About Your NetBotz 4-20mA Sensor Pod



Similar documents
BroadBand PowerShield. User Manual

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

Triple Expansion Chassis

Wireless Indoor/ Outdoor Thermometer

How To Install A Power Supply (Uplast) With A Battery Pack

AXIS 291 1U Video Server Rack Installation Guide

Verbatim PowerBay Single USB and esata External Hard Drive Version 1.00

FCC COMPLIANCE STATEMENT


MACTek Corporation. USB HART Interface. Users Manual

USB to RS232 Adapter User s Manual

ExpressCard USB 3.0 Controller Adapter Card

3.5in Black USB 2.0 IDE SATA External Hard Drive Enclosure

Alarm Clock USER GUIDE

PCI Express USB Card. PCI Express 4 Port USB 2.0 card PEX400USB2. Instruction Manual. Actual product may vary from photo

Removable 2.5 SATA HDD Backup System

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000

15 Digital Photo Frame Instructional Manual

4 Port Hub User Manual

XTEND 900 MHZ WIRELESS MODEM For use with VEEDER-ROOT EMR³ DATALINK INSTALLATION INSTRUCTIONS Manual , Rev. B

2 Bay USB 3.0 RAID 3.5in HDD Enclosure

PCI Express USB 2.0 Adapter Card

100 - SERIES NETWORK SWITCHES QUICK START GUIDE

4 Port PCI Express Low Profile High Speed USB Card

PCI Express USB 3.0 Controller Adapter Card

iosafe Solo External Hard Drive

USB 3.0 to HDMI Adapter with 3-Port USB 3.0 Hub USB 3.0 to VGA Adapter with 3-Port USB 3.0 Hub

Sense. 3D Scanner. User Guide. See inside for use and safety information.

AXIS T81B22 DC 30W Midspan

3.5 USB 3.0 to SATA III HDD Enclosure with UASP Support

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

10/100 Power over Ethernet Kit 48V Injector and 5V/ 12V Splitter

USB/VGA Cat 5 UTP Console Extender

KVM - DVI, USB 2.0, Cat 5 Extender

Regulatory Compliance. IC Certification. FCC Certification. Declaration of Conformity

2 Port USB Keyboard Mouse Switch Cable with File Transfer for PC and Mac

24.2L M.A.N. V12 Engine Module

NFC Communication Tray Model: HHX-IT3-Z

User s Manual. Bluetooth Calculator Keypad. Page

Dual msata SSD to 2.5in SATA SSD Converter with RAID

Advantium 2 Plus Alarm

Wireless Optical Travel Mouse

Wireless Mouse USER GUIDE. for Mac. ONE YEAR LIMITED WARRANTY N2953

DMX USB PRO. User Manual.

Serial ATA Hard Drive Enclosure

Owner s Manual & Safety Instructions

User manual. Your best protection against theft and loss. (Android) Made for

16-Port and 24-Port 10/100 Switches

User Guide Microsoft Screen Sharing for Lumia Phones (HD-10)

P73474-F5U006-UNV-AM-man.qxd 9/18/00 10:10 AM Page 1

User Guide. Cordless Optical Mouse N2953

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

3.5 esata USB 2.0 to IDE SATA External Hard Drive Enclosure

Mini 4 Port USB 2.0 Hub

4 Port PCIe 2.0 SATA III 6Gbps RAID Controller

Kramer Electronics, Ltd. USER MANUAL. Rack Adapter Models: RK-1T2PT RK-2T1PT RK-3T RK-6T RK-9T RK-3TR RK-4PT RK-T2B RK-T2SB

SATA and SAS Hard Drive Backplane

FireWire 800 ExpressCard User Manual

Mini PCI Express FireWire Adapter Card

USB 3.0 to M.2 NGFF SSD Enclosure with UASP


EZ-USB 2.0 CardBus Card

INSTRUCTION MANUAL MODEL PCD-88

PCI Express FireWire & USB 2.0 card

Quick Start Guide. Control & Display Guide. Direction to Location Battery Level Indicator. Local Time. Satellite Locked Icon MARK Button.

Out-of-Band Management Card

C-Bus. Single Zone Thermostat. 5070THB Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

8 Digital Photo Frame Instructional Manual

External Hard Drive esata & USB 2.0 Combo. User Guide English

User Guide Nokia Portable Wireless Charging Plate DC-50

Professional USB to Serial Adapter Hub with COM Retention

MCR1900 Media Converter 19-Slot Chassis

LabelWriter. Print Server. User Guide

A-Series Data Loggers PRODUCT MANUAL

Instruction Guide. 2/4/6-port PCI USB 2.0 card PCI225USB PCI425USB PCI625USB2I. The Professionals Source For Hard-to-Find Computer Parts

Weather Radio Alarm Clock

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

2-Port Flush Mount ExpressCard/54 USB 3.0 Card

LF-IRX. Limited Warranty LF-IRX. Remote Control Extender OWNER S MANUAL

High Speed File Share Cable USER GUIDE

2.5/3.5 SATA HDD Docking Station

USB-RS232 Converter USB-RS422/485 Converter. User's Manual

Dual-Cool Notebook Cooler Pad. User s Manual

User and Installation Guide

Duplex ID Card & License Scanner. User Guide

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

ALL8808POE. 8 Port Gigabit PoE+ Switch. Manual

USB Port Hub with USB Power Cable. User s Manual

Ultrasonic Distance Meter. Operation Manual

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

Serial ATA Hard Drive Docking Station

2 Port PCI Express SuperSpeed USB 3.0 Card

16/32 Channel 1U Rack Mount CCTV Power Supply

1. INTRODUCTION TO SUUNTO SMART BELT 2. GETTING STARTED WITH SUUNTO SMART BELT

IMATION SECURE SCAN. ck Start Guide. Imation Secure Scan

Targus Bluetooth Keyboard for Tablets

USB-2.0 Mobile Mini Hub USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

Transcription:

Thank you for purchasing this NetBotz 4-20mA Sensor Pod. Each 4-20mA Sensor Pod enables you to connect up to four 4-20mA sensors to your NetBotz 420 or NetBotz 500 appliance. Hundreds of 4-20mA sensors are available from third-parties, including sensors designed to measure liquid flow rates, liquid levels, gases, pressure, temperature, air velocity, voltage, and more. These sensors are connected to the pod using screw terminals that are attached to the pod. The 4-20mA Sensor Pod also provides a supplemental power port (18 volts nominal, 50mA) for use with 3- and 4-wire 4-20mA sensors. The NetBotz 4-20mA Sensor Pod package includes the following items: The NetBotz 4-20mA Sensor Pod (with detachable screw terminals) 5 meter USB Cable 4 self-stick black rubber feet (can be adhered to the unit s mounting tabs for desktop-mounted pod deployments) Wall-mounting kit (includes 2 screws and 2 anchors for use in wallmounted deployments) USB cable mounting kit About Your NetBotz 4-20mA Sensor Pod (this pamphlet) Note You must provide any wiring that is necessary to connect the 4-20mA sensors to the screw terminals. Before You Begin Before continuing, be sure you have the latest available version of Using Your Appliance. You can obtain the latest available version of this publication (as a PDF file) from the NetBotz Technical Support site at: http://www.netbotz.com/support Once you have opened the NetBotz Technical Support web page, select your appliance model from the Monitoring and Management Appliances drop box, click Go, and then click on Using Your Appliance in the list of downloadable Product Pubs. Using Your Appliance contains information and instructions you will need to complete installation and configuration of the NetBotz 4-20mA Sensor Pod. 1

Installing the 4-20mA Sensor Pod Important! Before connecting your NetBotz 4-20mA Sensor Pod to your NetBotz appliance, first use the Upgrade task in the Advanced View to ensure that your appliance is running BotzWare 2.2.2 or later. Earlier versions of BotzWare do not support 4-20mA sensors and will not recognize or be able to use the NetBotz 4-20mA Sensor Pod. To install the NetBotz 4-20mA Sensor Pod, connect the pod to your NetBotz appliance, or to a powered USB hub that is connected to the NetBotz appliance. Note Due to power requirements, your NetBotz 4-20mA Sensor Pod must be connected either directly to one of the NetBotz appliances USB ports or to a powered USB hub. If a USB cable extension is required, use either a NetBotz CAT 5 or Fiber 500m Cable Extender. Use of other USB cable extenders may result in inadequate power supply for the sensors and is not recommended by NetBotz. The 4-20mA Sensor Pod also features 4 mounting tabs. These mounting tabs are designed to allow the 4-20mA Sensor Pod to be mounted along one edge of a standard 19" rack or to be mounted on a wall/backboard. Alternatively, you can adhere the 4 self-stick black rubber feet to the mounting tabs to help prevent the pod from sliding or shifting when deployed on a table or desktop. Connecting 4-20mA Sensors to your 4-20mA Sensor Pod The 4-20mA Sensor Pod features 5 removable screw terminal blocks: 4 of the terminal blocks provide 4 matched positive/negative sensor connections and the 5th terminal block provides a DC supply negative (common) terminal and a positive (18V) terminal to supply up to 50mA of supplemental power to 3- and 4-wire 4-20mA sensors. 2 About Your NetBotz 4-20mA Sensor Pod

To connect a sensor to the 4-20mA Sensor Pod, disconnect the required terminal block (or blocks) from the Sensor Pod. Then, using a small slotted screwdriver, refer to the sensor manufacturer s instructions and the wiring examples in this booklet (see Wiring Examples on page 5) to connect the sensor wires as necessary. Note If you are installing multiple 3- or 4-wire sensors, be sure that the combined supplemental power demand of the sensors does not exceed that 50mA maximum that can be supplied by the DC Supply port on the 4-20mA Sensor Pod. When you have finished connecting devices to the terminal blocks, reconnect the terminal blocks to the 4-20mA Sensor Pod. Then use the Basic View Configuration pane or the Advanced View Sensor Pods task to specify the type of 4-20mA sensor that is connected to each of the pod ports. If you do not currently have a preconfigured sensor type that matches the specific 4-20mA sensor or sensors you connected to your pod, use the Add Custom Sensor functionality to define a custom 4-20mA sensor type. For complete instructions, see Using Your Appliance. Wire Length Guide The maximum length of wire that can be used to connect a 4-120mA sensor to the 4-20mA Sensor Pod is dependent on both the voltage required to power the sensor and the gauge of wire that is used. For general guidelines to maximum wire length (in feet) refer to the table below. Note that these guidelines assume that the 4-20mA Sensor Pod is being used as specified, which ensures that the pod is receiving a full 5V of power from the USB port and that the load on the DC Power supply does not exceed 50mA. Wire Gauge 20 22 24 26 28 Volts Required 6 13,300 8,300 5,100 3,200 1,900 8 10,000 6,200 3,800 2,400 1,400 10 6,600 4,100 2,500 1,600 900 12 3,300 2,000 1,200 800 400 About Your NetBotz 4-20mA Sensor Pod 3

Wiring Examples 4 About Your NetBotz 4-20mA Sensor Pod

Specifications Accuracy: +/- 0.5 % Full Scale Sensor I/O Current Range: 0 to 23mA Open is detected at 3mA Overcurrent is detected at 23mA DC Supply Port: Non-Isolated, Unregulated 18V DC, 50mA MAX Operational Environment: 35 to 120 deg F, 5 % RH to 95% RH noncondensing Sense voltage drop: 1V DC @ 20mA Designed for indoor use only. Wiring Recommendations: Use AWG 16 to AWG 28 wire for best results. Twisted-pair recommended for loop lengths greater than 100. Federal Communications Commission (FCC) Declaration of Conformity Statement Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense. Cleaning Your 4-20mA Sensor Pod Use only a dry cloth to clean the 4-20mA Sensor Pod housing. Gently wipe the surface of the 4-20mA Sensor Pod with a dry cloth. Warranty NetBotz Inc. warrants the 4-20mA Sensor Pod to be free from defects in materials and workmanship for a period of one year from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. This warranty does not apply to equipment that has been damaged by accident, negligence, or misapplication or has been altered or modified in any way. This warranty applies only to the original purchaser. About Your NetBotz 4-20mA Sensor Pod 5

Warranty Limitations Except as provided herein, NetBotz Inc. makes no warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. Some jurisdictions do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser. Except as provided above, in no event will NetBotz Inc. be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of this product, even if advised of the possibility of such damage. Specifically, NetBotz Inc. is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise. This warranty gives you specific legal rights and you may also have other rights, which vary from state to state. Trademarks BotzWare, NetBotz, RackBotz, WallBotz, and the NetBotz symbol are registered trademarks of NetBotz, Inc. PN: 02176D01 6 About Your NetBotz 4-20mA Sensor Pod