MITIGATION OF EARTHQUAKE INDUCED GEOTECHNICAL DISASTERS USING A SMART AND NOVEL GEOMATERIAL

Similar documents
Drained and Undrained Conditions. Undrained and Drained Shear Strength

Figure CPT Equipment

SEISMIC DESIGN OF HIGHWAY BRIDGES

EARTH PRESSURE AND HYDRAULIC PRESSURE

COSMOS 2012: Earthquakes in Action COSMOS 2012

Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,

Numerical Simulation of CPT Tip Resistance in Layered Soil

STABILITY ANALYSIS OF AN EARTH DAM FOUNDATION IN TUNISIA

SEISMIC CAPACITY OF EXISTING RC SCHOOL BUILDINGS IN OTA CITY, TOKYO, JAPAN

CHAPTER 9 FEM MODELING OF SOIL-SHEET PILE WALL INTERACTION

INTRODUCTION TO SOIL MODULI. Jean-Louis BRIAUD 1

Strengthening of Brick Masonry Walls against Earthquake Loading

DEVELOPMENT AND APPLICATIONS OF TUNED/HYBRID MASS DAMPERS USING MULTI-STAGE RUBBER BEARINGS FOR VIBRATION CONTROL OF STRUCTURES

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

Program COLANY Stone Columns Settlement Analysis. User Manual

NORMALIZATION OF STRESS-STRAIN CURVES FROM CRS CONSOLIDATION TEST AND ITS APPLICATION TO CONSOLIDATION ANALYSIS

Effect of grain size, gradation and relative density on shear strength and dynamic cone penetration index of Mahi, Sabarmati and Vatrak Sand

SEISMIC SETTLEMENT OF SHALLOW FOUNDATIONS

DESIGN SPECIFICATIONS FOR HIGHWAY BRIDGES PART V SEISMIC DESIGN

A PERFORMANCE TEST STUDY ON CHINESE G4 LEAD RUBBER BEARINGS

Soil Mechanics. Outline. Shear Strength of Soils. Shear Failure Soil Strength. Laboratory Shear Strength Test. Stress Path Pore Pressure Parameters

4.3 Results Drained Conditions Undrained Conditions References Data Files Undrained Analysis of

Module 7 (Lecture 24 to 28) RETAINING WALLS

DIRECT SHEAR TEST SOIL MECHANICS SOIL MECHANICS LABORATORY DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF MORATUWA SRI LANKA

Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE

A Theoretical Solution for Consolidation Rates of Stone Column-Reinforced Foundations Accounting for Smear and Well Resistance Effects

Comparison of Seismic Retrofitting Methods for Existing Foundations in Seismological Active Regions

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

Secondary Consolidation and the effect of Surcharge Load

CONSOLIDATION

DEM modelling of the dynamic penetration process on Mars as a part of the NASA InSight Mission

Soil Mechanics SOIL STRENGTH page 1

Development of Seismic-induced Fire Risk Assessment Method for a Building

Measurement of Soil Parameters by Using Penetrometer Needle Apparatus

METHOD OF STATEMENT FOR STATIC LOADING TEST

KWANG SING ENGINEERING PTE LTD

PDCA Driven-Pile Terms and Definitions

Methods for Seismic Retrofitting of Structures

EXPERIMENT 10 CONSTANT HEAD METHOD

Mechanically stabilized layers in road construction

Ground improvement using the vibro-stone column technique

SEISMIC DAMAGE ESTIMATION PROCEDURE FOR WATER SUPPLY PIPELINES

SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT

CEEN Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests

SEISMIC RETROFITTING OF STRUCTURES

Analysis of Retaining Wall Subjected to Earthquake Loading

Soil Mechanics. Soil Mechanics

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

Important Points: Timing: Timing Evaluation Methodology Example Immediate First announcement of building damage

Consolidation Characteristics of Wastewater Sludge

Interpretation of clogging effects on the hydraulic behavior of ion treated geotextiles

Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing

Seismic Risk Prioritization of RC Public Buildings

Control of Seismic Drift Demand for Reinforced Concrete Buildings with Weak First Stories

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope

ESTIMATION OF UNDRAINED SETTLEMENT OF SHALLOW FOUNDATIONS ON LONDON CLAY

c. Borehole Shear Test (BST): BST is performed according to the instructions published by Handy Geotechnical Instruments, Inc.

CRACK DETECTION METHODS USING RADIO FREQUENCY IDENTIFICATION AND ELECTRICALLY CONDUCTIVE MATERIALS

Seismic Isolation Retrofitting of Japanese Wooden Buildings

Practice of rapid load testing in Japan

Soil Strength. Performance Evaluation of Constructed Facilities Fall Prof. Mesut Pervizpour Office: KH #203 Ph: x4046

Mechanisms of Seismically Induced Settlement of Buildings with Shallow Foundations on Liquefiable Soil

Evaluation of Post-liquefaction Reconsolidation Settlement based on Standard Penetration Tests (SPT)

When to Use Immediate Settlement in Settle 3D

SEISMIC UPGRADE OF OAK STREET BRIDGE WITH GFRP

SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS

EN Eurocode 7. Section 10 Hydraulic Failure Section 11 Overall Stability Section 12 Embankments. Trevor L.L. Orr Trinity College Dublin Ireland

Benchmarking Multi-Dimensional Large Strain Consolidation Analyses D. Priestley 1, M.D. Fredlund 2 and D. van Zyl 3

6 RETROFITTING POST & PIER HOUSES

Seismic Analysis and Design of Steel Liquid Storage Tanks

Period #16: Soil Compressibility and Consolidation (II)

PART TWO GEOSYNTHETIC SOIL REINFORCEMENT. Martin Street Improvements, Fredonia, Wisconsin; Keystone Compac Hewnstone

Seismic performance evaluation of an existing school building in Turkey

Methods for Land Reclamation using Soft Soil and Waste

Open Access Numerical Analysis on Mutual Influences in Urban Subway Double-Hole Parallel Tunneling

Penetration rate effects on cone resistance measured in a calibration chamber

Liner system design for tailings impoundments and heap leach pads

ABSG Consulting, Tokyo, Japan 2. Professor, Kogakuin University, Tokyo, Japan 3

CE 366 SETTLEMENT (Problems & Solutions)

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

NUMERICAL MODELLING OF PIEZOCONE PENETRATION IN CLAY

International Journal of Engineering Research-Online A Peer Reviewed International Journal Articles available online

Pullout Testing of Xgrid PET PVC 40/20 IT and Xgrid PET PVC 80/30 IT In Sand

Settlement and Load Sharing Behavior of Piled Raft Foundations Based on Long-Term Monitoring 長 期 挙 動 観 測 に 基 づくパイルド ラフト 基 礎 の 沈 下 と 荷 重 分 担 挙 動

Specification Guidelines: Allan Block Modular Retaining Wall Systems

Cone Penetration Testing in Geotechnical Practice. Tom Lunne Peter K. Robertson John J.M. Powell

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

PAPAMOA EAST URBAN DEVELOPMENT PART 1 AREA LIQUEFACTION HAZARD REVIEW Technical Report

vulcanhammer.net This document downloaded from

Acoustic Porous Materials and Their Characterisation

1 Mobilisation and demobilisation 1 Deep boring sum 2 Cone penetration tests sum 3 Miscellenous tests sum

Settlement of Precast Culverts Under High Fills; The Influence of Construction Sequence and Structural Effects of Longitudinal Strains

Tensile Testing of Steel

SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS

Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur

Transcription:

MITIGATION OF EARTHQUAKE INDUCED GEOTECHNICAL DISASTERS USING A SMART AND NOVEL GEOMATERIAL H. Hazarika 1, K. Yasuhara 2, M. Hyodo 3, A. K. Karmokar 4 and Y. Mitarai 5 1 Associate Professor, Dept. of Architecture and Environment System, Akita Prefectural University, Akita, Japan 2 Professor, Dept. of Urban and Civil Engineering, Ibaraki University, Ibaraki, Japan 3 Professor, Dept. of Civil & Environmental Engineering, Yamaguchi University, Ube, Japan 4 Senior Research Engineer, Central Research, Bridgestone Corporation, Tokyo, Japan 5 Senior Researcher, Toa Research & Development Center, Toa Corporation, Yokohama, Japan Emails:hazarika@akita-pu.ac.jp, yasuhara@mx.ibaraki.ac.jp, hyodo@yamaguchi-u.ac.jp ABSTRACT: In this paper, an innovative disaster mitigation technique is described in which scrap tire derived recycled wastes are utilized to reduce the earthquake related hazards of geotechnical structures. A series of model 1G shaking table experiments were conducted to validate the performance of the developed technique. The test results have demonstrated that the mitigation technique not only reduces the seismic load but also the earthquake induced permanent displacement of structures. Such mitigation measure also can lead to cost-effective design and retrofitting of geotechnical structures by reducing the material and construction cost. KEYWORDS: Liquefaction, Quay wall, Seismic retrofitting, Shake table test, Tire chips 1. INTRODUCTION In the 21st century, cost, environment and seismic performance are going to be the three most decisive factors in the design, construction and retrofitting of infrastructures against earthquake loading. Fears loom large over three large-scale devastating earthquakes (Tokai Earthquake, Tonankai-Nankai Earthquake, Strong metropolitan Earthquake) that are predicted to strike the Tokai area, the Nankai area and the Kanto area of Japan any time in the near future. The central disaster management council, government of Japan (http://www.bousai.go.jp, 2006), have been making concerted efforts designed to mitigate the disasters and minimize the economic implications from these earthquakes. With tough government policy of cutting expenditure on infrastructural projects, demands on engineers are mounting for developing novel and cost-effective disaster mitigation technique that can protect and reduce the damages of geotechnical structures during devastating earthquakes. This research is an attempt towards achieving a better seismic performance of geotechnical structures using a less expensive and recycled geomaterial. The recycled geomaterials, which are of interest here, are the scrap tire derived geomaterials such as tire chips and tire shreds. They are obtained by cutting scrap tires into small pieces (Figure 1). These recycled materials are lightweight, elastic, compressible, highly permeable, earthquake resistant, thermally insulating and durable. Because of such beneficial characteristics, Hazarika (2007) coined the term smart geomaterials to describe these materials. They have been increasingly used worldwide in various geotechnical constructions. Although technological advancement in Japan regarding the effective use of scrap tires as geomaterials is still in its infancy, researches on their application as tire chip-mixed solid ified soil (Kikuchi et al., 2006), earthquake-resistant reinforcement (Hazarika et al. 2006) and fill improvement (Mitarai et al., 2006) have been actively conducted. The Japanese experiences on these novel and smart geomaterials have been described in Yasuhara et al. (2006). A compilation of technical information relating to worldwide research and application of the scrap tire derived recycle materials can be found in Hazarika and Yasuhara (2007).

(b) Rubber (c) Tire chips (a) Scrap tires (d) Tire shreds Figure 1. Tire derived geomaterials On the other hand, concerns have been growing on the seismic stability of the existing and newly built port and harbor facilities in Japan after her bitter experiences of the 1995 Hyogoken-Nanbu earthquake, Kobe. The earthquake caused severe damage to more than 90% of the waterfront structures (Inagaki et al., 1996; Ishihara, 1997; JGS/JSCE, 1996; Kamon et al, 1996; Towhata et al., 1996). Typical waterfront structure such as gravity type quay wall has rubble backfill immediately behind the wall. One of the reasons for using rubble backfill is to reduce the earth pressure due to friction. However, such granular material is vulnerable to deformation under seismic load, and hence can induce large permanent deformations to the structures. If we can substitute this material with smart geomaterials such as tire chips, then the earth pressure during earthquake can be reduced to a greater extent along with the curtailment of earthquake induced permanent deformation of the structures. In this research, an innovative cost-effective disaster mitigation technique is developed using tire chips, the emerging geomaterial, which can be utilized as a seismic performance enhancer of geotechnical structures. The objective of this research is to examine whether the developed mitigation technique can reduce the earthquake related damages to geotechnical structures. To that end, an underwater shaking table test (1G condition) was performed using the actual earthquake loading of the 1995 Hyogoken-Nanbu earthquake, Kobe and the structural performances under such level 2 earthquake motion (PIANC, 2001) were investigated. 2. OUTLINE OF THE MITIGATION TECHNIQUE Figure 2 shows typical cross section of the earthquake hazard mitigation technique that is being developed. First step of the novel technique involves placing cushion layer made out of tire chips as a vibration absorber immediately behind the structures (Hazarika, 2007). In addition, vertical drains made out of tire chips are installed in the backfill as a preventive measure against soil liquefaction. Yasuhara et al. (2004) used such tire chips as vertical drains for reducing liquefaction induced deformation. One function of the cushion is to reduce the load against the structure, due to energy absorption capacity of the cushion material. Another function is to curtail permanent displacement of the structure due to inherited flexibilities derived from using such elastic and compressible material. 3. 1G SHAKING TABLE TEST 3.1. Test setup The large three dimensional underwater shaking table assemblies of Port and Airport Research Institute (PARI) were used in the testing program. The shaking table is mounted on a 15 m long by 15 m wide and 2.0 m deep water pool, and thus can simulate the actual state of waterfront structure.

Gravity-type Structure Tire Chips Cushion Drainage Mat Caisson Backfill Foundation Rubble Foundation Soil Tire Chips Drain Figure 2. Outline of the developed earthquake hazard mitigation technique A caisson type quay wall (model to prototype ratio of 1/10) was used in the testing. Figure 3 shows the cross section of the soil box, the model caisson and the locations of the various measuring devices (load cells, earth pressure cells, pore water pressure cells, accelerometers and displacement gauges). The model caisson (425 mm in breadth) was made of steel plates filled with dry sand and sinker to bring its center of gravity to a stable position. The caisson consists of three parts; the central part (width 500 mm) and two dummy parts (width 350 mm each). All the monitoring devices were installed at the central caisson to eliminate the effect of sidewall friction on the measurements. A B Figure 3. Cross section of the test model The soil box was made of a steel container 4.0 m long, 1.25 m wide and 1.5 m deep. The foundation rubble beneath the caisson was prepared using Grade 4 crushed stone with particle size of 13 mm ~ 20 mm. Backfill (Sohma sand No. 5) was prepared in stages using free falling technique, and then compacting using a manually operated vibrator to achieve the target relative density of 50%. After constructing the foundation and the backfill, and setting up of the devices, the pool was filled with water gradually elevating the water depth to 1.3 m to saturate the backfill. This submerged condition was maintained for two days so that the backfill attains a complete saturation stage.

3.2. Materials and their dynamic properties The backfill and the seabed layer were prepared using Sohma sand (No. 5). The tire chips cushion layer was prepared from tire chips of average grain size 20 mm. The vertical drains were made out of tire chip of average grain size 7.0 mm. Hyodo et al. (2007) conducted undrained shear testing of Sohma sand and tire chips mixtures to understand the shear behavior and strength characteristics of these materials under cyclic loading conditions. Typical results obtained from the undrained cyclic triaxial tests for Sohma sand and tire chips are shown in Figure 4 in terms of the deviator stress (q) - axial strain (ε a ) relation, respectively. The physical properties of the tested materials are shown in Table 1. It is to be noted that in these element tests, tire chips of average grain size less than 2.0 mm were used due to limitation of the triaxial testing machines, whereas in the model tests much bigger sizes of tire chips were used. In the experiment, two levels of compaction energy (E c =51kJ/m 3, 116 kj/m 3 ) were used to obtain different relative densities. The saturated specimens were isotropically consolidated under a confining pressure of σ c =100 kpa and undrained triaxial tests were conducted at a loading frequency of 0.1 Hz. D e v ia t o r st r e ss, q (k P a ) 80 40 0-40 sf=1 ( Soma sand) σ d/ 2σ c'=0.26 Ec=166kJ/m 3 σ c'=10 0kPa e =0.8 74-80 -10-5 0 5 10 Axial strain, ε a (%) 80 40 0-40 sf= 0 ( Tire chip s) σd/2σc '=0.17 σ c '=100kPa -80-10 -5 0 5 10 Axia l st rain, εa (% ) Ec=166kJ/m 3 e=0.395 Cyc lic dev ia tor s tr es s ratio,σ d/2σ c ' 0.4 0.3 0.2 0.1 : εda=1% : εda=2% : εda=5% sf=0 εda was not dev eloped up t o 5% solid s ym bol : Ec=166k J/m 3 (eav erag e=0.404) ( Tire chips ) σ c' =100kP a blank s ym bol : E c=51kj/m 3 (eav er ag e=0.735) 0.0 0.01 0.1 1 10 10 0 Number of cycles, N (cycle) (a) Sohma sand (b) Tire chips Figure 4. Typical results of undrained cyclic shear tests Figure 5. Cyclic shear stress and the number of cycles required to produce the double amplitude Table 1. Physical Properties of soil samples (After Hyodo et al., 2007) Sand fraction ρ s (g/cm 3 ) ρ dmin (g/cm 3 ) ρ dmax (g/cm 3 ) e max e min D 50 (mm) U c sf=1(soma sand) 2.645 1.273 1.574 1.077 0.680 0.395 1.65 sf=0.9 2.576 - - - - 0.399 1.67 sf=0.8 2.498 - - - - 0.403 1.67 sf=0.7 2.410 0.939 1.234 1.565 0.953 0.407 1.69 sf=0.6 2.309 - - - - 0.414 1.72 sf=0.5 2.192 0.744 0.988 1.948 1.218 0.423 1.75 sf=0.3 1.892 0.563 0.735 2.361 1.576 0.453 1.91 sf=0 (Tire chips) 1.150 0.347 0.442 2.318 1.600 0.655 2.72 The relationship between the deviator stress and axial strain showed visco-elastic behavior of tire chips. From Figure 4, it is evident that tire chips show linear behavior when the axial strain is less than 1%. However, axial strain as large as 2% occurred during the first cycle. Figure 5 shows the plots of cyclic shear stress ratio, σ d /2σ c and the number of cycles N required to produce the double amplitude axial strain of ε da =1%, 2% and 5%. In the figure, e average corresponds to the average void ratio of each specimen after consolidation at σ c = 100 kpa. It can be seen from this figure that the relationship practically lies on the same curve, indicating that compaction

energy has almost no contribution to the dynamic strength of tire chips specimen. The results of the test series conducted by Hyodo et al. (2007) have confirmed that excess pore wate r pressure does not generate inside tire chips, and hence, liquefaction does not occur. Therefore, such material has enormous potential in mitigating liquefaction when used them as drainage materials. 3.3. Test procedures Two test cases were examined using the same soil box by mounting two gravity type model quay walls with different backfill conditions. In one case, a caisson with a rubble backfill with conventional sandy backfill behind it was used. In another case, behind the caisson, a cushion layer of tire chips (average grain size 20 mm) was placed vertically down. Also, vertical drains made out of tire chip (average grain size 7.0 mm), were installed in the backfill as shown in Figure 3. The cushion thickness was adopted to be 0.4 times of the wall height. In actual practice, the design cushion thickness will depend upon a lot of other factors such as height and rigidity of the structure, compressibility and stiffness of the cushion material. The effect of cushion thickness using a small-scale model shaking table test has been described in Hazarika et al. (2006). The average dry density of the tire chips cushion achieved after filling and tamping was 0.675 t/m 3. About 50% to 60% of the relative densities were achieved after the preparation of the backfill. This implies that the backfill soil is partly liquefiable. Since liquefaction tends to increase the earth pressure, the presence of tire chips cushion is expected to protect the structure from the adverse effect of liquefaction within a limited region surrounding the structures during earthquake. Liquefiable backfill was thus selected on purpose. On the other hand, the foundation soils were compacted with mechanical vibrator to achieve a relative density of about 80%, implying a non-liquefiable foundation deposit. Vertical drains made out of tire chip (average grain size 7.0 mm), were installed in the backfill. Geotextile bags with the specific drain size were first prepared, which then were filled with the tire chips with a pre-determined density. They were then installed with a spacing of 150 mm in triangular pattern. The drain diameter was chosen to be 50 mm. The top of the entire drains were covered with a 50 mm thick gravel layer underlying a 50 mm thick soil cover. The purpose of such cover layer is twofold: one is to allow the free drainage of the water and other is to prevent the likely uplifting of the tire chips during shaking due to its lightweight nature. The input motion used was the N-S component of the strong motion acceleration recorded at the Port Island, Kobe, Japan during the 1995 Hyogo-ken Nanbu earthquake (M 7.2). The wave record of the motion is shown in Figure 6. The similitudes of various parameters in 1g gravitational field for the soil-structure-fluid system were calculated using the relationship given in Iai (1989) for a model to prototype ratio of 1/10. Durations of the shaking in the model testing were based on the time axes of these accelerograms, which were reduced by a factor of 5.62 according to the similitude relationship. Acceleration (Gal) Acceleration (Gal) (Gal) 600 400 200 0-200 -400-600 0.00 5.00 10.00 15.00 20.00 25.00 30.00 Time (sec) Time (s) Figure 6. Input strong motion record (The 1995 Hyogo-ken Nanbu Earthquake) 4. MODEL TEST RESULTS 4.1. Seismically induced lateral thrust Figures 7(a) and 7(b) show the time history of the increment of the seismic earth pressure acting on the quay wall at the lower middle and the upper middle part of the caisson. It can be observed that as compared to conventional backfill condition, the seismic increment is decreased to a considerable extent in tire chips reinforced backfill using

the developed technique. Considering the fact that the static earth pressure itself will also be reduced (Hazarika et al., 2008) due to low weight and compressible characteristics of the cushion materials, the total seismic thrust acting on the structure can, thus, be reduced to a greater extent. The end result, thus, is the reduction of the total earth pressure, which will contribute towards the stability of the structure during earthquakes. (a) At lower middle part (EP2 of Figure 3) (b) At upper middle part (EP3 of Figure 3) Figure 7. Lateral seismic pressure on the quay wall 4.2 Liquefaction mitigation In order to evaluate, whether the developed technique can minimize the liquefaction related damages, the time histories of the excess pore water pressure during the loading at a particular locations (B in Figure 3) for the two test cases are compared in Figures 8(a) and 8(b). Comparisons reveal that the pore water pressure build up is restricted due to dissipation by the permeable backfill condition. In the case of conventional backfill, the pore water pressure builds up and it takes considerable time (about 25 second) to dissipate. However, in the case of backfill improved by the new technique, the built up pore water pressure dissipates within a very short interval (2.5 second), preventing any chance for the backfill to liquefy. Excess pwp (kpa) (a) Conventional backfill (b) Improved by the new technique 4.3 Seismically induced horizontal displacement The time histories of the horizontal displacements (D1 and D2 in Figure 3) during the earthquake loading for the two test cases are compared in Figures 9. Comparisons reveal that the maximum displacement experienced by the quay wall with improved backfill (thick continuous line) is toward the backfill in contrast to the quay wall without any earthquake resistant reinforcement (shown in dotted line), in which case it is seaward. The compressibility of the tire chips renders flexibility to the soil-structure system, which allows the quay wall to bounce back under its inertia force, and this tendency ultimately (at the end of the loading cycles) aids in preventing the excessive seaward deformation of the wall. However, the wall with conventional backfill experiences very high seaward displacements right from the beginning due to its inertia. As a consequence, the structure cannot move back to the opposite side and ultimately suffers from a huge permanent seaward displacement. 4.4 Qualitative evaluation of the seismic performances In order to examine whether the developed technique can contribute towards the safe operation of port facilities Excess pwp (kpa) Figure 8. Liquefaction behavior

after any devastating earthquakes, differential settlements in the backfill with and without reinforcing tire chips material need to be compared. Figure 10 shows such comparison, in which the states of the backfill settlement at the end of the earthquake loading of maximum acceleration 1.5 times that of the 1995 Hyogoken Nanbu earthquake are compared. It can be observed that, the structure with conventional backfill experiences a very severe differential settlement. However, the structure with reinforced backfill does not undergo appreciable differential settlement, confirming that even in such high intensity earthquake conditions, the port facilities can remain operational, if the structure is reinforced with the earthquake resistant technique described here. (a) Bottom of the wall (D1) (b) Top of the wall (D2) Figure 9. Measured structural performance (a) Conventional backfill case (b) Cushioned backfill (a) Conventional backfill (b) Improved by the new technique Figure 10. Subsidence of the ground surface 5. CONCLUSIONS Earthquake disaster mitigation technique described and evaluated here contains three most important and beneficial elements: low cost, good seismic performance and sustainable environment. Test results have indicated that the use of the technique leads not only to reduction of the seismic load, but also the seismically induced permanent displacement of the structure. The technique also could prevent the bumpiness of the backfill after an earthquake, thus maintaining the performance of infrastructural facilities after strong earthquakes. Reduction of the load against structure implies lowering of the design seismic load, which in turn yields a slim structure with reduced material cost. Such applications of scrap tire derived material, thus, not only reduce considerably the execution and construction cost of a project, but also contribute towards a sustainable environment by recycling of the scrap tires as materials. The technique, thus, is expected to have a great potential in the cost-effective seismic design and retrofitting of structures. If adequate design method is established, the developed disaster mitigation technique could also be applied for upgrading (retrofitting) of the existing structures that run the risk of damages during devastating future earthquakes in Japan (such as strong metropolitan earthquake, Tokai earthquake, Tonankai-Nankai earthquake) as well as other earthquake prone countries in the world.

ACKNOWLEDGEMENT The financial aid for this research came from the Grant-in-Aid for scientific research (Category A; Grant No. 18206052; Principal Investigator: Hemanta Hazarika) provided by the Ministry of Education, Culture, Sport, Science, and Technology (MEXT), Japan, and the Japan Society for the Promotion of Science (JSPS). The author gratefully acknowledges this financial support. REFERENCES Hazarika, H. (2007). Structural Stability and Flexibility during Earthquakes using Tyres (SAFETY) - A Novel Application for Seismic Disaster Mitigation-, Scrap Tire Derived Geomaterials Opportunities and Challenges, Hazarika and Yasuhara Eds., pp. 115-125. Hazarika, H., Kohama, E., and Sugano, T. (2008). Shaking Table Tests on Waterfront Structures Protected with Tire chips Cushion, Journal of Geotechnical and Environmental Engineering, ASCE, USA (In Press). Hazarika, H., Sugano, T., Kikuchi, Y., Yasuhara, K., Murakami. S., Takeichi, H., Ashoke, K.K., Kishida T., Mitarai, Y. (2006). Evaluation of a recycled waste as smart geomaterial for earthquake reinforcement of structure, Proc., 41 st Japan National Conference on Geotechnical Engineering, 591-592, (in Japanese). Hazarika, H., and Yasuhara, K. (2007). Scrap Tire Derived Geomaterials Opportunities and Challenges, Taylor and Francis, UK. Hyodo, M., Yamada, S., Orense, R.P., Okamoto, M., and Hazarika, H. (2007). Undrained Cyclic Shear Properties of Tire Chip-Sand Mixtures, Scrap Tire Derived Geomaterials Opportunities and Challenges, Hazarika and Yasuhara Eds., Taylor and Francis, UK. Http://www.bousai.go.jp (2006). Cabinet Office, Government of Japan: Central Disaster Management Council, Available: http://www.bousai.go.jp/jishin/chub (in Japanese). Http://unfccc.int (2005). Kyoto Protocol to the United Nations Framework Convention on Climate Change, http://unfccc.int/resource/docs/convkp/kpeng.html. Iai, S. (1989). Similitude for Shaking Table Tests on Soil-structure-fluid Model in 1g Gravitational Field, Soils and Foundations, Japanese Geotechnical Society, Vol. 29, No. 1, pp. 105-118. Inagaki, H., Iai, S., Sugano, T., Yamazaki, H., and Inatomi, T. (1996). Performance of Caisson Type Quay Walls at Kobe Port, Special Issue, Soils and Foundations, Vol. 1, pp. 119-136. Ishihara, K. (1997). Geotechnical Aspects of the 1995 Kobe Earthquake, Terzaghi Orientation, 14th Intl. Conf. of International Society of Soil Mechanics and Geotechnical Engineering, Hamburg, Germany, Vol. 4, pp. 2047-2073. Japanese Geotechnical Society (JGS) and Japan Society for Civil Engineers (JSCE) (1996). Joint Report on the Hanshin-Awaji Earthquake Disaster (In Japanese). Kamon, M., Wako, T., Isemura, K., Sawa, K., Mimura, M., Tateyama, K., and Kobayashi, S. (1996). Geotechnical Disasters on the Waterfront, Special Issue of Soils and Foundations, Vol. 1, pp. 137-147. Kikuchi, Y., Nagatome, T. and Mitarai, Y. (2006). Failure mechanism during shear of rubber chip-mixed solidified soil, Report of the Port and Airport Institute, 45 (2) : 87-103 (in Japanese). Mitarai, Y., Kawai, H., Kishida, T., Nagatome, T., Yasuhara, K., Murakami, S., Sugano, T., Hazarika, H., Kikuchi, Y., Tatarazako, N., Takeichi, H. and Ashoke, K.K. (2006) Damping capability of impact load by used tire chips, Proc., 41 st Japan National Conference on Geotechnical Engineering, 595-596 (in Japanese). PIANC (2001). Seismic Design Guidelines for Port Structures, Balkema Publishers, Rotterdam, The Netherlands. Towhata, I., Ghalandarzadeh, A, Sundarraj, K.P., and Vargas-Monge, W. (1996). Dynamic Failures of Subsoils Observed in Waterfront Area, Special Issue of Soils and Foundations, pp. 149-160. Yasuhara, K., Hazarika, H., and Fukutake, K. (2006). Applications of Scrap Tires in Civil Engineering, Doboku Gijutsu, Vol: 61, No. 10, pp. 79-86 (in Japanese). Yasuhara, K., Unno, T., Komine, H., and Murakami, S. (2004). Gravel Drain Mitigation of Earthquake-induced Lateral Flow of Sand, 13th WCEE, No. 146(CD-ROM).