Electronic Pressure Switch EDS 3000



Similar documents
Electronic Pressure Switch EDS 300

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Pressure transmitter For general industrial applications Model A-10

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Relative and absolute pressure switch type 529

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Series 6000 Torque measured metal bellow coupling

Turbine Flow Sensor Series VTR

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Conductive Level Switch FK 2 Technical Data:

Digital display DA 48

Operating instructions Optical distance sensor O1D100 O1D / / 2012

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Series 7500 Torque Sensor

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Features. Picture. Specifications

Safety at a high level!

Givare NC-SRS 280 och 880

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Electronic Pressure Switches

ATL Fuel Level Sender Probes

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Inductive sensor NI10-M18-Y1X-H1141

Electronic Pressure Monitoring New Products

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Series DFMT Digital Paddlewheel Flowmeter

Liquid Level Limit Switch liquiphant T FTL 20

Relative pressure transmitter type 520

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Operating Instructions for Plastic Flow Meter. Model: KSK

Druck DPI 104. GE Industrial Sensing. Digital pressure indicator User manual - K394

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

Models SFP33 & SFP32 Pressure Transmitters

UM-X Field display for continous level sensors

Digital Pressure Measuring Instrument MDR480

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

is then retained absolutely without interruption.

Series 510 Submersible Level Transmitters

9000 Series Accelerometers Specifications

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Description. Dimensions. Features. precision works better

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Cable Plug acc. to DIN EN , Form A

LED...A Q Series Sealed High-Intensity

D. PARAMETER SPECIFICATION Measured Variable: Displacement

4 Posiflow Proportional Solenoid Valves

Heating, air-conditioning, cooling

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

PTU Series Transducer Digital Display Indicator User s Manual

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Electrical connection

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

How To Use A Flowmeter

Differential-Hall-Effect based Sensors Series A5S

Adjustment functions for both span and shift have been incorporated

Operating instructions Capacitive sensors

Combi switchbox with integrated 3/2 way pilot valve

GREISINGER electronic GmbH

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Instruction Manual Differential Pressure Transmitter

DPI 260 SERIES: Digital Pressure Indicators

Technical Information RIA14

Combi B Alarm box. Mounting instructions

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Actuators and Sensors. Products

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Digital inductive conductivity transmitter

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Product Catalogue. AP Automatyka ISO ISO OHSAS ISO 9001.

psens Pressure Measurement

Smart Sensing Solutions Since 1954

Fast, reliable, ultra-precise. My-Com precision switches.

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

Subminiature Load Cell Model 8417

HERZ-Thermal Actuators

3-Component Measuring System

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Transcription:

For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions

The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or a freely scalable range. Display of the actual pressure, maximum measured pressure or a switching point. Operation of the switching outputs according to the pressure and the adjusted switch-point parameters or by using the window feature. Depending on the l, the choice of selecting either a 4...20mA or 0...10VDC analog output signal. Menus for adjustment (adapting the EDS 3000 to a particular application). Programming enables (lockouts). 4 different output versions are available: EDS 3000 with 1 switching output EDS 3000 with 1 switching output and analog signal output EDS 3000 with 2 switching outputs EDS 3000 with 2 switching outputs and analog signal output 2. Mounting The EDS 3000 can be mounted onto a hydraulic block via the G¼ form A (DIN 3852) external threaded pressure connection. After mounting, the EDS can be rotated for optimal adjustment around its longitudinal axis, additionally is possible to rotate the display for better viewing and access to the control keys. The electrical connections must be carried out by a qualified electrician according to applicable codes, laws or regulations that pertain to the location (VDE 0100 in Germany). The EDS housing must be grounded properly. When mounted to a hydraulic block, it is sufficient if the block is grounded over the hydraulic system. When mounting by means of hose, the housing must be grounded separately. Also try to follow these installation recommendations to reduce the effect of electromagnetic interference: Make electrical cable connections as short as possible. Use shielded cable. The shielded cable must be fitted by qualified personal using interference suppressing techniques. Direct proximity to other connection lines of units generating interference or the unit itself must be avoided. 2

3. EDS 3000 Display and User Interface PSI MPa 4-digit display Keys for adjusting menu and switch points 4. Digital Display After switching on the supply voltage, the EDS displays " EdS " briefly followed by the measured pressure. In the adjustment menu the display can be altered. For example, the maximum measured pressure value can be permanently displayed. This is the highest measured value since the unit was last switched on or reset. Pressing the or will reset the highest measured value. Also a switching point value can be permanently displayed or the display can be set to dark. If set to dark, the measured pressure can be displayed briefly by pressing the or key. Depending on the setting, TOP, S.P. 1, S.P. 2 or off will appear breifly in the display when the unit is switched on informing the user what the display will show. Notes 2 s If the applied pressure exceeds the measuring range of the EDS, it will no longer display the pressure and the display will begin to flash. If applied pressure is below 1% of the measuring range, then 0 is displayed. 3

5. Output Functions 5.1 Switching Outputs The EDS 3000 can have 1 or 2 switching outputs. The following settings can be made under the switch-point and adjustments menu: 5.1.1 Switch point setting (SP) One switch point and one hysteresis can be set for each switching output. The respective output switches when the user set switch point pressure value is reached and switches back when the pressure falls below the switchback point. The switchback point is calculated by subtracting the hysteresis value from the switching point value. (switch back point = switching point hysteresis) Abbreviations: "SP.1" or "SP.2" = switching point 1 or 2 "HyS.1 or "HyS.2" = hysteresis 1 or 2 5.1.2 Window Function Settings (WIN) The window function enables a range of pressure to be monitored. For each switching output, an upper and a lower switching value can be set to determine the range. The respective output switches when the pressure enters this range. When the pressure leaves the range and the switch back value has been met, the output switches back. The lower switch back value is just below the lower switching value (lower switching value minus three times the increment, see point 5.4). The upper switch back value is just above the upper switching value (upper switching value plus three times the increment, see point 5.4). The area between switching and switch back value forms a safety zone, which prevents unwanted switching operations from occurring (e.g. triggered by pulsation from a pump). Example of switching output 1 (normally open function): P hi.1 plus 3xincrement hi.1 Off Safety zone On Switch-back valuet Switching value Lo.1 Lo.1 minus 3xincrement On Safety zone Off Switching value Switch-back value t ON Off Abbreviations: "HI 1" = High level 1 "Lo 1 = Low level 1 Note: The window function only operates correctly (switching on and off) when all switching values (including the safety zone) are greater than 0 and are lower than the pressure measuring range. 4

5.2 Analog Output On specified ls, the EDS 3000 has a choice of 4...20mA or 0...10VDC sourcing signal output which is selectable in the adjustment menu. 5.3 Setting the Switching Points and Hysteresis Press key. In the display "S.p.1" appears or "Hi.1 Keep pressing the key until the desired parameter is displayed (depending on the adjustment menu setting: S.p.1","HyS.1", "S.p.2", "HyS.2" or with adjusted window function "Hi.1", "Lo.1", "Hi.2" or "Lo.2"). After 2 seconds the adjustment value flashes. Use the or key to alter the setting. After 3 seconds without key activity, the display resets and the adjustments are stored. Change until the required parameter is reached Display 2 s 3 s Actual switch point 1 Switching point =Decrease =Increase Notes: If "LOC" appears in the display when trying to alter settings, programming is disabled. Corrective action: set programming enable to on. See section 7 for details. If the or key is held down, the value will automatically advance. If a setting has been altered, PRG will appear briefly in the display when the 3 second timer ends. 5

5.4 Ranges of Adjustment for the Switching Outputs Measuring range in Switching point or upper switching value in Hysteresis point or lower switching value in Increment * in 1 0.008.. 1 0.006.. 0.99 0.002 2.5 0.02.. 2.5 0.015.. 2.47 0.005 4 0.03.. 4 0.02.. 3.96 0.010 10 0.08.. 10 0.06.. 9.90 0.020 16 0.15.. 16 0.10.. 15.85 0.050 25 0.2.. 25 0.15.. 24.75 0.050 40 0.3.. 40 0.2.. 39.60 0.100 60 0.5.. 60 0.3.. 59.40 0.100 100 0.8.. 100 0.6.. 99.00 0.200 250 2.0.. 250 1.5.. 247.50 0.500 400 3.0.. 400 2.0.. 396.00 1.000 600 5.0.. 600 3.0.. 594.00 1.000 * All areas indicated in the table are adjustable by the increments shown. 6

6. Menu Adjustments In order to adapt the unit to a particular application, the EDS 3000 can be altered via several menu settings. 6.1 Altering the Menu Settings Important Note: When the menu is accessed, no switching operations are performed. Press key and hold down. Switch on supply voltage (hold key down for 3s) 3 s Display (Release key) Press key until the required menu point appears in the display. (For summary, see 6.2) Use or to alter the setting, then select next menu point. To exit the menu Select the menu point END and set to YES. The EDS will return to normal display and switching after 2 seconds. Note: If no menu activity occurs after 25 seconds, the menu will automatically close and return the EDS to normal operation. Any changes that were made will not be saved. 7

6.2 Outline of the Adjustment Menu Points Setting Point Display Setting Choices Switch for Switch output 1 (Sm 1) Switch output 1 operates in switch point\hysteresis SP/ Win Factory Setting SP Switch output 1 operates in window. Switching direction Switching output 1 (S 1) Normally open function. ON/ OFF ON Normally closed function Switch-on delay switching output 1 (Ton 1) Length of time in seconds that must expire once the switch point has been reached before the switch output will function. 0.00..99.99s 0 Switch-off delay switching output 1 (Toff 1) Length of time in seconds that must expire once the switch back point has been reached before the switch output will function. 0.00..99.99s 0 The adjustment procedure for switch point 2 is the same as described above. Primary display (primary) Display function shown: Currently measured pressure Maximum pressure measured (peak) ACT/ Top/ S.P.1/ S.P.2/ OFF ACT or Switch point 1 or 2 setting Dark display (see section 4 for detail) Reset time (RTIM) Only available when the display is set to Top in the menu. Sets how long the pressure peak value in the display achieved last will be displayed. 0..300s 0 8

Adjustment Display Range of adjustment Display SLOW/ Display reacts slowly to pressure MEDI/ changes. FAST Default MEDI Display reacts normal to pressure changes. Display reacts quickly to pressure changes. Pressure Range Scale Pressure in Bar. Pressure in PSI. Pressure in MPa The normal range can be scaled freely. If this adjustment is selected, the decimal place as well as upper and lower range limits must be adjusted. Example: If the range has been changed to 0...215.5, the display value 215.5 corresponds to the maximum pressure capable of being measured by the EDS. Application: Display other scales like KN, Kg, etc. BAR/ PSI/ MPa/ FREE BAR Decimal Place Only available when range is set to FREE. 0..0.000 0.0 Placement of decimal point is selectable below a display value of 3000. Low Range Only available when range is set to FREE. -999..9899 0.0 High Range Only available when range is set to FREE. -899..9899 Meas. range final value 9

Analog Output The analog output supplies a 4...20mA DC sourcing output signal. The analog output supplies a 0...10VDC sourcing output signal. Zero Point Calibration (Calibrate) The pressure at that point in time is stored as a new zero point. This is possible in the area +/- 3% of the pressure range of the EDS. MAMP/ VOLT YES/ NO VOLT NO This will be displayed if your new calibration is within 3% of 0 pressure. Example: This will appear if the pressure applied to the EDS is more than 3% of the measuring range and a zero point calibration is attempted. If you have a 600 EDS, up to 18 can be applied to the switch and a zero point calibration could be performed to have the display show 0. Version Displays the current software version. End Use to exit the adjustment menu. YES/ NO NO Continue adjustments. If menu adjustments were changed then upon exiting ProG will be displayed. This notifies the user changes have been made and stored. 10

7. Programming Enables The EDS has 2 types of programming enables which must be set to ON to change any of the settings in the switch point menu or the adjustment menu. These enables can be set to prohibit unintentional or unauthorized changes. 7.1 Altering the Switch-point Programming Enable Druckanzeige Pressure Press both arrows simutaneously and hold for 3s. 3 s Display (release arrow keys) 2 s With or 3 s alter setting FrEE = programming possible Loc = Programming locked 7.2 Altering the Adjustment Menu Enable Remove voltage supply from EDS. Druckanzeige Pressure Press both arrows simutaneously and hold. Switch on supply voltage. 3 s Display (release both keys) 2 s Use or to alter setting FrEE = Programming possible Loc = Programming disabled 3 s Note: If an adjustment was performed in the menu, the display after switching back on will show ProG" for a brief period. The new setting is then stored in the device. 11

8. Error Codes If the EDS detects an error, then a corresponding error code will be displayed. Possible error codes are as follow: E.01 The switching point and hysteresis have been set in such a way that the resulting switchback point is no longer within the permissible setting range. Corrective action: Correct the settings. E.10 A data error has been detected in the saved settings. Possible causes are strong electromagnetic interference or an internal circuit fault. Corrective action: Check the settings (programming enables, switch point settings, adjustment menu settings) and correct these if possible. If the errors occur frequently, please contact Hydac. E.12 An error has been detected in the stored calibration data. Possible causes are strong electromagnetic interference or an internal circuit fault. Corrective action: Switch the unit off and then on. If the error message is still displayed, the unit must be returned to the manufacture for re-calibration or repair. E.20 A short circuit has been detected on a switch output. Corrective action: Eliminate the short circuit. 12

9. Technical Data Inputs: Measuring Range Ceramic - Absolute: Overload pressure: Burst pressure: Measuring Range Ceramic - Gauge: Overload pressure: Burst pressure: Measuring Range Thin Film DMS Gauge: Overload pressure: Burst pressure: Accuracy data: Accuracy (display, analogue output): Repeatability Temperature Drift: Analog signal output: Switching outputs: Type: Switching current: Cycles: Reaction time: DESINA Diagnostic signal (Pin 2): Function Level Switch on time (power on) Reaction Environment conditions: Normal temperature: Ambient temperature: Storage temperature: Nominal temperature: 15, 50 psi 2x 3x 0 15, 30, 50, 150, 250, 500 & -14 75 psi 2x 3x 0 1000, 3000, 6000, 9000 psi 2x 3x ±0.5 % FS typ. ±0.25 % FS max. ±0.017%FS/ F max. zero point ±0.017%FS/ F max. span Selectable 0...10VDC or 4... 20 ma DC PNP-Transistor output Max. 1.2 A > 100 Million < 10 ms I/O: HIGH-Level, I/O NOT: Low-level HIGH = +Supply VDC LOW = <+0.3 VDC -25.. + 80 C (-13...+176 F) -25.. + 80 C (-13...+176 F) -40.. + 80 C (-40...+176 F) -25.. + 85 C (-13...+185 F) -Mark: EN 50081-1, EN 50081-2, EN 50082-1, EN 61000-6-2 Vibration Resistance: 10 g / 0..500 Hz Shock Resistance: 50 g / 1ms Other Data: Supply voltage: 18.. 32 VDC Electrical connection: M12x1 (4-pin or 5-pin) Power input: 100 ma (without switching output load) Enclosure rating: IP 67 (w/ molded M12 cable connector) Mechanical Connection: ¼ NPT male or SAE-6 male (standard) Parts in contact with medium: Stainless steel, Viton seal; Ceramic Housing Material: Display: 4-digit, 7 segment LED, red Weight: approx. 300 g Note: FS (Full Scale) = related to the full measuring range 13

10. Circuit Diagrams Model with 1 switch output Plug 4-pol. M12x1 Model with 1 switch output and signal output Plug 4-pol. M12x1 + 20..32 V - 1 EDS 3X46-1 3 4 Imax. 1.2 A SP 1 + 20..32 V - Imax. 1.2 A 1 4 SP 1 EDS 3X46-3 I = 4..20 ma 3 2 Analog RL Model with 2 switch outputs Model with 2 switch outputs and signal output Plug 4-pol. M12x1 Plug 5-pol. M12x1 + 20..32 V - 1 4 EDS 3X46-2 3 2 Imax. 1.2 A SP 1 Imax. 1.2 A SP 2 Imax. 1.2 A + 4 1 SP 1 EDS 3X48-5 20..32 V Imax. 1.2 A 5 SP 2-3 I = 4..20 ma 2 Analog RL 14

11. Model Code EDS 3 X 4 X - X - XXXX - XXX Series # Sensor Type 2 = Ceramic absolute 3 = Ceramic Relative 4 = Thin-film relative Mechanical Connection 6 = 1/4-18 NPT male thread (brass types 1 and 3) 7 = SAE-6 male thread (9/16-18 UNF2A stainless steel type 4) Electrical Connection 6 = Plug M12x1, 4-pol. only with the output version 1, 2 and 3 (without quick coupling socket) 8 = Plug M12x1, 5-pol. only with the output version 5 (without quick coupling socket) Output 1 = 1 Switching Output (only with electrical connection 6) 2 = 2 Switch Output (only with electrical connection 6) 3 = 1 Switch with analog output (only with electrical connection 6) 5 = 2 Switch with analog ouput (only with electrical connection 8) Pressure Ranges in Type 2 (Ceramic - Absolute) Type 3 (Ceramic relative) Type 4 (Thin-film, relative) Modification number 000 = Standard 1; 2.5 1; 2.5; 4; 10; 16; 25; 40 40; 60; 100; 250; 400; 600 150; 1000; 3000; 6000; 9000 15

12. Accessories 12.1 For Electrical Connection ZBE 06 (4-pol.) and ZBE 08 (5-pol.) ZBE 06-02 Screw-type coupling socket with 2m length, 4-pol. M12x1, right-angle ZBE 06-05 Screw-type coupling socket with 5m length, 4-pol. M12x1, right-angle ZBE 06-02S Quick coupling socket with 2m length protected, 4-pol. M12x1, right-angle ZBE 06-05S Quick coupling socket with 5m length protected, 4-pol. M12x1, right-angle ZBE 08-02 ZBE 08-05 Screw-type coupling socket with 2m length, 5-pol. M12x1, right-angle Screw-type coupling socket with 5m length, 5-pol. M12x1, right-angle ZBE 08-02S Quick coupling socket with 2m length protected, 5-pol. M12x1, right-angle ZBE 08-05S Quick coupling socket with 5m length protected, 5-pol. M12x1, right-angle Color: Color: Pin 1: Pin 2: Pin 3: Pin 4: brown white blue black Pin 1: Pin 2: Pin 3: Pin 4: Pin 5: brown white blue black gray ZBE 06 (4-pol.) ZBE 08 (5-pol.) Quick coupling socket M12x1, right-angle 16

13. Dimensions 17