MINIMALLY INVASIVE THERMAL THERAPY FOR CANCER TREATMENT BY USING THIN COAXIAL ANTENNAS



Similar documents
Thermal Effects of Mobile Phones

Biological Effects and Therapeutic Applications of Electromagnetic Radiations

Specific Absorption Rate (SAR) Induced in Human Heads of Various Sizes When Using a Mobile Phone


Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions

AN INTEGRATED SOFTWARE SYSTEM FOR MEDICAL EQUIPMENT MANAGEMENT

Deriving the 12-lead Electrocardiogram From Four Standard Leads Based on the Frank Torso Model

Effect of Metallic Materials on SAR

Real-life Applications of ICNIRP Guidelines to Various Human EMF Exposure Issues

Specific Absorption Rate (SAR) in the head of Tablet user's

Effects of Cell Phone Radiation on the Head. BEE 4530 Computer-Aided Engineering: Applications to Biomedical Processes

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz

MUCH work has been reported on determining the specific

NUMERICAL SIMULATION OF BIOHEAT TRANSFER PROCESS IN THE HUMAN EYE USING FINITE ELEMENT METHOD

FDTD Computation of Sar Distributions in Human Head for Mobile Phones V.Purushothaman, N.Vignesh, S.Vijayakumar

Human Exposure to Outdoor PLC System

Electromagnetic Radiation towards Adult Human Head from Handheld Mobile Phones

Human Exposure Limits

Non-Ionizing Electromagnetic Radiation

ANTENNA AND MICROWAVE LABORATORY

AS COMPETITION PAPER 2007 SOLUTIONS

Wideband Dual Segment Rectangular Dielectric Resonator Antenna Terminate in Bio-Media

Design of an U-slot Folded Shorted Patch Antenna for RF Energy Harvesting

Selected Radio Frequency Exposure Limits

EMR Exposure Limits & Assessment Methods for Mobile Phone Communications. Lindsay Martin Manager, Non-Ionising Radiation Section

Microwave Interstitial Tumor Ablation: New Modality for Treatment of Liver Cancer

A study on specific absorption rate (SAR) due to non-ionizing radiation from wireless/telecommunication in Bangladesh

Electromagnetic Field Safety

National Laboratory of Antennas and Microwave Technology Xidian University Xi an, Shaanxi , China

THREE DIMENSIONAL REPRESENTATION OF AMINO ACID CHARAC- TERISTICS

Low SAR planar antenna for multi standard cellular phones

Environmental Health and Safety

Assessment of SAR in a human exposed to GSM electromagnetic fields

Wireless Broadband: Health & Safety Information

EVALUATION OF SAR AND TEMPERATURE ELEVATION IN A MULTI-LAYERED HUMAN HEAD MODEL EXPOSED TO RF RADIATION. By Ayman Ibrahim Sabbah

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS

Harmful effects of 41 and 202 MHz radiations on some body parts and tissues

T-slot Broadband Rectangular Patch Antenna

SIW 2D PLANAR ARRAY WITH FOUR CROSS SLOTS RADIATOR AND TUNING VIAS

THE ANSI/IEEE RF SAFETY STANDARD AND ITS RATIONALE. Om P. Gandhi and Gianluca Lazzi Department of Electrical Engineering Salt Lake City, Utah 84112

SAR Simulation in Human Head Exposed to RF Signals and Safety Precautions

AN OVERVIEW OF STANDARDS AND REGULATION CONCERNING EXPOSURE TO RADIOFREQUENCY FIELDS

SR Communications Tower Task Force Dr. Jeff Liva, Allen Cohen, Rebecca Rogers

MRET-Shield Synopsis of Scientific Research Updated on June 1, 2007

SAR REDUCTION IN HUMAN HEAD FROM MOBILE PHONE RADIATION USING SINGLE NEGATIVE META- MATERIALS

Enhanced Stripline Scanning Array B.M. Cahill and J.C. Batchelor

Research Article Thermal Analysis of head with Exposure to Electromagnetic Mobile Waves Shahrokh Shojaei l, Nasser Fatouraei l, Gholamreza Ataei 2 * 1

COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (1999/519/EC)

Advanced Measurements of Microwave Oven Leakage

Operating Frequency Selection for Loosely Coupled Wireless Power Transfer Systems with Respect to RF Emissions and RF Exposure Requirements

5-3 Development of Exposure Systems and Exposure Assessment for Studies on Biological Effect of Electromagnetic Fields

ANALYSIS AND VERIFICATION OF A PROPOSED ANTENNA DESIGN FOR AN IMPLANTABLE. RFID TAG AT 915 MHz RAHUL BAKORE

ASSESSMENT OF HUMAN HEAD EXPOSURE TO WIRELESS COMMUNICATION DEVICES: COMBINED ELECTROMAGNETIC AND THERMAL STUDIES FOR DIVERSE FREQUENCY BANDS

BARE PCB INSPECTION BY MEAN OF ECT TECHNIQUE WITH SPIN-VALVE GMR SENSOR

Power Rating Simulation of the new QNS connector generation

ARIB TR-T V Specific Absorption Rate (SAR) requirements and regulations in different regions

Analysis of Blind Microvias Forming Process in Multilayer Printed Circuit Boards

by Hiroyuki Tamaoka *, Hiroki Hamada * and Takahiro Ueno * 1. INTRODUCTION 2. DEVELOPMENTAL TASKS

Attenuation Measurements of Materials Used in Construction of Buildings

Connected U-Slots Patch Antenna for WiMAX Applications

Temperature Increase in the. Human Eye When Subjected to a. Laser Source

Consequence for a dualband application

Insight on mobile phones and communication system:

RADIOFREQUENCY RADIATION, (RFR): (RFR Information - Technology Newsletter, Full Version)

Official Journal of the European Communities. (Acts whose publication is not obligatory) COUNCIL

Software for Design NMR Probes Using the Shielded Split Ring and the Shielded Symmetrical Band Resonators

A New Concept of PTP Vector Network Analyzer

Numerical Modelling of E-M Occupational Exposures associated with MRI

A Novel Multi Frequency Rectangular Microstrip Antenna with Dual T Shaped Slots for UWB Applications

Design and Electromagnetic Modeling of E-Plane Sectoral Horn Antenna For Ultra Wide Band Applications On WR-137 & WR- 62 Waveguides

CITY UNIVERSITY OF HONG KONG. A Study of Electromagnetic Radiation and Specific Absorption Rate of Mobile Phones with Fractional Human Head Models

Introduction to antenna and near-field simulation in CST Microwave Studio software

BIOMEDICAL ULTRASOUND

Interaction of Mobile Phone Waves with Tissues of Skeletal Muscles and Bone of Human Beings

Cables and Connectors. PRINCIPLES OF LEAKY FEEDER ANTENNAS Franz Hirtenfelder and Stephen Murray

Proposal for a Slot Pair Array Having an Invariant Main Beam Direction with a Cosecant Radiation Pattern Using a Post-Wall Waveguide

Antonio Rampoldi Struttura Complessa di Radiologia Interventistica Azienda Ospedale Niguarda Ca Granda, Milano. Terminology

REVIEW OF EXPOSURE LIMITS AND HEALTH CONCERNS SANTA ANA. Base Station Telecommunication Transmitters UNIFIED SCHOOL DISTRICT

Electromagnetic Wave Simulation Software Poynting

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

1 Introduction. JS'12, Cnam Paris, 3-4 Avril Ourouk Jawad 1, David Lautru 2, Jean Michel Dricot, François Horlin, Philippe De Doncker 3

Design of Ultra-High-Density 2000-Optical Fiber Cable with Pliable 8-fiber Ribbons for Underground Deployment

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

GPR Polarization Simulation with 3D HO FDTD

Numerical Analysis of Transient Phenomena in Electromagnetic Forming Processes

Patient Guide. Brachytherapy: The precise answer for tackling breast cancer. Because life is for living

Designer-Oriented Electric Field Analysis System for Power Cable Accessories

A wave lab inside a coaxial cable

Printed Dipole Array Fed with Parallel Stripline for Ku-band Applications

A Study of RF Absorber for Anechoic Chambers Used in the Frequency Range for Power Line Communication System

Human exposure to RF

Composite Electromagnetic Wave Absorber Made of Permalloy or Sendust and Effect of Sendust Particle Size on Absorption Characteristics

Transcription:

MINIMALLY INVASIVE THERMAL THERAPY FOR CANCER TREATMENT BY USING THIN COAXIAL ANTENNAS K. Ito 1, K. Saito 1, T. Taniguchi 2, S. Okabe 2, and H. Yoshimura 1 1 Faculty of Engineering, Chiba University, Chiba, Japan 2 Graduate School of Science and Technology, Chiba University, Chiba, Japan Abstract - In recent years, various types of applications of electromagnetic techniques for microwave thermal therapy have been developed. Among them, minimally invasive microwave thermal therapies for cancer are of great interest. They are interstitial microwave hyperthermia and microwave coagulation therapy. In this paper, we describe the characteristics of thin coaxial antennas for those therapies. Keywords - Minimally invasive microwave thermal therapy, hyperthermia, microwave coagulation therapy, thin coaxial antenna Then, radiation sources such as the iridium 192 are automatically inserted into the catheters by a high dose rate afterloading system. Interstitial microwave hyperthermia Thin coaxial antenna I. INTRODUCTION In recent few decades, various types of medical applications of microwaves have widely been investigated and reported [1]. In particular, minimally invasive microwave thermal therapies using thin applicators are of great interest. They are interstitial microwave hyperthermia [2] and microwave coagulation therapy (MCT) for medical treatment of cancer [3], cardiac catheter ablation for ventricular arrhythmia treatment [4], and so on. The authors have been studying thin coaxial antennas for the interstitial microwave hyperthermia and the MCT. In this paper, first, we describe the heating characteristics of the antennas for the interstitial microwave hyperthermia, particularly, in the case of combining the hyperthermia and the interstitial radiation therapy. Next, we show the modality of the MCT and some problems of conventional antennas. Moreover, we introduce a new type of antenna for the MCT to solve one of the problems. II. INTERSTITIAL MICROWAVE HYPERTHERMIA Interstitial radiation therapy Radiation source Fig. 1. Combined therapy. Feed (2,45 MHz) Same catheter A. Interstitial Microwave Hyperthermia and Interstitial Radiation Therapy Hyperthermia is one of the modalities for cancer treatment, utilizing the difference of the thermal sensitivity between tumor and normal tissue. In this treatment, the tumor or target cancer cell is heated up to the therapeutic temperature between 42 and 45 o C without overheating surrounding normal tissues. Particularly, combination of the interstitial hyperthermia and the interstitial radiation therapy is effective for treatment of radiation resistive tumor [2]. Figure 1 shows the treatment system of the combined therapy. This treatment system is realized by using the same catheters between the interstitial hyperthermia and the interstitial radiation therapy. In this system, firstly, thin microwave antennas such as the coaxial-slot antenna [5] with catheter heat the tumor. After heating, only the antennas are pulled out of the catheters. 14. Unit: [mm] 7. Coaxial cable Catheter 1.19 1.79 L ts 1. Air Short-circuited Fig. 2. Basic structure of the coaxial-slot antenna.

Report Documentation Page Report Date 25 Oct 21 Report Type N/A Dates Covered (from... to) - Title and Subtitle Minimally Invasive Thermal Therapy for Cancer Treatment by Using Thin Coaxial Antennas Contract Number Grant Number Program Element Number Author(s) Project Number Task Number Work Unit Number Performing Organization Name(s) and Address(es) Faculty of Engineering Chiba University Chiba, Japan Sponsoring/Monitoring Agency Name(s) and Address(es) US Army Research, Development & Standardization Group (UK) PSC 82 Box 15 FPO AE 9499-15 Performing Organization Report Number Sponsor/Monitor s Acronym(s) Sponsor/Monitor s Report Number(s) Distribution/Availability Statement Approved for public release, distribution unlimited Supplementary Notes Papers from 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, October 25-28, 21, held in Istanbul, Turkey. See also ADM1351 for entire conference on cd-rom., The original document contains color images. Abstract Subject Terms Report Classification Classification of Abstract Classification of this page Limitation of Abstract UU Number of Pages 4

B. Heating Characteristics of the Coaxial- Antennas for the Combined Therapy The authors have studied the coaxial-slot antennas for the interstitial heating. Figure 2 shows the basic configuration of the coaxial-slot antenna. This antenna is composed of thin semirigid coaxial cable. A ring slot is cut on the outer conductor of a thin coaxial cable and the tip of the cable is shortcircuited. L ts is the length from the tip to the center of the slot. The operating frequency is 2,45 MHz that is the one of the ISM (Industrial, Scientific, and Medical) frequencies. In order to obtain the large heating region, we use the array applicator, which is composed of some antennas. Therefore, we employed the array applicator composed of four coaxial-slot antennas. In this paper, we analyze the heating characteristics of the array applicator by the numerical simulation. First, we calculate the SAR (specific absorption rate) distribution around the antenna from σ 2 SAR = E [W/kg] (1) ρ where σ is the conductivity of the tissue [S/m], ρ is the density of the tissue [kg/m 3 ], and E is the electric field (rms) [V/m]. The SAR takes a value proportional to the square of the electric field around the antennas and is equivalent to the heating source generated by the electric field in the tissue. The SAR distribution is one of the most important characteristics of the antennas for the heating. Figure 3 (a) shows the calculated SAR distribution of the array applicator composed of four coaxial-slot antennas, which is inserted into a muscle (ε r =47., σ =2.21 S/m at 2,45 MHz). Here, Fig. 3 (b) shows the SAR observation plane. In this calculation, L ts and the array space A s were set to 5 mm and 15 mm, respectively. From Fig. 3 (a), we can observe the high SAR regions exist not only near each antenna but also at center of the array applicator. The high SAR regions at the center of the array applicator are caused by the mutual coupling between each antenna element. TABLE I PARAMETERS FOR TEMPERATURE CALCULATION. Muscle Specific heart c [J/kg K] 3,5 Thermal conductivity κ [W/m K].6 Density ρ [kg/m 3 ] 1,2 Blood Specific heart c b [J/kg K] 3,96 Density ρ b [kg/m 3 ] 1,6 Blood flow rate F [m 3 /kg s] 8.33 1-6 Temperature of the blood T b [ o C] 37. Others Initial temperature [ o C] 37. Heating time [s] 6 Net input power (total of the array) [W] 12. Next, we calculate the temperature distribution around the array applicator. In order to obtain the temperature distribution in the tissue, we numerically analyze the bioheat transfer equation [6] including the obtained SAR values by using the FEM (finite element method). The bioheat transfer equation is given by T 2 ρ c = κ T ρ ρ c F ( T T ) + ρ SAR (2) b b b t where T is the temperature [ o C], t is the time [s], ρ is the density [kg/m 3 ], c is the specific heat [J/kg K], κ is the thermal conductivity [W/m K], ρ b is the density of the blood [kg/m 3 ], c b is the specific heat of the blood [J/kg K], T b is the temperature of the blood [ o C], and F is the blood flow rate [m 3 /kg s]. Figure 4 shows the temperature distributions around the array applicator composed of four coaxial-slot antennas. Here, the temperature observation plane is the same as Fig. 3 (b). The parameters of the temperature calculation are listed in Table I. From this figure, we can observe a large and uniform heating region though the result of the SAR distribution, which is shown in Fig. 3 (a), is not uniform. This result clearly shows that the array applicator is useful for developing the treatment system combining the interstitial microwave hyperthermia and the interstitial radiation therapy. 2 High A s y z A s x 4 6 8 SAR Low -2 2 Observation plane x [mm] (b) Observation plane. (a) SAR distribution. Fig. 3. SAR distribution of the array applicator composed of four coaxial-slot antennas.

2 4 6 42 o C 5 48 46 44 42 4 Temperature [ o C] 38 8-2 2 x [mm] Fig. 4. Temperature distribution of the array applicator composed of four coaxial-slot antennas. III. MICROWAVE COAGULATION THERAPY A. Scheme of the MCT The MCT has been used mainly for the treatment of hepatocellular carcinoma. Figure 5 shows the scheme of the MCT. In the treatment, thin microwave antenna is inserted into the tumor and the microwave energy heats up the tumor to produce the coagulated region including the cancer cells. We have to heat the cancer cells up to at least 6 o C above which the cells are coagulated. At present, there are some problems to be improved for the conventional MCT antennas. Particularly, there is a problem that length of the coagulated region becomes long in the antenna insertion direction. In this paper, we employed the coaxial-dipole antenna [7], [8] to solve this problem. Ultrasound guide B. Coaxial-Dipole Antenna Antenna Skin Microwave Fig. 5. Scheme of the MCT. Figure 6 shows the structure of the coaxial-dipole antenna. This antenna corresponds to the coaxial-slot antenna united with two conductive sleeves. The sleeves are connected on the both side of the slot. In this time, the length of the sleeves was set to 2 mm. 14. 2. Feed (245 MHz) Coaxial cable Catheter.86 2.65 z Air 2. 1. Dielectric.86 2.19 Sleeves Short-circuited Longitudinal cross section of the tip of the antenna Unit: [mm] Fig. 6 Basic structure of the coaxial-dipole antenna. C. FDTD Calculations We investigated the SAR distribution of the coaxial-dipole antenna by using the FDTD method. Figure 7 (a) shows the normalized SAR distributions of the coaxial-dipole antenna. In addition, the SAR distribution around the coaxial-slot antenna is also presented in Fig. 7 (b) for comparison (the L ts of the antenna is 1 mm). From the result, we can observe the welllocalized SAR profile at the tip of the coaxial-dipole antenna in comparison with that of the coaxial-slot antenna. In order to understand the mechanism of generating the localized heating by the coaxial-dipole antenna, the current distribution on the antenna is calculated. Figure 8 shows the current distributions on the antenna. Figure 8 (a) and (b) show the current distribution on the coaxial-dipole antenna and the coaxial-slot antenna, respectively. In the FDTD calculation, the current distribution is defined as the strength of magnetic field in the orthogonal direction to the antenna axis. From Fig. 8, in the coaxial-dipole antenna, a localized distribution appears around the sleeves, compared with the current distribution on the coaxial-slot antenna. The localized current distribution generates the localized SAR distributions around the sleeves. IV. CONCLUSION In this paper, we described the characteristics of the thin coaxial antennas for the minimally invasive microwave thermal therapies for cancer. First, we showed the heating characteristics of the array applicator for the interstitial microwave hyperthermia combined with the interstitial radiation therapy. Next, we explained the scheme of the MCT, and introduced a solution for the problem of the conventional antenna. As a further study, we are going to reveal the effectiveness of the antennas by conducting the animal experiments.

SAR (normalized) SAR (normalized) 1..8.6.4 Sleeves.2 2 4 6 8 (a) Coaxial-dipole antenna. 1..8.6.4.2 2 4 6 8 (b) Coaxial-slot antenna. Fig. 7. SAR distributions. The observation line is the line of the longitudinal direction of the antenna at the distance of 3. mm away from the antenna axis. Amplitude (normalized) 1..8.6.4 Sleeves.2 2 4 6 8 (a) Coaxial-dipole antenna. ACKNOWLEDGEMENT The authors would like to thank to Dr. Yutaka Aoyagi and Mr. Hirotoshi Horita from Tokyo Dental College, Ichikawa General Hospital for their useful discussion. REFERENCES [1] K. Ito, Medical applications of microwave, Proc. APMC 96, vol. 1, pp. 257-26, December 1996. [2] M. H. Seegenschmiedt, P. Fessenden, and C. C. Vernon, eds., Thermoradiotherapy and Thermochemotherapy, vol. 1, Berlin: Springer-Verlag, 1995. [3] T. Seki, M. Wakabayashi, T. Nakagawa, T. Itoh, T. Shiro, K. Kunieda, M. Sato, S. Uchiyama, and K. Inoue, Ultrasonically guided percutaneous microwave coagulation therapy for small carcinoma, Cancer, vol. 74, pp. 817-825, August 1994. [4] S. Labonté, A. Blais, S. R. Legault, H. O. Ali, and L. Roy, Monopole antennas for microwave catheter ablation, IEEE Trans. Microwave Theory Tech., vol. 44, no. 1, pp. 1832-184, October 1996. [5] K. Ito, K. Ueno, M. Hyodo, and K. Kasai, Interstitial applicator composed of coaxial ring slots for microwave hyperthermia, Proc. 1989 ISAP, vol. 2, pp. 253-256, August 1989. [6] H. H. Pennes, Analysis of tissue and arterial blood temperatures in the resting human forearm, J. AppL. Phys., vol. 1, pp. 93-122, 1948. [7] K. Iwata, K. Udagawa, M. S. Wu, K. Ito, and H. Kasai, A basic study of coaxial-dipole applicator for microwave interstitial hyperthermia, Proc. 12th Annu. Meeting of the Japanese Society of Hyperthermic Oncol., pp. 23-231, September 1995. [8] K. Saito, S. Hosaka, T. Taniguchi, H. Yoshimura, and K. Ito, Improvement of heating patterns by using a coaxialdipole antenna for microwave coagulation therapy, Dig. USNC/URSI National Radio Science Meeting 2, p. 157, July 2. Amplitude (normalized) 1..8.6.4.2 2 4 6 8 (b) Coaxial-slot antenna. Fig. 8. Current distributions on the antenna.