In the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the



Similar documents
X-ray Imaging Systems

X-ray Imaging Systems

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

Cathode Ray Tube. Introduction. Functional principle

Voltage nominal maximum for test. Inverse voltage. nominal maximum for test. Focal spots (IEC 60336:2005) small large

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

X-Mind. Instinct for perfection

The Tesla Roadster battery pack is comprised of about 6800 of these cells, and the entire pack has a mass of about 450kg.

E/M Experiment: Electrons in a Magnetic Field.

Evaluating Induction Motor Rotor Bars with Electrical Signature Analysis

AS COMPETITION PAPER 2008

Torque motors. direct drive technology

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

The Electrical Properties of Materials: Resistivity

X-RAY TUBE SELECTION CRITERIA FOR BGA / CSP X-RAY INSPECTION

Chen. Vibration Motor. Application note

Energy and Energy Transformations Test Review

The Basics of Scanning Electron Microscopy

General Guidelines for Building Aluminum Production Injection Molds

Thermopile Support: FAQs, Troubleshooting, Care & Maintenance

Vacuum Evaporation Recap

Shaft grounding. Carbon brushes for shaft grounding are used in turbo-generators, in distinct AC- and DC motors and as a special application in Ships.

The Three Heat Transfer Modes in Reflow Soldering

i3 STC Kit Extension Activities North Carolina

Topic Page Contents Page

Production of X-rays and Interactions of X-rays with Matter

Interested in conducting your own webinar?

1. At which temperature would a source radiate the least amount of electromagnetic energy? 1) 273 K 3) 32 K 2) 212 K 4) 5 K

Material Comparison Lower Quality Blender Optimum Electric Motor Assembly. Plastic Fans Low cost

2005 WJTA American Waterjet Conference August 21-23, 2005 Houston, Texas Paper SAFE WATERJET CLEANING OF STEEL PROCESS LINES

5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION

A/C refrigerant system, overview

1. The diagram below represents magnetic lines of force within a region of space.

Understanding the Alternator

Electric Motor. Your Activity Build a simple electric motor. Material. Create. Science Topics. What s going on? 2 Jumbo Safety Pins (or Paper Clips)

جامعة البلقاء التطبيقية

Lecture slides on rolling By: Dr H N Dhakal Lecturer in Mechanical and Marine Engineering, School of Engineering, University of Plymouth

TEACHER BACKGROUND INFORMATION THERMAL ENERGY

Roller Chain Coupling

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.

DIRECT CURRENT GENERATORS

THE EFFECT OF BLADE ANGLE AND SIZE ON WIND TURBINE PERFORMANCE

NetShape - MIM. Metal Injection Molding Design Guide. NetShape Technologies - MIM Phone: Solon Road FAX:

Electron Beam and Sputter Deposition Choosing Process Parameters

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

Sap Steady UV Unit for Maple Sap

Application Information

BUT PRECAUTIONS MUST BE TAKEN OR SERIOUS BURNS CAN RESULT.

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

Photovoltaic System Technology

The soot and scale problems

Gunite Disc Brake Rotors

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Tom Wilson Product Marketing Manager Delivery Systems Varian Medical Systems International AG. CERN Accelerator School, May 2015

Balzers Sputter Coater SCD 050

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

Permanent Magnet Motor Kit, Magnetic Reed Type. (SKY-ReedMotorKit) Instructions

Force on Moving Charges in a Magnetic Field

TRIMMING UNIT/DIAMOND MACHINE TST.13

Seasonal & Daily Temperatures. Seasons & Sun's Distance. Solstice & Equinox. Seasons & Solar Intensity

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

Surface roughness. Picture 1: Friction coefficient as a function of surface roughness Curve 1: Roughness R z 0,5µm Curve 2: Roughness R z 5 µ

TIG WELDING TIPS by Tom Bell

BUILDING A BASIC CIRCUIT

Stainless Steel Marking Guide

Measurement of Charge-to-Mass (e/m) Ratio for the Electron

Basics of Electricity

Tableting Punch Performance Can Be Improved With Precision Coatings

Using and Wiring Light Emitting Diodes (LEDs) for Model Railroads

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

JEFFERSON COLLEGE. Radiographic Physics

Note: You will receive no credit for late submissions. To learn more, read your instructor's Grading Policy

Survival Laser SL-001BB Laser Parts Bundle Assembly & Operation Instructions

7. What is the current in a circuit if 15 coulombs of electric charge move past a given point in 3 seconds? (1) 5 A (3) 18 A (2) 12 A (4) 45 A

View of ΣIGMA TM (Ref. 1)

Helium-Neon Laser. Figure 1: Diagram of optical and electrical components used in the HeNe laser experiment.

Displays. Cathode Ray Tube. Semiconductor Elements. Basic applications. Oscilloscope TV Old monitors. 2009, Associate Professor PhD. T.

PS-6.2 Explain the factors that determine potential and kinetic energy and the transformation of one to the other.

RICHARD T ELL ASSOCIATES,INC.

COMPARISON OF DRILLING TECHNOLOGIES BETWEEN TOP DRIVE AND ROTARY TABLE IN GEOTHERMAL FIELDS: A CASE STUDY OF OLKARIA GEOTHERMAL FIELDS.

3D Printing LESSON PLAN PHYSICS 8,11: OPTICS

Roller bearing life. The Reaction of AISI Bearing Steel to Heat

X-Ray Diffraction HOW IT WORKS WHAT IT CAN AND WHAT IT CANNOT TELL US. Hanno zur Loye

Tech Bulletin. Understanding Solar Performance

Magnetic Deburring & Polishing Machine

Laserlyte-Flex Alignment System

Coating Technology: Evaporation Vs Sputtering

Energy Transformation Lab

UNIVERSITY OF SASKATCHEWAN Department of Physics and Engineering Physics

Chapter 18 Temperature, Heat, and the First Law of Thermodynamics. Problems: 8, 11, 13, 17, 21, 27, 29, 37, 39, 41, 47, 51, 57

Students will investigate the characteristics of electromagnetism and then use what they learn to plan and conduct an experiment on electromagnets.

Handling Corrosive or Abrasive Liquids

RESULTS OF ICARUS 9 EXPERIMENTS RUN AT IMRA EUROPE

Unit 6: EXTRUSION. Difficult to form metals like stainless steels, nickel based alloys and high temperature metals can also be extruded.

Theory of Heating by Induction

BB-18 Black Body High Vacuum System Technical Description

Transcription:

In the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the discussion on the major components of the x-ray machine. Today s discussion will focus on the x-ray tube. In the picture, you can see the technologist handling the x-ray tube. She is manipulating the field size by adjusting a device called the collimator which is attached to the x- ray tube housing. The rectangular looking device just above the collimator is the housing for the x-ray tube. The diagram on the right shows the x-ray tube by itself. There are three major components that we will be discussing: The cathode which is negatively charged. Note its position on the diagram above. The Anode which is positively charged. And the Glass Envelope which supports the anode and cathode structures. 1

As indicated in the previous slide, the cathode structure is electrically negative. This is negative because it is a source of electrons. Note that the diagram shows a magnified view of the cathode face and it shows dual filaments. Only one filament at a time will work. The small filament is designed to be used with relatively small parts while the large filament is used when larger body parts are being x-rayed. The structure which supports the filaments is known as the focusing cup. It is designed and shaped so that when the x-ray machine is powered up, electrons will literally boil off the filament. It glows white hot and the electrons hover around the filament in a space charge until the moment of exposure and then they accelerate very rapidly towards the anode which is not very far away. This process is known as thermionic emission. Thermionic emission occurs when the technologist begins to make an exposure by pressing the ready button on the machine. This action initiates the boost phase or that part of the exposure process where the x-ray tube is being prepared for the exposure to take place. While you cannot see the actual shape of the focusing cup, it is designed such that it helps concentrate the electron stream in a pre-determined area on the Anode target area known as a focal spot. The filament has its own circuit powered by a relatively low voltage and 4 6 amperes. 2

In this slide, we have two examples of how electrons can function given two different conditions. In the model on top, you will see that because electrons repulse each other, as soon as they leave the structure, the electrons tend to spread out. This would not be conducive to good x-ray production. The spread of the electrons occurred because the focusing cup is not negatively charged. In the second model, you will notice that the cathode structure is negatively charged. This charge then forces the electrons together as they exit the cathode structure thereby ensuring that the electrons stream does strike the focal spot in a relatively small area. 3

This slide shows how a non-functioning focusing cup would result in a wide spray pattern of electrons. This would result in xrays being generated in a wide area rather than in a small focal spot which is essential for clear images. 4

With this slide, you can clearly see that the distance between the cathode and the rotating anode disc is very close. This is designed this way to ensure that the projectile electron stream has a reasonably good chance of arriving at the anode in a relatively tight pattern. If the electrons were premitted to spread out, then the x-ray production process would become very inefficient. 5

These diagrams demonstrate two operating conditions which influence the x-ray production process. Please note that the number of electrons that are released will directly influence the number of x-rays that are generated and therefore the dose of radiation also. While these diagrams show just a few electrons, the reality is that there are countless billions of electrons that are typically released during any exposure. This diagram shows how a low ma will result in fewer x-rays being produced and a high ma will result in a greater number of x-rays. The term ma is a unit of measure of electrical current that is used when the technologist selects the exposure factors. ma is one of four Prime Exposure Factors we will be discussing soon. 6

In summary,the cathode structure, contains the filament and the focusing cup. The purpose for the filament cut is to guide the electron stream to the target area on the anode. Because of the tremendous amount of heat that is generated at the cathode, the structure is made of molybdenum nickel alloy which has excellent thermal qualities. 7

The technologist has the responsibility of choosing which filament to use with any given procedure. The technologist automatically selects the filament of choice when the focal spot size is chosen. As previously mentioned, the focal spot size that is selected is based on the relative size of the part that is to be x-rayed. In general, large body parts will require the selection of the large focal spot setting and small parts, require the small focal spot. 8

The 2 nd major part of the x-ray tube is the Anode. The anode has a positive electrical charge and attracts electrons when the exposure button is pressed. The anode is actually a disc made of Tungsten because of its thermal qualities also. The disc is designed to rotate during operation. Recall how the cathode is positioned in relation to the anode and you can see that the electron stream will strike at the lower part of the disc along an area called the focal track. It is called a track because the anode rotates very fast and the idea is for the electrons to not concentrate on any given spot for any length of time. Rotation spreads the build-up of heat along the entire disc rather than just one given spot. The specific spot along the track where the electron stream strikes is called the focal spot or tube focus. The focal spot settings available are large and small. Example sizes are 2.0 millimeters square for the large size and 1.0 millimeter square for the small size. As you recall from the arrangment of the filaments, the small filament directs its electron stream to the small focus while using the large filament, directs the stream over the larger focal spot. The small focal spot is superimposed over the large one. 9

This diagram demonstrates the relative position of the anode and cathode and the resulting emission of x-rays. Note that the anode is attached to a cylindrical part known as the rotor. The rotor is actually part of a motor that is made to rotate at very high speed. In most x-ray tubes, the revolutions per minute is usually at 3,200 for standard technique settings, however if the technologist selects exposure factors that are considerably larger and therefore very hot, then the rotor can rotate at a much greater speed exceeding 5,000 rpm. The rotation of the anode ensures that not any one spot will receive successive pulses of electrons. If there was no rotation, then it is very likely that the anode face would be damaged due to high heat. 10

This photo shows the face of an anode. In this model, it shows considerable wear along the focal track. Typically, when an xray tube is new, the anode face is very shiny and smooth, however as time goes on, the wear begins as a result of the tremendous heat produced when the electrons strike the anode. The face becomes worn and rough and may eventually fail or crack. To increase the durability of the disc, it is comprised of molybdenum with the focal track imbedded in the disc. The focal spot track is made of rhenium and tungsten. The back of the anode disc is lined with graphite for improved heat loading. 11

As we discussed in the initial slides where we spoke of how x-rays are produced, it is important to note that the metal used for producing x-rays must not only have good thermal qualities, it must also be able to produce x-rays easily. To ensure that the projectile electrons have an excellent probability of x-ray production, the atoms must have a high atomic density or a good concentration of electrons. Tungsten is an excellent metal for this. It has a high atomic number of seventy-four. This increases the probability of brems and characteristic radiation. It has a very high melting point and it can dissipate its heat by radiating it out through the glass 12

The focal spots which are imbedded in the rotating anode disc are angled in such a way that when the electrons strike the anode focal track, the angle makes it easier for the x-rays to be emitted in a downward direction. Notice in this picture how the anode face has an angle. While the projectile electrons do not bounce away from the target, the angle at which it is positioned allows more x-rays to be directed toward the image receptor or film. 13

The actual dimensions of a typical focal spot may be 1 mm X 2 mm along the focal track, however depending on the angle of the anode face, this will change the appearance of the focal spot as seen from below or where the x-ray image receptor is positioned. The anode angle and the resulting appearance of the focal spot as it would appear from the image receptor is known as the Line Focus Principle. In the diagram model here please note that as the angle of the anode decreases from 17 degrees to 7 degrees, the focal spot will appear smaller because you are looking up at it at an angle or obliquely. As the angle decreases, you actually see less of the focal spot dimensions and this will actually enhance the recorded details on the image. In general, the smaller the focal spot is, either real or as changed by the line focus principle, the better the detail will be on the finished image. 14

The next component of the x-ray tube is the glass envelope. The type of glass that is used in the construction of x-ray tubes is pyrex. This is the same type of glass that is used in cookware which can tolerate tremendous heat levels. It is important to understand that when x-rays are generated, tungsten is vaporized from the target surface as well as from the filament when it is heated. As time goes on, the diameter of the filament decreases because the tungsten is being vaporized. Because the glass envelope is sealed, the vaporized tungsten will tend to settle on the inside glass surface. Specifically, the tungsten settles over the exit port of the radiation. The area of the glass envelope that is immediately under the anode is somewhat thinner to minimize the attenuation or absorption of the x-rays as they pass through this part of the tube. However, as the tube ages, more and more tungsten will coat the inside of the tube and this makes it more difficult for the x-rays to come out of the tube. To expedite cooling and to insulate the tube, it is immersed in oil to ensure that it is electrically insulated and so that the oil will also help cool down the tube during operation. The cooling of the oil is sometimes assisted with a cooling fan. 15

This diagram demonstrates the x-ray tube with all its components labeled clearly. Note that the anode is attached to the rotor by a small diameter stem. The Rotor is made of copper which is actually part of a motor that is made to rotate by the device called the stator. The stator is a set of electric coils that produces a very strong magnetic field outside of the glass envelope that in turn pulls along the copper rotor. The stator causes the rotor to rotate very fast just like any electric motor. The stator is also called an induction motor. The rotor typically spins at around 3,200 revolutions per minute, however when a large exposure setting is used, then the rotor can spin at close to ten thousand revolutions per minute. Another component that is not seen in this diagram are the bearings which permit a very smooth rotation of the anode. The bearings are very sensitive and if the x-ray tube heats up abnormally high, they can be damaged and can cause the rotor to rotate at less than 3,200 rpm. If this occurs, the target surface can be damaged or pitted. 16

This daigram shows the entire x-ray tube contained in the protective housing. The housing is usually comprised of metal such as stainless steel and it serves as a very strong support for the rather delicate x-ray tube. The red lines you see are the electrical cables that power the x-ray tube. The xray tube is placed in the housing and then the housing is filled with oil. The oil serves two major purposes: One, it helps cool the x-ray tube just like oil in your car helps cool the engine. Additionally, the oil helps insulate electrically for safety and one additional thing it does is if you notice where the primary beam exits the housing, the x-rays must pass through a small thinkness of oil before they emerge from the tube and this contributes to minimal filtration or absorption of the x-ray beam when you make an exposure. 17

Another important function that the protective housing performs is to help control any leakage radiation. As you may recall from a previous discussion, x-rays are produced isotropically or in all directions such as what you see in this diagram. The x- rays that we want to use are permitted out at the bottom of the tube as shown here, however the rest of the radiation that is traveling in other directions is absorbed by the housing itself as well as the cooling oil. 18

The last slide in this discussion demonstrates a stationary anode x-ray tube. Note that this only shows the anode part of the tube. It is called stationary because the anode does not rotate but rather remains stationary during an exposure. This is a great limiting factor that reduces its efficiency and its use. Note that the focal spot is a tungsten button that is imbedded in a copper stem. The purpose of the stem is to conduct the heat out of the xray tube. This is different compared to the rotating anode which radiates away the heat through the glass. The stationary anode tube will conduct the heat out of the tube to the surrounding oil. This type of tube does not have as much power as the rotating anode x-ray tube. A lab model of this type of tube will be demonstrated in lab. 19