth pressure acting on a retaining wall, it is common practice to use the Mononobe Okabe formula (Eq.(9.6)) for calculating earth pressure acting during an earthquake. Eq.(9.6) was derived by making the horizontal seismic coefficient k h during an earthquake act on the back of the retaining wall and considering the equilibrium of forces in a limit state. Although some cases have been reported in which values given by the formula showed good agreement with the results of shaking table tests involving standing-wave excitation. Very little information is available, however, about verification made by use of measurement data collected during earthquakes. When calculating earth pressure during an earthquake, it is desirable to determine the value of design horizontal seismic coefficient k h in Eq.(9.6) according to the value of maximum horizontal

CHAPTER 9 EARTH PRESSURE AND HYDRAULIC PRESSURE - C9-11 - acceleration a max corresponding to the 100-year return period described in Chapter 7 (seismic load). It is necessary, however, to keep in mind that if a wide range of earthquake motions ranging from medium to small earthquake to large earthquakes need to be covered, the accuracy of calculation of earth pressure during an earthquake by use of Eq.(9.6) is not necessarily high. In the examination of earth pressure during medium to small earthquakes, k h = a max g ( a max : maximum horizontal acceleration of the soil block behind the wall, g: gravitational acceleration) may be assumed. In the examination of earth pressure during large earthquakes, however, calculation results obtainable from Eq.(9.6) assuming k h = a g would be excessively large. Because Eq.(9.6) max is derived from the equilibrium of a rigid plastic body ignoring the deformation of the ground behind the wall, the equation does not reflect the deformation of ground during a large earthquake or the softening of soil from the maximum strength due to the localization of ground strains. Consequently, the determination of the value of k h by use of a large value of maximum horizontal acceleration during a large earthquake will result in the assumption of an unrealistic slip line and hence overestimation. It is generally said that the range of acceleration in which use of the maximum horizontal acceleration is below 200 Gal or so. 10),11) For these reasons, the RDBF recommends to use k h may be calculated by k h values of 0.2 or so for the examination of damage limit states during medium to small earthquakes with an acceleration of less than about 200 Gal and The k h values of 0.25 or so for the examination of ultimate limit states during large earthquakes. k h values for medium to small earthquake motions are empirical values that have been used conventionally, and the k h values for large earthquake motions have been determined mainly from the values 14) back-calculated from the results of housing retaining wall and slope surveys conducted after the Hanshin Awaji Earthquake. This guideline follows the same philosophy, so no effort is made to achieve correspondence between the design horizontal seismic coefficient and the values corresponding to the 100-year return period of the peak ground acceleration. Instead, empirical values recommended in the RDBF are used for the design horizontal seismic coefficient, and the active earth pressure at rest calculated from the Mononobe Okabe equation is regarded as the earth pressure obtained by using the value corresponding to the 100-year return period. It is to be noted that the concept of earth pressure during an earthquake described above is a tentative approach used before a changeover to the limit state design method. It is necessary to make the concrete method for determining the basic values of earth pressure more straightforward and clear-cut by accumulating more research results. As one way to do it, a recently proposed modified Mononobe Okabe method is introduced below. The Mononobe Okabe method assumes that shear strength is isotropic and constant. In reality, however, the internal friction angle of soil along a failure surface decreases from peak strength to residual strength. Koseki et al. proposed a modified Mononobe Okabe equation that takes into consideration the effect of strain localization in the shear zone and the effect of the resultant strain softening. 10),11) In this method, the design horizontal seismic coefficient k h is assumed to be equal to a max g when the maximum horizontal acceleration a max of the ground behind the wall is between

- C9-12 - Recommendations for Loads on Buildings about 200 Gal and 700 Gal. In the Koseki et al.'s method, the peak strength! peak and the residual strength! res in the Mononobe Okabe equation are first evaluated by one method or another, for example by laboratory testing or according to empirical rules, and the conditions for the first active failure are determined. The design horizontal seismic coefficient assumed in this method is slip surface formed, k = kcr,and the inclination of the! =! cr, is calculated by using the Mononobe Okabe method assuming! =! peak (Fig.9.4.1). Then, from the equilibrium of forces acting on the wedge whose bottom is the slip surface calculated earlier, the coefficient of active earth pressure acting on the initial failure surface, K! EA, is calculated from the following equation: Figure 9.4.1. Forces acting on a wedge of soil (" & %)( 1 + tan$ tan" )( 1 + tan$ tan! )( tan( " & %) + tan$ k ) cos( " & % & $ & # )( tan" & tan! ) cos K ' = (9.4.1) EA where K! EA is the coefficient of active earth pressure during an earthquake in the modified Mononobe Okabe equation;!, the inclination of the slip surface (deg);!, the internal friction angle of soil (deg);!, the angle between the back of the retaining wall and the vertical plane (deg);!, the friction angle of the wall (deg);!, the inclination of the ground surface behind the wall;! k, the resultant incidence angle of an earthquake (=tan 1 k h, deg); and coefficient. In the above equation, the internal friction angle! of the soil is lowered to k h, the design horizontal seismic! res. The inclination of the failure surface,!, is fixed at the angle of the initial slip surface,! cr. This coefficient of active earth pressure, from Eq.(9.6) by assuming coefficient of active earth pressure K! EA, is compared with the coefficient of active earth pressure K EA calculated horizontal seismic coefficient during an earthquake,! =! peak. If the former is smaller than the latter, it is assumed that the K! EA acting on the initial slip surface is still in effect. The k h, cr, used to determine the first failure surface is determined arbitrarily. This is as yet no established method for determining this, and empirical values of about 0 to 0.2 are often used. By taking into consideration decreases in the internal friction angle, the modified

CHAPTER 9 EARTH PRESSURE AND HYDRAULIC PRESSURE - C9-13 - Mononobe Okabe equation gives a value of the coefficient of active earth pressure greater than the value obtained by assuming obtained by assuming K! EA that is! =! peak in Eq. 9.6 and is smaller than the value! =! res in Eq. 9.6. The modified Mononobe Okabe equation makes it possible to calculate active earth pressure corresponding to a large design horizontal seismic coefficient ( k h ) to which the Mononobe Okabe equation cannot be applied, and gives a more realistic, smaller active failure region than the Mononobe Okabe equation. As an example, Fig.9.4.2 shows the relationship between the design horizontal seismic coefficient pressure k h and the coefficient of active earth K! EA. As shown, compared with the Mononobe Okabe equation, the modified Mononobe Okabe equation gives more realistic values of active earth pressure for large values of design horizontal seismic coefficient k h. This guideline does no more than explain the evaluation method for the geotechnical parameters! =! peak and! res used in the above method partly because the method is not yet in wide use and partly because the method involves relatively complex calculation and there are still a number of unsolved problems such as the difficulty in determining the first failure surface. It is generally known that in the Mononobe Okabe equation, after a slip surface due to the first active failure is formed, the acceleration acting on the sliding block does not increase regardless of the amount of further increase in the acceleration of the ground behind the wall. 12),13) According to this concept, there should be an upper limit to active earth pressure during an earthquake. Further study is needed, therefore, in this area. Figure 9.4.2. Coefficient of active earth pressure K! EA in the modified Mononobe Okabe equation (2) Trial wedge method As shown in Figs.9.4.3 and 9.4.4, the trial wedge method is a method for determining active earth pressure during an earthquake from the equilibrium of forces acting on the soil mass behind the wall by assuming the angle of active slip! during an earthquake. In this method, the active earth pressure

- C9-14 - Recommendations for Loads on Buildings at the time the equilibrium condition is met is determined from a funicular polygon by varying!. In the trial wedge method, the cohesion in the Mononobe Okabe equation can be taken into consideration. For the design horizontal seismic coefficient used for calculation in the trial wedge method, a conceptual approach similar to the one used for the design horizontal seismic coefficient in the Mononobe Okabe equation is used. The method described above is applicable to independent retaining walls whose displacement is not constrained. In cases where the bottom and top of a retaining wall is connected to a building so that there is likely to be little wall displacement, as in the case of a retaining wall in a dry area, earth pressure that acts during an earthquake does not necessarily become an active earth pressure. Instead, it may even become closer to the passive side. As mentioned in Section 9.1, for a retaining wall like this, it is appropriate use earth pressure at rest for earth pressure that acts permanently. When considering earth pressure during an earthquake, it is necessary to use earth pressure calculated as the sum of earth pressure at rest and the increase in earth pressure due to the earthquake. Failure of retaining walls like this, however, has not been reported, and at present sufficient knowledge is not available about to what extent earth pressure during an earthquake should be increased. This is an area that requires further study. In design, it will be necessary to conduct a study on a case-by-case basis through, for example, earthquake response analysis or to determine earth pressure by reference to reported analysis results. 15) Figure 9.4.3. Trial wedge method ignoring the cohesion in the Mononobe Okabe equation

CHAPTER 9 EARTH PRESSURE AND HYDRAULIC PRESSURE - C9-15 - Figure 9.4.4. Trial wedge method taking into consideration the cohesion in the Mononobe Okabe equation 9.5 Design Groundwater Level (1) Design groundwater level Soil layers include high-permeability layers such as sandy soil layers and low-permeability layers such as clay layers, and these layers often appear as alternations. Since perched water, free water and confined water exist, it is necessary to judge which of these different types of water will influence the building greatly. Factors contributing to free water surface fluctuations include factors related to the natural environment such as rain, snowmelt, tide and floods and anthropogenic factors such as pumping from wells, pumping regulation and subway construction. Each city has records of past groundwater level fluctuations. Government organizations such as the Ports and Harbors Bureau, the National Land Agency (now restructured) and the Environment Agency also have their records. If hydraulic pressure is not a primary load, the design groundwater level is determined by decreasing the value corresponding to the 100-year return period, aiming at a target value set around the highest water level determined from estimated fluctuations over a period of one year. One-year fluctuations are not necessarily estimated from one-year water level measurement results. Instead, they are judged from free water level observation records for past several years. If hydraulic pressure is a primary load in the evaluation of ultimate limit states (examination of conditions during periods of abnormal water level), the design groundwater level is determined by increasing the value corresponding to the 100-year return period according to estimated fluctuations. Water level fluctuations are estimated from records of abnormal water levels. Pressure acting at a point in water is consistent with hydrostatic pressure distribution. In the ground, however, impermeable layers or low-permeability layers of such materials as clay and silt and permeable layers or aquifers of sand and gravel often form alternations, so pressures at particular points are not necessarily consistent with the overall hydrostatic pressure distribution. Since, however,

- C9-16 - Recommendations for Loads on Buildings measurement results indicate that hydraulic pressures at depths below the free water level seldom exceed the hydrostatic pressure distribution, design groundwater level is determined on the basis of the free water level. If the confined water level is higher than the free water level because of, for example, the inclination of the geological formations, a detailed groundwater survey should be conducted. (2) Buoyancy At the floor slab of a basement, for example, because hydraulic pressure at the groundwater table is zero, buoyancy that can be calculated by multiplying water depth by the unit weight of water occurs. This buoyancy may cause the entire building to be lifted up, but buoyancy that is stable over a long period of time can be expected to reduce vertical loads. To be conservative in a study of the uplift of a building, groundwater level should be assumed to be high. To be conservative in expecting a vertical load reduction, groundwater level should be assumed to be low. If liquefaction occurs during an earthquake, buoyancy is caused by excess pore hydraulic pressure. It is therefore necessary to pay careful attention in design to the possibility of a large amount of buoyancy. In such cases, a unit weight of muddy water of 18 to 20 kn/m 3 is used in place of 9.1 to calculate buoyancy.! w in Eq. 9.6 Uncertainty of Earth Pressure and Geotechnical Parameters used for Design Purposes (1) Coefficients of variation of geotechnical parameters Parameters affecting earth pressure include the following: 1) Geotechnical parameters 2) Geometric parameters c : cohesion of soil (kn/m 2 )! : internal friction angle of soil (deg)! : unit weight of soil (kn/m 3 )! : wall friction angle (deg) z : vertical depth from the upper end of the wall to the location at which earth pressure is to be calculated (m) H : wall height (m)! : inclination of the ground surface behind the wall (deg)! : angle between the back of the wall and the vertical plane (deg) h : groundwater level (m) 3) Load-related parameters q : surcharge on the ground surface behind the wall (kn/m 2 ) k h : design horizontal seismic coefficient Factors contributing the variability of geotechnical parameters include inhomogeneity and

CHAPTER 9 EARTH PRESSURE AND HYDRAULIC PRESSURE - C9-17 - anisotropy of soil, soil sampling methods and test methods. In general, the coefficient of variation of cohesion, which is a parameter that is subject to considerable variation, ranges between 0.2 and 0.4, and that of the internal friction is 0.1 to 0.2. In contrast, the coefficient of variation of unit weight is so small (0.02 to 0.08) that it may be practically regarded as a determined value. 16) Using the Mononobe Okabe equation, Matsuo et al. 17) evaluated variations in the active earth pressure of sand, silt and clay by the Monte Carlo method. They examined the internal friction angle (! =30, 35, 40 ) for sand, the internal friction angle (! =10, 20, 30 ) and cohesion (c=9.8, 14.7, 19.6 kn/m 2 ) for silt, and the internal friction angle (! =5 ) and cohesion (c=14.7, 19.6 kn/m 2 ) for clay. The coefficients of variation for the internal friction angle and cohesion were V = 0. 05, 0.10 and V c = 0.2,03, respectively, and normal distribution was assumed. The wall friction angle! was assumed to be 2! 3. From these results, it is generally said that normal distribution may be assumed for active earth pressure. Variations in shape and dimensions include variations in wall height and angle. These variations occur depending on construction accuracy. Although their statistical properties are still largely unknown, these variations are generally said to be relatively small. Surcharge on the ground surface behind the wall varies considerably depending on the conditions around the building.! (2) Values corresponding to 99% probability of non-exceedance Site-specific geotechnical parameters are determined at the design stage on the basis of geotechnical survey and soil test results. When determining the characteristic values or statistical properties, therefore, it is necessary to take into consideration the uncertainty of sampling. Basically, the values corresponding to the 99-percent probability of non-exceedance for the site under consideration are used. The values that are used, however, are limited to estimated values determined giving consideration to values that are abnormal from the viewpoint of engineering and the number of data sets. Thus, because available information is limited mainly for economic reasons, the lack of information is often compensated by, for example, empirical knowledge about buildings of the same type or sites with similar geological conditions or engineering judgment that takes into consideration such factors as the region that influences the limit states of the building under consideration. If a certain amount of data is available and a statistical method can be applied, characteristic values can be estimated, on the basis of sample distribution, as follows. The sample mean x and the sample variance x 2 of a sample x i (i=1, 2,..., n) can be calculated as s 2 = 1 n x =! n 1 ( n " 1) x i i= 1 n ( x i x)! " i= 1 2 (9.6.1a) (9.6.1b) Since the values corresponding to the 99-percent probability of non-exceedance follow a

- C9-18 - Recommendations for Loads on Buildings t-distribution with a degree of freedom n! 1, characteristic values can be defined, considering the confidence level 1 "!, as follows 18) : x k 1 x ± t" ; n 1 s 1+ (9.6.2) n =! In the above equation, the plus/minus (±) values are determined so as to be conservative with respect to limit states. The term t a; n! 1 is a point with a confidence level of! percent. For example, for a 99-percent confidence interval and n!1 = 20, t 2. 528 values of t 0.01; n! 1. 0.01;20 =. Table 9.6.1 shows representative Table 9.6.1 representative values of t 0.01; n! 1. n!1 5 10 15 20 25 30 60 120! t 0.01; n! 1 3.365 2.764 2.602 2.528 2.485 2.457 2.390 2.358 2.326 As mentioned in Section 9.1, however, the amount of geotechnical data that are actually available is not necessarily sufficient. In such cases, empirical values that have been used conventionally, for example, the values recommended in the RDBF (Mononobe Okabe equation's parameter values shown for reference in Table 3.4.2 in the RDBF) are used as basic values. Because these values are conservative values for use in cases where detailed surveys are not conducted, they are regarded, for the moment, as values corresponding to the 99 percent probability of non-exceedance. Besides the uncertainty of these parameters, the accuracy of the earth pressure formula (uncertainty of the model) greatly influences the uncertainty of earth pressure. Concerning the accuracy of the earth pressure formula, it is necessary to compare the formula with in situ measurement data including accurate measurements of geotechnical parameters. This is not practiced widely, however, partly because earth pressure measurement itself is difficult. It is believed that a rational limit state design method can be established by investigating the uncertainty of construction methods in addition to accumulating such measurement data. References 1) Architectural Institute of Japan : Recommendation for design of building foundation 2) Mononobe, N. and Matsuo, H.: On determination of earth pressure during earthquake, Proceedings of World Engneering Congress, Tokyo, Vol.9, pp.177-185, 1929. 3) Okabe, S. : General theory on earth pressure and seismic stability of retaining wall and dam, Journal of Japan Society of Civil Engineers, Vol.10, No.6, pp.1277-1323, 1924. 4) Jáky, J. : Pressure in soils, Proc. of 2nd ICSMFE, Vol.1, pp.103-107, 1948. 5) Danish Geotechnical Institute : Code of practice for foundation engineering, Danish Geotechnical Institute Copenhagen, Denmark, Bulletin No.32, 1978. 6) Mesri, G. and Hayat, T. M. : The coefficient of earth pressure at rest, Canadian Geotechnical Journal, Vol.30, pp.647-666, 1993. 7) Ladd, C., Foot, R., Ishihara, K., Schlosser, F. and Poulus, H. G. : Stress deformation and strength

CHAPTER 9 EARTH PRESSURE AND HYDRAULIC PRESSURE - C9-19 - characteristics, State-of the arts reports, Proc. of 9th ICSMFE, Vol.4, pp.421-494, 1977. 8) Kikuchi, Y., Tsuchida, T. and Nakashima, K.: Measurements of K0 Values of Marine Clays by Triaxial Tests, Technical Note of the Port and Harbour Research Institute No.577, 27p. 1987. 9) Hatanaka, M., Uchida, A. and Taya, Y.: Estimating K 0 -value of in-situ gravelly soils, Soils and Foundations, Vol.39, No.5, pp.93-101, 1999. 10) Koseki, J., Tatsuoka, F., Munaf, Y., Takeyama, M. and Kojima, K. : A modified procedure to evaluate active earth pressure at high seismic loads, Soils and Foundations, Special Issue on Geotechnical Aspects of the January 17 1995 Hyogoken-Nambu Earthquake No.2, pp.209-216, 1998.9. 11) Koseki, J., Tatsuoka, F., Horii, K., Tateyama, M., Kojima, K. and Munaf, Y. : Procedure to evaluate active earth pressure at high seismic loads levels for conventional and geosynthetic-reinforced soil retaining walls, Proceedings of the 10th Japan Earthquake Engineering Symposium, pp.1563-1568, 1998. 12) Kasuya, H., Okada, J., Hanafusa, T., and Enoki, M. : The experiment of earth pressure and motions of retaining wall during earthquake, Proceedings of 38th Japan National Conference on Geotechnical Engineering, pp1621-1622, 2003.7. 13) Okada, J., Kasuya, H., Hanafusa, T., and Enoki, M. : Theoretical study on the motion of retaining wall during earthquake, Proceedings of 38th Japan National Conference on Geotechnical Engineering, pp1623-1624, 2003.7. 14) Commentary on the Housing Site Disaster Prevention Manual Revision, supervised by the Private Sector Building Land Development Office, Economic Affairs Bureau, Ministry of Construction, Gyousei Corporation, pp.86-88, 1998.5 (in Japanese) 15) Aoki M. : Evaluation of Earth Pressure and Bearing Capacity of Foundations on Slopes, The KENCHIKU GIJUTSU, pp.126-135, 2000.2 (in Japanese) 16) JGS : Reliability-based Design for Soil & Foundation, Soil & Foundation Engineering Library 28,1985 (in Japanese) 17) Matsuo, M. : Geotechnical Engineering, Idea and Practice of Reliability-based Design, Gihodo Shuppan, pp248-264, 1984 (in Japanese) 18) CEN : ISO2394, General Principles on Reliability for Structures, 1998